Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹20.7 L
Closing Date
10 Sept 2020, 12:00 pmClosed
CCE R AND D EAST
NAPIER ROAD HASTINGS KOLKATA - 700022
PROVISION OF AGNI-5 TRAINING INFRASTRUCTURE AT MMO PANAGARH
2020_DRDO_574697_1
CCE (R and D) E/ENQ-18/CIV/2P/2020-21
Limited
Civil Works
780 days
Panagarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
CCE R AND D EAST
₹20.7 L
Yes
8 Oct 2020
7 Aug 2020
14 Sept 2020
7 Aug 2020
10 Sept 2020
24 Aug 2020
10 Aug 2020 - 12 Aug 2020
Amount
SUB HEAD-I - EARTH WORK
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge:
All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m.
All kinds of soil
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
SUB HEAD-II - CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns
Columns, piers, abutments, pillars, posts and struts
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.material in cement concrete per 50 kg
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
SUB HEAD-III - REINFORCED CEMENT CONCRETE
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls
Under 20 cm wide
Weather shade, Chajjas, corbels etc., including edges
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.
Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 380 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level upto floor V level
Extra for providing richer mixes at all floor levels Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.
Providing M-30 grade concrete instead of M-25 grade BMC/ RMC.(Note:- Cement content considered in M-30 is @ 400 kg/cum)
Add for using extra cement in the items of design mix over and above the specified cement content therein.
SUB HEAD-IV - BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry As per IS 2185part-3 with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars and drilling the column/Existing wall and fixing 200mm long, 50 x 4mm thk. MS Flat, bent to shape with anchor bolts . Approved GI mesh shall be placed and tied in position between masonry and MS Flat, bent to shape, with anchor bolts at every third course of half brick masonry.
SUB HEAD-V- STONE WORK
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand)
SUB HEAD-VI- CLADDING WORK
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
SUB HEAD-VII - WOOD AND PVC WORK
Extra for providing etched glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer's specifications and direction of Engineer-in-charge.
Decorative finish (both side wood grained finish)
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
With 12 mm mild steel U beading
SUB HEAD-VIII - STEEL WORK
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
4.0 mm thick glass panes
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of Required size, joints mitred and welded by angle iron flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
SUB HEAD-IX - FLOORING
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick
Providing and fixing glass strips in joints of terrazo/ cement concrete floors
40 mm wide and 4 mm thick
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
8mm thick
Granite of any colour and shade
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete
Size of Tile 600x600 mm
PVC Plain ESD Floor Mat, Thickness: 2mm
• Two layer ESD vinyl flooring • Dissipative flooring • Complies with DIN EN 61340-5-1 • Insulation resistance according to DIN VDE 0100-410 (personnel safety) • Abrasion resistant • Conductive backing • Suitable for chair castors, depending on floor substrate • Elastic • Reusable Technical Data: Property Standard Requirement Typical values Thickness EN428 2,0mm Weight EN430 3000g/m2 Size EN426 Roll: length 10m Width 1,5m Resistance to ground RE EN61340-4-1 EN61340-5-1 106-108Ω RE≤109Ω Wearer overall resistance EN61340-4-5 EN 61340-5-1 RE System ESD STM 97.1-1999 ≤35 MΩ(≤3,5X107Ω) 106-108Ω (Recommended for primary means of grounding) Walking test EN61340-4-5 Recommendation: Body voltage <100V Ideal case: Body voltage <100V(Body voltage measurement) ESD STM 97.2-1999 (depends on footwear)
Insulation resistance RI DIN VDE 0100-610 >5 x 104 Ω >5 x 104 Ω (UN = 500 volts)Effect of chair castors DIN68131/EN425 no effect, suitable if Type W according to DIN68131 Dimensional stability DIN1817/EN 434 ± 0,4% <0,2% Residual indentation DIN51955/EN 433 ≤0,1mm <0,1mm Colour fastness ISO 105 B02 Note 6 ≥7 Sound insulation ISO 140-8 Ca.2dB Fire resistance DIN4102 B2 B1 Abrasion resistance EN660 Pt2 Group T ≤2,0mm3 Seam strength EN 684 ≥400 N/50mm Thermal resistance 0,25W/m K
Preliminary Conditions: The sub-floor must comply with DIN18299 and DIN18365 standards. Maximum remaining humidity in the sub floor: For mineral Anhydrite (AE) and Anhydrive tiles (AFE): <0.5% For cement: <3.5% For concrete and cement composite: <5% For the best results install at room temperature between 18 and 20ºC. Sub-floor Preparation: • Sand blast or grind the sub floor to obtain rugged surface. • Apply a primary dispersion or an epoxy paint coating layer according to the expected load and allow adequate drying time. • Apply a good quality 2mm filling layer and allow a drying time of 4 to 8 hours. • Use an 80 grain size sand paper to obtain a smooth surface.
Floor Installation: 1. Do not use conductive glue. For optimum adhesion, use a good quality acrylic dispersion glue/ equivalent and follow the supplier’s instructions. 2. The supplied copper strips are used to electrically connect two adjacent floor areas. The wider strips should be positions close to walls and pillars. 3. Position the copper strips every 5 meters perpendicular to the seam underneath the length seam. 4. Position the wide copper strips close to a wall or to a pillar for further connect to an electrical ground by an electrician. A separate ground connection is needed for every 25-35 square meters. 5. Do not use the floor for 24 hours, after that time the floor is fully usable. 6. Seams between adjacent areas are obtained by cutting the overlapping edges. 7. For waterproof seams ask for a welding rod. We can only guarantee the quality of the products we supply. WE cannot guarantee that the recommendations given in this document have been followed during the installation.
Maintenance Instructions: Cleaning after installation: 1. Sweep the floor 2. Wet mop with mild alkaline solution (IE Floor stripper, KS40GAL) 3. For machine cleaning, use red pads or medium hard brushes. 4. Make sure that no water or dirt remains on the floor. Polishing after installation: Use ESD floor polish. Daily maintenance: Wet mop using a high quality floor cleaner having neutral or mild alkaline properties and follow the instructions. For high traffic areas use ESD floor polish where necessary. Stain removal: Remove all stains immediately to avoid permanent marks on the floor. Warning: Stain removers may damage the floor. When in doubt try the stain remover one small hidden area. Use the chemical rather than mechanical means to remove persistent stains.
SUB HEAD-X - ROOFING
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes
110 mm diameter
200 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
Coupler
110 mm bend
200 mm bend
Shoe (Plain)
110 mm Shoe
200 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
SUB HEAD-XI - FINISHING
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :
1:4 (1 cement: 4 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
Extra for providing and mixing water proofing material in cement .Per bag plaster work in proportion recommended by the manufacturers
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Rain coat paint made of Dr. Fixit or equivalent with following specifications: Surface Preparation: -All new cement-sand renderings/concrete surfaces should be allowed to age 6 to 8 weeks before surface coating. -Surface for treatment must be thoroughly cleaned of all laiance, loose material, oil grease, etc by mechanical means such as wire brushing & shot blasting. -Finally vacuum cleaning of all loose solids and liquids can be done, if required. Priming: Prime the surface with Dr. Fixit Primeseal or equivalent diluted with potable water by volume in 2:1 ration(2 parts primer and 1 part water) with a coverage of 10 Sqm per ltr and allow it to dry for 2 to 3 hours. Applying Base Coat: Applying one coat with brush or roller Dr. Fixit Raincoat Universal Base coat or equivalent with coverage of 8.0-9.0 Sqm per litre single coat.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Painting with aluminium paint of approved brand and manufacture to give an even shade .
Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
SUB HEAD-XII - DISMANTLING AND DEMOLISHING
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Cutting ballies or wooden posts of fencing at the point of projection above the concrete or ground and stacking the same within 50 metres lead.
SUB HEAD-XIII- ROAD WORK
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
"Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing 25mm dia dowel bars with sleeve @ 600mm c/c at joint, tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, tie bars to be paid separately).
Cement concrete prepared with batch mixing machine
Providing and laying in position bitumen hot sealing compound for expansion joints etc.
Using grade 'A' sealing compound.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as perdirection of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
75 mm thick back filling for pitching including supplying of required materials and consolidation etc. complete with :
Moorum
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of engineerin- charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 D grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
SUB HEAD-XIV - WATER SUPPLY & SANITARY INSTALLATIONS
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china wall mounting water closet of size 570x340x360 mm of approved shape including providing & fixing PVC concealed cistern of Size 460x450x80mm with dual flush plate fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc including painting of fittings and cutting and making good the walls and floors wherever required : complete.make Hindware cat Nos-92097
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Providing and fixing towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and . 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm. make JAQUAR ACN-1111N or eqv.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge.
Providing and fixing soil, waste and vent pipes :
100 mm dia
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
Providing and fixing soap Dish Holder with concealed fitting arrangements.Make Jaquar ACN-1131N or eqv.
Providing & fixing CP brass Health faucet with PVC Flexible Tube with wall hook.( JAQUAR MODEL NO-573 or Equilent.)
Providing and fixing beveled edge mirror of required size & shape, superior glass (of approved quality) complete with 6 mm thick marine grade ply wood ground fixed to wooden/PVC cleats with Stainless steel mirror stud, screws and washers complete as per direction of Engineer in Charge.
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing unplasticised Polyvinyl Chloride (UPVC) pipes, having thermal stability for hot & cold sewage supply including all UPVC plain fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, & testing of joints complete as per direction of Engineer in Charge.Toilet Sanitary pipe work
100 mm nominal inner dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Internal work - Exposed on wall
25 mm dia nominal bore
32 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
32 mm nominal bore.
40 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
25 mm diameter pipe
32 mm diameter pipe
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Circular tank
Providing and fixing C.P. brass long body Two Way bib cock of approved quality conforming to IS standards .
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
SUB HEAD-XV - DRAINAGE
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
150 mm diameter S.W. pipe
300 mm dia. R.C.C. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
150 x 100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes :
Size 90x80 cm
With common burnt clay F.P.S. (non modular) ricks of class designation 7.5
Size 120x90 cm
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Circular shape 560 mm internal diameter
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying and fixing C.I. cover without frame for manholes :
500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
SUB HEAD-XVI-ALUMINIUM WORK
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge.
Pre-laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
SUB HEAD-XVII - WATER PROOFING
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:
Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Surface preparation:-Cleaning of RCC roof by removal of dust ,dirt,laitance,following by ponding will be done on the applicotion surface. Any surface cracks needs to be into U groove and sealing it with polymerin 1:4 ratio (cement: sand)admixed with Dr Fixit pidicrete URP at 5% byweight of cemen . All corner joints will be cut open, followed by sealing the same with the same polymer mortor all in compllete. Cemen ,sand, aggregate,water will be supplied by contractor.providing and applying "Dr Fixit Flexi PU 270(i) high performance pure root , seamless, waterproof memberance,appliedin 2 coats of totol Systems thickness of 1.50 mm and having an elangation capacity of over 500% , tensil strength of 4 N/mm2 .and the coating will be terminated up to 300 mm on theparapet wall, all in complete. providing and laying 120-150 gsm geotextile on the cured memberane surface providing and laying protective screed concrete (M20 grade ) with admixture of recomanded propertion and average 50 mm thick(thickness can varydepending up on span of area ) . All in complete (including welded mesh 2mm dia and 100mmX100mm aparture but M-20 Grade sceed will be paid separately)
Providing aluminum flashing, wherever required for termination of Dr. Fixit Samshield XL 1500 membrane at all locations. Item shall include rates for membrane termination on the Vertical retaining wall at height as specified in drawings for termination of the membrane and finally sealing the strip using Dr. Fixit Pidiseal , Polysulphide sealant.Providing aluminum flashing, wherever required for termination of Dr. Fixit Samshield XL 1500 membrane at all locations. Item shall include rates for membrane termination on the Vertical retaining wall at height as specified in drawings for termination of the membrane and finally sealing the strip using Dr. Fixit Pidiseal , Polysulphide sealant.
Providing and applying Dr. Fixit Fastflex, a two component polymer based cementitious waterproofing system in following sequence;
Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means.
Removal of all surface imperfections, protrusions,loose concrete & filling of cracks using Dr Fixit Pidicrete URP Modified Mortar in the ratio Cement: Sand (1:4) and 5% by weight of cement.
Providing & grouting at construction joints cementitious grout into each nozzles( 1 mtr c/c) at regular intervals as per the requirements.
Providing and making fillets at the junction of the walls and the slabs using cement mortar of 1:4 mix admixed with 5 % of DR. FIXIT URP by weight of cement.
Applying 3 coats of Dr. Fixit Fastflex(2 component, prepacked,polymer modified cementitious coating)@ 3kg/sq.mtr all over the slab including the angular fillets and extendable over the vertical walls .Finally sprinkling sand over the third coat for better adhesion with plaster. The interval between each coat of Fastflex application is 6-8 hrs.
Providing & laying a protection layer of 25 mm thick cement mortar admixed with Dr. Fixit Pidiproof LW+
SUB HEAD-XVIII - EOT Crane
Supply ,installation, testing and commissing of 15/5 M/T Capacity 20 mtr span, Double Girder Box Type complete with15/5MT capacity Electric cab, Rotary limit switch. The crane will be with control panel having overload relays. The crane Wheel will be forged En -9 Steel, fitted with roller bearing and axle pin. The platform will be made of chequered plate, pipe railing and flexible cable for C.T motion. etc as complete as following specification & ANNEXURE- I (Technical Specification)
Double Girder Box Type. 25% overload ,height- 10 mtr,Span 20mtr heavy Duty class- III, head Room 2.5mtr,side clearence 300.indoor operation,Suitable Spped, 415V AC Supply, IS- 807/3177/4137, 110v AC Control Supply , Floor operated via pendant push button
MOTORS- Conforming to IS 325-1978& 900-1965,
GEAR BOX- Electro Hydraulic Thrusters type, 3Ph, 440V, A.C. Conforming with IS 3938 - 1983
WIRE ROPE- 6X 36 Cont. Hempcore(IS 2365-1963)
Rope Drum- made from Seamless/ms rolled
Hook- Forged Material EN-3A
WHEEL ASSEMBLY- Made from forged steel- Double flange hardened to BHN 275 Conforming with IS 807-1976.
BEARING- All bearings are of anti Friction Ball/ Roller Conforming, with IS 6455-1972
COUPLING- AlI Couplings will be Geared Coupling
SHAFT- All Shafts will be of EN - 9
RESISTANCE BOXES- AlI resistance boxes will be stainless steel, Wire grid and 15 min. Rated heavy duty, (IS 1822 -1967 )
LIMIT SWITCH- Rotary Limit Switch for Hoisting & Lever Type for L.T &C.T. Conforming with IS- 3936 - 1983
PANEL BOXES - All panel boxes will be of steel febricated
CONTROL TRANSFORMER- 750 VA, 44OV / LLOV.
POWER CONTROL CABLE -Sheet Metal housing, DustlVermin Proof having BCH/Siemens Contactors & Overload ReIays' BCH time delay Relay
PAINT- Two coats of Red Primer & Two coats of Golden Yellow.
Full platform on driving side & two small platform on non driving side.
SUB HEAD-XIX - Furniture
Providing and placing in position Anti Static Table Size 1500 mm x 750 mm x 1800 mm and Material used Mild Steel and Surface Finish Powder Coated and as per shope drawing Submitted by contractor and approved by Engineer-in-charge.
Providing and fixing Acrylic cover NOTICE BOARD of size 1200x1500mm, required felt colors, soft board backing with front cover with aluminiun framed acrylic sheet with loking arrangement etc. complete as approved by Engineer-in-charge
Providing and placing in position working bench of size 1600x750x900mm made of 18mm thick MDF BOARD and steel framed with granite top including storage cabnite/Drawer, Made as per SEFA 8 guidelines and as per shope drawing Submitted by contractor and approved by Engineer-in-charge.
Providing and placing in position Temperature Controlled Soldering Table Size 750 mm x 1800 mm x 750 mm and Material used Mild Steel and Surface Finish Powder Coated and as per shope drawing Submitted by contractor and approved by Engineer-in-charge.
Providng & placing in position Alkosign White writing Board of size 6 x8m double faced, magnetic,movable with 4 castors as Shown in Image & Brand As approved Engineer-in-charge. One side in white, can be used a writing board with ink markers. One side in green, can be used a writing board with chalks. Both side can be used as a magnetic board.
Supply of Display board of size 1200mm x 900mm made out of Alluminium frame having soft board of thickness 9mm with overall pinnability depth 15mm with felt material of 1mm thick of approved shade,GI sheet for rear panel including necessary hard ware fittings etc; complete all as per the directions of Engineer -in- charge.
Supplying and placing in position of Revolving Executive chair of size 760w x 760D x 850-950H mm. the seat & back made from 12mm thick hot pressed plywood and upholsterd with frabic and moulded polyurethane foam. The back foam is designed with contoured lumber support for extra comfort. the seat size: 470W x 480D mm and back size 470mm W x 580mm H . The HR polyurethane foam is moulded with density of 45+/-2kg per meter cube and hardness load of 16 +/-2kgf as per IS 7888 for 25% compression. The Armerest should be of one-piece armrest are fitted to the seat are injection moulded black copolymemer. there should be a synchrnous tilt mechanism designed with 360 degree revolving type and upright locking.there should be gas lift having height adjustment of stroke of 120mm. Below should have 3 piece telecopic type and injection moulded in black polypropylene. the ped should be injection in black 30% glass-filled nylone and with 5 twin wheel castore in injection moulded type of black nylon. the ped of 660mm +/- 5mm pitch-center dia. approved make: Godrej Modal BRAVO or eqv. as approved by Engineer-in-charge
Providng & placing in position Office Table of Size (1610Lx760Wx750H mm) Made of Table top 48 mm(16+16+16 Steps) thick Particle board with melamine finish.All Other Parts made of 18mm thick particle board with PU finish. And Six Drawer including all necessary hardware fittings & locking system complete. Make NILKAMAL Modal AVIATOR EXECUTIVE TABLE or Eqv.as approved by Engineer-in-charge
Providng & placing in position Visitor Chair of size 600w x 625D x 875 H mm. the seat & back made from 12mm thick hot pressed plywood and upholsterd with frabic and moulded polyurethane foam. The back foam is designed with contoured lumber support for extra comfort. the seat size: 470W x 480D mm and back size 470mm W x 580mm H . The HR polyurethane foam is moulded with density of 45+/-2kg per meter cube and hardness load of 16 +/-2kgf as per IS 7888 for 25% compression. The Armerest should be of one-piece armrest are fitted to the seat are injection moulded black copolymemer. there should be a synchrnous tilt mechanism designed. the ped should be injection in black 30% glass-filled nylone and with 5 twin wheel castore in injection moulded type of black nylon. the ped of 660mm +/- 5mm pitch-center dia. approved make: Godrej Modal BRAVO or eqv. as approved by Engineer-in-charge
Providing and placing in position Steel Almirah of outer size 1981.2 X 914.4 X 482.6 mm made of machine pressed steel sheet and powder coated in a shade as approved by Engineer-in-charge. Internal Size of Almirah: 1850 (H) X 900 (W) X 450 (D) mm. Leg Size of Almirah: 150 (H) X 120 (W) X 450 (D) mm. Rack with 5 Compartments of 4 no. of shelves. Distance between each shelf will be 360 mm. These shelves should be hanging arrangement (adjustable). Standard lock and 2 sets of keys. The thickness of the Almirah sheet shall be 18 SWG. The body of the Almirah shall be manufactured from cold rolled MS sheet (C. R. Sheet) with Antirust treatment and shall be finished with powder coating. The quality of used M.S sheet for making Almirah shall be free from any pitting and corrosion etc. H/D Rubber bushes shall be provided to the bottom of legs of Almirah. . Make Godrej, Delite, Steelcase, Methodax .
Providng & placing in position Book Shelf of size 1981h x 916w x 486d mm with three way bolting divice and prrecition made six lever lock . Cold rolled, closed annealed steel is treated with seven step anti-corrosion process for extra durability.provide storage with 4 adjustable shelves that can store anything. easy retrieval of items as visibility is ensured. 3mm thick glass paneled doors with steel framework. colour & shade Approved by Engineer-in-charge make Godrej modal Glass door Storwel product code:STSTW300XXX
Providing and placing in position writing chair with Folding Writing Board of size 540x540x790mm made of Stainlees steel frame. seat shall have: 50mm thik fome cushion on back rest and seat, duly upholstered with polypropylene or as par manufacture Spicifaction make NIlKAMAL modal No. CONTRACT01 with Arm black or EQV.
SUB HEAD-XX INTERNAL ELECTRIFICATION
LIGHT POINT WRING
Point wiring for Light / fan / Exhaust fan with 2 runs of 1100V grade 1.5 sq. mm & 1 run of 1.5 sq. mm FRLS insulated multistranded Copper wires, run in & including 25 mm dia , heavy class PVC conduit concealed in wall after necessary chase cutting with finishing/ surface on wall/ ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch and the box covered with front plate.
One Light point controlled by one 6A switch ).
Two Light point controlled by one 6A switch ).
Three Light point controlled by one 6A switch ).
Exhaust fan point controlled by one 6A switch including ceiling Rose.
6A SWITCH & SOCKET
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
CIRCUIT/ SUBMAIN WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
LIGHT FIXTURES
Supply, Installation, Testing & Commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, low loss, ortho cyclically wound open construction copper ballast, ignitor & power factor improvement capacitor or Electronics Ballast etc are prewired up to the terminal block & mounted on a removable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting. with Lamp Control Gear & Fixing Accessories.
80w DuraLED Highbay energy efficient lighting with a choice of narrow beam and wide beam optics. Philips BY325P LED100S CW PSE GR FG WB PB
Philips 20W LED-Batten-BN-108C-LED-20S-PSU-CDL-WH
Philips 10 W Endura LED Bulkhead, 6500 K WT202W LED6S CW PSU S2 PC
15W Philips LED surface Mounted Downlighter Sm200C LED 16S 6500 Psu Od Wh
8W MIRROR LIGHT Surface Mounted MAKE-PHILLIPS CAT NO. 34093/11
EXHAUST FANS
Supplying & Installation of exhaust fan in the existing opening, including gravity louver, making good the damage, connection, testing, commissioning etc. as required.
300mm Double ball bearings heavy duty motor exhaust fan, Protective bird guard is provided, Power: 70 watts. Guard : 36 Spokes. Noise level 40-45 dB
600mm 900 RPM Heavy Duty wall mounted Fan, Metal Body, 500W, 240V
POWER POINT WRING
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32A, 430 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 32 A "C" curve, 4 P, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A, 430 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63 A "C" curve, 4 P, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
SPLIT AC SYSTEM
Supply, installation, testing and commissioning of Hi wall Air Cooled split unit 3 STAR Rating as described in specifications. The unit shall be complete with cabinet type fan coil unit complete with hermatically inverted compressor ,evaprotive coil ,fans etc and external condensing unit complete in all respects, , , MS Stand, valves and inulation. It shall be inclusive of cooling thermostat with wiring, first fill of refrigerent, adjustable outdoor frame, control and earthing. The unit capacities shall be after taking deration into account due to copper piping lengths:
2.0 TR Hi wall type split air conditioning units
Supply, installation, testing and commissioning of AC SINGLE PHASE 5KVA Automatic operation having input voltage 170v to 270v and output voltage 240v. Complete with voltmeter, high and low voltage cut off & time Delay relay type digital voltmeter Stabilizer.as complete as required.
Supply , installation , testing and commissioning of refrigerent copper piping as per thr standered for 2.0 TR Hi wall type split air conditioning units including 3Cx2.5 sqmm power cable or as required , insulationed with closed cell nitrile /EPDM as per thr standered.The external refrigerent piping with cable will run on cable tray .including cutting,chasing etc complete in all respect.
2.0 TR Hi wall type split air conditioning units
Supply .Fixing and testing of PVC condensate drain piping with insulation of 6 mm thick nitrile rebber including wall cutting ,chasing of wall etc complete in all respect of fallowing pipe dia.
25mm dia.
CIRCUIT/ SUBMAIN WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 10 sq. mm earth wire
DISTRITUTION BOARD
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 A,36KA,FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
CABLE TRAYS
Supplying and fixing following size 2mm thick GI perforated cable tray with cover along with required angle, joined with connectors, suspended from the ceiling/wall with G.I. suspenders including G.I. bolts & nuts, etc. as required, tray should be fitted on the wall/ celling etc complete as required.
100 mm width X 50 mm depth X 2 mm thickness
300 mm width X 50 mm depth X 2 mm thickness
AIR CURTAIN
Supplying,installation, testing & fixing H1800 X D210 X W212mm, 21m/s, 3 double shaft, mild steel with Zn plating and powder coating surface Super slim air curtains in fitted with 3 motors & 6 blowers. etc complete as required.
SUB HEAD-XXI UPS SYSTEM
Supply, Installation, Testing and Commissioning of online Smart-UPS 10kVA , 400V 3PH With 30 min backup i/c battery (add 30min Extra Backup 10 KVA) , Output Power Capacity-8.0 KW / 10.0 kVA, Control panel-Phase indicating lamps RYB , IGBT based, Manual bypass switch ,double conversion, Audible and visible alarms prioritized by severity, Emergency Power Off, 3-phase in 3-phase out UPS with specified panel, batteries banks with racks, battery chargers, required cables, wires, circuit breakers etc as Complete, SCADA Compatible with remote monitoring & control in PRS mode complete in all respects.
UPS WIRING
Point wiring for Light / fan / Exhaust fan with 2 runs of 1100V grade 1.5 sq. mm & 1 run of 1.5 sq. mm FRLS insulated multistranded Copper wires, run in & including 25 mm dia , heavy class PVC conduit concealed in wall after necessary chase cutting with finishing/ surface on wall/ ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch and the box covered with front plate.
One Light point controlled by one 6A switch ).
Two Light point controlled by one 6A switch ).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
CIRCUIT/ SUBMAIN WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SUB HEAD -XXII TELEPHONE AND DATA SYSTEM
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.
1 or 2 Module (75mmX75mm)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Providing, fixing connecting and testing of under noted size of solderless telephone tag block Connector in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.
10 Pair Tag Block
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet (RJ11)
Supplying and fixing of modular type Lan (RJ-45) outlet in existing Box complete as required.
Computer socket outlet (RJ 45)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required
1 run of cable
Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
180 mm X 100 mm X 60 mm deep
SUB HEAD -XXIII FIRE ALARM SYSTEM
Supply, Erection, Testing and Commissioning of Single loop addressable fire alarm control panel with built in loop cards. FACP shall have capacity to look upto minimum of 198 devices per loop i.e.99 detectors & 99 modules, further shall be designed with 25% spare capacity towards future expansion FACP shall have 2 x 40 character LCD alphanumeric display with backlight, fully (100%) programmable disablement. Test, sounder fault, delayed mode, relays disabled, earth fault, system/CPU fault, sounder disabled. Alarm silenced, supply fault, power etc. It shall be provided with required capacity of maintainable free sealed acid batteries to provide 48 hours ( Including 30 mins in alarm condition) of indications with a maximum of 200 software zones.FACP Loop shall have built- in networking feature i.e. to form networking on LAN using TCP/IP converter Interface. It shall also have built -in feature of automatic telephone dialer(4 telephone/mobile nos.) with facility to pass pre- recorded message of up to 20 sec. System shall be designed as per the technical specification and shall comply to EN 54/IS 2189/UL Standards. etc as complete required.
Supply, installation, testing and commissioning of Microprocessor based manual call point complete as per specification required.
Supply, Installation, Testing & Commissioning of Microprocessor based Wall Mounted Voice Evacuation Hooter cum Speaker of 2W having power taps at 1/4-1/2 complete as per specification required.
Supply, installation, testing and commissioning of Microprocessor based addressable control module for activating the hooter etc. complete as per specification required.
Supplying, installation, testing and commissioning of Dual LED Response indicator for indicating the activation of the Remotely located Detector. Complete in all respect.
Supply, Installation, Testing & Commissioning of Smoke detector complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling complete as per specification required.
ADDRESSABLE BEAM DETECTOR
Supplying, laying, testing and commissioning of point wiring for sensors and devices like Input/Output modules, MCP's, smoke & heat detectors etc. with 2 x 1.5 sq.mm FRLS PVC insulated multi-stranded single core copper conductor wire in M.S. conduit with conduit accessories including loop circuit from main fire alarm panel located at ground floor in fire control room complete as required.
Supplying, laying, testing and commissioning of 2RX2CX1.5 sq.mm copper armoured cable for Fire alarm panel.
SUB HEAD -XXIV EARTHING SYSTEM
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub-main wiring/ cable as required.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
40 mm metal to be laid in the transformer yard for a height of 100mm
SUB HEAD- XXV External Electrical Work
H.T.VCB PANEL: ( Near Transformer in Weather Proof Enclosure Outdoor type)
Supply, installation, testing and commissioning of 1250A, 3P, 11 KV indoor type, drawout, Vacuum circuit breaker single Panel board fabricated out of minimum 2 mm thick CRCA sheet as per specification. The panel shall be complete with all accessories & cable termination boxes for incoming 3C x 185 Sqmm XLPE and outgoing 3C x 185 Sqmm XLPE, 11 KV cable. All current carrying parts should be of Copper.
The panel shall be comprising of 1 no, 11 KV, 1250 A,3P, drawout type vacuum circuit breaker with spring charged stored energy mechanism having spring charging motor 240VAC, Closing coil suitable for 24V DC, Tripping coil suitable for 24V DC, Aux. Contacts 6NO+6NC, Antipumping device, Mechanical Close & Trip Lever, Manual spring charging device, mechanical operation counter, mechanical ON/OFF, Mechanical spring charged indication
One (1) no. multi function meter with RS 485 port with minimum parameters Voltage, Ampere, KWH, KVAh, KW, KVA, KVAR, PF & HZ. with 1 Set (3 Nos) of 50/5A ratio,CL 1.0 C.T,s & control fuses.
1 Set of phase indication lamps with HRC fuses (Red, Yellow and Blue).
1 Set of indication lights with HRC fuses for CB open, CB close, Auto trip, Spring charged, battery low`.
Auxillary switch/ relay, under voltage, master trip, Anti-pumping relay and other control relays etc. as per requirement -Lot. 1 Set of IDMTL O/C and E/F relay similar to CDG-61 of M/s ALSTOM or equivalent complete with 3 nos. (1 set). Current transformer 50/5A, CL-5P 10 for protection, 15 VA burden.
1 Set of potential transformer 11KV/1.732, 110/1.732 volts 100 VA burden.
1 set of 6 window, Audio / visual annunciation system complete with Transformer trouble & protection trip annunciation.
Supply, installation, testing and commssioning of above specified 11KV HT Panel as described above Board as per manufacturers instruction, as per specification and complete as required.
TRANSFORMER : Supply, installation, testing and commissioning of 11 KV/ 433V, 3 phase, 50 Hz delta/star-11 connected, out door type, 750 KVA transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent, Off Load tap changer with + 5 % to – 7.5 % tappings in the steps of 2.5%, bi-directional roller, diagrams & rating plate, Oil gauge, Oil temperature indicator, & Winding temperature indicator, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.T. cable box & disconnecting chamber/ LT cable box & disconnecting chamber, (All instrument/relay/CT terminals / contacts wiring to be done upto marshalling Box). etc. complete as per specification
All relays, contacts & CT terminals to be wired upto marshalling box.
Enclosure shall be of split up type so that top portion of the enclosure can be removed without disturbing core-coil assembly for shifting purpose.
750 KVA Transformer
Transformer described as above.
DG SET
Supply at site, installation, testing & commissioning of 3-phase, 415 volt, 50 HZ, Silent type Diesel generator set of 750 KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure with canopy, inbuilt Suitable Standard tank capacity ,with AMF Panel,battery, battery charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator, pcc based auto start & synchronization set, safeties with accessories as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to IS:4722.
Supply and fixing in position the approved "shock treatment charts" framed in teak wood frame and covered with glass in front as required in two languages (Hindi & English)
Supply and fixing in position the best quality "Danger Boards" of approved shape and size as specified by Local Electricity Authorities written in English and Local languages.
11000V (250mm X 200mm)
440V (150mm X 100mm)
Supply & Laying of non skid Electro mat 1 mtr wide and 3.0 mm thick 11KV grade conforming to IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.
Supply of fire buckets 5 nos. 15 litre capacity duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. The fire buckets shall be painted red from outside and white from inside, including lettered as FIRE with white colour with extra handle at bottom.
Supply & Laying of non skid Electro mat 1mtr wide and 2.0 mm thick 1.1KV grade IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.
Supply of Rubber hand gloves 11KV grade, as per IS 4770-1968.
Supply of standard first aid box as approved by Indian red cross society/ St.John Ambulance Brigade and conforming to IS 2217-1963.
HT CABLE
Supplying, testing,commissioning of following sizes XLPE, 11 KV earthed cable in existing open structure/ Hume pipe including in vertical formation as per technical specification and complete as required. (The payments of cable length shall only be made upto gland in panel on both sides not for loop and connection cables of approximate length upto 2 metres either sides.)
3Cx240 Sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Above 120 sq. mm and upto 400 sq. mm
Supplying and making outdoor cable end termination with cast resin compound, including lugs and other jointing materials complete with all accessories for following sizes of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
3Cx185 Sq.mm.
MAIN LT PANEL
LT cum Sychronization Panel
Transformer Incomer : ACB 1250A FP 50KA MP RELEASE O/L,S/C, E/F PROTECTION
DG Incoming : ACB 1250A FP 50KA MP RELEASE O/L,S/C, E/F PROTECTION
Metering For Incomers :
LED Phase indication lamps with individuals MCBs and control with toggle switches
Interlocking : Electrical mechanical interlocking between 2 No. Incomers
Busbars : 1600A TPN Aluminium Busbar - 1 Set
Suitable Metering For O/G
Outgoings :
MCCB 630A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 02NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK
MCCB 400A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 01NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK
MCCB 125A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 01NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK
MCCB 40A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 03NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK
16A, TPN MCB - 1NOS
300KVAR APFC PANEL
Busbars : 800A TPN Aluminium Busbar - 1 Set
Outgoings :
Suitable Metering For O/G
50KVAR CAPACITOR : 4NOS, MCCB 125A TP 25KA TM RELEASE, ROTRY HANDLE FOR MCCB, 50KAVR CAPACITOR DUTY CONTACTOR, 50KAVR HEAVY DUTY CAPACITOR,440V, START/STOP PUSH BUTTON, LAMP
25KVAR CAPACITOR : 2NOS, MCCB 63A TP 25KA TM RELEASE, ROTRY HANDLE FOR MCCB, 25KAVR CAPACITOR DUTY CONTACTOR, 25KAVR HEAVY DUTY CAPACITOR,440V,START/STOP PUSH BUTTON, LAMP
20KVAR CAPACITOR : 1NOS, MCCB 50A TP 25KA TM RELEASE,ROTRY HANDLE FOR MCCB, 20KAVR CAPACITOR DUTY CONTACTOR, 20KAVR HEAVY DUTY CAPACITOR,440V,START/STOP PUSH BUTTON, LAMP
10KVAR CAPACITOR : 2NOS MCCB 32A TP 25KA TM RELEASE,ROTRY HANDLE FOR MCCB, 10KAVR CAPACITOR DUTY CONTACTOR, 10KAVR HEAVY DUTY CAPACITOR,440V, START/STOP PUSH BUTTON,LAMP
5KVAR CAPACITOR : 2NOS MCCB 16A TP 25KA TM RELEASE,ROTRY HANDLE FOR MCCB, 5KAVR CAPACITOR DUTY CONTACTOR, 5KAVR HEAVY DUTY CAPACITOR,440V, START/STOP PUSH BUTTON,LAMP
Enclosure of capacitor panel shall be liberally designed to take care of internal heat emission by capacitor unit without forced cooling and to limit the temperature rise with in permissible limit. However, louvers are allowed to facilitate extra cooling.
35 kA fault level continous Al Earth Bus shall be part of Panel for full length of panel
FEEDER PANEL
Incomer : MCCB 400A FP 36KA TM RELEASE O/L,S/C PROTECTION
Metering For Incomers :
LED Phase indication lamps with individuals MCBs and control with toggle switches
Busbars : 400A TPN Aluminium Busbar - 1 Set
Outgoings :
MCCB 630A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- MCCB 63A TP+NL 36KA TM RELEASE WITH O/L,-09 NOS S/C PROTECTION
SUPPLY AND INSTALATION, CABLES
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.
3.5 x 300 sq.mm
3.5 x 185sq.mm
3.5 x 50 sq.mm
4 x 25 sq.mm
4 x 16 sq.mm
4 x 10 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 x 300 sq.mm
3.5 x 185 sq.mm
3.5 x 50 sq.mm
4 x 25 sq.mm
4 x 16 sq.mm
4 x 10 sq.mm
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
150mm dia
250mm dia
BUS TRUNKING
Supplying, installing on wall, Floor or suspension on ceiling, testing and commissioning of following capacity Air Insulated Compact Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints, fire barrier at each floor, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.
1250 A Isc = 50kA for 1 second
FEEDER PANEL
Supply ,installation, testing and commissing of Cubical Out door type Feeder Panel, (IP-65) suitable for 415 Volt, 3 Phase, 4 wire , 50 Hz , A.C supply system, fabricated in compartmentalized ( Preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates including cleaning and finishing as complete bottom base channel of MS section not less than 40mmX40mmX6mm thick, fabrication shall be done in transportable sections, entire panel shall have a common aluminium earth bar with suitable size at the rear with 2 nos earth stud. Distribution box with LED Indicaters & Protection Features ( in all respects)need to care for the following sockets-
INCOMING:
MCCB 400A FP 36KA TM RELEASE O/L,S/C PROTECTION-01
400 Amps Aluminium Bus Bar
OUTGOING
63 Amps 3 pole TPN , 36KA, 415V ,50HZ -9Nos, MCCB ROTARY HANDEL
AREA LIGHTING
Supplying of sewaged type welded steel tubular pole 7.5M height and suitable curved single arms of 1.5m x48.4mm x 3.2m(Length x OD x Thickness) with overall length of section -Bottom section- 4.5m x114.4mm x 5.4mm, Middle section- 1.5m x 88.9mm x 4.85mm, Top section- 1.5m x 76.1 x 3.25mm with IS 2713-80 , latest amedment 410-SP-6 complete M.S.BASE PLATE :- 300 X 300 X 6MM NOTE ;-PCC shall be measured and paid for separately.
Supply and fixing of 70W LED energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection and impact resistance of IK07, ENDURACITYLINERNEOSL70WLED757PASYBOTG
Erection and shiftting as required of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Above 8.0 meter and upto 10.0 meter
Providing and making MS steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20 mm) of specified size and shape including form work, plastering if required, curing etc. as required. (volume of pole/ pipe not to be deducted)
(SHEET MOULDED COMPOUND) junction box size 200mm x 140mm x95mm as per IS: 13410 & IS:14722 completed with door, hinger and locking arrangement ,including one no. 6 amps MCB SP, AL busbar (TPN) , stainless steel terminal, MCB channel , with clamp for fixing with pole.
Providing spiral coil earthing with 8 SWG G.I wire including spreading os salt and charcoal as per IS: 3043-87 with lastest ammendments.
Providing and fixing 8 SWG dia G.I. Wire on surfaces or in recess for loop earthing along with existing surfaces /recessed conduit/submain wiring/cable as requried
Wiring for street Light fitting from junction box to street light fitting with ( 2x 2.5 sqmm copper conductor, 11kv grade, PVC insulaed, unsheathed single core cable in surface/ recessed as required.
SUB HEAD : XXVI FIRE FIGHTING SYSTEM
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
Horizontal end section top discharge centrifugal close coupled pump set CI casing Bronze impeller SS shaft pump set with all accessories complete as required and directed by Engineer In-charge
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.
450lpm 35m head ( 1Working + 1 Stand By)
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal /Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
100mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
100mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
100mm dia
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
30 Meter
Providing and fixing ISI Marked of approved make Fire Extinguishers complete with all accessories as per manufacturer's specifications.
CO2 gas nozzle type - 4.5 Litre capacity (IS:15683).
Providing and fixing signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+ -10%) containing lumigen II as base chemical, covered under UV stablized coating and of appropriate size (Glo-lite or eq. Make) including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats anchor fasteners etc. complete in all respacts as diercted by Engineer-in-charge
SUB HEAD : XXVII , AC
Scroll Air cooled Chilling Machine
Supply, installation, testing and commissioning of Air cooled Scroll Chilling machine of 50 TR actual capacity at below mentioned operating conditions with R - 134 A / R- 410 A refrigerant, semihermatic sealed invertor compressor, driven by suitable KW Sq. Cage induction motor complete with copper condenser, insulated Dx chiller, flow switches at chiller outlet, refrigerant piping, Refrigerant and Oil (First Charge), Microprocessor based control panel, motor starter & accessories etc. all mounted on M.S. frame. Motor shall be suitable for 415 volts ± 10%, 50Hz ± 5 %, three phase A.C. supply. The chilling m/c as described above shall be in line with specifications.
Chiller shall be following models -
Chiller CHW IN - 54º F
CHW OUT - 44º F.
FLOW - 120 USGPM
Fouling Factor - 0.0001 0F, Ft2, Hr/BTU
Ambient at 43 deg C
PUMPS SETS
Supply , Installing, testing and commissioning of end suction top discharge flanged connections coupled through flexible coupling complete with suitable electric motor for circulation of chilled/Hot water for central air-conditioning system. All pumps shall be aligned. The pump motor shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply. The price shall also include the cost of thermal insulation and vibration isolation pads as per specification.
Pumps shall be following models -
Chilled Water Pumps
Chilled Water Flow Rate : 120 US GPM
Head : 18 MT
Hot Water Pump Set
Water flow rate = 140 USGPM
Head = 15 Mt
HORIZONTAL AIR HANDLING UNITS WITH PLUG FAN & VFD
Supply, installation, testing & commissioning of double skin air handling units with Plug Fan, 50 mm thick PUF insulation consisting of IE3 motor, vibration isolators, cooling coil section with 6 row deep coils , heating coil with 4 row deep coil, Pre and fine filter section with G4 & G7 filters, double canvas connections, with volume control dampers fresh air and outlet of AHU etc complete as per specifications and drawings.
AHU shall be inbuilt with DDC control panel along with necessary sensor and controls so as to maintain desired temp and RH inside the lab area.
VFD designed for HVAC applications for supply air fan with built-in PID controller, control panel (keypad & display) , IP-55/54 enclosure for use on standard centrifugal fans. The VFDs should not cause any deration of the connected motors and must ensure that class B temperature levels of the connected motors are never exceeded. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have builtin harmonic filters.
AHU shall be following models -
Tag Floor Area CFM Total Static TR
AHU-1,2 & 3 G.F. Lab 16000 60MMWG 45
HORIZONTAL FAN COIL UNITS
Suuply, Installation, testing & commissioning of horizontal fan coil units with fan, motor, 3 rows coil. Supply & installation of copper pipe connections and fittings, flexible drain connections, power & control cabling from unit to junction box and thermostate (Indocom),3 speed fan on/off control cooling/heating temperature control and Vibration isolators, Fan coil units shall be suitable for 230 ± 10% 50 Hz single phase power supply.
Tag Floor Area CFM TR
FCU -1, 2, 3 & 4 GF&F.F. Store/class 1200 3.0
CLOSED EXPANSION TANK
Supplying, installing and testing of expansion tank, fabricated out of 4 mm thick GI plate construction, The tank shall be complete with necessary connection for piping and vent. i.e 25 mm dia make up connection with float valve, drain valve, and incoming line valves, vent connections, valves and fittings as required. Insulation shall be 13 mm thick cross linked polyethylene with aluminum protection film. The insulation shall be with self adhesive. .
Centrifugal Type Air Seperator
Supply, installation, testing & Commissioning of Centrifugal Type Air Seperator of approved make complete with fittings & valves & insulation as required for chilled water fittings & suitable for flow specified
100 mm dia
Ultrsonic Humidifier
Supply, installation, testing & Commissioning of Ultrasonic humidifier with all necessary controls and accessories.
capacity 200 kg
HOT WATER GENERATOR
Supply, installing, testing and commissioning of Vertical , Top openable type Hot water generator of following capacity conforming to BIS standards at specified flow rate and hot water temperature complete as per specification with following accessories.
Matching electrical immersion heater bank. Heater shall be seamless copper sheeted sheath electrically resistant U tube type suitable for 3 phase 415 Volts with flange ends.
All automatic and safety control such as safety valve, purge filling valves for descaling filled at inlet & outlet. High limit cut-out, automatic and manual reset, low level cut out step controller and recycling relay, thermostats pilot light (for individual heating circuit and alarm, poor interlock switches, flow switch and other control.
Electrical panel mounted on generator frame complete with internal wiring, contactor, switches etc.
Interconnecting cables between panel and heater.
Hot Water in Temp. : 45oC
Hot Water out Temp : 50oC
Heating Capacity : 200 KW
25KW in 6 bank
Water Flow rate : 150 USGPM
PIPING:
CHILLED WATER PIPING
Supply, laying, fixing, testing & commissioning of MS class ‘C’ class pipes complete with all necessary fittings such as bends, tees, reducers, flanges etc and supports such as clamps, anti-vibration hangers etc duly insulated ( whereever required) with Expanded Polystyrene of 50 mm thick pipe section of density 16 kg/m3 & covered with sand cement plaster complete as per specifications and drawings.
125 mm dia (50 mm insulation )
100 mm dia (50 mm insulation )
80 mm dia (50 mm insulation )
50 mm dia (50 mm insulation )
32 mm dia (25 mm insulation )
25 mm dia (25 mm insulation )
SITC of GI "B" Class piping complete with necessary fittings & insulated with Expanded Polystyrene pipe section of 25 mm thickness , density 16 kg/ cum & covered with sand cement plaster as per specifications
40 mm dia
VALVES
Supplying, fixing, testing and commissioning in position the following valves, strainer etc. in chilled water pipe line complete with flanges etc duly insulated as per specifications & drawings.
Butterfly Valves - PN16 rating
125 mm dia
100 mm dia
80 mm dia
Balancing valves - PN16 rating
100 mm dia
80 mm dia
25 mm dia
Dual Plate Non-Return Valve - PN16 rating
100 mm dia
80 mm dia
3-Way Modulating Control Valve - PN16 rating
Supply, Installation, testing & commissioning of 3-Way Modulating Valve (Insulated) with thermostat of following sizes, as per specifications & drawings.:-
80 mm dia
20 mm dia
Suction Guide with Strainer - PN16 rating
100 mm dia
80 mm dia
FLEXIBLE CONNECTION - PN16 rating
100 mm dia
80 mm dia
`Y' strainers - PN16 rating
80 mm dia
Pot strainers - PN16 rating
100 mm dia
Flow Switch
Auto Air Vent
10 mm dia
Pressure Gauges & Thermometers
Providing and fixing in position 100 mm dial type pressure gauges & V form thermometers complete as per specifications.
Pressure Gauges
Thermometers
Ball Valve - PN16 rating
25 mm dia
Ball Valve with Y-Strainer for FCU
25 mm dia
AIR DISTRIBUTION:
SHEET METAL DUCT:
SITC of site fabricated / machine made sheet metal ducts ( 120 GSM) of following thickness including necessary supports, hangers, nut & bolts, gaskets, splitter dampers, vanes, etc complete as per specifications in accordance with the approved shop drawings and as required.
26 gauge galvanised sheet
24 gauge galvanised sheet
22 gauge galvanised sheet
20 gauge galvanised sheet
18 gauge galvanised sheet
FIRE DAMPERS (motorized with spring return):
Supply, installation, testing and commissioning of fire damper of at least 90 minutes fire rating as per specification & approved shop drawings, complete with electronic temperature sensor and electrically operated actuator with return spring, and provision to shut off AHU/Fan blowers when the damper closes.Fire damper shall be located in the supply\ return air ducts, the control panel will be such located that reset can be done easily as per specificaions.
Fire damper
Accessories such as actuator with smoke sensor and remote indicators of fire damper position.
SUPPLY/RETURN AIR DIFFUSER:
Supply, installation, testing and balancing of square supply/ return air diffusers. Each diffuser shall be equipped with fixed air distribution and anti-smudge ring where required as per the shop drawings.
Extruded Aluminium powder coated S/A diffusers with damper
Extruded Aluminium powder coated R/A diffusers without damper
VOLUME CONTROL DAMPER:
Supply, installation and testing of GI volume control dampers within ducts complete with suit-able links, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system.
Air Grilles
Supply, Installation, Testing and Balancing of Powder coated extruded aluminium construction Grilles with removable core as per approved drawings and specifications. Quoted price shall be inclusive of volume control damper behind supply air collar.
Supply, installation, testing and balancing of powder coated extruded aluminium. Air Grilles without volume control dampers.
Jet Nozzle & Diffusers
Supply, Installation, Testing and Balancing of Powder coated aluminium construction Jet nozzle and diffuser with low noise, suitable for 8-10 m throw with required plenums and accessories.
Air louvers
Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminium construction inlet air louvers with bird screen for fresh air as per specifications and approved shop drawings.
INSULATION:
THERMAL INSULATION:
SITC of external thermal insulation on ducts with nitrile rubber as per the specifications & approved shop drawings..
12mm thick insulation (Supply Ducts)
9 mm thick insulation (Return Ducts)
ACOUSTIC LINING (DUCTS):
Supply, installation & testing of acoustic lining within ducts as per specifications. All ducts shall be provided with 32 Kg/m3 fibre glass acoustic lining as per the specifications.
25 mm Acoustic lining for duct .
ELECTRICAL PANEL FOR HVAC WORKS :
POWER AND MOTOR CONTROL CENTRES:
Design, manufacture, supply, installation, testing and commissioning of cubicle type 2 mm thick sheet steel MV switchgear panels by CPRI apprved firms suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting/wall mounted, sheet metal clad, cubicle. (Detail as per attached Electrical SLD)
Panel shall be enclosed in separate compartment for each feeder, front operated, rear connections indoor type LT motor control panel, dust and vermin proof, drawout/hinged and lockable doors, complete with internal wiring, colour coding with ferrules, cable glands, bonding to earth and painting.
All MCCBs shall be provided with magnetic & adjustable thermal releases for short circuit & overload protection with front drive kit (rotary operating handle).
The above panel shall be suitable for the capacities of the equipments specified above viz Chillers , Chilled water Pumps, Hot water pumps , Hot water Generator, & Air Handling Units. Motor control centre shall include all cabling & earthing over MS Powder coated cable trays into various equipment/motor and all associated control wiring.
a) Digging holes in ordinary soil and refilling the same with the excavatedearth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)
i) Holes 1.2 m dia and 1.2 m deep
ii) Holes 0.90 m dia and 0.90m deep
i)Supply and stacking of Bauhinia blakeana (Kachnar) plant of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
ii) Supply and stacking of Cassia siamea plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
c) Providing and displaying of Areca Palm plant having ht. 1.80 m to 2.10 m with 8 to 10 suckers,well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
d) Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material's as per direction of officer in charge (excluding cast of plant & water).
i) Trees Plant
e) Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% Concentration and as per direction of officer-in-charge
f) Complete maintenance of trees (Out side garden features), jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of the material which shall be supplied by the department) and as per direction of officer-in-charge.
Trees for 250 no/(up to 4 & up to 3 year Slow &Fast growing Per tree group)
SHRUB PLANTATION (SOLO)
a) Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost ofmanure, sludge or extra good earth if needed to be paid for separately)
i) Holes 60cm dia and 60cm deep
b) Supply and stacking of the following well developed,healthy,true to variety/type plants having minimum height as below mentioned at site work
i) Supply and stacking of plant Hibiscus rosasinensis of height 60-75 cm.with 5-6 branches in p.bag of size 25 cm as per direction of the officer-in-charge.
ii) Supply and stacking of plant Mussaenda erythrophylla (Rosea) of height 60-75 cm. Multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge.
iii) Supply and stacking of plant Tabernaemontana coronaria (Chadni single) variegated of height 60-75 cm, 5-6 branches in p.bags of size 25 cm as per direction of the officer-in-charge.
c) Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable i/c material's as per direction of officer in charge (excluding cast of plant & water).
i) Shrubs Plant
d) Antitermite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from temite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.
e)Complete maintenance of shrub(out side of lawn area), jobs like making of basin at regular interval i/c watering,weeding.prunning & application of fertilizer etc. (excluding the cost of material which shall be supplied by the department) and as per direction of officer- in- charge.
HEDGE PLANTATION
a) Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm. refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 5:1 (5 parts of stacked volume of earth after reduction by 20% * one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing. leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or declared extra earth to be paid for separately)
i) Supply and stacking of plant Thevetia nerifolia of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in- charge.
ii) Supply and stacking of plant Ficus panda of height 30-45 cm. with 3-4 branches and healthy foliage in p.bag of size 20 cm as per direction of the officer-in-charge.
c) Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material's as per direction of officer in charge (exctuding cast of plant & water).
Hedge Plant
d) Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/ledge bed watering, manureing and applying insecticides and fungicides etc.(excluding the cost of material which shall be supplied by the department) and as per direction of oficer in charge.
e) Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @1.00 litre solution per sqm lawn or bed area.(two application) i/c Cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge
Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
M.P.KHAITAN
Surendra Infrastructure Pvt. Ltd.
LIRA CONSTRUCTIONS PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid