Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-Finance DHARSHA NEAR MATH P O GOVT OF INDIA PRESS COLONY DIST HOWRAH PIN 711 112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | ₹29.1 L | L1 | Accepted-Finance L1 Bidder |
| 2 | L2₹29.3 LRejected-Finance | ₹29.3 L | L2 | Rejected-Finance Bid is not L1 |
| 3 | L3₹29.4 LRejected-Finance 0 JANAI JANAI CHANDITALA HOOGHLY WEST BENGAL 712304 UDYAM WB 07 0059321 | HOOGHLY | WEST BENGAL | 712304 | ₹29.4 L | L3 | Rejected-Finance Bid is not L1 |
Tender Value
₹28.6 L
EMD Value
₹57,294
Closing Date
21 Jan 2026, 1:00 pmClosed
Executive Engineer PWD Howrah Electrical Division
Onkarmal Jetia Road Howrah 711103
Remodeling and Renovation of Department of Disaster Management and Civil Defence ( Rest of SEOC) at 2nd Floor(204 room to 205 room) , Nabanna, Howrah during the year 2024-25----- Electrical works and SITC of AC Machine.
2025_WBPWD_971219_1
WBPWD/EE/HED/NIT- 36 of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
2nd Floor(204 room to 205 room), Nabanna
Please refer Tender documents.
7 documents required · 7 mandatory
₹57,294
9 Feb 2026
31 Dec 2025
27 Jan 2026
2 Jan 2026
21 Jan 2026
5 Jan 2026
Dismantling the existing DBs, luminaire, wiring, cables, junction box, switch board etc From site and returned the same to store as per direction of E.I.C.(For two locations (Room 204,205) for two days)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex FRLS/ POLYCAB/ RR KABLE) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/ fan/ call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed ] Average run 8 mtr (E 25/4(e)
On Board
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. (E-18/10)
20 mm size
25 mm size
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe 25mm dia, 3mm thick as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. (E-3/7a)
Supplying and laying 20mm dia size PVC Rigid Conduit 'FR' [Precision Make] into the wall with necessary arrangement as per direction of E.I.C. after cutting the wall by companies own tools & tackles and also mending goods the damages[NS]
S & F 100mmx50mm PVC trunking with supply and fixing seperation partition (make: Precision) on wall with screw, washer etc as per direction of E.I.C [NS]
Supply & Fixing of 200x50x1.25mm (18 SWG) perforated GI cable tray with perforation not more than 17.5% suspended from ceiling with 25x25x3mm angle iron support incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required Incl. Al painting of MS support. (D-14, 34 (a))
150mmx 100mmx65mm
200mmx 150mmx65mm
300mm x200mm x65 mm
250mmx 250mmX30mm box with top cover 300mmx 300mm top cover
S & F of 20mm PVC flexible pipe (Make: Precision) as per direction of EIC.
3x1.5 sqmm (FRLS) (group control of lighting, additional Point if required)
2x2.5+1x1.5 sqmm (FRLS) (For Comp. Points (maximum 2 comp board in each circuit), Power Plug (individual circuit for Xerox, microwave oven, Elect Kettle, Toster etc))
2x4+1x2.5 Sq.mm (FRLS) (For Split AC Machine)
2x6+ 1x4 sqmm (FRLS) (For Rising to LSPN DB & CSPN DB- Approx distance 45Mtr)
4x6 sqmm+ 2x4 sqmm (FRLS) (For VTPN to Ductable split AC Timer DB incomer & Timer DB to ODU)(Approx distance from shaft AC VTPN toTimer DB is 75 mtr)
4x10 sqmm +2 x6 sq.mm (FRLS) (For Rising to PBDB Incomer approx distance 45 mtr)]
S & F 220V minimum 36W LED Down light recesses mounted squar fittings with 4 numbers 'L' clamp whose one side fixed on ceiling with MS fastner and the light hang by 4 Nos GI spring. The light having minimum 48000 burning hour,Lumen O/P 100lm/watt,Driver rating should be higher than the fittings rating. (make: Signify / Crompton / Wipro) as per direction of E.I.C. .
S & F 220V minimum 12/15W LED Down light recesses mounted round fittings suitable for 147mm dia round false ceiling cutting (incl cutting the false ceiling) having minimum 48000 burning hour, Lumen O/P 100lm/watt,Driver rating should be higher than the fittings rating. (make: Signify / Crompton / Wipro) as per direction of E.I.C.
Supply & fixing of 6 watt Tiltable round led spot light,Driver rating should be higher than the fittings rating and necessary interconnections including cutting the false ceiling. (Make- Philips/ Comptron).
Supplying & Fixing 1200mm sweep,370 RPM ,single phase,BEE Star rated AC ceiling Fan with blades, canopy, fork, rubberbush etc. incl. S&F connecting wire for down rod upto 30 cm incl.painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire Supply & Fixing complete with all accessories(Make- Orient/ Comptron/Polar as Make & model approved by EIC)
Suppy & Fixing of 450 mm sweep metallic body wall fan by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. The fan must have the feature of- Protection against corrosion with powder-coated guard and polymer ring, Up & down tilt mechanism, Aerodynamic metal blades for high air thrust motor, Pull-cord mechanism for on/off & speed control, Thermal overload protection with auto-reset, Air Delivery 110 (cmm), RPM 1325. Make & Model- Orient, TORNADO WALL-II or its equivalent Comptron
Supply, Delivery & necessary assembling of 450 mm sweep, 1330 RPM, Air delivery 6880 CMM, Power consumption 160 Watt full metal body Pedestal Fan. (Make- Comptron /Orient as Make & model approved by EIC) )
Supply & Fixing of 9"(225mm) exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust fan (Make- EPC /Crompton/ Orient as Make & model approved by EIC)
Supply & Fixing 230 V, 3 nos. 6 A, 3 pin Modular type plug socket with 3 nos. 6A Modular type switch and one no 16 A, 3 pin Modular type plug socket with one nos 16A Modular type switch(Brand approvedby EIC) without plug top on 2 row 12 Module PVC Modular typeswitch board with 2row 12 Module top cover plate flushed inwall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. E-17 /1(e),3(a), 3(b),4(a),4(b)
S&F of 415V, 32A single timer controlled starter for 3 ph ac machine control in SS double door 14-way DB enclosure (L&T/ ABB/ Legrand) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 6Sq.mm PVC insulated copper wire for power & 1.5Sq.mm PVC insulated copper wire for control wiring with dowells solderless socket by crimping method as to GS, earthing attachment on wall icl necessary connections as per direction of EIC:- A) 32A FP MCB, C curve (L&T /ABB/Legrand) -- 1no As incommer B) 24Hr x 7days programmable Digital time Switch (L&T make Cat no 67DDT0) -- 1no C) 40A TPModular Contactor with 230V AC coil, (L&T )-2 Nos D) 25A Auto-Off-Bipass SPDT toggle switch (approved make) - 1 no E) 1 Pole, 6A MCB, 10kA, C curve- Legrand/L&T F) LED ON, OFF indication lamp (approved make) -- 2 No
Supplying & Fixing GI 6 Modular Switch Board complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting andmending good damages to building works incl. Supply & Fixing 2 nos 240 V 16 A modular switch and 2 nos 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) on GI Modular type switchboard having top cover plate and making necessary connections as required.
S & F of 6 Modular GI box on wooden plate along with top cover plate and three number 6A 3pin socket. [E-17/1b, 4a]
S & F of 4Modular GI box on wooden plate along with top cover plate, one separate 5A switch & 5A 3pin socket and one 15A switch. [E-17/2b, 3a, 3b, 4a]
S & F of 230V buzzer type call bell having light indication with attendent reset option into 4modular PVC box and suitable size 3mm bakelite top cover. (Make : Max)
S& F of LED Engage board also provide "U" hooks two nos and dog chain as per direction of E.I.C
Screen Size 32 Inches (Make: SONY BRAVIA 32W830K)
Screen Size 43 Inches (Make: SONY BRAVIA 4K Ultra, KD-43X70L)
SITC of wall mounted Reverse osmosis water purifier unit having purification capacity minimum 20LPH, storage 12 Ltrs, Same GPD rated double (when valuein between 75-100 GPD) membrane filtration or Minimum 150 GPD Single membrane filtration, ABS body, Input supply-170-280 V AC, 50 Hz, Size-L (375-400)mm x D (230-254) mm x H (525-540)mm with all installation accessories, Iron Removal filter. Make- Apyron/wave, equivalent in KENT, Grand plus, Aquguard
Supply & delivery of paper shredder machine having minimum 18 sheet (70 gsm)cutting capacity at a time, 230V AC supply operated, minimum 35 min run time of 18 sheet cutting, min 32ltr waste volume capacity, auto start & stop, thermal protection, one CD cutting capacity. (Make- Kores model easy cut 871/ equivalent in Antiva- as per direction of EIC)
Dismantling existing Two numbers 8.5TR ductable split air conditioning machine & 3 nos 2 TR capacity Split RAC complete with all accessories IDU, ODU, GI ducting, refrigerant pipe lines etc and storing, stacking the same as per direction of EIC
SITC of 415V minimum 8.5TR inverter type ductable split AC machine complete set (indoor and outdoor) having minimum air flow 3390CFM, R410A refrigerent, DC inverter type single/Twin scroll compressor, copper coils at both units i.e, indoor & outdoor, centrifugal type fan motor with speed control, P2 type capacitors, 1.5mtr corded remote. (Make: Carrier/ Hitachi/ Mitsubishi heavy/ O-general/Daikin having same or higher specifications with latest model - as per direction of EIC). Charges of tie rods complete with anchor fastners for indoor unit hangings included. Charges of anti-vibration pad at outdoor unit included. During testing nitrogen flashing and holding included as per direction of EIC.
Copper pipe of 1-1/8" size for Suction line
Copper pipe of 5/8'' size for Liquid line
Supplying & laying of 1.1KV grade 7 core 2.5 Sq.mm flexible copper cable and making necessary connections for ODU to IDU communications (Make-Polycab/ RR/ Finolex)
S & F of ISMC 100x50mm / ISA 50x6 MS section duly welded with 5/6mm thick MS sheet / ISA 50x6 mm / necessary MS section as per direction of EIC. after necessary cutting, grinding, two cote synthetic painting, welding etc as per direction of EIC for base frame of AC machine outdoor unit. Also, S & F of suitable size anchor fastners as required as directed by EIC.
SITC of extra refrigerent R410A as per manufacturer guide line.
SITC of Drain water pipeing work out of UPVC/HDPE pipes of approved make as per IS-1239 (part-I) of 32 mm dia conforming to ASTMD-1785 incl. Fitting accessories, bend,elbows, tees,flanges tapping wall sleeves, hangers, supports, anchors and with nitral rubber insulation with 12.5mm thick nitrile rubber tube insulation. (Mk. HB/ Supreme / Oriplast)
SITC of 9mm thick nitrale rubber insulation with adhesive for indoor unit insulation.
Thickness 0.80 mm(22SWG) sheet
Thickness 0.63 mm(24SWG) sheet
Supplying & fixing of Linear Type powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. (make- System Air/ Air Enterprise/ Carryair)
Supplying, fixing testing commissioning of supply air diffusers of linear type powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supply and fixing of acoustic lining of supply air duct and plenum with 25mm thick resin bonded glass wool having density of 32kg/m³, with 25mm X 25mm GI section of 1.25mm thick, at 600mm centre to centre covered with Reinforced Plastic tissue paper and 0.5mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
S&F Heat Retardant Closed Cell 'Class O',13 mm Single Thick fire Retardant anti microbial type nitrile Rubber Insulation with AL foil faced outside Supply AIR Duct[ make Air Mac cell/K-flex/Accro -flex]
Damper
Charges for dismantling of existing necessary brick walls by skilled persons with companies own tools & tackles only making the route of supply air duct / return air path or duct / fresh air duct. Also removing rubbish as directed within a lead of 75 mtr. This dismantling will be at 2nd floor. (Civil SB (B) Item no. 1(a), 1(b) Page no 10 of 315)
Charges for removing the rubish (which is created due to making of ducting route / return & fresh air route) from site to nearest vat by suitable labour, tools & tackles, vehicle incl fuel and allied necessary items. (Civil SB (B) Item 13 Page 12 of 315)
S & F of fire retardant non porus double layer flexible connection (CANVAS) between each indoor unit & duct as per direction of EIC
Supply & Deliveery of non-inverter type split Air Conditioning machine having cooling capacity not less than 6900 Watt, ISEER 3.8 to 4.39 BEE rating not less than 3 star, Noise level not more than 50 dB. This split Air conditioning machine fitted with rotary compressor, LCD remote & all other accessories. Suitable for refrigerant R32/ R410A. Make- O-General/Daikin/ Hitachi/Mitsubishi Electric/ Mitsubishi Heavy industries as per approved by EIC/ authority
Installation, testing & commissioning of 2 Ton split AC machine incl. supply & fixing required angle iron structure on wall for placing outdoor unit and mending good the damages as per direction of EIC
Supply & Installation of additional Cu refrigerant pipe of 15.88 mm dia for Suction line & 6.35 mm dia for Liquid line with 9mm thick nitrile rubber insulation including saddle, screw, insulation tapes, fastner, tie rods for above AC machine asper direction of EIC
Supplying & laying of 1.1KV grade 4 core 2.5 Sq.mm flexible copper cable and making necessary connections for starter to ODU and ODU to IDU (Make-Polycab/ RR/ Finolex)
Supply & laying 25mm dia UPVC/HDPE pipe & all accessories in wall for drain line with nitrile rubber insulation (MD/ Oriplast/ Supreme) (for 2TR split AC)
ADD: GST @18%
ADD: LWC @1%
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.64 MB
2911.pdf
Tender Documents • 1.86 MB
BOQ_2362457.xls
BOQ • 0.97 MB
Download all tender documents and submit your bid