| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.7 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹13.7 Cr Quoted ₹13.8 Cr | 1 | Accepted-AOC Being lowest bidder and overall tender is found reasonable. |
| 2 | 2₹14.4 CrRejected-Finance PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | ₹14.4 Cr | 2 | Rejected-Finance Being other than lowest bidder. |
| 3 | 3₹16.5 CrRejected-Finance | ₹16.5 Cr | 3 | Rejected-Finance Being other than lowest bidder. |
| 4 | 4₹16.6 CrRejected-Finance | ₹16.6 Cr | 4 | Rejected-Finance Being other than lowest bidder. |
Tender Value
₹14.8 Cr
EMD Value
₹10.7 Cr
Closing Date
30 Sept 2019, 6:00 pmClosed
Sr DDG and CE
DGNP Mumbai, Naval Dockyard, SBS Road, Mumbai - 400023
AUGMENTATION OF SERVICES AT BARRACK WHARF AND DESTROYER WHARF AT NAVAL DOCKYARD MUMBAI
2019_MES_270173_1
DGNP_MB_8493_1
Open Tender
Civil Works
900 days
Mumbai
MES ENLISTED CLASS S CATEGORY OF WORKS (a)(i), (b)(i), (b)(ii) OR UNENLISTED COTRACTORS MEETING ENLISTMENT CRITERIA OF CLASS S OF MES
7 documents required · 7 mandatory
₹3,000
Yes
DGNP Mumbai
₹10.7 Cr
Yes
DGNP Mumbai
9 Jan 2020
26 Jul 2019
7 Oct 2019
26 Jul 2019
30 Sept 2019
16 Aug 2019
5 Aug 2019
Amount
SCHEDULE 'A' PART-I (BUILDING)
Construction of MILLWRIGHT GOWDOWN, ELECTRICAL GODOWN, TRANSFORMER BAY building with all fittings and fixtures complete all as specified and shown on drawings. NOTE:- (i) Excavated materials shall be removed from the site simultaneously & continuously while doing excavation work as space is not available for storing the excavated earth at site. Excavated materials shall be removed and deposited out side MD land at the tenderers cost. Unit rate quoted shall be deemed to be included for this work also.
Total amount of Sch 'A' Part I C/o to General Summary on Ser Page No. 202(R)
SCHEDULE 'A' PART-II-B (PILE FOUNDATION)
Material and labour for boring for cast in situ pile 300 mm nominal dia through soft/loose soil, stiff clay, soft disintegrated rock or any other strata (except hard rock strata) by any suitable method duly supported by drilling fluid or by casing including removal of excavated earth outside MD land with all its lift and leads complete all as specified and as directed.
Material and labour for boring for cast in situ pile 300 mm dia through hard rock by any suitable method including removal of excavated rock outside MD land with all its lift and leads complete all as specified and as directed.
Material and labour for Initial load testing (Compression) up to maximum test load of 2.5 times the safe load capacity on single pile as specified in accordance with IS : 2911 Part 4 including preparation of pile head for testing, necessary excavation, jacks, kentledge, accessories, measuring devices, recording of results, labour, submission of test report etc. complete, but excluding the cost of installation of pile (installation of pile shall be measured and paid separately) etc. including bringing on site all equipment required and removal from the site after testing is completed etc. complete all as specified and as directed.
Material and labour for routine load testing (Compression) up to maximum test load of 1.5 times the safe load capacity as specified in accordance with IS : 2911 Part 4 including preparation of pile head for testing, necessary excavation, jacks, kentledge, accessories, measuring devices, recording of results, labour, submission of test report etc. complete, but excluding the cost of installation of pile (installation of pile shall be measured and paid separately) etc. including bringing on site all equipment required and removal from the site after testing is completed etc. complete all as specified and as directed.
Material and labour for non destructive integrity testing on 300 mm dia pile including all arrangement for test, equipments/accessories, materials, labour, submission of test report but excluding the cost of installation of pile (installation of pile shall be measured and paid separately) etc. including bringing on site all equipment required and removal from the site after testing is completed etc. complete all as specified and as directed.
Total amount of Sch 'A' Part II-B C/o to General Summary on Ser Page No. 202(R)
SCHEDULE 'A' PART-III-B (INTERNAL ELECTRIFICATION)
Supply and fixing PVC blanking plate for MCB DB complete all as specified and as directed.
Material and labour for surface sub main wiring with 2 single core 4.0 Sqmm nominal area with 1100 Volt grade ISI marked with IS : 694, PVC insulated unsheathed cable with 1 run of 4.0 Sqmm multi stranded copper conductor cable (FRLSH) ISI marked for continuous earth wire drawn in and including surface heavy duty steel conduit of suitable size (not less than 20 mm dia) medium grade with fitting (ISI marked) including cutting, chasing for conduit and making good of walls etc. complete all as specified and as directed. NOTES :- (a) Two runs of cable, one run of steel conduit and one run of cable as earth wire shall be measured as one length. (b) Cable required for connection to DBs shall be deemed to be included and shall not be measured separately. (c) Cable for earth wire shall run inside the conduit.
Supply and fixing sheet metal MCB DB SPN, 6 way, 240 V, double door type powder coated with 200 Amps copper bus br, neutral link, earth rail and din rail ISI marked complete all as specified and as directed. NOTES :- (i) MCBs, Isolator, RCOBs/RCCBs, ELCBs shall be measured and paid for separately under respective items. (ii) MCBs, Isolator, RCOBs/RCCBs, ELCBs shall be of same make.
Supply and fixing MCB, SPN, "C" curve, 240 volts, 6-32 Amps, 10 KA, ISI marked complete all as specified and as directed.
Supply and fixing MCB, SP, "C" curve, 240 volts, 6-32 Amps, 10 KA, ISI marked complete all as specified and as directed.
Supply and fixing LED street/security light fitting 90 W housing made of pressure die-cast aluminium alloy with toughened glass IP-65/66 protection, working on 240 volts, 50 Hz, consisting of reflective lens, wired with appropriate driver PF > 0.98 having over voltage protection upto 400 volts, surge protection level 7-10 KV, thermal short protection THD < 10%, made up of long life LED chips (SMD) in modular with Ra > 70 and LED lumen efficiency>120 lumen per watt, beam angle along the drive way, 135 degree through (beam angle across thw drive way0 75 degree including fixing on pole with 02 Nos MS clamp made out of 40 x 6 mm FI and bracket made out of 40 mm dia GI pipe not less than 1.2 metre long bent to shape including connecting with 1.50 Sq mm, 3 core, PVC insulated copper conductor cable 1100 volts grade all as specified and as directed. NOTE :- The contractor shall give warranty for street light fitting including driver for minimum period for 3 years for any defects developed during the period.
Supply and fixing surface mounted LED luminaire, 20 Watt, with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98, having over voltage protection upto 400 Volts, surge protection level 7-10 KV, thermal short circuit protection THD <10%, made up of long life LED chips (SMD) in modular with Ra >70 and LED lumen efficiency >120 lumen per watt, internally pre-wired including PVC insulated three core copper flexible conductor cable 1.5 sq mm drawn through flexible pipe connecting with ceiling rose all as specified and as directed. Note :- The contractor shall submit warranty for LED lunimaire including driver from the manufacturer for minimum of 3 years for any defects developed during the period.
Supply and fixing wall fan/air circulator 450 mm sweep, single phase, 230 volts AC, 50 Hz, oscillating type, 1350 RPM lSI marked including PVC insulated three core flexible copper conductor 1.5 Sq mm drawn through flexible connecting pipe with ceiling rose all as specified and as directed.
Total amount of Sch 'A' Part III-B C/o to General Summary on Ser Page No. 202(R)
SCHEDULE 'A' PART-IV-B (EXTERNAL WATER SUPPLY)
Construction of brick masonry valve/hydrant pit of internal size 90 cm x 90 cm x 90 cm depth with mild steel sheet cover of 3 mm thick and MS angle iron frame 50 mm x 50 mm x 6 mm duly painted with two coat of synthetic enamel paint over a coat of red oxide primer, including excavation and earth work,150 mm thick PCC 1:4:8 type D-2 as in foundation, brick work in cement mortar 1:4, locking arrangement and alI inner side of pit plastered with 15 mm thick in cement mortar(1:4) and coping in 1:2:4 type B1 over brick wall complete all as specified and as directed.
Material and labour for anti corrosive and anti marine growth painting with two coats over a coat of primer on surface of CI pipe of 150/100/80 mm size including necessary preparation all as specified and as directed.
Total amount of Sch 'A' Part IV-B C/o to General Summary on Ser Page No. 202(R)
SCHEDULE 'A' PART-V-B (FIRE FIGHTING)
Dismantling of hydrant of any type and any size and keeping at site for disposal complete all as specified and as directed.
Supply and fixing cast iron air release valve with two air outlets, 200 mm bore ISI marked and fixing up in cast iron/DI water mains, including necessary fixing materials such as nuts, bolts, washers, gaskets etc. complete all as specified and as directed.
Construction of brick masonry valve/hydrant pit of internal size 90 cm x 90 cm x 90 cm depth with mild steel sheet cover of 3 mm thick and MS angle iron frame 50 mm x 50 mm x 6 mm duly painted with two coat of synthetic enamel paint over a coat of red oxide primer, including excavation and earth work, 150 mm thick PCC 1:4:8 type D2 as in foundation, brick work in cement mortar 1:4, locking arrangement and all inner side of pit plastered with 15 mm thick In cement mortar (1:4) and coping in PCC 1:2:4 type B1 over brick wall complete all as specified and as directed.
Taking up/down existing both ends flanged cast iron water mains 200 mm bore including all fittings and accessories such as sluice valves, NRV, air release valve, pressure gauge etc. & turning off water and draining the system as required and stacking for reuse or for disposal complete all as specified and as directed.
Taking up/down existing both ends flanged cast iron water mains 150 mm bore including all fittings and accessories such as sluice valves, NRV, air release valve, pressure gauge etc. & turning off water and draining the system as required and stacking for reuse or for disposal complete all as specified and as directed. Note for Serial Item Nos 5.04 & 5.05 :- Cost for providing offshore support for working under jetty shall be deemed to be included in the rates of these items.
Supply and fixing MS pipe ISI marked with IS : 3589 (heavy class) thickness not less than 6.00 mm including cutting, threading, welding etc. and providing all fittings required for joints such as welding screw joints, anchors, tees, elbows, reducers, hinges, flanges, gasket, nuts, bolts, washers etc. of any shape and all as per relevant IS including painting of pipes and fittings with approved anti corrosive and anti marine paint over a coat of ready mixed primer, both of approved quality etc. laid in trenches/duct etc. of size 200 mm bore complete all as specified and as directed. Note :- Cost for providing offshore support for working under jetty shall be deemed to be included in the rates of this item.
Supply and laying MS pipe ISI marked with IS : 1239 (heavy class) thickness not less than 5.4 mm including cutting, threading, welding etc. and providing all fittings required for joints such as welding screw joints, anchors, tees, elbows, reducers, hinges, flanges, gasket, nuts, bolts, washers etc. of any shape and all as per relevant IS including painting of pipes and fittings with approved anti corrosive and anti marine paint over a coat of ready mixed primer, both of approved quality etc. laid in trenches/duct etc. of size 100 mm bore complete all as specified and as directed. Note :- Cost for providing offshore support for working under jetty shall be deemed to be included in the rates of this item.
Total amount of Sch 'A' Part V-B C/o to General Summary on Ser Page No. 203(R)
SCHEDULE 'A' PART-VI-B (L P AIR SUPPLY)
Material and labour for providing flanged joint complete with 25 mm thick Galvanized Iron, lSI marked flanges -02 Nos with 2.0 mm thick rubber gasket, including necessary nuts, bolts, washers etc. as required suitable for 200 mm dia heavy class GI pipe all as specified and as directed.
Material and labour for providing flanged joint complete with 19 mm thick Galvanized Iron, lSI marked flanges -02 Nos with 2.0 mm thick rubber gasket, including necessary nuts, bolts, washers etc. as required suitable for 100 mm dia heavy class GI pipe all as specified and as directed.
Material and labour for providing air tapping point complete with 100 x 50 x 50 mm dia flanged Tee -01 No, 50 x 25 x 25 mm dia flanged Tee -02 Nos, 25 mm dia gate valves-04 Nos including rubber gasket complete with necessary nuts, bolts, washers etc. as required all as specified and as directed.
Taking up/down existing GI pipe line 150 mm dia with all fittings and accessories such as sluice valve, pressure gauge, GI fittings, joists, channels, angles etc. and keeping at site complete all as specified and as directed.
Taking up/down existing GI pipe line 100 mm dia with all fittings and accessories such as sluice valve, GI fittings, joists, channels, angles etc. and keeping at site complete all as specified and as directed.
Taking up/down air tapping point with all accessories such as tee, valve etc. of any type and size all as specified and as directed.
Supply and laying MS pipe ISI marked with IS : 1239 (heavy class) thickness not less than 5.4 mm including cutting, threading, welding etc. and providing all fittings required for joints such as welding screw joints, anchors, tees, elbows, reducers, hinges, flanges, gasket, nuts, bolts, washers etc. of any shape and all as per relevant IS including painting of pipes and fittings with approved anti corrosive and anti marine paint over a coat of ready mixed primer, both of approved quality etc. laid in trenches/duct etc. of size 150 mm bore complete all as specified and as directed.
Supply and laying MS pipe ISI marked with IS : 1239 (heavy class) thickness not less than 5.4 mm including cutting, threading, welding etc. and providing all fittings required for joints such as welding screw joints, anchors, tees, elbows, reducers, hinges, flanges, gasket, nuts, bolts, washers etc. of any shape and all as per relevant IS including painting of pipes and fittings with approved anti corrosive and anti marine paint over a coat of ready mixed primer, both of approved quality etc. laid in trenches/duct etc. of size 100 mm bore complete all as specified and as directed.
Supply and laying MS pipe ISI marked with IS : 1239 (heavy class) thickness not less than 5.4 mm including cutting, threading, welding etc. and providing all fittings required for joints such as welding screw joints, anchors, tees, elbows, reducers, hinges, flanges, gasket, nuts, bolts, washers etc. of any shape and all as per relevant IS including painting of pipes and fittings with approved anti corrosive and anti marine paint over a coat of ready mixed primer, both of approved quality etc. laid in trenches/duct etc. of size 25 mm bore complete all as specified and as directed.
Total amount of Sch 'A' Part VI-B C/o to General Summary on Ser Page No. 203(R)
SCHEDULE 'A' PART-VII-B (EXTERNAL ELECTRIFICATION)
Design, supply, handling, assembling, installation, testing and commissioning in correct assigned position, effecting proper connections, of distribution transformer step down, outdoor type SCADA compatible of capacity 1.60 MVA, dual ration, 11 KV-6.6 KV/.440 KV, 3 phase, 50 Hz AC, ester oil filled type with with on load tap changing arrangements with remote control panel operation (RTCC) on 11/6.6 KV sides to vary secondary voltage from (=) 5% to (-) 15% in steps of 1.25% (16 steps), impedence suitable marshalling box and primary side terminals 3 Nos outdoor bare bushing with arching horn and secondary side terminal extended copper bus bar with cable box on secondary side additional neutral with one No solid porcelain type outdoor bushings with sockets on the transformer lid for earthing purpose complete in all respects with standard accessories and fittings confirming to TS : 1180, primary side delta and secondary side star connected neutral grounded losses of the transformer as per IS : 1180 Level-2 complete all as specified and as directed and having following salient features :-
(A) Transformer shall be Dyn -11 vector group ester oil immersed naturally cooled, double wound copper winding core type, Radiator cooled MS tank with first of ester oil as per relevant IS with ONAN cooling system. The temperature of oil shall not rise 50 deg C to ambient temperature of winding shall not rise 60 deg C. Transformer shall be painting with two coats of synthetic enamel paint with two coats of epoxy paint as per IS : 632. (B) Standard Fittings : (i) Rating and diagram along with levels where ever necessary, non detachable (ii) Earthing terminals with lugs -2 Nos. (iii) Lifting lugs for main tank & top cover (iv) Thermometer pocket with cap along with thermometer. (v) Air release hole with plug. (vi) Oil conservator tank with oil filling hole, drain plugs Prismatic oil level including maximum oil level marking. (vii) Dehydrating breather charged with silica gel - 01 No (viii) LV bushings – 04 Nos (ix) Sampling valves, top and bottom. (x) HV Bushing - 03 Nos (xi) Arching Horn on HT side - 03 Nos. (xii) Additional neutral separately brought out side, LV cable end box with bush insulator for neutral earthing.
(xiii) First oil fill. (xiv) Drain cum bottom filter valve with plug. (xv) Top filter valve with plug. (xvi) Explosive vent with diaphragm and equalizer pipe (Pressure release valve) (xvii) Jacking lugs and hauling holes (xviii) Inspection covers. (xix) Detachable radiators with shut off valves between radiators and tank. (xx) Radiator with air release hole and plug. Oil drain hole with plug and lifting eye all as per manufacturer's standards. (xxi) Base channel 100x50 mm, 460 mm long with hole to make them suitable for fixing on Platform or plinth. (xxii) 150mm dia oil temperature indicator stems type. (xxiii) Double float Bucholtz relay with two sets of contacts and isolating valves. (xxiv) 150 mm dia winding temperature indicator with maximum indicating pointer and resetting device. (xxv) 100mm dia magnetic oil level gauge with low level alarm. (xxvi) Terminal connection on the HV bushing (xxvii) Unidirectional reversible roller -04 Nos (width distance shall be as per Broad Gauge rails). (xxviii) Marshaling box.
(x) Inter locking between manual and electric operation with and including following :- (a) Handle for manual operation (b) Auxiliary transformer (xi) Main isolating switch with set of fuses. (xii) Insulated terminal board (with connector) for transformer tap leads. (xiii) Mechanical tap position indicator with handle. (xiv) Tap changing operation counter, (xv) Rating plate. (xvi) Driving mechanism chamber locking arrangement (xvii) Un -drilled gland plate for cable entry. (xviii) Terminal strips (xix) Drain cum filter valves. (xx) Stoppers to prevent over travelling of mechanism. (xxi) Indoor floor mounted remote control cubicals (RTCC Panel , AVR relay) with rear accessories with wiring and following :- (a) Remote tap position indicating meter digital type. (b) Tap change in progress signal lamps with belt (c) Raise / lower push buttons for remote operation (d) Inside illuminating lamp with door switch. (e) Supply on signals
(v) Foundation and civil works as per manufacture's recommendation shall be provided at 'NO' extra cost to the department. (vi) Earthing shall be measured and paid separately. (vii) The stud for neutrals shall be sufficient long to fix 2 Nos strip earthing. (viii) Routine test as IS : 1180 shall be conducted and test certificate shall be furnished. (ix) The quoted price shall be deemed to be inclusive of connecting of trip contacts of bucholtz delay and temperature indicator of windings of oil to the trip coil in panel board. (x) Cost of initial oil filling with ester Oil die electric strength not less than 70KV at 2.5mm gap shall be deemed to be included in the item rate. (xi) All material and labour required for provision of differential protection of transformer including wiring and testing at site shall be provided by the contractor without any extra cost.
(xii) RTCC and AV shall be suitable for automatic voltage regulation with master follower scheme with tap position indicator as per tap indication in the OLTC mechanism, RTCC shall also be provided with control gear in respect of fan ON/OFF indication, auto and manual control switch AC supply on and tap changer in progress indication lamp tap struck indication and alarm. (xiii) The erection of the transformer shall be done under the Supervision of manufacturer’s authorized representative. Certificate in this regard shall be submitted by the contractor duly signed by authorized representative of manufacturer and Engineer-in-charge/GE.
Material and labour for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz, AC supply system, fully compartmentalized, both side openable, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works/anchoring bolts for fixing, PCC foundation etc. with and including following :- BUS BAR CHAMBER : Electrically grade copper shrouded busbar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, fixed on DMC insulators and provision of extension.
BUSCOUPLER : Microprocessor based ACB, 1600 Amps, 4 pole, drawout type, breaking capacity Icu =Ics =Icw (1 sec), 50 KA, EDO,50 Hz, over load, short circuit & instantaneous protection with adjustable current & time delay settings, inbuilt earth fault protection complete with all accessories -01 No OUTGOING : (a) Microprocessor based ACB, 1000 Amps, 4 pole, drawout type, breaking capacity Icu = Ics = Icw (1 sec), 50 KA, EDO, 50 Hz, over load, short circuit & instantaneous protection with adjustable current & time delay settings, in built earth fault protection complete with all accessories -06 Nos (b) Microprocessor based ACB, 630 Amps, 4 pole, drawout type, breaking capacity Icu =Ics =Icw (1 sec), 50 KA, EDO,50 Hz, over load, short circuit & instantaneous protection with adjustable current & time delay settings, inbuilt earth fault protection complete with all accessories -01 No
Material and labour for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz, AC supply system, fully compartmentalized, both side openable, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works/anchoring bolts for fixing, PCC foundation etc. with and including following :- BUS BAR CHAMBER : Electrically grade copper shrouded busbar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, fixed on DMC insulators and provision of extension for connecting with existing LT Panel.
BUS COUPLER : Microprocessor based ACB, 2500 Amps, 4 pole, drawout type, breaking capacity Icu =Ics =Icw (1 sec), 50 KA, EDO,50 Hz, over load, short circuit & instantaneous protection with adjustable current & time delay settings, inbuilt earth fault protection complete with all accessories -02 Nos OUTGOING : (a) Microprocessor based ACB, 1000 Amps, 4 pole, drawout type, breaking capacity Icu = Ics = Icw (1 sec), 50 KA, EDO, 50 Hz, over load, short circuit & instantaneous protection with adjustable current & time delay settings, in built earth fault protection complete with all accessories -04 Nos (b) Microprocessor based ACB, 1000 Amps, 4 pole, drawout type, breaking capacity Icu =Ics =Icw (1 sec), 50 KA, EDO, 50 Hz, over load, short circuit & instantaneous protection with adjustable current & time delay settings, inbuilt earth fault protection complete with all accessories -03 Nos
(c) Microprocessor based ACB, 630 Amps, 4 pole, drawout type, breaking capacity Icu =Ics =Icw (1 sec), 50 KA, EDO, 50 Hz over load, short circuit & instantaneous protection with adjustable current & time delay settings, inbuilt earth fault protection complete with all accessories -02 Nos (d) MCCB 630 Amps, 4 pole, 50 KA, 50Hz with adjustable thermal & magnetic type Ics = 100% Icu -01 No (e) MCCB 400 Amps, 4 pole, 50 KA, 50Hz with with adjustable thermal & magnetic type Ics = 100% Icu -08 Nos (f) MCCB 200 Amps, 4 pole, 50 KA, 50 Hz with with adjustable thermal & magnetic type Ics = 100% Icu - 03 Nos
Material and labour for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete all as specified and as directed and with and including following :- BUSBAR CHAMBER : Copper bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, Extension of busbar should be provided if the No of cables feeding the bus bar are more than single run.
NOTES FOR SERIAL ITEM NOS 7.02, 7.03 & 7.04 :- (i) Panel manufacturer shall have in house powder coating plant with minimum 8 tanks pretreatment of MS sheet facilities, dust free spray paint booth. (8 tanks pretreatment process includes : degreasing / water rinsing /de-rusting / water rinsing/ activation / phosphating / water rinsing /passivation). (ii) Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel. (iii) Pre dispatch inspection shall be carried out by the authorized representative of Accepting Officer. In case of any deviation from approved drawing, the same shall be rejected and fresh LT panle shall be got fabricated from the manufacturer. Testing shall be done at manufacturer’s premises and all routine tests like IR and continuity tests shall be performed/recorded in presence of authorized representative of Accepting Officer.
(iv) The panel manufacturer shall have following certification : (a) CPRI certification Degree of protection of IP-54 (shall have IEC:61439-1 -2 & IEC:60529 tests) (b) CPRI certification short circuit with stand strength shall be 50 KA RMS for 1 sec with initial peak of 105 KA. (c) CPRI certification rated current for short circuit not less than 6000A (v) MCCB (microprocessor based) / ACBs provided shall be capable for online setting of the current. (vi) ACBs provided shall be capable for online setting to the time delay. (vii) All the electrical switch gear like MCCBs, MCBs and ACBs shall be of same make. (viii) All incomer ACBs and MCCBs (microprocessor based) shall be compatible with SCADA through communication port. (ix) Drawing of panel board shall be got from GE before fabrication. (x) Panel board shall be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
Material and labour for design, supply, installation, testing and commissioning of cope box having provision for incoming cable connection from single source, of size 75 cm x 75 cm x 50 cm (L x H x D), made out of 3.00 mm thick CRCA sheet steel for load bearing and 2.00mm for non load bearing, totally enclosed, dust and vermin proof, protection of enclosure IP-54 as per IS 2147 with pretreatment including powder coating, and mounted on angle iron frame at a height of 45cm from top of PCC platform complete. with 04 Nos Copper busbar, the length of copper busbar shall not be less than 60cm and having 1000 Amps capacity insulated with heat shrinkable sleeves with colour code mounted on suitable "F" class insulators made out of non hygroscopic, high strength FRP/SMC / DMC material at suitable interval and having termination for connection of ship cables, phase indication lamps (RYB) and required civil works for fixing, anchoring bolts, PCC foundation etc. all as specified and as directed.
Material and labour for design, supply, installation, testing and commissioning of cope box having provision for incoming cable connection from single source, of size 75 cm x 75 cm x 50 cm (L x H x D), made out of 3.00 mm thick CRCA sheet steel for load bearing and 2.00mm for non load bearing, totally enclosed, dust and vermin proof, protection of enclosure IP-54 as per IS 2147 with pretreatment including powder coating, and mounted on angle iron frame at a height of 45cm from top of PCC platform complete, with 04 Nos Copper busbar, the length of copper busbar shall not be less than 60cm and having 1000 Amps capacity insulated with heat shrinkable sleeves with colour code mounted on suitable "F" class insulators made out of non hygroscopic, high strength FRP/SMC / DMC material at suitable interval and having termination for connection of ship cables, phase indication lamps (RYB) and required civil works for fixing, anchoring bolts, PCC foundation etc. all as specified and as directed with and including following :- (a) MCCB 125 Amps, 4 pole, 50 HZ, 36 KA with adjustable thermal & magnetic release Ics = 100% Icu - 04 Nos (b) Industrial panel mounted receptacle 125 Amps, 5 pole, 415 volts, 50 Hz with torsion spring contact having inclination of 15° including suitable plug, highly heat resistant, contact carrier, frame terminals, Nickel plated contacts, cable gland and sealing, strain relief and protection against kinking, confirming IP-67 protection -04 Nos
Material and labour for design, supply, installation, testing and commissioning of cope box having provision for incoming cable connection from two sources in two compartments, of size 150 cm x 75 cm x 50 cm (L x H x D), fabricated in two compartments made out of 3.00 mm thick CRCA sheet steel for load bearing and 2.00mm for non load bearing, totally enclosed, dust and vermin proof, protection of enclosure IP-54 as per IS 2147 with pretreatment including powder coating, and mounted on angle iron frame at a height of 45cm from top of PCC platform complete, with 04 Nos copper busbar, the length of copper busbar shall not be less than 60cm and having 1000 Amps capacity in each compartment insulated with heat shrinkable sleeves with colour code mounted on suitable "F" class insulators made out of non hygroscopic, high strength FRP/SMC / DMC material at suitable interval and having termination for connection of ship cables, phase indication lamps (RYB) and required civil works for fixing, anchoring bolts, PCC foundation etc. all as specified and as directed.
NOTES FOR SERIAL ITEM NOS 7.05, 7.06 & 7.07 :- (i) Cope box manufacturer shall have in house powder coating plant with minimum 8 tanks pretreatment of MS sheet facilities, dust free spray paint booth. (8 tanks pretreatment process includes : degreasing / water rinsing /de-rusting / water rinsing/ activation / phosphating / water rinsing /passivation). (ii) Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with Cope Box Panel. (iii) The cope box manufacturer shall have following certification : (a) CPRI certification Degree of protection of IP-54 (shall have IEC:61439-1 -2 & IEC:60529 tests) (b) CPRI certification short circuit with stand strength shall be 50 KA RMS for 1 sec with initial peak of 105 KA. (c) CPRI certification rated current for short circuit not less than 6000A (iv) Drawing of cope box board shall be got approved from GE before fabrication.
Material and labor for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, intenal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete all as specified and as directed and with and including following :- BUSBAR CHAMBER : Copper bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, Extension of busbar should be provided if the No of cables feeding the bus bar are more than single run.
Material and labour for design, supply, fabrication, installation, testing and commissioning factory made, Feeder Pillar Box, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, intenal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete with extended limb 400 Amp rating all as specified and as directed and with and including following :-
Material and labor for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete all as specified and as directed and with and including following :- BUSBAR CHAMBER : Copper bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, Extension of busbar should be provided if the No of cables feeding the bus bar are more than single run.
Material and labor for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete all as specified and as directed and with and including following :- BUSBAR CHAMBER : Copper bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, Extension of busbar should be provided if the No of cables feeding the bus bar are more than single run.
Material and labor for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete all as specified and as directed and with and including following :- BUSBAR CHAMBER : Copper bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, Extension of busbar should be provided if the No of cables feeding the bus bar are more than single run.
Material and labor for design, supply, fabrication, installation, testing and commissioning factory made, Feeder Pillar Box, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete with extended limb of 200 Amp rating all as specified and as directed and with and including following :-
Material and labor for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete all as specified and as directed and with and including following :- BUSBAR CHAMBER : Copper bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, Extension of busbar should be provided if the No of cables feeding the bus bar are more than single run.
Material and labor for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete all as specified and as directed and with and including following :- BUSBAR CHAMBER : Copper bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, Extension of busbar should be provided if the No of cables feeding the bus bar are more than single run.
Material and labour for design, supply, fabrication, installation, testing and commissioning factory made, Feeder Pillar Box, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete with extended limb of 200 Amp rating all as specified and as directed and with and including following :-
Material and labour for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete all as specified and as directed and with and including following :- BUSBAR CHAMBER : Copper bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, Extension of busbar should be provided if the No of cables feeding the bus bar are more than single run.
Material and labor for design, supply, fabrication, installation, testing and commissioning factory made, LT panel board, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete all as specified and as directed and with and including following :- BUSBAR CHAMBER : Copper bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switchgears, extension of bus bar shall be provided if the No of cables feeding the bus bar are more than single run.
Material and labor for design, supply, fabrication, installation, testing and commissioning factory made, Feeder Pillar Box, outdoor type, double door totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, suitable for 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00mm thick CRCA sheet steel for load bearing and 2.00mm thick for non load bearing, protection of enclosure IP-54 as per IS : 2147 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works for fixing, anchoring bolts, excavation and earth work, PCC foundation etc. complete with extended limb of 600 Amp rating all as specified and as directed and with and including following :- INCOMER/OUTGOING : (a) MCCB 4P 630 Amps, 415 volts, 60 Hz, 36 KA (Ics =100% Icu) of Quantity - 01 No (Adjustable Thermal & Magnetic type).
(iii) Pre dispatch inspection shall be carried out by the authorized representative of Accepting Officer. In case of any deviation from approved drawing, the same shall be rejected and fresh LT panel/Feeder Pillar Box shall be got fabricated from the manufacturer. Testing shall be done at manufacturer’s premises and all routine tests like IR and continuity tests shall be performed/recorded in presence of authorized representative of Accepting Officer. (iv) The Panel Board/Feeder Pillar Box manufacturer shall have following certification : (a) CPRI certification Degree of protection of IP-54 (shall have IEC:61439-1 -2 & IEC:60529 tests) (b) CPRI certification short circuit with stand strength shall be 50 KA RMS for 1 sec with initial peak of 105 KA. (c) CPRI certification rated current for short circuit not less than 6000A (v) MCCB (microprocessor based) / ACBs provided shall be capable for online setting of the current. (vi) ACBs provided shall be capable for online setting to the time delay.
(vii) All the electrical switch gear like MCCBs, MCBs and ACBs shall be of same make. (viii) All incomer ACBs and MCCBs (microprocessor based) shall be compatible with SCADA through communication port. (ix) Drawing of Panel Board/Feeder Pillar Box shall be got from GE before fabrication. (x) Panel board/Feeder Pillar Box shall be compartmentalized in accordance to form 4 b of IEC 61439-1-2.
Material and labour for relaying of old LT cable of size 300 to 400 Sq mm complete on wall/floor, platform, duct etc. including provision of saddle, clamp for securing of LT cable retrieved from item No 7.20 all as specified and as directed. Notes :- (i) Termination with brass compression glands and aluminium lugs shall be provided as required at site. (ii) The contractor shall be responsible for any damage occured during taking out or relaying and contractor shall be responsible for repair/replacement of the same without any extra cost to the Government.
Supply and erection of GI Octagonal street light Pole, made out of 3 mm thick, single arm, 9 meter long in single section, hot dip galvanized as per IS : 2629/IS : 2633 / IS : 759 standards with single dip HD galvanized, average coating thickness of 70 micron, bolted with 20 mm diameter, 240 x 240 mm PCD, 04 foundation bolts, 20 mm thick base plate,150 mm bottom diameter and 75 mm top diameter including PCC foundation as per manufacturer instruction complete all as specified and as directed.
Supply and fixing LED street/security light fitting, pressure die-cast aluminium housing, IP-65 roadway luminaire, 90 W, 240 volts, 50 Hz, consisting of reflective lens, wired with appropriate driver PF>0.98 having over voltage protection upto 400 volts, surge protection level 7-10 KV, thermal short protection THD <10%, long life LED chips (SMD) in modular with Ra>70 and LED lumen efficiency >120 lumen per watt, beam angle along the drive way, 135 degree through (beam angle across the drive way) 75 degree including fixed on pole with 02 Nos MS clamp made out of 40 x 6 mm FI and bracket made out of 40 mm dia light grade GI pipe not less than 1.2 meter long bend to shape including connecting with 1.5 sq mm, 3 core, PVC insulated copper conductor, 1100 Volts grade all as specified and as directed. Note:- The firm shall give warranty for street light fitting including driver minimum for 3 years for any defects developed during the period.
Supply and fixing street light pole terminal box, out door type (IP-65) made of thermoplastic polystyrene of internal dimension not less than 260 mm x 210 mm x 110 mm size, weather proof, water proof, door with locking arrangement and provision for 2 Nos cable entry at bottom, MCB SP 6 Amps -01 No, Aluminium busbar -04 Nos, 200 Amps, 240 volts AC, mounted on porcelain insulators including fixing to pole with FI 20 x 3 mm size with nut, bolts and washers complete all as specified and as directed.
Supply and laying PVC insulated, FR PVC round sheathed, 2.5 sq mm, 3 core, 1100 Volts grade, flexible, stranded copper conductor, connected with terminating lugs conforming to IS 694 suitable for street light in and including steel conduit not less than 20 mm bore with necessary clamping arrangement all as specified and as directed.
Taking down existing street light fitting of any type and size from pole complete and handing over to user all as specified and as directed.
Dismantling/removing existing HT OCB switch gear 05 Nos from foundation including all accessories and stacking at a place inside Dockyard for handing over to user all as specified and as directed.
Dismantling/removing existing transformer of 750 KVA capacity after removing all cables/earthing connections and shifting to a place inside dockyard for handing over to user all as specified and as directed.
Dismantling/removing existing panel consisting of following switchgears of any size and capacity after removing all cables/earthing connections including and shifting into a place inside dockyard for handing over to user all as specified and as directed :- (i) LT OCB panel consisting of 10 Nos OCB switchgear (location : Annex SS) (ii) LT OCB consisting of 16 Nos OCB switchgear (location : B/W SS) (iii) ICTP panel consisting of 15 Nos ICTP main switches
Dismantling/removing existing LT panel board of any size and capacity after removing all cables/earthing connections , shifting to a location inside dockyard including stacking for further disposal action all as specified and as directed.
Dismantling/removing existing cope box of any size complete with all accessories shifting to a location inside dockyard including stacking for further disposal action all as specified and as directed.
Taking out old unserviceable HT cable of Pilca 185 Sq mm size,3 core from cable duct, hangers, wall or floor carefully, shifting including stacking for further disposal action all as specified and as directed.
Taking out old unserviceable, copper LT cables of 400 sq mm size, 3.5 core from cable duct, hangers, wall or floor carefully, shifting including stacking for further disposal action all as specified and as directed.
Supply and laying electric rubber mat of size 2m x 1 m x 20 mm size, elastomer free from any insertion, combination of natural rubber and other synthetic polymers, conforming to IS -15652, tolerance upto ±10% on thickness, ±5% on length, ±2% on width, Class A upto 3.3 KV duly lSI marked all as specified and as directed.
Supply and laying electric rubber mat, 2m x 1 m x 25 mm size, elastomer free from any insertion, combination of natural rubber and other synthetic polymers, conforming to IS -15652, tolerance upto ±10% on thickness, ±5% on length, ±2% on width,Class "B" upto 11 KV duly lSI marked all as specified and as directed.
Supply and fixing industrial plug with cable gland, suitable for panel mounted receptacle, 415 Volts, AC, 50 Hz, 200 Amps,4 pole, sea water resistant, confirming to IP 67, IEC 309-1, EN 6309-1 all as specified and as directed.
Supply, installation, testing, commissioning electronic based APFC panel outdoor type having aggregate capacity: 50 KVAR in 09 stage, microprocessor based along with factory made type panel weather proof, vermin proof, fully ventilated both side opening and fabricated out of CRCA sheet 3.00 mm thick & frame angle of size 50mm x 50mm x 6mm having bus bar of Aluminium 200 Amps capacity, three phase and one neutral fixed on insulator and bus bar insulated by colored heat shrinkable sleeve & housed in specified compartment including powder coating internally & externally the entire steel surfaces, cover having suitable locking arrangements, fully internally wired with suitable size of thimbles, incoming/outgoing internal connection with PVC insulated PVC sheathed multi stranded copper wire of suitable size all as specified and as directed and comprising the following :- (a) Power supply : 3 phase 4 wire line (b) Power rating: 50 KVAR (c) Rated system voltage: 440volts, 50Hz (d) Duty : continuous (e) Main incoming MCCB 125 Amp, 36KA, 4 pole - 01 No
Supply, installation, testing, commissioning electronic based APFC panel outdoor type having aggregate capacity 100 KVAR in 12 stage, microprocessor based along with factory made type panel weather proof, vermin proof, fully ventilated both side opening and fabricated out of CRCA sheet 3.00 mm thick & frame angle of size 50mm x 50mm x 6mm having bus bar of Aluminium 300 Amps capacity, three phase and one neutral fixed on insulator and bus bar insulated by colored heat shrinkable sleeve & housed in specified compartment including powder coating internally externally the entire steel surfaces, cover having suitable locking arrangements, fully internally wired with suitable size of thimbles, incoming/outgoing internal connection with PVC insulated PVC sheathed multi stranded copper wire of suitable size all as specified and as directed and comprising the following :- (a) Power supply: 3 phase 4 wire line (b) Power rating : 100 KVAR (c) Rated system voltage: 440votts, 50Hz (d) Duty: continuous (e) Main incoming MCCB 200 Amp 36KA 4 pole - 01No
Supply, installation, testing, commissioning electronic based APFC panel outdoor type having aggregate capacity 150 KVAR in 15 stage, microprocessor based along with factory made type panel weather proof, vermin proof, fully ventilated both side opening and fabricated out of CRCA sheet 3.00 mm thick & frame angle of size 50mm x 50mm x 6mm having bus bar of Aluminium 600 Amps capacity, three phase and one neutral fixed on insulator and bus bar insulated by colored heat shrinkable sleeve & housed in specified compartment including powder coating internally externally the entire steel surfaces, cover having suitable locking arrangements, fully internally wired with suitable size of thimbles, incoming/outgoing internal connection with PVC insulated PVC sheathed multi stranded copper wire of suitable size all as specified and as directed and comprising the following :- (a) Power supply: 3 phase 4 wire line (b) Power rating: 150 KVAR (c) Rated system voltage: 440volts, 50Hz (d) Duty: continuous (e) Main incoming MCCB 400 Amp 36KA 4 pole - 01No
Supply, installation, testing, commissioning electronic based APFC panel outdoor type having aggregate capacity 180 KVAR in 17 stages, microprocessor based along with factory made type panel weather proof, vermin proof, fully ventilated both side opening and fabricated out of CRCA sheet 3.00 mm thick & frame angle of size 50mm x 50mm x 6mm having bus bar of Aluminium 600 Amps capacity, three phase and one neutral fixed on DMC insulator and bus bar insulated by colored heat shrinkable sleeve & housed in specified compartment including powder coating internally externally the entire steel surfaces, cover having suitable locking arrangements, fully internally wired with suitable size of thimbles, incoming/outgoing internal connection with PVC insulated PVC sheathed multi stranded copper wire of suitable size all as specified and as directed and comprising the following :- (a) Power supply: 3 phase 4 wire line (b) Power rating: 180 KVAR (c) Rated system voltage: 440 volts, 50Hz (d) Duty: continuous (e) Main incoming MCCB 400 Amp 36KA 4 pole - 01No (f) Power factor corrector relay 17 stage-01 No
(iii) Pre dispatch inspection shall be carried out by the authorized representative of Accepting Officer. In case of any deviation from approved drawing, the same shall be rejected and fresh LT panel shall be got fabricated from the manufacturer. Testing shall be done at manufacturer’s premises and all routine tests like IR and continuity tests shall be performed/recorded in presence of authorized representative of Accepting Officer. (iv) The panel manufacturer shall have following certification : (a) CPRI certification Degree of protection of IP-54 (shall have IEC:61439-1 -2 & IEC:60529 tests) (b) CPRI certification short circuit with stand strength shall be 50 KA RMS for 1 sec with initial peak of 105 KA. (c) CPRI certification rated current for short circuit not less than 6000A (v) MCCB (microprocessor based) / ACBs provided shall be capable for online setting of the current.
(vi) ACBs provided shall be capable for online setting to the time delay. (vii) All the electrical switch gear like MCCBs, MCBs and ACBs shall be of same make. (viii) All incomer ACBs and MCCBs (microprocessor based) shall be compatible with SCADA through communication port. (ix) Drawing of panel board shall be got from GE before fabrication. (x) Panel board shall be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
Total amount of Sch 'A' Part VII-B C/o to General Summary on Ser Page No. 203(R)
SCHEDULE 'A' PART-VIII-B (REPAIRS TO WHARF, REPAIRS TO UNDER JETTY PLATFORM, REPAIRS TO SERVICE PITS, WOODEN COPING AND CAPSTAN FILLING, REPAIRS TO RCC CABLE TRENCH)
Material and labour for preparing existing concrete floor/slab with broom, then with water jet and then with air compressor and removing of loose concrete/dirt's etc. from repairs to the slab top surface and repeating above cleaning procedure, applying primer coat such as Nitobond PVA of FOSROC or equivalent on cleaned surface, providing and laying self levelling cementitious compound Nitoflorlevelcrete of FOSROC / MC floor level of MC Bauchemie / Sika floor level 25 of Sika not exceeding 75 mm etc. as per manufacturer's instructions complete all as specified and as directed.
Material and labour for providing and fixing of shear connectors of Fe 500 and of 10 mm dia , 200 mm length in drilling holes of 14 mm dia for depth of 100 mm in the beam under platform jetty, providing and injecting epoxy Sikadur 31 IN of Sika/Lokfix of Fosroc or equivalent in the holes and placing the shear connectors in position and allowing it to remain undisturbed till epoxy is set etc. complete all as specified and as directed. Note :- Rate shall be deemed to include cost of cleaning of holes with air compressor or water jet to remove all the dust etc.
Material and labour for providing and applying Epoxy Zinc rich Nitozinc of Fosroc/MC Dur ZKE of MC Bauchemie/Sika Zinc Rich 2 of Sika or equivalent primer to old and new reinforcement (dia of reinforcement 8 to 32 mm) including cleaning reinforcement with wire brush and then with an alkaline rust remover etc. complete all as specified and as directed.
Material and labour for providing and applying epoxy bond coat Nitobond SBR of Fosroc/Zentrifix KMH of MC Bauchemie or equivalent etc. to concrete surfaces complete all as specified and as directed.
Material and labour for micro concrete of M-35 Renderoc RG of Fosroc/Sika Rep Microconcrete 4 of Sika/Emcekrete type A of MC Bauchemie including providing necessary steel formwork etc. complete all as specified and as directed.
Supply and fixing stainless steel 316 grade angle 75 x 75 x 8 mm and all necessary connected items etc. complete all as specified, as shown in drawing and as directed.
Supply and fixing 10 mm thick stainless steel grade 347 matte finish plate etc. and all necessary connected items complete all as specified, as shown in drawing and as directed.
Material and labour for 12 mm dia Hilti anchor fastener HIT-V-R M12, 150 mm long embedment depth inside concrete, drilling the required hole as per dia of the anchor rod with Hilti safe set system with automatic cleaning after drilling 14 mm hole, injecting RE 500 V3 with the help of HDM 500 dispenser, after injecting chemical and letting it rest for 12 hours after this, loading the anchor/placing base plate/angle and tightening the nut for the anchor without damaging existing adjacent concrete and to fix rag/holding down bolt etc. complete all as specified and as directed.
Material and labour for painting old and new steel surface with two component polyamine coated epoxy coating as per specification, application methodology of manufacturer etc. complete all as specified and as directed.
Material and labour for providing and applying epoxy bond coat Nitobond SBR of FOSROC/Zentrifix KMH of MC Bauchemie or equivalent including preparing existing concrete floor/slab with broom, then with water jet and then with air compressor and removing of loose concrete/dirt for wooden coping etc. complete all as specified and as directed.
Material and labour for micro concrete of M-35 Renderoc RG of Fosroc/Sika Rep Microconcrete 4 of Sika/Emcekrete type A of MC Bauchemie including providing necessary steel formwork etc. also for wooden coping complete all as specified and as directed.
Material and labour for 24 mm dia Hilti anchor fastener AM ROD (8.8) M24, 650 mm long and 300 mm embedment depth inside concrete, drilling the required hole as per dia of the anchor rod with Hilti safe set system with automatic cleaning after drilling 28 mm hole, injecting RE 500 V3 with the help of HDM 500 dispenser after injecting chemical and letting it rest for 12 hr. after this, loading the anchor/placing baseplate/angle and tightening the nut for the anchor without damaging existing adjacent concrete and fixing rag/holding down bolt for wooden coping etc. complete all as specified and as directed.
Material and labour for providing and applying 50 mm thick epoxy mortar to the concrete surface within 15 min of applying bonding agent, thickness of such epoxy mortar not exceeding 25 mm per layer and providing suitable curing compound like Concure WB of FOSROC/ MASTERKURE 181 of BASF or equivalent in a continuous, uniform film without pinholes by low pressure spray, roller or brush in the manner specified by the manufacture complete all as specified and as directed. Note :- The rate shall be deemed to include cleaning by wire brush and drying for service pits etc.
Material and labour for providing and applying epoxy bond coat Nitobond EP of FOSROC/MC Dur 1200 of MC Bauchemie/Sikadur 32 or equivalent for service pits etc. complete all as specified and as directed.
Material and labour for 12 mm dia Hilti anchor fastener HIT-V-R M12, 150 mm long embedment depth inside concrete, drilling the required hole as per dia of the anchor rod with Hilti safe set system with automatic cleaning after drilling 14 mm hole, injecting RE 500 V3 with the help of HDM 500 dispenser, after injecting chemical and letting it rest for 12 hours after this, loading the anchor/placing base plate/angle and tightening the nut for the anchor without damaging existing adjacent concrete and to fix rag/holding down bolt etc. complete all as specified and as directed.
Material and labour for applying two coats of epoxy paint over a coat of primer including preparation on all steel surface as per manufacturer's instruction for service pits etc. complete all as specified and as directed.
Material and labour for Siporex light weight blocks for filling for capstan pits etc. all as specified and as directed.
Cleaning of RCC wall surfaces with wire brush and compressed air and removal of unwanted material etc. complete all as specified and as directed.
Material and labour for 15 mm thick polymer modified mortar Renderoc HB2 of FOSROC/MC Mineroplast of MC Bauchemie/Sika plaster mix of Sika over priming agent Nitobond HAR of Fosroc or equivalent (application shall be done using stiff brush) etc. complete all as specified and as directed.
Removing loose concrete in cracks and cleaning the surface by using air compressor, open up cracked surface by V notch or groove of size 12 mm x 12 mm, drilling holes of 16 mm dia and 50mm to 100 mm depth along the crack lines at spacing 250 mm and removing loose debris and dust in opened cracks and holes by air compressor or with hand operated blower, inserting 12 mm dia PVC nozzles in holes and fixing them using with Polymer modified mortar such as Renderoc Plug of Fosroc/MC Fix ST of MC Bauchemie/Sika 102 of Sika and sealing the cracks by polymer modified mortar etc. complete all as specified and as directed.
Material and labour for 16 mm dia Hilti anchor fastener 175 mm long embedment depth inside concrete, drilling the required hole as per dia of the anchor rod with Hilti safe set system with automatic cleaning, after drilling 18 mm hole, injecting RE 500 V3 with the help of HDM 500 dispenser, after injecting chemical and letting it rest for 12 hrs after this, loading the anchor/placing base plate / angle and tightening the nut for the anchor without damaging existing adjacent concrete and fixing rag/holding down bolt etc. complete all as specified and as directed.
Material and labour for 12 mm dia Hilti anchor fastener HIT-V-R M12, 150 mm long embedment depth inside concrete, drilling the required hole as per dia of the anchor rod with Hilti safe set system with automatic cleaning after drilling 14 mm hole, injecting RE 500 V3 with the help of HDM 500 dispenser, after injecting chemical and letting it rest for 12 hours after this, loading the anchor/placing base plate/angle and tightening the nut for the anchor without damaging existing adjacent concrete and to fix rag/holding down bolt etc. complete all as specified and as directed.
Material and labour for applying two coat of epoxy paint over two coat primer including preparation on all new steel surface as per manufacturer's instruction etc. complete all as specified and as directed.
Material and labour for complete removal of existing treatment from old steel surface and applying two coats of epoxy paint over two coat primer as per manufacturer's instruction etc. complete all as specified and as directed. NOTE FOR ALL ITEMS OF SCHEDULE 'A' PART VIII-B : The rate quoted shall be deemed to be inclusive of necessary safety measure under pinning existing structure during execution of work.
Total amount of Sch 'A' Part VIII-B C/o to General Summary on Ser Page No. 204(R)
SCHEDULE 'A' PART-IX-B (EXTENSION OF PUMP HOUSE AND CONSTRUCTION OF SHEDS)
Material & Labour for preparation of newly plastered surface and applying two coats of Acrylic emulsion paint (exterior grade) over a coat of primer on external wall complete all as specified and as directed.
Material and labour for removal of existing treatment from surface of any description and applying two coats of Acrylic emulsion paint (exterior grade) over a coat of primer including preparation of external wall etc. complete all as specified and as directed.
Material and labour for applying two coats of epoxy paint over a coat of primer including preparation on all steel surface as per manufacturer's instruction complete all as specified and as directed.
Material & Labour for aluminium anodized sliding windows with standard sections including shutters, window frames, handle, cleat, rubber packing, aluminium beading, screws, locking, fixing arrangement and including 4 mm thick ordinary glass pane etc. complete as per drawing and as per manufacturer's instructions complete all as specified and as directed
Supply and fixing 16 Gauge GI Wire mesh any size or any type (not exceeding 3 kg/Sqm) including line wires, any mesh, to any type of standards, rails, straining bolts, etc. including provision of binding wire etc. complete all as specified and as directed.
Material and labour for applying two coats of epoxy paint over a coat of primer including preparation on all steel surface as per manufacturer's instruction complete all as specified and as directed.
Material and labour for 16 mm dia Hilti anchor fastener (HIT V-R M 16) 200 mm long embedment depth inside concrete, drilling the required hole as per dia of the anchor rod with Hilti safe set system with automatic cleaning, after drilling 18 mm hole, injecting RE 500 V3 with the help of HDM 500 dispenser , after injecting chemical and letting it rest for 12 hours after this, loading the anchor/place base plate/angle and tighten the nut for the anchor without damaging existing adjacent concrete and to fix rag/holding down bolt etc. complete all as specified and as directed.
Total amount of Sch 'A' Part IX-B C/o to General Summary on Ser Page No. 204(R)
SCHEDULE 'A' PART-X-B (DEMOLITION/DISMANTLING)
Dismantling capstan and necessary connecting machines and pumps and removing from the site by manually or mechanically without causing stresses to existing structures and including deployment of heavy machinery and after removal and handing over to user complete all as specified and as directed.
Total amount of Sch 'A' Part X-B C/o to General Summary on Ser Page No. 204(R)
SCHEDULE 'A' PART-XI-B (EXCAVATION AND EARTH WORK)
Removing excavated material (soil) to a place outside defence land including loading, unloading, transportation , levelling and any other charges complete all as specified.
Removal of silt (accumulated) from the cable trench and removing outside defence land and disposing including loading, unloading, transportation , levelling and any other charges complete all as specified and as directed.
Boring of holes under road pavement, hardstanding by trenchless technology using untra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.40 MPA working pressure complete all as specified and as directed.
Total amount of Sch 'A' Part XI-B C/o to General Summary on Ser Page No. 205(R)
GENERAL SUMMARY
Total Amount of Schedule ‘A’ Part I for “BUILDING” brought forwarded from Serial Page No 30(R)
Lump sum price worked out by the contractor for “PILE FOUNDATION” as listed in Schedule ‘A’ Part II-A
Total Amount of Schedule ‘A’ Part II-B for “PILE FOUNDATION” brought forwarded from Serial Page No 34(R)
Lump sum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part III-A
Total Amount of Schedule ‘A’ Part III-B for “INTERNAL ELECTRIFICATION” brought forwarded from Serial Page No 40(R)
Lump sum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part IV-A
Total Amount of Schedule ‘A’ Part IV-B for “EXTERNAL WATER SUPPLY” brought forwarded from Serial Page No 49(R)
Lump sum price worked out by the contractor for “FIRE FIGHTING” as listed in Schedule ‘A’ Part V-A
Total Amount of Schedule ‘A’ Part V-B for “FIRE FIGHTING” brought forwarded from Serial Page No 55(R)
Lump sum price worked out by the contractor for “L P AIR SUPPLY” as listed in Schedule ‘A’ Part VI-A
Total Amount of Schedule ‘A’ Part VI-B for “L P AIR SUPPLY” brought forwarded from Serial Page No 60(R)
Lump sum price worked out by the contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part VII-A
Total Amount of Schedule ‘A’ Part VII-B for “EXTERNAL ELECTRIFICATION” brought forwarded from Serial Page No 154(R)
Lump sum price worked out by the contractor for “REPAIRS TO WHARF, REPAIRS TO UNDER JETTY PLATFORM, REPAIRS TO SERVICE PITS, WOODEN COPING AND CAPSTAN FILLING, REPAIRS TO RCC CABLE TRENCH” as listed in Schedule ‘A’ Part VIII-A
Total Amount of Schedule ‘A’ Part VIII-B for “REPAIRS TO WHARF, REPAIRS TO UNDER JETTY PLATFORM, REPAIRS TO SERVICE PITS, WOODEN COPING AND CAPSTAN FILLING, REPAIRS TO RCC CABLE TRENCH” brought forwarded from Serial Page No 171(R)
Lump sum price worked out by the contractor for “EXTENSION OF PUMP HOUSE & CONSTRUCTION OF SHEDS” as listed in Schedule ‘A’ Part IX-A
Total Amount of Schedule ‘A’ Part IX-B for “EXTENSION OF PUMP HOUSE & CONSTRUCTION OF SHEDS” brought forwarded from Serial Page No 184(R)
Lump sum price worked out by the contractor for "DEMOLITION/DISMANTLING" as listed in Schedule ‘A’ Part X-A
Total Amount of Schedule ‘A’ Part X-B for “DEMOLITION/DISMANTLING” brought forwarded from Serial Page No 188(R)
Lump sum price worked out by the contractor for "EXCAVATION AND EARTHWORK" as listed in Schedule ‘A’ Part XI-A
Total Amount of Schedule ‘A’ Part XI-B for “EXCAVATION AND EARTHWORK” brought forwarded from Serial Page No 191(R)
UBC Engineers Pvt Ltd
MC Gandhi and Sons
Som Projects Pvt Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid