Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC 4 13A PERIYAR NAGAR THANGAMAPURIPATTANAM METTUR DAM 636 402 SALEM DT TAMIL NADU | METTUR DAM | SALEM | TAMIL NADU | 636402 | ₹2.5 L Quoted ₹2.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.6 LRejected-AOC NO 42 PERIYAN NAGAR THANGAMAPURIPATTINAM METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | ₹2.6 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | ANNAI ENTERPRISES L1 | T S CONTRACTOR L2 |
|---|---|---|---|---|---|
| 1.00 | 4 Ton cassette type AC unit:
Charges for Yearly complete servicing of 4.0 Ton capacity Cassette type Split AC unit by dismantling the filter, indoor unit cover, blower fan, blower motor and thorough cleaning, reassembling the same and thorough cleaning & water washing of outdoor unit and to check the terminal tightness in the terminal block and commissioning. | 10 | Nos | 4,200 ₹42,000 Lowest | 4,500 ₹45,000 |
| 2.00 | Charges for Half Yearly servicing of 4.0 Ton capacity Cassette type Split AC unit by dismantling the filter, thorough cleaning, reassembling the same and thorough cleaning of outdoor unit and to check the terminal tightness in the terminal block and commissioning. | 10 | Nos | 2,290 ₹22,900 Lowest | 2,500 ₹25,000 |
| 3.00 | Charges for checking of gas leakage by pressure holding by N2 gas, attending the defect in the copper pipe line/joint, vacuumizing and filling of suitable Refrigerant gas in 4.0 Ton capacity Cassette type Split AC and commissioning. | 2 | Nos | 3,040 ₹6,080 Lowest | 3,200 ₹6,400 |
| 4.00 | Charges for checking of gas leakage by pressure holding by N2 gas, (no leak in the external copper pipe line), then dismantling the filter, indoor unit cover, indoor unit, transported to safe location, pressure holding by N2 gas in the indoor unit, identify the leak location, carry out necessary brazing work, reassembling the indoor unit in the cassette, vacuumizing and filling of suitable Refrigerant gas in 4.0 Ton capacity Cassette type Split AC and commissioning. | 2 | Nos | 3,150 ₹6,300 Lowest | 3,300 ₹6,600 |
| 5.00 | Charges for dismantling the indoor unit cover of 4.0 Ton capacity Cassette type Split AC unit, identify the water leak & rectify the same and reassembling the indoor unit cover and commissioning | 2 | Nos | 2,290 ₹4,580 Lowest | 2,400 ₹4,800 |
| 6.00 | Charges for identifying the circuit fault and replacing the single pole contactor in the outdoor unit and to check the terminal tightness in the terminal block in 4.0 Ton capacity Cassette type Split AC unit and commissioning | 2 | Nos | 2,290 ₹4,580 Lowest | 2,400 ₹4,800 |
| 7.00 | Charges for identifying the abnormal sound in the outdoor unit by checking the blower fan condition or bearing condition of blower motor and replacement of defective fan or replacement of blower motor in 4.0 Ton capacity Cassette type Split AC unit and commissioning | 2 | Nos | 2,680 ₹5,360 Lowest | 2,800 ₹5,600 |
| 8.00 | 2.0 Ton capacity Split AC unit
Charges for yearly complete servicing of 2.0 Ton capacity Split AC unit by dismantling the filter, indoor unit cover, blower fan, blower motor and thorough cleaning, reassembling the same and thorough cleaning & water washing of outdoor unit and to check the terminal tightness in the terminal block and commissioning | 21 | Nos | 1,790 ₹37,590 Lowest | 1,850 ₹38,850 |
| 9.00 | Charges for Half Yearly servicing of 2.0 Ton capacity Split AC unit by dismantling the filter, thorough cleaning, reassembling the same and thorough cleaning of outdoor unit and to check the terminal tightness in the terminal block and commissioning. | 21 | Nos | 625 ₹13,125 Lowest | 700 ₹14,700 |
| 10.00 | Charges for checking of gas leakage by pressure holding by N2 gas, vacuumizing and filling of suitable Refrigerant gas in 2.0 Ton capacity Split AC and commissioning. | 4 | Nos | 1,030 ₹4,120 Lowest | 1,100 ₹4,400 |
Tender Value
Refer Docs
EMD Value
₹2,200
Closing Date
14 Nov 2025, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER MTPS-I METTUR DAM
MTPS-I ES Circle EM-I AC plant Yearly maintenance Half yearly maintenance Breakdown works in 4.0 ton cassette type ceiling mounted 2.0 ton split type wall mounted AC units in EM-I division for a period of 12 months from the date of Commencement of
2025_EB_618763_1
CE-MTPSI-SE-ES-EMI-OT100-25-26
Open Tender
Electrical Works
Works
365 days
MTPS-I/METTURDAM
AS PER TENDER SPECIFICATION
4 documents required · 4 mandatory
₹0
₹2,200
Yes
15 Jul 2026
30 Oct 2025
15 Nov 2025
30 Oct 2025
14 Nov 2025
30 Oct 2025
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
BOQ_739709.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].