Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹53.8 LAccepted-Finance | L-1 | Accepted-Finance ACCEPT | |
| 2 | L-2₹58.3 L+₹4.5 L (8.42%)Accepted-Finance 0 VILLAGE CHAMPANER NAGLA BALLAM POST SANTOSHPUR GHAT ETAWAH UTTAR PRADESH 206253 | ETAWAH | UTTAR PRADESH | 206253 | L-2 | Accepted-Finance ACCEPT | |
| 3 | L-3₹59.2 L+₹5.4 L (10.0%)Accepted-Finance 2 1433 D 6 KAMAL COLONY SAHARANPUR UP PIN 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L-3 | Accepted-Finance ACCEPT |
| Sl No | Description | Qty | Unit | M/s Radha Krishan L2 | SANDHYA TRADERS L1 | M/S Sushil Kumar L3 |
|---|---|---|---|---|---|---|
| 1.00Carriage of the following material from Store Center, Etawah to 33/11 KV S/S to direct pit site in distance range 0 to 50 Km. Including loading & unloading at both ends. including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. | ||||||
| 2.00 | STP 55 Pole 11 Mtr Long | 102 | Nos | - | - | - |
| 3.00 | PCC Pole 8.5 Mtr | 46 | Nos | - | - | - |
| 4.00 | ACSR Weasel Conductor | 3,525 | Mtr. | - | - | - |
| 5.00 | ABC Conductor 3x95 Sqmm | 5,274 | Mtr. | - | - | - |
| 6.00 | ABC Conductor 2x16 Sqmm | 250 | Mtr. | - | - | - |
| 7.00 | 16 KVA Transformer 11/0.4 kv | 10 | Nos | - | - | - |
| 8.00 | 25 KVA Transformer 11/0.4 kv | 4 | Nos | - | - | - |
| 9.00 | 63 KVA Transformer 11/0.4 kv | 4 | Nos | - | - | - |
| 10.00 | 100 KVA Transformer 11/0.4 kv | 29 | Nos | - | - | - |
Tender Value
Refer Docs
EMD Value
₹53,000
Closing Date
5 May 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC ETAWAH
STATION ROAD ETAWAH
209/EDCE/2023-24
2024_DVVNL_922775_2
209/EDCE/2023-24
Open Tender
Repair and Maintenance Works
Item Wise
180 days
EDC Etawah
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
DVVNL.ORG
₹53,000
9 Sept 2025
30 Apr 2024
5 May 2024
30 Apr 2024
5 May 2024
30 Apr 2024
Carriage of the following material from Store Center, Etawah to 33/11 KV S/S to direct pit site in distance range 0 to 50 Km. Including loading & unloading at both ends. including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.
STP 55 Pole 11 Mtr Long
PCC Pole 8.5 Mtr
ACSR Weasel Conductor
ABC Conductor 3x95 Sqmm
ABC Conductor 2x16 Sqmm
16 KVA Transformer 11/0.4 kv
25 KVA Transformer 11/0.4 kv
63 KVA Transformer 11/0.4 kv
100 KVA Transformer 11/0.4 kv
Supply Of Following Materials for Completion Of Work.
Suspension Clamp
Dead End Clamp
Distribution Box 03 Phase
Distribution Box Clamp
PVC/Cable Connector
11 Kv Disc Insulator with fitting
11 Kv Pin Insulator fitting with Pin
11 Kv X-arm V type
11 Kv Top Channel
Earthing Rod Complete
Stay Set Complete with Clamp
Holding Clamp
Nut and Bolt
M.S. T/F Base Angle
11 Kv Fuse Set
I-Hook
Laying sagging stringing, binding, jumpering & fixing of all accessories which required of following conductor on the erected pole as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc required for proper completion of work.
ACSR Weasel
ABC 3x95 sqmm
ABC 2x16 sqmm
Errection of STP-55 11 Mtr long pole as single support including fixing of all accessories etc, grouting and plinth as per RESPO norms.
Errection of STP-55 11 Mtr long pole as double support including fixing of all accessories etc, grouting and plinth as per RESPO norms.
Errection of PCC 8.5 Mtr long pole as single support including fixing of all accessories etc and other work complete as per RESPO norms.
Errection of PCC 8.5 Mtr long pole as double support including fixing of all accessories etc and other work complete as per RESPO norms.
Earthling of Pole with MS Earth Rod as per RESPO Specification. (Earth Rod Provide by Contractor)
Installation of Stay rod. Etc. complete. (Stay Rod Provide by Contractor)
Mounting of 16 KVA Transformer on the Double pole structures with connections thereof.
Mounting of 25 KVA Transformer on the Double pole structures with connections thereof.
Mounting of 63 KVA Transformer on the Double pole structures with connections thereof.
Mounting of 100 KVA Transformer on the Double pole structures with connections thereof.
Earthing fencing and Repairing of damaged 250/400/630 KVA Transformer's Plinth. including the cost of arrangement of labour, materials, T&P, carrier etc. required for proper completion of work.
Chemical Earthing Body & Neutral Of Transformer and connections as per Norms.
FRP Fencing with foldable Gate hieght 1.52Mtr complete work etc.
Repairing Of Plinth If required.
Carriage of old material from pit site to JE store/store center Etawah in distance range 0 to 50 km. including loading & unloading and proper stacking.
M/s Radha Krishan
M/S Sushil Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .