| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹36.6 LAdmitted-Finance | -17.66% | ₹36.6 L | L1 | Admitted-Finance |
| 2 | L2₹37.7 LAdmitted-Finance | -15.00% | ₹37.7 L | L2 | Admitted-Finance |
| 3 | L3₹38.4 LAdmitted-Finance | -13.52% | ₹38.4 L | L3 | Admitted-Finance |
| 4 | L4₹44.0 LAdmitted-Finance | -1.00% | ₹44.0 L | L4 | Admitted-Finance |
| 5 | L5₹44.4 LAdmitted-Finance | -0.10% | ₹44.4 L | L5 | Admitted-Finance |
Tender Value
₹44.4 L
EMD Value
₹88,820
Closing Date
16 Mar 2026, 3:00 pmClosed
Er Gurjeet singh
XEN PADDAR
REFER TO BOQ
2026_PWDJK_304304_1
e-NIT No. 58 of 2025-26 Dated 23-02-2026
Open Tender
Civil Works
240 days
paddar
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Executive Engineer PWD Division Paddar
₹88,820
27 Mar 2026
23 Feb 2026
16 Mar 2026
23 Feb 2026
16 Mar 2026
23 Feb 2026
Dismantling and reconstruction of wooden work all complete job as per engineer in charge. Skilled Labour(Carpenter)
Dismantling and reconstruction of wooden work all complete job as per engineer in charge. UnSkilled Labour
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead : Of area of 3 sqm. and below
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below
Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:In cement mortar
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:4:8 or leaner mix (i/c equivalent design mix)
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil :
Hand packed stone filling including Cost of stone
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand)
Random Rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) and curing complete at window sills, ceiling level and the like: 7.2.1 Cement mortar 1:6 (1 Cement : 6 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns etc. for mass concrete.
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platforms.
Edges of slabs and breaks in floors and walls Under 20 cm wide
Columns, pillars, piers, abutments, posts and struts.
12mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 coarse sand)
20mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4( 1 cement :4 coarse sand)
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate.
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete First class Budloo/Fir wood
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class kail wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). Second kail wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Grade I, Type II IS : 12823 marked 12 mm thick Coir Veneer Board (conforming to IS: 14842)
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class Kail wood
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete Budloo/ Fir wood 50x12mm
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. . 0.63 mm thick with zinc coating not less than 275 gram/m2
Providing and fixing strips in joints of terrazzo/ cement concrete floors. 11.16.1 Glass strips 40 mm wide and 6 mm thick
Providing and fixing plained eaves boarding. 2nd class kail wood 250x32 mm (nominal size )
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : 9.99.4 100x10 mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : 9.99.3 200x10 mm
Providing and fixing aluminum handles ISI marked anodized (anodic coatingnot less than grade AC 10 as per IS: 1868) transparent or dyed to requiredcolour and shade with necessary screws etc. complete.
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing brass bib cock of approved quality. 15 mm nominal bore
Providing and fixing brass stop cock of approved quality. 15 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work-Exposed on wall 15 mm dia. nominal bore
Providing and fixing PVC soil, waste and vent pipes : 100 mm dia
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
Carriage of material by Mechanical Transport & Head Load including loading / unloading and stacking at site
Sand for an average distance of 35 km by MT & 4 km by Head Load
Stone aggregate below 40 mm nominal size lead upto 85km by MT & 04 km by Head Load
C.G.I sheet/Steel for an average distance of 04 km by Head Load
Cement for an average distance of 04 km by Head Load
Stone for an average distance of 100 mtr by Head Load
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. (Group-A)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 amps & 15/16 amp. modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 3 pin 5/6 amps modular socket outlet and2 no. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25/20 amps modular socket outlet and 25/32 amps 5P MCB, "C" curve including connection painting etc. as reqd. modular switch, connection etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 10sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 16sq. mm + 3 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1 x 1.5 sq. mm
Supplying & fixing of ceiling fan of following sweep 2.25 m mid condenser and 1-6" down rod on the esisting fan hook with necessary connection from celling rose to fan using twin core copper wire (As approved site in charge) 1200mm sweep 3 star
Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type) on wall with necessary connection as reqd.
Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan ceiling rose to fan using 2 core flexible copper wire.225mm/9" sweep exhaust fan
Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan ceiling rose to fan using 2 core flexible copper wire.300mm/12" sweep exhaust fan
Supplying and fixing of fan hook (U hook) on celiling with 4 nos, of anchor fastener on both ends with necessa bolts and nuts and mansonry work as required.
Supplying & fixing following size extra down rod with twin core flexible copper wire for ceiling fan 3'-0"
Making round shaped hole on the wall including supply and fixing of necessary cement concrete collar to suit 300 mm heavy duty exhaust fan and finishing the wall to make good.
Supplying and fixing of 25 mm thick ply wood with round shaping at the center to fix exhaust fan on ventilator with required accessories.
Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 16 way double door
Supplying & fixing of following way horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 4 way (4+12) (Double door)
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cove
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply, installation, testing & commissioning of maintenance free copper earthing system with 2 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make). 25 mm
Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire. IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver, System lumen efficacy ≥ 100 Im/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection,THD <10%, P. F.20.95, CRI >80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends, CCT 3000°K/ 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 20/22 watt LED 4 feet with min. lumen output (2000-2200) lm
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size andCCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ extruded aluminium body (thickness>=1.20 mm)
Providing & fixing of following accessiories
5/6 A 3 pin top
5/6 A 2 pin top
15/16 A 3 pin top
Insulating Tape ( ISI brand)
Ceiling Rose
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A socket
3 pin 5/6 amp socket outlet
6 pin 15/16 socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Single pole upto 32 amp.
Single pole and Nuetral 32 Amp
Double pole
Single pole and neutral 40 amp
Single pole and neutral 63 amp
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as reqd.
SITC of wall/Free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters as per point (a) Thickness of sheet shall not be less than 1.6 mm up compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S, channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door(c)with locking arrangement for equipment/switchgear Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125).(d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)
63 Amp, 25 kA, FP MCCB 1 CU=100% 1CS
Electrical Rubber Mat having thickness 6mm and width 1 mtr
On load change over switch FP 63 amp. (Front operated)
Aluminium Bus Bar 300 amp set of 4 strips 12"
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 25 sq. mm 3.5 core
Supplying and fixing of Ding Dong Bell
Supplying & fixing of Electrical Accessories PVC casing and Caping (Batten)
Casing Caping 1"
Casing & Caping 3/4"
Supplying & Fixing of Phenolic Laminated Sheet 9"x 11" including cutting the space for switches/socket etc.
Supplying & Fixing of Phenolic Laminated Sheet 9"x 6" including cutting the space for switches/socket etc.
Supplying & Fixing of Phenolic Laminated Sheet 4"x 4" including cutting the space for switches/socket etc.
Supplying & Fixing of Phenolic Laminated Sheet 11"x13" including cutting the space for switches/socket etc.
Supplying & Fixing of Phenolic Laminated Sheet 6"x 3" including cutting the space for switches/socket etc.
4" Deep box
5" fan box
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
BOQ_988446.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid