| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | ₹24.1 L Quoted ₹24.4 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹25.9 LRejected-Finance | ₹25.9 L | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹26.3 LRejected-Finance | ₹26.3 L | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹27.1 LRejected-Finance S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | ₹27.1 L | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹28.4 LRejected-Finance | ₹28.4 L | L5 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Srinivasa Consructions L1 | M/s K L M INFRATECH L7 | sandhya enterprises L2 | K LAKSHMAN SINGH AND CO L6 | M/S PAVANI ENTERPRISES L5 | M.R.ENTERPRISES L3 | Charan sales and Service L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying, installation, Testing & Commissioning of Street light 120 W IP 66 LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than
the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) | 40 | Each | 5,300 ₹2.1 L | 8,500 ₹3.4 L | 4,800 ₹1.9 L | 5,500 ₹2.2 L | 5,000 ₹2 L | 4,800 ₹1.9 L | 5,500 ₹2.2 L |
| 2.00 | Supplying, installation, Testing & Commissioning of Flood Light,LED 120 W IP 65 powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP
66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report
from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). | 25 | EACH | 5,800 ₹1.4 L | 9,000 ₹2.3 L | 4,800 ₹1.2 L | 5,500 ₹1.4 L | 5,000 ₹1.3 L | 5,800 ₹1.4 L | 5,500 ₹1.4 L |
| 3.00 | Supplying, installation, Testing & Commissioning of Street light 35 W IP 66 LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than
the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) | 40 | Each | 1,500 ₹60,000 | 2,500 ₹1 L | 1,900 ₹76,000 | 2,500 ₹1 L | 3,500 ₹1.4 L | 1,550 ₹62,000 | 2,600 ₹1.0 L |
| 4.00 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. as light source sample as approved by Engineer in charge | 20 | Each | 2,000 ₹40,000 | 9,000 ₹1.8 L | 4,000 ₹80,000 | 6,000 ₹1.2 L | 8,500 ₹1.7 L | 3,800 ₹76,000 | 3,000 ₹60,000 |
| 5.00 | Supplying, installation, Testing & Commissioning of Flood Light,LED 200 W IP 66 powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP
66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report
from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). | 25 | Each | 7,800 ₹1.9 L | 19,000 ₹4.8 L | 6,800 ₹1.7 L | 12,000 ₹3 L | 8,300 ₹2.1 L | 9,900 ₹2.5 L | 7,000 ₹1.8 L |
| 6.00 | Supplying, installation, Testing & Commissioning of Flood Light,LED 100 W IP 66 powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP
66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report
from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). | 30 | Each | 4,200 ₹1.3 L | 9,000 ₹2.7 L | 6,800 ₹2.0 L | 10,000 ₹3 L | 5,000 ₹1.5 L | 4,500 ₹1.4 L | 5,500 ₹1.6 L |
| 7.00 | M&L for disconnection of electric supply and water supply pipe line of solar water heater/ collector plates of any size from site for repair/ overhauling/ replacement of unserviceable parts incl nut and bolts with washers and refixing the same in serviceable condition after assembling , testing and re connecting the electrical and water supply line all as specified and directed by Engr-in-charge. | 1 | Each | 3,000 ₹3,000 | 800 ₹800 | 3,600 ₹3,600 | 400 ₹400 | 2,500 ₹2,500 | 500 ₹500 | 2,000 ₹2,000 |
| 8.00 | S&F 2 KW solar water heater element incl taking down old solar water heater element complete all as specified. | 1 | Each | 1,000 ₹1,000 | 700 ₹700 | 1,350 ₹1,350 | 1,500 ₹1,500 | 2,500 ₹2,500 | 560 ₹560 | 2,000 ₹2,000 |
| 9.00 | M&L for replacement of old unserviceable 200 LPD hot water tank fully insulated all as specified and directed by Engr-in-Charge. Make-TATA or equivalent as per sample. | 1 | Each | 10,000 ₹10,000 | 15,000 ₹15,000 | 22,500 ₹22,500 | 2,500 ₹2,500 | 35,000 ₹35,000 | 12,500 ₹12,500 | 15,000 ₹15,000 |
| 10.00 | M&L for descaling of pipe line with chemical powder and liquid (4 Kg each) of solar collector plates, solar water heating tank all as directed. | 1 | Each | 1,000 ₹1,000 | 800 ₹800 | 1,800 ₹1,800 | 1,000 ₹1,000 | 3,000 ₹3,000 | 500 ₹500 | 2,000 ₹2,000 |
Updated dates
Tender Value
₹47.8 L
EMD Value
₹95,540
Closing Date
6 Feb 2026, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad-500058
REPAIR/ MAINT OF BLDG SECURITY LIGHT, SOLAR WATER HEATER, SOLAR FENCING AT DMDE AREA AND CE RND AREA UNDER GE (I) RND KBAGH, HYDERABAD
2026_MES_747809_1
8164
Open Tender
Civil Works
180 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹95,540
Yes
25 May 2026
9 Jan 2026
9 Feb 2026
9 Jan 2026
6 Feb 2026
23 Jan 2026
Supplying, installation, Testing & Commissioning of Street light 120 W IP 66 LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
Supplying, installation, Testing & Commissioning of Flood Light,LED 120 W IP 65 powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supplying, installation, Testing & Commissioning of Street light 35 W IP 66 LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. as light source sample as approved by Engineer in charge
Supplying, installation, Testing & Commissioning of Flood Light,LED 200 W IP 66 powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supplying, installation, Testing & Commissioning of Flood Light,LED 100 W IP 66 powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
M&L for disconnection of electric supply and water supply pipe line of solar water heater/ collector plates of any size from site for repair/ overhauling/ replacement of unserviceable parts incl nut and bolts with washers and refixing the same in serviceable condition after assembling , testing and re connecting the electrical and water supply line all as specified and directed by Engr-in-charge.
S&F 2 KW solar water heater element incl taking down old solar water heater element complete all as specified.
M&L for replacement of old unserviceable 200 LPD hot water tank fully insulated all as specified and directed by Engr-in-Charge. Make-TATA or equivalent as per sample.
M&L for descaling of pipe line with chemical powder and liquid (4 Kg each) of solar collector plates, solar water heating tank all as directed.
M&L for welding work of rusted portion of complete set of collector panel including metal/ GI pipe where necessary.
Supplying, installation, Testing & Commissioning of Street light 60 W IP 66 LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
S&F Pole junction box, made up of sheet moulding compound (SMC) type with hinged type door and locking arrangement, white colour of size 280x170x130mm outside and 240x130x110mm internal dimensions comprising 01 No-16 Amps capacity kitkat fuse, aluminium busbar-04 Nos, earthing terminals, bolts & nuts and connecting up cables with aluminium terminal lugs including suitable size clamps,bolts, nuts and washers fixed on pole complete and taking down unserviceable junction box complete all as directed Make - Sintex or equivalent ISI marked
S&F Laying LT UG cable heavy duty armoured with aluminum conductor multistranded PVC insulated and sheathed with suitable lugs including taking out old unserviceable cable complete all as directed for following sizes: -
2 core 10 Sqmm
4core 16 Sqmm
3.5 core 25 Sqmm.
Supplying, installation, Testing & Commissioning of Street light 90 W IP 66 LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
M&L for Refilling of Dry chemical type fire extinguisher capacity 5 Kg complete all as directed.
M&L for Refilling of Mechanical foam type fire extinguisher capacity 9 Liters complete all as directed.
M&L for Point wiring complete with and including 1.5 sq. mm (nominal area) single core multi stranded FRLS copper conductor PVC insulated unsheathed cable 1100 volts grade ISI marked drawn through in and including concealed non metallic rigid PVC conduit with accessories such as bend ,tees, junction boxes etc. suitable modular boxes for mounting fittings like modular switches, modular sockets and fan regulators etc with modular sheet covers including one run of 1.5 Sqmm PVC insulated and unsheathed multi strand FRLS copper conductor as green color earth wire and connected to common earth dully inclulding taking down existing point wiring complete all as specified and directed for the following:-
one light/fan/bell point controlled by one switch
one 3 pin socket outlet 5A on independent board
one 3 pin socket outlet 5A only on same board.
All as per item No.8 above but with 2.5 sq mm size pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3/6 pin socket outlet 15 amp on one independent board.
S&F Modular Switch one way 6 Amps, 1 module all as specified and directed.
S&F Modular Socket 2 module for 2 / 3 pin 6 Amp all as specified and directed.
S&F Modular Switch one way 16 Amps, 1 module all as specified and directed.
S&F in repairs Modular bell push, flush type, 5 amp
S&F Socket 2 module 2 in 1, 3 pin, 6 and 16 Amp, complete all as specified and directed .
S&F ceiling rose PVC / polycarbonate isolated body 3 terminals with base plate ISI marked including taking down old unserviceable ceiling rose complete all as specified and directed..
S&F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <=20W, luminaries lumen >2000 lm, system efficiency of > 100 lumens/W, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, color temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) including taking down old unserviceable light fitting of any description complete all as specified and directed. Make:- Wipro/Philips/Bajaj/polycab/Havells
S&F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <=10W, luminaries lumen >2000 lm, system efficiency of > 100 lumens/W, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, color temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) including taking down old unserviceable light fitting of any description complete all as specified and directed. Make:- Wipro/Philips/Bajaj/polycab/Havells
Supply and fix in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into existing T8 conventional fluorescent tube light fitting after changing the necessary electric connections as required at site complete all as specified and directed. Make : Crompton, Cat No : LT8-20-865-2 , Havells, Cat No : PHOTONULTRA1213T8SSTL20WLED865SPC, PHILIPS Cat no MAS LED tube 1200 mm 18 w 865 T8 I - 2100 Lumen or equivalent in Wipro/Philips/Bajaj/polycab/Havells
S&F 2 ft x 2ft recess mounted full panel LED luminaries with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser , in built electronic driver duly wired up to terminal block, power consumption< 36W, luminaries lumen > 3500lm and system efficiency >120lm/W, CRI>80, color temp -5700K, Ingress protection IP 20, , driver efficiency >85%, 50,000 burning hours (min) , range 150-270V AC and safety extra low voltage safe level <60V DC including taking down old unserviceable light fitting of any description complete all as specified and directed. Make:- Wipro/Philips/Bajaj/polycab/Havells
S&F 2 ft x 2ft recess mounted full panel LED luminaries ( Warm White) with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser , in built electronic driver duly wired up to terminal block, power consumption< 36W, luminaries lumen > 3500lm and system efficiency >120lm/W, CRI>80, color temp -3000K, Ingress protection IP 20, , driver efficiency >85%, 50,000 burning hours (min) , range 150-270V AC and safety extra low voltage safe level <60V DC including taking down old unserviceable light fitting of any description complete and fixing of false ceiling paneling all as specified and directed. Make:- Wipro/Philips/Bajaj/polycab/Havells
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 4 sqmm (nominal area) 1100 volts grade multistranded FRLS copper conductor with one run of 4 sqmm PVC insulated unsheathed multistranded single core copper conductor 1100 V grade and connecting to common earth drawn through and including PVC concealed conduit medium grade ISI mark not less than 25mm outer dia complete and accessories of suitbale size as required. Note : Three run of 4 sqmm cable and one run of conduit shall be measured and paid as one length.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 6 sqmm (nominal area) 1100 volts grade multistranded FRLS copper conductor with one run of 6 sqmm PVC insulated unsheathed multistranded single core copper conductor 1100 V grade and connecting to common earth drawn through and including PVC concealed conduit medium grade ISI mark not less than 25mm outer dia complete and accessories of suitbale size as required. Note : Three run of 6 sqmm cable and one run of conduit shall be measured and paid as one length.
Supply and fix exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 300 mm sweep 1400 RPM ISI marked, and making connection with twisted copper flexibelwire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
Supply and fix exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 225/230 mm sweep 1400 RPM ISI marked and making connection with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
Supply and fixing wall fan of 400 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 Cum/min with all accessories complete all as directed by Engineer - in - charge. Make:- Bajaj/Havells/Crompton/Usha
Supply and fix PVC exhaust fan 200 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engr-in-Charge. Make:- Bajaj/Havells/Crompton/Usha
Supply and fixing of stationery storage type electric BEE 5 star rated Hot Water Geyser of capacity 25 Ltr to operate on 230 volt AC, vertical type, white in colour, working pressure min 0.8 Mpa with glass lined coated tank, magnesium anode, adjustable thermostat, enamel coated incology heating element 2 KW, ABS plastic body including 4 nos full threaded fastner of size 100 x 10 mm with 2 Nos washer, complete all as specified and directed. Make: Bajaj/Racold/Usha/venus/Orient electric
PVC hose for hot /coldwater 450mm long with brass end nuts (ISI marked) suitable for 15mm dia GI tubing complete.
Material and labor for earthing complete with galvanized mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanized iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
S&F full glow, (4 ft) LED luminaire, glare free and provision of cable from ceiling rose to light fitting including taking down unserviceable light fitting complete all as directed.
S&F Surface mounting Metal / PVC flush box 1/2 module 3 module including 3 modules inner plate & outer cover and taking down unserviceable Metal box complete all as directed by Engineer-in-Charge.
S&F Surface mounting Metal / PVC flush box 6 module including 6 modules inner plate & outer cover and taking down unserviceable Metal box complete all as directed by Engineer-in-Charge.
S&F surface mounting Metal / PVC flush box 8 module including 8 module inner plate & outer cover and taking down unserviceable Metal box complete all as directed by Engineer-in-Charge.
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 12 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed
M&L for double door distribution board made of sheet metal TPN 4 way with 200 Amps rated bus bar with metal door including taking down unserviceable distribution board complete all as directed by Engineer-in-Charge.
M&L for MCB SPN 40 Amps 240 volt,C' curve,10KA including taking down unserviceable MCB complete all as directed by Engineer-in-Charge.
M&L for MCB SPN 63 Amps 240 volt,C' curve,10KA including taking down unserviceable MCB complete all as directed by Engineer-in-Charge.
M&L for MCB SP 06 to 40 Amps 240 volt,C' curve,10KA including taking down unserviceable MCB complete all as directed by Engineer-in-Charge.
S&F cable 2 core PVC insulated unsheathed multistranded copper conductor of size 1.5 Sq mm in replacement passing through PVC conduit from junction box to fitting incl PVC conduit including taking out old unserviceable cable complete all as directed.
S&F cable 3 core PVC insulated unsheathed multistranded copper conductor of size 2.5 Sq mm in replacement passing through PVC conduit from junction box to fitting incl PVC conduit including taking out old unserviceable cable complete all as directed.
S&F cable 3 core PVC insulated unsheathed multistranded copper conductor of size 4 Sq mm in replacement passing through PVC conduit from junction box to fitting incl PVC conduit including taking out old unserviceable cable complete all as directed.
S & F Replacement of unserviceable wire of size 1.5 Sqmm with PVC insulated FRLS multistranded copper conductor for working Voltage 1100 Volts single core of 1.5 Sqmm .
All as per item No 55 here in before but of size 2.5 Sqmm.
All as per item No 55 here in before but of size 4.0 Sqmm.
All as per item No 55 here in before but of size 6.0 Sqmm .
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_837444.xls
BOQ • 0.34 MB
Tenderdocument.pdf
Tender Documents • 1.23 MB
Download all tender documents and submit your bid