Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.1 L+₹3.9 L (16.8%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹28.1 L+₹4.9 L (21.1%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L3 | Rejected-Finance NOT BEING L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
9 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Kalaikunda
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR AND MAINTENANCE OF SUMMER AND COOLING APPLIANCES AND OTHER CONNECTED WORKS IN KALAIKUNDA AIR FORCE STATION
2020_MES_386863_1
8605/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) Kalaikunda
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Kalaikunda
₹40,000
Yes
22 Mar 2021
16 Oct 2020
11 Dec 2020
16 Oct 2020
9 Dec 2020
14 Nov 2020
60 days
Amount
Comprehensive servicing for Window Type Air Conditioner of any make and capacity installed at various location by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration including cleaning of condensor & evaporator coils fins with mild detergent and descaling of condensor coil for window etc. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.
Comprehensive servicing for Split Type Air Conditioner of any make and capacity installed at various location by carrying out necessary repairs,cleaning of filters, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration ncluding cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for window etc. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. (NOTES:- (Applicable for BOQ Serial Item No. 1 to 2 here in before) (i)S&F spare parts will be measured and paid separately under relevant item.) (ii) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of Air Conditioners including maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipment manufacturer's instructions and as specified in Particular Specification. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) KALAIKUNDA officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period including defect liablity period . (iv) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (v) Cost of minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (vi) Spares required for replacement of defective ones will be measured and paid seperately .
M&L for Shifting of split type AC by taking out AC from MES yard or from existing location to the new location by taking it after taking down, closing the opening of old location with cement mortar cement mortor(1:3) ,white wash to match with the existing colour of the site & making holes in brick wall at new location and fine finishing with cement mortar white wash etc to match with the existing colour of the site installation & commissioning after replacement of insulation of suction & dischare line,charging,electrical connection only. Note:- (i) S&F insulation ,copper tube ,gas and other spare parts will be measured and paid separately under relevant items. (ii) Existing/ new location will be in Technical or Domestic area as per site requirement.)
M&L for Shifting of Window AC by taking out AC from MES yard or from existing location to new location & installation of window type AC by making necessary opening in brick wall/window for and preparing gap well finished by cement morter,white washing or as per existing specification to match with the existing colour, disposal of waste material, including covering of gap with ply wood and beeding work to cover the four side at front of AC & outer surface of plywood required to be painted with two coats of enamel paint over a coat of primer on plywood to match the existing location in all as directed by the Engr-in-charge. Note:- (i) S&F insulation ,copper tube ,gas and other spare parts will be measured and paid separately under relevant items. (ii) Existing/ new location will be in Technical or Domestic area as per site requirement.) Ply wood shall be measured and paid seperately.)
Supply and fixing in replacement of Printed Circuit Board suitable for 2TR Capacity Split Unit Air Conditioners including remote, as per OEMs specifications, complete suitable for existing type etc all as directed by Engr in charge .
Supply and fixing in replacement of Printed Circuit Board suitable for 1.5 TR Capacity Split Unit Air Conditioners including remote, as per OEMs specifications, complete suitable for existing type etc all as directed by Engr in charge .
S&F in repair Rotary compressor suitable for Split / Window AC of capacity 1.5 TR, suitable for R-22/R-32 gas, 220-240 volts, single phase, 50 Hz. as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F Rotary compressor suitable for Split / Window AC of capacity 2 TR suitable for R-22/R-32/R-410 gas, 220-240 volts, single phase, 50 Hz. as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F in repair Reciprocating compressor suitable for Split / Window AC of capacity 1.5 TR. suitable for R-22/R-32/R-410 gas, 220-240 volts, single phase, 50 Hz. as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F in repair Reciprocating compressor suitable for Split / Window AC of capacity 2 TR suitable for R-22 gas, 220-240 volts, single phase, 50 Hz. as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
Supply & filling R-22 gas for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge. (Contractor shall be check leakage in the system before filling of gas).
Supply & filling Nitrogen gas for vaccum for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge.
Supply & filling R-32 gas for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge.(NOTE:Contractor shall be check leakage in the system before filling of gas).
Supply & filling R-410 gas for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge. (Contractor shall be check leakage in the system before filling of gas).
S& F Magneting Relay coil for AC's as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F Rubber bush for indoor motor of AC's as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
S&F Air filter for Split type AC's ( suitable for AC of capacity 1.5/2 TR) as per OEMs specifications, complete all as specified and directed NOTES: (i) Repairs woks shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L for rewinding/ repairing of blower fan motor of AC of capacity 1.5/2 TR Window AC by disconnecting the electrical connection of burnt out electric outdoor motor and dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Repairs and rewinding woks shall be carried out through authorised technicians of the OEMs as approved by GE for motor of suitable capacity including removal and re-fixing of the same complete all as specified and dierected by the Engineer -in-charge.
M&L for rewinding/ repairing of blower fan motor of AC of capacity 1.5/2 TR Split AC by disconnecting the electrical connection of burnt out electric outdoor motor and dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Repairs and rewinding woks shall be carried out through authorised technicians of the OEMs as approved by GE for motor of suitable capacity including removal and re-fixing of the same complete all as specified and dierected by the Engineer -in-charge.
Supplying and laying in replace of CPVC pipes SDR 11 & plain CPVC SDR 11 of 40 mm dia fittings with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, including clamps and all fittings and fixtures complete all as specified.Make Supreme/Prince.
All as per item No-20 above but here in before but of size 25 mm dia. complete all as specified Make Supreme/Prince.
All as per item No-20 above but here in before but of size 20 mm dia. complete all as specified Make Supreme/Prince.
Supply and fixing in repair anti corrosive outdoor bracket for split type AC with aluminium hexagonal screws and all fittings as per OEMs specifications, complete all as specified and directed
S&F in repair Capacitor aluminium body 45 Mfd 450 VAC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 55+4 Mfd 450 VAC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 45+4 Mfd 450 VAC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 60+6 Mfd 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 60+4 Mfd 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 36 Mfd 450 V AC 50 HZas per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 50 Mfd 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 45 Mfd +6 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 36 Mfd +6 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 50 Mfd +6 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor aluminium body 4 Mfd ±5% 440 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor PVC 1.5 Mfd rectangular type,±5% 440 V AC 50 HZas per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 3.15mfd,±5% 220V,AC as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 2mfd,±5% 220V ,AC as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor 70 Mfd +6 450 V AC 50 HZ as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Starting capacitor 80/100 mfd, 440 V AC, as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Starting capacitor 100/120 mfd, 440 V AC,as per OEMs specifications, complete.Make - GC/Universal/Havells/Epcos/Tibcon
S&F in repair Strainer two way/single way as per OEMs specifications, complete.
Supply & fixing in repair blower motor, 220-240 V, 50 HZ,30-80Watt(as per existing), 4 pole insulation class -B, IP22 as per sample suitable for window AC of any make and 1.5/2 TR capacity.(Contractor shall provide the new motor of reccommended make of OEM of AC in which it has to be fixed, Make of AC : LG/Carrier/Samsung/Amtrex / Videocon / Hitachi/ Blue star any make. Before procurement he will take the approval from Engr-in-Charge for make and model.
S&F in repair Potential relay suitable for Window type AC 1.5 /2.0 TR as per OEMs specifications, complete.
S&F in repair Condenser coil copper for suitable for Window type AC 1.5 /2.0 TR. as per OEMs specifications, complete.
S&F in repair Fan Blade suitable for Window AC type AC 1.5 /2.0 TR as per OEMs specifications, complete.
S&F in repair Fan Blade suitable for Split type AC outdoor 1.5 /2.0 TR as per OEMs specifications, complete.
Supply & fixing in repair blower motor, 220-240 V, 50 HZ,30-80Watt(as per existing), 4 pole insulation class -B, IP22 of indoor unit as per sample suitable for Split type AC of any make and 1.5/2 TR capacity.(Contractor shall provide the new motor as per OEMs specifications, complete. Make of AC : LG/Carrier/Samsung/Amtrex / Videocon / Hitachi/ Blue star . Before procurement he will take the approval from Engr-in-Charge for make and model.
S & F in repair single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top, complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
S&F in repair 20 Amp three pin top metal clad suitable for industrial socket, Make-Havells (Crabtree)/Anchor/Legrand.
S&F in repair Condenser coil copper for split type AC 1.5/2 TRas per OEMs specifications, complete.
Supply & fixing in repair blower motor, 220-240 V, 50 HZ,30-80Watt(as per existing), 4 pole insulation class -B, IP22 of outdoor unit as per sample suitable for Split type AC of any make and 1.5/2 TR capacity.(Contractor shall provide the new motor as per OEMs specifications, , Make of AC : LG/Carrier/Samsung/Amtrex / Videocon / Hitachi/ Blue star any make. Before procurement he will take the approval from Engr-in-Charge for make and model.
S&F in repair Remote suitable for split type AC 1.5/2 TR indoor unit as per OEMs specifications,
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations Water Cooler of any make and capacity installed at various locations by carrying out necessary repairs, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration etc. through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, including refixing the same at the location where directed including making/connecting of water and electric connection complete all as specified and dierected. Make of water cooler : Voltas/Bluestar/Shriram/Videocon or any make.
Supply & fixing in repair Potential relays suitable for Water cooler of any make and capacity as per OEMs specifications,
S&F in repair motor assembly of 220-240 V, 50 HZ,30-80Watt(as per existing), 4 pole insulation class -B, IP22 of as per sample suitable for suitable for Water cooler of any make .(Contractor shall provide the new motor as per OEMs specifications, in which it has to be fixed, Make of water cooler : Voltas/Bluestar/Shriram/Videocon or any make. Before procurement he will take the approval from Engr-in-Charge for make and model.
S&F in repair Door Gasket suitable for Water cooler of of any make and capacity as per OEMs specifications,
S&F in repair Magnetic relay suitable for Water cooler of any make or capacity. as per OEMs specifications,
S&F in repair Thermostat switch complete suitable for Water cooler of any make and capacity as per OEMs specifications,
S&F in repair Connection pipe suitable for Water cooler of any make and capacity as per OEMs specifications,
S&F in repair Push Tap suitable for Water cooler of any make or capacity.As per sample
S&F in repair Drain pipe for suitable for Water cooler of any make and capacity as per OEMs specifications,
S&F in repair Chromium plated L type/push type self closing tap of stainless steel of any make and capacity as per OEMs specifications,
S&F in repair Compressor for water cooler as per sample as per OEMs specifications,
S&F in repair Capacitor aluminium body 6 Mfd ±5% 440 V AC 50 HZ as per OEMs specifications, Make -GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 10mfd,±5% 220VAC as per OEMs specifications, Make -GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 12mfd,±5% 220VAC as per OEMs specifications, Make -GC/Universal/Havells/Epcos/Tibcon
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations 165 to 340 Litres capacity refrigerators installed at various locations by carrying out necessary repairs,adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration etc. through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed. [Make: LG/Voltas/Godrej/Kelvinator/Whirlpool/Blue Star]
Supply & fixing in repair Condenser coil suitable for Refrigerator of any make and capacity as per OEMs specifications
S&F in repair Cooling coil with door and frame suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Thermostat switches suitable for Refrigerator of any make and capacity:of any make and capacity as per OEMs specifications
S&F in repair Gasket set complete suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Chiller tray suitable for Refrigerator of any make and capacity:Make - as per sample. Make - as per sample
S&F in repair Potential relay suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Drier suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Bulb thread/pin type suitable for Refrigerator of any make and capacity of any make and capacity as per OEMs specifications
S&F in repair Bi-Metal with timer suitable for Double door Refrigerator of any make and capacity as per OEMs specifications
S&F in repair Grills for keeping products suitable for Refrigerator of any make and capacity as per OEMs specifications
S&F in repair Compressor suitable for refrigerator 1/8 as per OEMs specifications Make:- Godrej/Tecumseh/ Emerson.
S&F in repair Compressor suitable for refrigerator 1/6 as per OEMs specifications Make:- Godrej/Tecumseh/ Emerson.
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of any capacity and make Deep Freezer installed at various locations by carrying out necessary repairs, adjustments of assemblies, sub-assemblies, check the level of refrigerant, arresting the leakage of any type, replacement of parts, calibration etc. through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE, complete all as specified and directed. NOTES:- (Applicable for BOQ Serial Item No. 54 to 85 here in before and here in after ) (i) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of Refrigerator/Deep Freezer/Water Cooler. (ii) Preventive and Corrective Maintenance This includes maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipment Manufacturer's instructions and as specified in Particular Specification. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from officials or their representatives.The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service to the machinary/equipments during comprehensive maintenence period. The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contract (v) Cost of minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (vi) Spares required for replacement of defective ones will be measured and paid seperately
Supply & fix in repair Condensor Motor suitable for Deep freezer of any make and capacity as per OEMs specifications
Supply & fix in repair Condensor coil for deep freezer as per OEMs specifications
Supply & fix in repair Fan Blade for deep freezer as per OEMs specifications
Supply & fix in repair Compressor suitable for Deep freezer as per OEMs specifications
Material and labour for sub main wiring wth 2 runs of 4 sq. mm. (Phase & Neutral ) and one run of 4Sq. mm. for earth contunity conductor PVC insulated unsheathed FRLSH grade cable with copper conductors multi stranded 1100 V grade confirming to IS-694 drawn through and including surface PVC casing caping of suitable size, with accessories all as specified and as directed by Engineer -in-charge. NOTE:- (a) 2 runs of 4 Sq.mm. + 1 run of 2.5 Sq.mm. cable for earth + 1 run of casing caping shall be measured as one unit leangth
M&L for point wiring one 3 pin socket ,15 Amps, Independent, with cable 4 sq mm size single core multi standered FR grade copper conductor unshethed PVC insulated 1100V grade cable drwan into and including PVC casing caping with accessories and fitting like bend, elbows, crosses wall crossing etc. with sunken type pressed steel box width 3mm thick plastic laminated sheet top cover of approved make for housing switches, sockets outlet and regulators and with continueus 1 No cable 4 Sq.mm. stranded copper conductor PVC insulated, unshethed FR grade as earth wire connected to earth dolly and to be cconnected boxes of suitable sizes for mounting to fittings etc, with necessary cutting / chasing of wall/ ceiling complete all as specified and as directed for one light point controlled by one switch.
Supply & fixing in repair flexible PVC Water drain pipe suitable for Split AC (upto 5/8 PVC pipe) as per OEMs specifications
S&F in repair Copper refrigerent piping size 1/4" suitable for cooling appliances as per OEMs specifications
S&F in repair Copper refrigerent piping size 1/2" suitable for cooling appliances as per OEMs specifications
S&F in repair Copper refrigerent piping size 5/8" suitable for cooling appliances as per OEMs specifications .
S&F in repair Copper refrigerent piping size 3/8" suitable for cooling appliances.as per OEMs specifications
S&F in repair Capillary tube suitable for cooling appliances.as per OEMs specifications
S&F in repair MCB SP 6-32 Amp, 10 KA, 'C' characteristic make: L&T/Legrand/ABB.
Supply only Soldering stick superior quality as per OEMs specifications
S&F in repair PVC insulated PVC sheathed 2.5 sqmm Size 3 core copper cable . Make:-Havells/Plaza/ Finolex.
S&F in repair Nitrile Rubber insulation for AC pipe of size 5/8".as per OEMs specifications
S&F in repair Nitrile Rubber insulation for AC pipe of size 1/4".as per OEMs specifications
S&F in repair Flare Nut of any size (upto 1 inch) as per OEMs specifications
S&F in repair Overload Protector.as per OEMs specifications
Supply & charging 134A gas to maintain the required cooling effect as and when required in the Water cooler/Refrigerator charging (Charging costincluding in this item.)
M&L LPG butane gas cartridge of capacity 230 gm for soldering. as per OEMs specifications
S&F in repair overload relay for water cooler of any capacity and make as per OEMs specifications
S&F in repair overload relay for Refrigerator of any capacity and make as per OEMs specifications
S&F in repair for Non return valve for charging gas of any capacity and make as per OEMs specifications
M&L for repair of PCB Kit for AC/Water cooler/Refrigerator of any capacity and make as per OEMs specifications
S&F in repair Drain pipe for split type AC indoor unit of any capacity and make as per OEMs specifications
S&F in repair PVC plug top 15 Amps, single phase, 240 Volts.of any make as per OEMs specifications
S&F in repair PVC plug top 5 Amps, single phase, 240 Volts.of any make as per OEMs specifications
Attending of complaints of summer appliances deploying experienced air condition / refrigeration mechanic and helper and rectification of complaints to th entire satisfaction of Engineer-In-Charge and users. Note:-(i) For rectification of complaints if any spares, gas etc required to be replaced the same shall be measured and paid seperately under "supply and fixing" items. (ii) Mechanic engaged by contractor for attending complaints and rectification there of, shall carry the required job card, which shall be supplied by contractor at his own cost. (iii) Sufficient mechanic and staff shall be engaged by contractor in order to rectify the all complaints with in 24 hrs on all working days as well as holidays as given by the Dept.If contractor fails to attend/rectify the complaints within 24 hrs he shall be penalised for Rs. 200 Per complaints.
Ganguly Construction
Neha Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .