Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹44.6 L+₹5.2 L (13.3%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹45.2 L+₹5.9 L (15.0%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹48.8 L+₹9.5 L (24.1%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹51.3 L+₹12.0 L (30.5%)Rejected-Finance PLOT NO 261 SHANTI KUNJ ALWAR 301415 RAJ | ALWAR | RAJASTHAN | 301415 | L5 | Rejected-Finance Being 5th lowest |
Tender Value
₹47.0 L
EMD Value
₹93,900
Closing Date
19 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
RENOVATION (ADDITION/ALTERATION) OF BLDG NO P-27 (SINGLE OFFRS ACCN) AT OLD CAMP , PTS (VIKAS) SARSAWA UNDER GE(AF) SARSAWA
2024_MES_638138_1
8123/SAR-54/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) SARSAWA
₹93,900
Yes
20 Mar 2024
22 Jan 2024
26 Feb 2024
22 Jan 2024
19 Feb 2024
5 Feb 2024
22 Jan 2024 - 5 Feb 2024
Amount
Surface dressing not exc 15cm deep in soft/loose soil complete all as specified and directed by Engr-in-Charge. Note : Removing of vegetation / shrubs / brushwood / undergrowth and carrying away rubbish to a distance of 50 m deemed to included in quoted rate.
Excavating in trenches not exc 1.5m wide and not exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, taking out/laying cable, poles & stay etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft / loose soil complete all as specified and directed.
Earth filling under floors including spreading, leveling, watering and well ramming in each layers not exc 25 cm thick complete all as specified and directed. Note :- Soil obtained from excavation under item 2.00 here-in-before shall be used for filling.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified& directed by Engr-in-Charge.
Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for form work to sides of Pillars, posts, struts piers, columns etc in squarre, rectangular or polygonal, rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to chajjas, chullah hoods, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in foundations including rafts, footings, foundation beams,plinth beams, bases for columns, mass concrete and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate in lintels upto 1.5m clear span, seismic and other similar bands, lintel bands and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in columns, pillars, piers, posts, struts and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded stone aggregate in chajjas and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No.18 above but 5mm dia and over up to & including 10mm dia in stirrups, spacers & binders.
M & L brick work sub class 'B' bricks (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L brick work sub class 'B' bricks , (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
M&L for 50 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
S&F 32mm dia Brass chromium plated bottle traps for wash basins/urinals with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed Complete all as specified
Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified& directed by Engr-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floor and paving. exc. 15 cm thickness (below or above ground level.) & removal of rubbish material complete all as specified& directed by Engr-in-Charge.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate), 25mm thick, as in Sub base complete all as specified & directed by Engr-in-Charge.
M&L for double charge vitrified ceramic tiles 8mm to 9mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
Material and labour coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and over 15mm thick screed bed in CM 1:6 complete all as specified& directed by Engr-in-Charge.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises
M&L for double charge vitrified ceramic tiles 8 to 9mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
M&L Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified& directed by Engr-in-Charge.
Taking down cement plaster any description on brick or stone any description
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in CM 1:4 on stone wall surfaces or other than fair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound ( water proof compound paid seperatly) all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with water proofing admixture (ISI marked) as per manufacturer’s instructions, finished even and smooth without using extra cement complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces of ceiling including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces & applying two coat of OBD (Oil Bound Distemper) on ceiling complete all as specified& directed by Engr-in-Charge.
M&L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over a coat of 1mm thick wall care putty of approved tint complete all as specified & directed by Engr-in-Charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed
M&L for complete removal of existing treatment preparation of old plastered surfaces & applying two coat of OBD (Oil Bound Distemper) on ceiling complete all as specified& directed by Engr-in-Charge.
M&L for complete removal of existing traetment preparation of old plastered surfaces & applying Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on old work over a coat of 1mm thick wall care putty of approved tint complete all as specified & directed by Engr-in-Charge.
Material & Labour for complete removal of existing treatment preparation of old plastered surfaces & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed
M&L preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified.
M&L preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified.
Taking down chowkhats (without taking off shutters from the frames) chowkatts n exc 1.5 sqm each complete all as specified & directed by Engr-in-Charge.
Taking down chowkatts (without taking off shutters from the frames) chowkatts exc 1.5 sq. m but n exc 4 sq m each complete all as specified & directed by Engr-in-Charge.
Taking down shutter of any decription exc.1Sqm and n.Exc 2 Sqm complete all as specified & directed by Engr-in-Charge.
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
M&L Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified& directed by Engr-in-Charge.
S&F 35mm thick factory made IInd class hard wood panelled door shutter with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. the size of rail and stiles as per IS: 1003 (part-I), kiln seasoned and chemically pressure treated and fixed to chowkats complete.
S&F 35 mm thick factory made IInd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats
M&L for preparing of new untreated wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint (of approved shade) over a coat of pink primer all as specified.
S&F stainless steel hinges 100mm long medium weight, complete all as specified & directed by Engr-in-Charge.
S&F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed by Engr-in-Charge.
S&F 150mm Aluminium handles, cast type, anodised complete all as specified & directed by Engr-in-Charge.
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp ,staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F anodized aluminium frame and other sections for doors, windows, ventilators, partitions, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed.
S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed.
S&F anodized aluminium grill with power coating (minimum thickness 50 micron) of approved pattern and fixed to the existing window/ventilator frame with CP brass/stainless steel scrwed @ 200mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement & directed by Engr-in-Charge.
S&F anodized aluminium door shutters, aluminium section weighing 0.55 kg/m, with power coating (minimum thickness 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodized aluminum snap beading screws etc. complete all as specified & as directed.
S&F door closer hydraulically regulated, designation No. 2, aluminium (Die cast) body, universal type (ISI marked) suitable for door shutters of 701 to 850mm in width aand weight between 36 to 60 Kg and fixed complete all as specified & as directed.
S&F 4.8mm thick Sheet glass, ordinary quality and glazing with rubber bedding in square n exc 0.5 sq.m in each pane complete all as specified & directed by Engr-in-Charge.
S&F 5mm thick frosted glass with rubber bedding in square n exc 0.5 sq.m in each pane complete all as specified & directed by Engr-in-Charge.
Taking up or down 15mm steel tubing and connections, complete all as specified& directed by Engr-in-Charge.
Taking up or down 20mm steel tubing and connections, complete all as specified & directed by Engr-in-Charge.
S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floor all as specified.
S&F steel tubing medium grade 20mm bore Medium grade fix to wall/floor fixed complete all as specified.
Dismantling water tanks of capacity exc 250ltr but not exc 500ltr and removing from site complete all as specified & directed by Engr-in-Charge.
S&F Rotational moulded polyethylene triple layer water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified icomplete all as specified & directed by Engr-in-Charge.
S&F ball valves brass high pressure with polythelene float and fly net complete, screwed , iron pipes 15 mm dia complete all as specified & directed by Engr-in-Charge
S&F as in repair Sand cast,100 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors and including dismentling old u/s pipes complete
S&F as in repair Sand cast,100 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in wall and including dismentling old u/s pipes complete
S&F as in repair Sand cast,75 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors and including dismentling old u/s pipes complete
S&F as in repair Sand cast,75 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in wall and including dismentling old u/s pipes complete
S&F in repair CI Bends 100 mm dia (any radius),diminishing pieces or tapers (larger bore measured) complete all as specified
S&F in repair CI Bends 75 mm dia (any radius),diminishing pieces or tapers (larger bore measured) complete all as specified
S&F as in repair 100mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified
S&F as in repair 75mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified
S&F for 150mm x150mm Salt-glazed stoneware gully traps, square or round mouthed, type 'P' including dismsntling old trap complete all as specified
S/F kitchen sink with draining board made out of stainless steel 1mm thick with plugs, washers and waste pipe including bedding in cement mortar to dwarf wall or including and fixing cast iron cantilever brackets and connecting union to pipe over all size 495x420 mm bowl size 410x330x160 mm including flush pipe of polyethylene of low or high density or PVC 32mm bore with long screwed shanks and fly nuts complete all as specified & directed by Engr-in-Charge.
S&F in repair fancy type bib taps, chromium plated alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule and fixed omplete all as specified & directed by Engr-in-Charge.
S&F in repair fancy type angle valves, chromium plated alloy screwed down high presure, screwed both ends for iron pipe or for unions of 15 mm dia long sunk concealed type complete all as specified & directed by Engr-in-Charge.
S&F in repairs PVC connection of 15mm bore with 2 Nos. PTMT nuts, 45cm long fixed with one end to pillar tap & the other end to stop cock or iron pipe all as directed by Engineer-in-charge. Make- PRAYAG.
S&F in repair towel rails of 20mm dia tubular brass chromium plated 60cm long 'D' type fixed to all as directed by Engr-in-charge
Supply and fixing in repairs MS grating CP 100mm dia, with hole/without for waste pipe of approved make including fixing with CM to floor/nahani traps etc complete all as directed.
S&F in repairs brass chromium plated telephonic hand shower with 1.50m long stainless steel braided flexible tube with nut & nipple & hook suitable for wall mixer & screwed down for iron pipe of 15mm bore all as specified and as directed.
S&F in repairs brass chromium plated shower rose 125mmx125mm size with swivel joint type including fixing to steel pipe of 15mm bore or union complete all as specified.
S&F in repairs of 300 mm dia with SS railing glass corner shelf complete all as specified & as directed.
S&F in repairs of size 600mm x 100mm with SS railing glass shelf rectangular type complete all as specified & as directed.
S&F chromium plated Brass health faucet for EWC with including PVC Connection 1m long suitable for 15mm bore with all connected fittings.as approved by the GE.
M&L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete
M&L for cement mortar 1:4 Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring or brick wall etc., and making good, cutting exc 10 cm girth but not exc 20cm girth complete all as specified and directed
M&L Steel work in tubular trusses/pipe including special shaped washer, fastener, welding etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 Complete all as specified
M&L painting to new or previously untreated steel surfaces of any description over 10cm in width or girth with two coats of synthetic enamel paint over a coat of zinc chromic primer including preparation of surfaces.
M&L Pre- painted galvatume aluminum zinc coating GI based Semi-corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Demolition of cement concrete in reinforced (reinforcement cut as required to facilitate demolition (Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete
S&F in repair for 18/19mm thick High Density High Moisture Resistant board (HDHMR) Prelaminated both sides as in Controller's Desk ,palmed boxes,showcase,shutters of Cup Boards etc including 6mm designing teak wood beading on edges complete all as specified and as directed by Engr-in-Charge.
S&F 75mm extruded brass handles, fabricated type polished complete all as specified & directed by Engr-in-Charge.
S & F Width of flaps (when open) 30mm Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified & directed by Engr-in-Charge.
Demolition Mud in roofs, any thicknes,any material including plastering ,brick bats, existing tretement and cleaning (whether full thickness removed or only or part there of) etc in all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed by Engr-in-Charge.
M&L for providing cement concrete in type B0 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in roof padding, laid to (consolidated thickness 65mm or less) as leveling course, laid and compacted in min slope 1:30 over roof complete all as specified& directed by Engr-in-Charge.
M&L screed laid 15mm thick in CM 1:4 as in roof over green concrete surface finished even and smooth using Lequid WPC complete all as specified. Note :-Lequid WPC will be measured and paid seperately)
M&L for Providing and laying prepolished cement concrete Chequered tiles 30cmx30cmx25mm thick, with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape heavy duty , set,jointed and pointed in neat cement slurry in floors over screed bed 15mm thick 1:6 cement mortar complete all as specified& directed by Engr-in-Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified.
S&F in repair Brass chromium plated towel rack 24 " long, fixed in position with steel screws complete all as specified.
S&F in repair 155mm dia towel ring of chromium plated fixed to all as directed by Engr-in-charge
S&F in repairs fancy type center hole basin mixer without popup waste system but including plain waste 32 mm size with aerator complete cast copper alloy, chromium plated, scrwed downhigh pressure, with long scrwed shanks & fly nuts scrwed for iron pipes of 15 mm bore complete all as specified & as directed.
S&F in repairs wall mixer chromium plated (3 in -1) with arrangement for both telephonic shower and overhead shower with 220 mm max long bend pipe with hand shower of size 100 x 55 mm with 130 mm long arm & 1.2 m house pipe complete all as specified & directed.
S&F in repairs wall mixer chromium plated (3 in -1) with arrangement for both telephonic shower and overhead shower with 220 mm max long bend pipe with hand shower of size 100 x 55 mm with 130 mm long arm & 1.2 m house pipe complete all as specified & directed.
S&F in repair 15 mm dia 2 way CP angle cock complete all as specified and directed by Engr-in-Charge.
S&F stainless steel drapery rod of 25 mm inner dia (in lengths as directed) of approved colour with & including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam, including PVC curtain rings of matching colour @ 10cm C/C complete all as specified and directed.
S&F Mirror Cabinet PVC frame of size 400x500mm fixed to wall with rawl plug & stainless steel suitable size scrweds complete all as specified and directed.
S&F DOOR SEAL BOTTOM, DOOR AIR GAP RUBBER SHIELD (Best Quality) Anti Rust , Brown/white/balck colour, Black Rubber Complete all as specified
S&F in repairs vitreous china counter top/down basin size 450 x 525 x 195 mm shape oval including 32 mm CP waste coupling & PVC flexible waste pipe of 90 cm long complete all as specified & directed.
S&F in repairs vitreous china wash down water closet pan one pice (Pedestal pattern EWC), coloured, floor mounted coupled closet, including connection to drain (or outgoing pipe), anti-sypohonage pipe etc, with & including WC seat cover coloured closed pattern with flat bottom and cover, CP jet nozzle, vitreous china symphonic action type twin flush flushing cistern of 10 litre capacity with lid, necessary fittings complete all as specified & as directed.
S&F FAST DM01SS Stainless Steel Furniture Door Catcher Magnet Size No. 2 for for Wadrobe, Cupboard and Almirah Door. (SS MAT) with Mounting Screw complete all as specified
S&F in repairs 15mm dia Sink Mixer chromium plated hot and cold system complete all as specified & directed.
S&F stainless steel Kitchen plate rack of overall minimum size 900mm x 750mm and 230mm deep, with partitions for small/large plates etc made out of stainless steel 24 Gauge, fixed with rawl plug and CP steel screws all as directed. Note : Weight of rack shall not be less than 6 Kg.
Taking down cement plaster or other existing treatment from sunken floors, cleaning the surface with wire brushes, brooms etc and finally washing down the area to be treated. M & L for treating the sunken floors and adjoining vertical surfaces as under: (a) Plastering 15 mm in CM 1:3 mixed with liquid type water proofing compound to sunken floors and adjoining vertical surfaces. Surface shall be cured & allowed to dry. (b) Applying Ist layer of cement slurry by brush@ 0.488 Kg per Sqm mixed with acrylic based polymer modified cementeous compound of Dr Fixit @ .253 Kg per Sqm complete as per manufacture instructions. (c) Applying 2nd layer of cement slurry by brush@ 0.488 Kg per Sqm mixed with acrylic based polymer modified cementeous compound of Dr Fixit @ .253 Kd per Sqm complete as per manufacture instructions. (c) Testing the sunken floor for water tightness by ponding water for 72 Hours. (d) Fixing of 32mm dia GI pipe medium grade spout projecting 23 cm beyond wall, one number in each sunken portion. complete all as specified and directed .
M&L for roof treatment using APP based polymeric membrane minimum weighing not less than 3kg/sqm black finish reinforced with non woven polyster matt with thermo finish (wt. not less than 150 gms/sqm) laid over compatible bitumen primer @0 .30 liters per sqm and bitumen 85/25 @ 1.20 Kg per Sqm with help of torching with a proplyne or a butane gas using torch with minimum overlap of 75mm at side and 100mm at ends and sealing including applying a coat of bitumen primer & bitumen 85/25 applied hot all as per manufacturer instructuions. For parapet in a groove (No separate payment will be made and measurement will be done for horizontal surfaces) including applying a coat of heat repallant bitumen aluminium paint @ 0 .1 liter per Sqm on topof treated surface of roof complete all as specified and directed.
M & L for concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover (cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :- One light / fan point controlled by one way switch
All as per above item No-125 here in before but One 5 Amp socket outlet on independent board.
All as per above item No-125 here in before but One 5 Amp socket outlet on same board.
All as per above item No-125 here in before but One bell/buzzer point controlled by one bell push
All as per above item No-125 here in before but One light point controlled by two 2-way switch
All as per above item No-125 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
S&F of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S&F sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V including connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.
S&F in of Double door distribution board 4 way TPN when MCB to be used as incomer powder coated with Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, complete all as specified and directed (Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.) Make-Havells/Indoasian/Legrand.
Supply and fixing modular type AC box 3 module operated with 20 Amp single pole MCB including 15 amp modular socket and plug top complete all as specified and directed by the Engr-in-charge.
S&F MCB TPN 63 Amps, 415 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F MCB SP 5 to 40 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F MCB SPN 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
Supply and fixing Earthing to DBs with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
M & L for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall in and including 15 mm bore GI pipe medium grade for protection of earth wire complete all as specified and directed.
S&F enviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting with pressure die cast aluminium housing ,high efficient LEDs with opal diffuser and IP65 protectio, lumen efficacy 85 lm/watt with colour temerature 6500K, THD≤ 20 CRI>80,2.5 kV surge protection all as specified and directed.
S&F enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
S&F of enviroment friendly indoor decorative 9/10 Watt LED Aluminium Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
Supply and fixing of PVC round shape junction box cover of suitable size including fcomplete all as specified and as directed.
Supply & fix wall mounting fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in-Charge.
S&F plastic body ventilation fan 250 mm 50 Hz , 240 volt 1250 RPM with copper wound motor including all fixing accessories complete all as specified and directed.Make- Orient/Crompton/Bajaj
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, 1400 RPM, blades, and frame and louver complete with making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and as directed by Engr-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engr-in-Charge.
S&F in socket outlet 6A/16A-5 pin multipurpose combined 2 module modular type complete all as specified and directed.
S&F switch 16 amps modular type one module one way complete all as directed.
S&F in switch 6 amps modular type one module one way complete all as directed.
S&F in replacement socket outlet 6A- 5 Pin 2 module modular type complete all as specified and directed.
S & F in replacement of modular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified as as directed.
S & F In replacement of modular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and as directed.
S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and directed.
S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed.
S & F in replacement of Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified as directed
Supply and fix electric water heater, storage type outer body made out of ABS & PP, heating element of 2 KW storage capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, SS braided connection pipe, temperature control knob etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection with 4KV driver builtin sugre protection & additional 10KV surge protection device, system lumens 3500 lm, THD≤10%, efficacy not less than 100 lm/watt, Colour temp 5700 K , CRI ≥ 70, Prower Factor ≥0.95 complete and impact resistance IK07 f complete all as specified and directed by engr-in-charge.
M&L street light bracket made out from GI Pipe 32 mm bore, light grade, 1.2 m long bent to shape including fixing 02 set of clamp made out from MS Flats of size 25x5 mm complete with nuts and bolts and washers of suitable size duly painted with two coats of aluminium paint over a coat of red oxide primer all as specified and directed .
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 25 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
Supply and install hi wall split Type Airconditioner with indoor & outdoor unit complete with Inverter Technology, 3D Airflow, power chill operation,cordless remote control unit and with in built air ioniser, PM 2.5 Filter for better indoor air quality with 5 star rating and EER 3.2 of capacity 2.0 TR with precharged CFC free refrigerant with hot and cold function all as specified and directed by Engr-in-Charge.
Supply and fix Voltage stabilizer ISI Marked automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
M&L for cutting GI pipes 100 mm Dia for insertion of new tees,branches connecton for new branch including any tee and necessary accessories complete all as specified and directed.
M/L valve pit chamber of size 450 X 450 X 450 mm internal dimension , 6mm thick MS steel cover with 2 Nos MS hinger suitable size welded with angle iron frame of 40x40x6mm thick with lifting hooks and locking arrangement complete with necessary earth work, brick work in cm (1:6), 230 mm thick PCC bed (1:4:8) type D-2, 150mm thick, 15mm thick cement plaster in cm 1:4 internal surface complete and external surface of wall up to 300 mm front top and applying a coat of black bituminous paint to the steel surface complete.
M&L for tubing medium grade galvanized with all fitting laid in trenches complete of size 25 mm bore complete all as specified and directed.
All as per Item No 170 Above but 20 mm Bore
M&L for Gun-metal gate valve of size 25 mm with iron wheel head, screwed both ends for iron pipe and fixed.
All as per Item No 172 Above but 20 mm Bore
PANWAR CONSTRUCTIONS
BRIJ CONSTRUCTIONS
DHIMAN ENGINEERS & BUILDERS
RADHA ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .