Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹60.8 LAccepted-AOC | ₹60.8 L | 1 | Accepted-AOC ACCEPTED |
| 2 | 2₹84.2 LRejected-AOC C6040 OLD NO 63 NEW NO 23 CHOLAMBEDU MAIN ROAD KRISHNAPURAM AMBATTUR CHENNAI 53 | CHENNAI | AMBATTUR | TAMIL NADU | 600053 | ₹84.2 L | 2 | Rejected-AOC REJECTED |
| Sl No | Description | Qty | Unit | KUMARAN INDUSTRIES L1 | V.K.CONTRACTORS L2 |
|---|---|---|---|---|---|
| 1.00 | Supply and Installation of Single Phase 6 KVA Streetlight controller with RF based Gateway controller Device capability of scheduling the on/off timings of lighting control switchgears based on preset timings or based on the available annual sun-rise and annual sun-set timings wih GPRS/GSM based remote streetlight monitoring system with capacity for self-protection from short-circuit, over voltage and anti-theft alert including the System capability to capture and provide following parameters at variable time-intervals
a. live data collection of:
i. Voltages
ii. Current
iii. Power Factor
iv. Active Power (kW)
v. Metering kWh cumulative
vi. Number of hours the lamps were glowing
b. Special emergency on/off facility with wireless control.
c. Benchmarking capacity so as to generate alert message for:
i. Phase-wise currents on crossing threshold values
ii. Phase-wise voltages on crossing threshold values
iii. MCB trips
iv. Theft alerts | 156 | 1Nos(One Number) | 38,996 ₹60.8 L | 54,000 ₹84.2 L |
| 1.01v. Switching component failure vi. No output supply d. Alert message shall be forwarded to five (5) phone numbers. e. Alert for Door open. f. Enclosure Box to be IP55 compliant and in case of Metal enclosure has to be corrosion-resistant. g. GPRS/GSM modem used should be a Dual-band modem with power consumption less than 3 watts. h. Energy Meter with ISI marking is to be used for power measurement. Class 1.0 accuracy or better energy meter to be used. i. The rating of the Streetlight controller should be at least two times the lighting load. j. The Streetlight Controller should have inbuilt RF Gateway device to be used in conjunction with Individual Lamp Monitoring (ILM) devices for future proof. k. Design life should be more than 10 years l. ON/OFF automatic Timer with Contactor for peak and off peak hour operations | |||||
Tender Value
₹73 L
EMD Value
₹73,000
Closing Date
19 Feb 2026, 3:00 pmClosed
COMMISSIONER
113 Thamilzh Salai(Palai Road) Thoothukudi Corporation
Replacing of balance 156 Nos Flood damaged and High Voltage 440 damaged CCMS box at various location in Thoothukudi city municipal corporation
2026_MAWS_653767_1
52/25-26/CE(Electrical)
Open Tender
Electrical Works
90 days
THOOTHUKUDI CORPORATION
Refer Technical Bid
2 documents required · 2 mandatory
₹0
₹73,000
THOOTHUKUDI CORPORATION
26 Mar 2026
10 Feb 2026
19 Feb 2026
10 Feb 2026
19 Feb 2026
17 Feb 2026
16 Feb 2026
Supply and Installation of Single Phase 6 KVA Streetlight controller with RF based Gateway controller Device capability of scheduling the on/off timings of lighting control switchgears based on preset timings or based on the available annual sun-rise and annual sun-set timings wih GPRS/GSM based remote streetlight monitoring system with capacity for self-protection from short-circuit, over voltage and anti-theft alert including the System capability to capture and provide following parameters at variable time-intervals a. live data collection of: i. Voltages ii. Current iii. Power Factor iv. Active Power (kW) v. Metering kWh cumulative vi. Number of hours the lamps were glowing b. Special emergency on/off facility with wireless control. c. Benchmarking capacity so as to generate alert message for: i. Phase-wise currents on crossing threshold values ii. Phase-wise voltages on crossing threshold values iii. MCB trips iv. Theft alerts
v. Switching component failure vi. No output supply d. Alert message shall be forwarded to five (5) phone numbers. e. Alert for Door open. f. Enclosure Box to be IP55 compliant and in case of Metal enclosure has to be corrosion-resistant. g. GPRS/GSM modem used should be a Dual-band modem with power consumption less than 3 watts. h. Energy Meter with ISI marking is to be used for power measurement. Class 1.0 accuracy or better energy meter to be used. i. The rating of the Streetlight controller should be at least two times the lighting load. j. The Streetlight Controller should have inbuilt RF Gateway device to be used in conjunction with Individual Lamp Monitoring (ILM) devices for future proof. k. Design life should be more than 10 years l. ON/OFF automatic Timer with Contactor for peak and off peak hour operations
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
CCMSBID.pdf
Tender Documents • 0.93 MB
BOQ_783959.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid