| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC D 1 KHOTTA TOLA KUNGRAGHAT GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹37.2 L+₹78,610 (2.16%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹37.4 L+₹1.1 L (2.93%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | Rejected-Technical BR GADGIL ROAD PUNE MAHARASHTRA 411030 INDIA | PUNE | MAHARASHTRA | 411030 | - | Rejected-Technical Not Fullfil the criteria as per NIT |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
14 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR
SPECIAL REPAIR TO BLDG NO 85 AND PROVN OF STORE AND ALLIED WORK AT VIJAY VIHR AT AF STN GORAKHPUR
2022_MES_570543_1
8957/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
Class D Cat a i
8 documents required · 8 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹97,000
Yes
29 Mar 2023
21 Dec 2022
16 Jan 2023
21 Dec 2022
14 Jan 2023
2 Jan 2023
21 Dec 2022 - 31 Dec 2022
Amount
Demolition of brickwork built in cement mortar including quoins, arches, pillar etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4, all as specified and directed.
M&L for rendering 15mm thick on faces of brick work or concrete surfaces CM 1:6, and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on faces of brick work or concrete surfaces CM 1:4, and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick on faces of brick work or concrete surfaces CM 1:3, as in ceiling, and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling & applying two coat white wash complete as specified.
M&L preparation of old surfaces of ceiling & applying one coat of white wash complete all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coats of oil bound distemper including 1mm thick birla white wall care putty complete all as specified and directed.
M&L for preparation of new surface of wall and applying two coats oil bound distemper over and including 1mm thick birla white wall care putty complete all as specified and as directed..
M&L for preparation of old plastered surface of wall and applying two coat coat of weather coat paint Apex over a coat of alkali resistant primer complete all as specified.
M&L for preparation of new plastered surface of wall and applying two coat coat of Apex weather coat paint over a coat of alkali resistant primer complete all as specified.
Taking down chowkat or frames not exc. 1.5 sqm each with shutters (without taking off shutters from frames) Complete all as specified and directed at site.
Taking down chowkats with shutters exceeding 1.5 Sqm but n. exc 4 sqm each ( without takig off shutters from the frames) Complete all as specified and directed at site.
M&L for preparation of new surfaces of steel and applying two coat of synthetic enamel paint over a coat of red oxide Complete all as specified and directed at site.
M&L for preparation of old surfaces of steel and applying one coat of synthetic enamel paint Complete all as specified and directed at site.
Dismantling of stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floor,wall, aprons etc complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 350 x250 x7mm / 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles including rendering 10 mm thick on faces of brick or concrete surfaces in cm 1:3 complete all as specified and directed.
M&L Non-skid ceramic coloured tiles 7 to 8 mm thick ( square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured of tiles including laying of screed bed or bedding layer of mortar 15mm thick in cm 1:6 Complete all as specified and directed at site.
M&L for 20mm thick granite stone (any type of work) in steps, jambs, pillars, cooking platform and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for chamfers, splays or arris of granite in face work exc. 15mm but n. exc 50 mm wide complete all as specified and as directed.
Taiking up or down steel tubing and connections, 15 mm bore complete all as specified and directed.
Taking up or down steel tubing and connections, 20 mm bore complete all as specified and directed.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubings, cutting not exceeding 10cm girth complete all as specified and directed.
M&L for GI tubing 15 mm bore 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for GI tubing 20 mm bore 'medium grade' galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs wash basin, Vitreous China white flat back of size 550x400mm including 32mm bore Chromium plated waste fitting cutting for and pinning in ends of brackets or erecting stand but excluding taps, waste, chain and plugs and porcelain stopper but including brackets.Complete all as specified and directed at site.
S&F in repairs bottle trap of PTMT having minimum water seal of 25mm (min weight 32mm-260gms/ 40mm 270gms) Complete all as specified and directed at site.
S&F in repairs brass chromium plated tubular towel rail 20mm dia 600 mm long, fixed complete all as specified and as directed.
Taking down rain water / vent pipe of any description including fittings etc. including removal to store, complete all specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall or laid in floors.Complete all as specified and directed at site.
S&F 110mm bore PVC (SWR) bends, of any radius provided without access door.Complete all as specified and directed at site.
S&F 100mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including securing ends of stays to wall or roof Complete all as specified and directed at site.
Supply and fixing in repairs 75mm dia outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all specified and directed.
S&F in repair kitchen sinks with drainage board overall size 915mm x 460mm bowl size 410mm x330mm x116mm, made of stainless steel 1 mm thick with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to waste pipe and coupling complete all as specified and directed.
Supply and fix in repairs cast copper alloy chromium plated fancy type angle cock, of 15 mm bore complete all as specified and directed.
S&F in repairs gun-metal gate valve 20 mm bore, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete.
S&F in repairs fancy type, chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15 mm bore complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repairs 15 mm bore pillar tap fancy type cast copper alloy chromium plated screwed down high pressure with or without lettered ' Hot' or 'Cold' with long screw shanks screwed for iron pipe or union Complete all as specified and directed at site.
Dismantling water tanks capacity exc 250 but n. exc 500 Ltrs complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks white colour tripple layers with thread type locking cover arrangement, 500 ltrs (cylindrical vertical with closed top ) hoisted and fixed in position Complete all as specified and directed at site.
S&F Ball valves high pressure, with polythene float and fly nut complete, screwed for iron pipe 20 mm bore or brass ferrule and fixed Complete all as specified and directed at site.
M&L in repairs Framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cooler stand and other similar work.Complete all as specified and directed at site.
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete in ground floors and paving n. exc 15cm thickness (below or above GL) complete.
M&L for 75mm thick cement concrete type C-2 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection finished surface even and smooth without using extra cement.Complete all as specified and directed at site.
Dismantling of brick tiles or terracing tiles single layer bedded in cement mortar on roof complete all as specified and directed.
Demolition of cement concrete in roof including plastering and leeping including cleaning surface of roof with wire brush / mechanical brush throughly to remove old dirt / loose particles to expose clean concrete slab clean with watering etc complete all as specified and directed.
M&L for cutting out cracks to V section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry in 1:3 complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.50mm graded stone agg with WPC as in padding to maintain proper slope as required complete all as specified and directed. (WPC shall be paid separatly.)
M&L rendering 15 mm thick in cement mortar 1:4 over PCC bedding with water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified directed.
Supply only Water proofing compound Make Dr fixit LW+ or equivalent.Complete all as specified and directed at site.
M&L for priming over roof surface @ 0.25 Ltr/Sqm over a cleaned roof surface and applying one coat of bitumen painting with hot blown grade bitumen 85/25 @ 1.20 Kg/ sqm and fixing minimum 3mm thick reinforced with polyester non wove fabric ( wt not less than 150gms/ sqm) on primed surface by forced application complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in roof kerb / benching in radius 10 cm with waterproofing compound as per manufacturer's instructions complete all as specified and directed.
M&L for 25mm thick size 300x300mm concrete tiles laid over screed bed in cement mortar 1:6, jointed & pointed in CM 1:3 Mixed with crude Oil @ 5 % by weight of cement complete all as specified and directed.
S&F in repairs fancy type, chromium plated long body bib taps, for kitchen sink cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15 mm bore complete all as specified and directed.
M&L powder coated anodised aluminium doors (sliding/hanging type) with frame size 101.60X44.45X 2.00 mm thick and shutter aluminium anodised and top rail 47.62X 44.45 X 1.50mm and style 47.5 x 44.5 x1.5 mm , lock rail 83.50X 44.45 X 1.50 mm and bottom rail150.00X 44.50 X 2.50 mm incl necessary aluminium fittings like aluminium butt hinges 04 Nos , aluminium handles 150mm 02 Nos,aluminium tower bolts 200mm 01No, mortice lock 4 lever MS, hydraulic door closer of suitable capacity 01 No, aluminium door stoper 01 Nos, jointing cleats,glazing cleats,rubber packing , anodised aluminium shape beading, screws etc with panelling in two parts with 12mm thick prelaminated partical board in lower panel and 5mm thick tinted glass in upper panels incl all fittings& fixture complete all as spesified and directed.
M&L powder coated aluminium (sliding/ hanging type) windows/ventilator with frame size 60x40x2.00mm thick and shutter with section bearing bottom 25x18x1.50, top 39.4x17.7 X1.50 mm ( suitable for moving over three track fixed over top of frame work , top and side section of size 61.6 x 31.75x1.5mm and bearing bottom track of size 61.6x 31.75x1.5mm or fixing with hinges steel wire cloth 0.36mm nominal dia of wire and average width of aperture1.4 mm including necessary aluminium jointing cleats, glazing cleats, rubber packing anodised snape beading, screws etc with 4 mm thick tinted/ plain glass in panels incl anodised aluminium grill with all fittings & fixture complete all as spesified and directed .
M&L for stainless steel of 304 grade for frame work for railing and for decorative work complete all as specified and directed.
S& F in repairs for rolling shutters with 1.0mm thickness of laths, out ball bearing as specified including top cover, anchoring rod hasp and staple and one shop coat of primer erected complete push pull or manual type Complete all as specified and directed at site.
S&F safety lever locks mild steel with 4 levers for rolling shutters Complete all as specified and directed at site.
S&F ball bearing for rolling shutters complete all as specified and directed at site.
M & L for powdered coated aluminium grid system for aluminium composite panel and including necessary suspender and fastening arrangement achevied required finished smooth shape and designing for panelling complete all as specified and directed.
M & L for 5 mm thick coloured aluminium composite panels for wall cladding including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, shape and colour complete all as specified and directed
Excavation in trenches in any kind soil not exceeding 1.5 metre wide & not exceeding 1.5 metre depth for foundation etc and getting out, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed
Removing excavated material to a distance exc 250M and deposited where directed at a level n. exc 500 M above the starting point complete all as specified and as directed.
M/L PCC type D2 1:4:8 (40 mm graded aggregate) as in foundation complete all as specified and as directed.
Excavation in post holes ( or similar holes) in soft/loose soil each n. exc 0.50 Cum getting out, watering and removing surplus soil to a distance n. exc 50 m and making good surface complete all as specified and directed.
M&L for PCC 1;2:4 type B1 using 20mm gragded stone aggregate for post hole
M&L for angle iron post and struts including cutting tops to shape as directed, drilled holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.)including all necessary drilling,bolting or riveting screws, etc and similar work complete all as specified
S&F expended metal cut to length bent to shape required and tying with incl. Annealed maild steel wire not less than 0.9 mm dia or fixing with galvanised steel steples and weight exc. 4Kg /sqm etc all as specified.
M&L for Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50nn thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping scews as specified.
M&L for 100mm thickcement concrete (1:4:8) type D2 in foundations filling, sub base and mass concrete all as specified and directed at site.
S & F in repair suspended false ceiling with "E" grid suspended ceiling grid system of grid size 600 x 600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24 x 0.3mm using 4mm thick high pressure steam cured classic variant E-Board, designer pattern to be placed in the grid suspended by 2mm dia GI wire at distance n. exc 1.2m center to center with butterfly clips including preparation of surface and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L in repairs reinforced cement concrete (nominal mix) type B1 1:2:4 (20 mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, copies, deck slabs and in shelves complete all as specified and directed.
Use and waste of form work (flat) to rough finished surfacesides and soffits of floor and roof beams, cantilevers, shelves, columns etc complete all specified and directed.
S&F for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete, all specified and directed.
M&L Mild steel TMT bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed at site.
M&L for preparation of new surfaces of steel and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out hard/dense soil complete all as specified and directed at site.
M&L Hard core of guage Broken stone or boulders nexc 63mm,deposited,spread and levelled in layers n exc15cm thick watered and rolled/rammed to a true surface complete all as specified and directed at site.
M&L for cement concrete (1:4:8) type D2 in foundations filling and mass concrete complete all as specified and directed at site.
M&L 60mm thick Machine pressed precast concrete interlocking paver block (Coloured) any shape and size conforming to IS 15658 -2006 M-35Grade.complete all as specified and directed at site.
M&L 30mm thick sand cussoioning under interlocking tiles complete all as specified and directed at site.
Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M&L for concealed point wiring for one light/fan point controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. Note:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
All as per item No. 89 above but for one 5 Amps socket point controlled by one 5 Amps switch on independent board.
All as per item No. 89 above but for one 5 Amps socket point controlled by one 5 Amps switch on same board.
M&L for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of GI terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete for 3/6 pin 15 Amps socket outlet on independent board complete all as specified and directed. Note:-(i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, shall be measured and paid separately.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 15 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type 230 volt complete all as specified and directed.
S&F socket outlet, flush type, 2 in 1, 3 pin 5 & 15 Amps, 230 Volts, multipurpose complete all as specified.
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
S&F 22 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS22WLED865SPCWH or equivalent in Bajaj / CG.
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED street light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:- Havells Cat No. ENDURA CITYLITEPLAT PLUSSL35W LED 757SASYBOPC or equivalent in Bajaj/ Philips/ CG/ WIPRO
Supply & fixing brackets made out of 40/50mm dia medium grade GI pipe 1.50 mtr long bent to shape and size fixed on location using new 2 nos 30x5mm FI clamps duly painted made to shape incl nuts, bolts & washers with 2 coat of aluminium paint complete all as specified and directed
Taking down old unserviceable MCCB DBs / MCB DB / Main Switches complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 4 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
Taking down old unserviceable MCCB / MCB SP/SPN complete all as specified and as directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TPN, 40 to 100 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing capping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed.
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 4 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable PVC conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 4.0 sqmm conductor cable, 1 No 4 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing complete.
S&F Exhaust fan single phase 230/240 volt AC 450mm sweep, with painted louvers, metal body, including cutting holes of suitable size in wall, grouting of nuts and bolt etc if required for fixing fan and making good to match the existing surface and making connection with twisted copper flexible wire 23/0.0076mm complete all as specified and directed.
S&F wall mounted fan complete metal body and copper winding fan motor, 230 volts, 50Hz, single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed. Make:- Bajaj Model Supreme plus or equivalent model of specified make
S&F ceiling fan complete with all electronic fan regulator and accessories of capacity 230V, 1200 mm sweep, BEE 5 star rating complete all as specified and directed withn suitable copper conductor cable for connection. Make: Havells, Model No. ES 50 Premium 5 or equivalent in Bajaj/ Crompton.
Disconnecting, taking down & removing carefully the existing ceiling fan, etc. of any description, any sweep and from any position/locations for and making necessary adjustment and proper alignment of blades, hanging/fixing the fans in position after fixing of anti suicide down rod, connecting to existing electric sources with suitable ssize of cable and testing at site to the entire satisfaction of the department complete all as specified and directed.
Supply & Fixing in replacement down rod with anti sucide safe fan down rod, 250mm length suitable for fixing in exiting ceiling fan complete with nut , bolt and washer , duly finished with powder coating of white colour, including necessary holes by drilling and threading etc. complete all as specified and directed.Make: Gold life Note: Anti sucide safe down rod will be active if load on fan cxceeded 20 kg, then down rod pip opens for middle and spring in pipe will expanded for landing smoothly for person trying to commit sucide.
Supply & Fixing in repairs , laying and testing 25 Sqmm, 4 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
S&F 40mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Taking down and refixing of electric meter in same position and making good to disturbed surface complete all as spfd.
M&L for in replacement earthing with Galvanised iron earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal GL) with top of earth plate not less than 1.5 mtr below GL connected to to GI lead wire4mm dia & connected to earth plate electrode by means of GI nuts, bolts, and washers with and incl, PCC 1:3:6 type C-1 pit with cover of RCC 1:2:4 type B-1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20mm dia GI medium grade pipe, GI funnel with GI mesh, filling with mixture of common salt and charcoal, necessary excavation and earth work in any type soil, including test point, testing and commissioning complete all as specified and directed. Note: (i) Earth resistance should be less than 3 Ohm. (ii) GI strip upto 7.5 mtr will be included in quoted rate.
Supply & laying and testing 25 Sqmm, 4 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
S&F 20mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
S&F MCCB, 4 pole, 100 Amps, 26 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
Supply and Installation of Smart Cellular Single Phase Meter with the following specifications: (i) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Cellular Modem with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. (ii) Meter Should support sending the following data : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software (iii) Meter should have connect / disconnect functionality operable from billing software (iv) The meter should support open communication protocol DLMS with the software MAKE:L&T (cat part no WM101BC7DSM4GINN+B10) or equivalent in Secure or Schneider/elmeasure Notes: (i) Meters will be 5 years OEM Warranty (ii) Meters will be include 2 years cellular recurring charges
Supply and configuration of the Web based Software per meter with following modules: (i) Meter Data Management Module The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data: (a) 15 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency (b) Monthly billing survey data for cum energy and max demand (ii) Billing Module The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. The system would be setup as postpaid billing system. It would allow postpaid and prepaid functionality as required.(iii) Occupation and Vacation Module The system would support occupation / vacation and billing reports. the software would be collecting data from DCU. The software would provide access to staff as well as the occupant for the data. (iv) Web site: There would be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to the application. The MES staff would also have the access of the key information on an android mobiles app (for admin use). (v) Customer Portal The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis. (vi) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (vii) Communication Module The system would provide communication of energy data and bills via print, email and SMS methods. (viii) Meter Master Data:-The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export:- The system would support export of metering and billing data in excel format. (x) Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. (xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email. Make: Authorised by meter vendor. Note:(a) The software would be hosted on MEITY (Ministry of Information Technology) approved GCC (Government Community Cloud) or on MES server as provided. (b) One payment gateway would be installed provided a bank account is opened at GE level (c) The software ans system would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc.
sri krishna construction
M/S SHAILZA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .