Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹1.4 Cr+₹4.9 L (3.67%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | ₹1.4 Cr+₹4.9 L (3.67%) | L2 | Rejected-Finance BEING NOT LOWEST TENDER |
| 3 | L3₹1.4 Cr+₹5.7 L (4.22%)Rejected-Finance NO 2 16 KANGAYAMPALAYAM SULFUR PO COIMBATORE 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | ₹1.4 Cr+₹5.7 L (4.22%) | L3 | Rejected-Finance BEING NOT LOWEST TENDER |
| 4 | L4₹1.4 Cr+₹7.3 L (5.45%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | ₹1.4 Cr+₹7.3 L (5.45%) | L4 | Rejected-Finance BEING NOT LOWEST TENDER |
| 5 | L5₹1.4 Cr+₹8.7 L (6.50%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | ₹1.4 Cr+₹8.7 L (6.50%) | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
13 Aug 2021, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT TO DAMAGED ROOF FACIA PROJECTION OF BLDGS ROOF TREATMENT BROKEN JOINERY PAINTING AND OTHER B AND R WORKS INCLUDING CERTAIN MISC E AND M REPAIR WORKS AT AF STN SULUR
2021_MES_460948_1
8425/E8
Open Tender
Miscellaneous Works
Item Rate
304 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹2.2 L
Yes
20 Aug 2021
17 Jul 2021
14 Aug 2021
17 Jul 2021
13 Aug 2021
7 Aug 2021
17 Jul 2021 - 6 Aug 2021
Amount
SCHEDULE A BOQ
Dismantling/ racking the existing old unserviceable cement plaster and loose/unsound weaken cement concrete of any description and in any position from existing external/internal surfaces of wall, roof, chajja etc complete all as specified and as directed.
M&L repairs to cracks of any description,less than 5mm size by opening up cracks in V-groove manner approximately 6mm x 6mm size using mechanical cutter,cleaning the groove properly to remove loose particles, dust etc, sprinkling with clean water and filling with single component entitious crack filler using readymix powder of cementitious ingredients having compressive strength of 14 N/ mm² after 7 days of Make M/s STP Limited, M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex complete all as specified and as directed.
M&L repair/rehabilitation works to damaged structure by drilling hole in RCC/Bricks structures using drilling machine up to a depth of 15 mm and 18 mm dia, removing dust, etc by vacuum cleaner and blowers, providing and fixing of heavy grade GI pipe nipple 15 mm dia, 75 mm long, @ 1.0 mtr c/c in both direction and injecting cement slurry mixed with Acrylic emulsion based concrete bonding agent cum cement modifier and cementitious based plasticized expanding grout @ 1.00Kg/50kg of cement bag through nipple and closing ends nipple epoxy putty/silica jelly after injecting the chemicals mixed with cement slurry complete all as specified and directed complete all as specified and directed by Engineer-in-Charge. Make: STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex.
M&L preparation of external wall surfaces,affected with seepage by applying acrylic elastomeric exterior waterproofing coating, liquid base,applied highly durable waterproof coating system with high quality acrylic emulsion, functional filler, sunlight stable pigment and quality fungicides to have seepage free wall complete all as specified and as directed. Note:-(i) The above treatment shall have properties that provide features like crack bridging ability, breathability, flexibility & exterior durability and resists micro-organism growth. (ii) The above treatment shall cover hairline cracks up to 0.5 mm effectively and shall have excellent crack bridging ability and shall bridge cracks up to 2 mm width. (iii) The elongation at break is approx. 200 %. The tensile strength is 0.72 Mpa. and has a hardness shore ‘A’ scale of 72, with an adhesion strength of 1.5 Mpa. (iv) The coating is UV resistant, algae and fungus resistant, and a crack bridging ability of 1-2 mm and the coating must be applied with temperature above 5°C and below 45°C. (v) The coating shall be applied in two coats of by roller or brush application at the interval of 4-6 hours.Allow applied coating to dry or cure for 7 days. (vi) Make of acrylic waterproofing coating: Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex .
M&L repairs to leakaged roof by applying 15-20mm screed with single component cement based Polymer modified fibre reinforced mortar and shall achieve a compressive strength of 15 MPa in 7day & 50 MPa in 28 days and a flexural strength of 7 MPa @ 7 days complete and finished the roof properly to match with existing using cement and sand mortar complete all as specified and as directed. Note:- The treatment shall compensate both plastic and hardened shrinkage and have minimum direct adhesive bond strength of greater than 2 MPa., including alkaline, compatible with host concrete with similar thermal properties and shall achieve a elastic modulus of minimum 25 KN/Sqmm. Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex .
M & L for water proofing treatment to existing damaged roof by curing of the surface using low viscosity emulsion @ 250gms/Sqm with daylight Reflectance of 70% as per ASTM E-1347 and to have a special alkali reactive emulsion breaking system and non-penetrating continuous film complies with the internationally recognized ASTM C309 standards including all tools and tackles complete all as specified and as directed by Engineer-in-Charge. Make :STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex .
M&L for protection screed 10 mm thick using CM (1:4) over treated surface admixed with Acrylic emulsion based cement modifier of Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex complete all as specified and as directed.
M&L for dismantling/taking down old existing unserviceable cement plaster loose/unsound weaken cement concrete of any description and in any position from existing surfaces with an average depth 15 mm with power driven of pneumetic chisel and removed the debris outside MOD land with a distance exc 1.5 KM and not exc 5.0 KM including cutting of all edges,making square shoulders of the cavities,roughening the smooth surfaces, scrapping out/removing corrosion all loose/scale/rust etc from the visible reinforcement by applying one part alkaline based rust remover, with corrosion inhibitors and dispersing agents having specific gravity of 1.18 and cleaning the steel reinforcement properly complete all specified and directed by engineer-in-charge. Make :STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex .
M&L for treatment to cracks in joints by applying epoxy bonding agent for proper bonding between old surface with micro-concrete/new surface and fixing shuttering around the structural members duly retrofitted complete all as specified and directed. Note:- (i) The bonding agent shall be a two component solvent free epoxy supplied as ready to use at site. (ii) The product shall have a minimum pot life of 30 Min at 35°C and an open time of atleast 30 Min @ 30°C up to which new concrete can be poured. (iii) It should develop a minimum compressive strength of 65 N/mm2 and a bond Strength of 3 MPa. Make of epoxy bonding agent of Make : STP Limited,M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex .
M&L form work to sides and soffits of lintels, beams, columns, shelves, chajjas including overhangs etc for fair finished flat surface, complete all as specified and directed by Engr-in-charge
M&L in repairs TMT bars 8mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9mm dia complete all as specified and directed by the Engineer-in-Charge
Removing existing water proofing treatment and expose top surface of RCC slab and removing rubbish outside MD area clean the roof surface with wire brush and water and applying two coats of 1mm thickness waterproofing and protective coating on walls and floors ,etc complete all as specified and directed. Note:- The waterproofing system should comply with ASTM C836, ASTM D6083, ASTM D4541 having Hardness Shore 'A' scale of 50.Adhesion to substrate 0.4 Mpa,tensile strength(ASTM D412) 1.4 MPa Make : STP Ltd or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex.
M&L for water proofing treatment by applying single component cement based free flowing grout with 10 mm washed aggregates with non shrink property and a positive expansion of up to min 1 % in the plastic state to achive a compressive strength of 100 kg/Sqcm in 7 day & 500 Kg/Sqcm in 28 days complete all as specified and directed. Note:(i) It shall not bleed or segregate,having a minimum pot life of 20 minutes after which the expansion starts.(ii) It shall be chloride free and creep resistant with epoxy bonding agent having mix density of 1.10 kg/ltr,compressive strength 65 N/mm2 at 7 days bond strength 3 MPa at 7 days having an overlay time of 3 min at 30°C.(iii) pouring cementitious grout into the formwork using suitable arrangement or if required using pumping device for and the bottom shuttering after 7 days ensuring proper bond between the cementitious grout and existing concrete substrata etc including all tools and tackles as per accepting officer,complete all specified and directed by eng-in charge Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex .
M&L for water proofing treatment by applying anti-yellowing coating on wall of liquid state, applied highly durable waterproof coating system for wall, based on high quality acrylic emulsion, functional filler, sunlight stable pigment and quality fungicides complete all as specified and as directed. Note:- (i) It shall have properties that provide features like crack bridging ability, breathability, flexibility & exterior durability and resists micro-organism growth.(ii) It shall cover hairline cracks up to 0.5 mm effectively. (iii) It shall have excellent crack bridging ability and shall bridge cracks up to 2 mm width. (iv)The elongation at break is approx. 200 % and the tensile strength is 0.72 Mpa. (v) It has a hardness shore ‘A’ scale of 72, with an adhesion strength of 1.5 Mpa. (vi)The coating is UV resistant, algae and fungus resistant and a crack bridging ability of 1-2 mm. (vii) The coating must be applied with temperature above 5°C and below 45°C. (viii) The coating shall be applied in two coats of by roller or brush application at the interval of 4-6 hours.(ix) Allow applied coating to dry or cure for 7 days. Make : STP Ltd or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
Note :- The work (item No 2 to 16 of BOQ) shall be carried out through authorized and qualified applicators of the any following manufacturer only. MOU to be submitted before commencement of work. Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex .
(a) A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified.
(b) Providing, fixing and erecting scaffolding in double face structure, as required along with approach system for the repairs / plastering of the buildings to facilitate execution of all items of works,complete with necessary support, propping system etc for external repair. The unit rate is deemed to be included this provision also.
(c) The unit quoted rated deemed to included for removing plant/ up rooting of vegetation growth including roots on wall/ roof/ parapet near pipe etc.
(d) The unit quoted rate deemed to be included for necessary safety equipments such as safety belt, ropes, helmets, netting etc mandatorily to be provided to labour working at height exceeding 3 mtr.
M&L Treatment of the sunken floor slab comprises of the following specification and all as specified Make :- Dr Fixit/ M/s Sika india Pvt Ltd/ STP Ltd/ M/s Fosroc Chemicals
(a) Demolition of cement concrete filling of any description in sunken portion in toilet and removing debris outside MD land.
(b) Cleaning the sunken/ lowered portion of RCC slab surfaces (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper sploe including cutting holes in bricks or RCC wall for spout (WPC shall be measured and paid separately)
(c) Rendering of uneven surfaces with 10mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured and paid separately).
(d) All junctions points of side wall where CI/ GI pipes are passing through shall be sealed with epoxy putty.
(e) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
(f) M&L for applying two coats of polymer modified cementious water proof coating as per manufactures instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed (This item shall be pleasured and paid separately)
(g) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturers specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately).
(h) M&L PCC 1:5:10 type E2, complete all as specified
(j) M&L PCC 1:2:4 type B0 12.5mm thick, complete all as specified
Note :- Test the water proof area (ponding test) by filling water for at least 72 hours and tested for leakage, seepage to the entire satisfaction of GE. Test shall be done in presence of reps of Engineer-in-Charge. The treatment shall be carried out by authorised applicator of chemicals. Cost of testing is included in the unit quoted rate above.
Supply Only integral water proofing compound complete all as specified and as directed. Make:-Dr. Fixit Pidi Proof and equivalent.
Note for item No 34 :- The work shall be carried out by authorised and qualified applicators of the above mentioned manufacturer.
PVC (SWR) pipes single socketed in any length with rubber ring joints of 110 mm bore fixed to wall including taken down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) 110mm junction (single T) equal or unequal provided with access door including taken down existing one
PVC (SWR) 110mm junction vent cowl all as specifed including taken down existing one complete all as specified and as directed by Engineer-in-Charge
PVC bends 110mm bore including taking down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) pipes single socketed in any length with rubber ring joints of 75 mm bore fixed to wall including taking down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) 75mm junction (single T) equal or unequal provided with access door including taken down existing one
PVC (SWR) 75 mm junction vent cowl all as specifed including taken down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) branch piece (single Y) 75mm equal or unequal provided with access door including taking down existing one complete all as specified and as directed by Engineer-in-Charge
PVC bends 75mm bore including taken down existing one complete all as specified and as directed by Engineer-in-Charge
Vitreous china squatting pan 'Orissa' Pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe ) including provision of lime concrete bedding fixed including taking existing one complete as directed by Engr-in-charge.
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and Joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile of size exc 0.09 Sqm but n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incuding screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) complete all as directed
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and Material and labour for Glazed ceramic coloured tiles 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado/ skirting including 10mm thick 1:3 backing coat complete all as specified and directed.
Note for item No 46 & 47 :- The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
Dismantling/taking down old existing damaged cement plaster, loose/ unsound weaken cement concrete of any description and in any position from external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facias for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface, scrapping out/removing corrosion all loose/scale/rust etc from the visible reinforcement by applying. Geopolymer based Geo Krete-VR of Make eco materials or equivalent in FOSROC chemicals/ Tiki Tar/ M/s STP limited (as approved by GE) over the existing damaged surface including mixing mortar with recommended water cement ratio and levelled the surface to match with existing surface all as per manufacturer's instructions as specified and directed. Note:-The geo polymer based water impermeable ceiling and vertical surface repair mortar shall have compressive strength of 10 Mpa in 3 hours and 35 Mpa in 28 days without any water curing and curing compounds having a water penetration of less than 3mm when tested as per DIN 1048 and RCPT value of less than 900 coloumbs when tested as per ASTM C 1202.
Note for item No 49 :- The tenderer shall take into consideration the following points while quote rate for the above item :-
(a) Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing unserviceable materials outside MD land and leaving the work clear of any plastering or Racking out joint/pointing to stone masonry, coursed or uncoursed in wall complete all as specified and directed. The unit rate is deemed to be included this provision also.
(b) Surface preparation such as creating mechanical key like roughning the surface by scrubbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure up-to 500 to remove the dirt, dust, loose particles, wax, efforencence and other contaminations from the surface of RCC columns/beams/slabs/ facia/any brick/stone surfaces etc all as manufactures and all as specified and directed by Engineer-in-Charge. The unit rate is deemed to be included.
(c) Providing, fixing and erecting scaffolding in double face structure, as required along with approach system for the repairs / plastering of the buildings to facilitate execution of all items of works,complete with necessary support, propping system etc for external repair. The unit rate is deemed to be included this provision also.
(d) Material shall be procured from the authorised manufacturer only.
(e) The work shall be carried out through authorised and qualified applicators of the manufacturer only.
M&L Preparation of plastered or un plastered old surfaces of walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots etc and applying one coat of cement based paint complete all as specified and directed.
Preparation of old decorated plastered or unplastered surface of wall, chajja, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed.
Preparation of old plastered surfaces of wall by using pressure washer, removal all dirt and dust and applying one coat of exterior emulsion weater proof paint complete all as specified and as directed.
Preparation of old decorated existing external surfaces of walls and providing one coat of acrylic washable distemper complete all as specified.
Taking down shutters of any description exc 1.0 Sq.m and n.exc 2.0 Sq.m each complete all as specified and directed.
Taking down chowkhat or frame(wooden/steel) not exceeding 1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down chowkhat or frame(wooden/steel) exceeding 1.50 Sqm not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Resecuring without taking down chowkhats or frames but with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and as directed.
Resecuring without taking down chowkhats or frames but with shutters (without taking off shutters from the frames) exc 1.5 sqm but n exc 4 sqm each complete all as specified and as directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified .
Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified.
Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Cutting holes in stone wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts/lugs and making good dismantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete as required complete all as specified and as directed.
MS work (flat iron) 25mm x 3mm thick) in small articles such as hold fast and similar small articles conforming to Fe 290 Gde E-165 including taking down existing one complete all as directed.
150 mm long aluminium, anodised, barrel tower bolts of extruded section including taking down existing one complete all as specified and directed
125 mm long aluminium, anodised, barrel tower bolts of extruded section including taking down existing one complete all as specified and directed
Supply and fixing Butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed.
Supply and fixing in repairs butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed.
Supply and fixing 100 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Flush shutters,30mm thick, solid core construction, with particle board core and ply wood face panels, commercial type on both sides, complete all as specified and directed.
30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); all as specified and directed.
Supply and fixing Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete all as specified and as directed.
Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete including taking down existing one all as specified and as directed.
M&L 2nd class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles not exceeding 200 cu. cm each dismantling all as specified & directed.
S&F in repair Stainless Steel Door Magic Eye with Flap to wooden doors , unique design any type complete all as specified and directed
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete including taking down existing one all as specified and directed.
Preparation of new wood or wooden surface of any description not othrwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Supply and fixing 250mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminum alloy and fixed complete all as specified and as directed.
Easing of door shutters for easy closing/opening and tightening of hinges or changing the position of hinges, adjustment of tower bolts, sliding bolts with new screws etc, Size of door upto 2 Sqm complete all as specified and directed by Engineer-in-Charge.
Easing of window shutters, kitchen cupboard shutters, show case shutter drawers including fixing of screws adjusting handles, knobs tightening piano hinges including misc small adjustments , size of window upto 1.5 Sqm. complete all as specified and directed by Engineer-in-Charge
5mm thick rubber beading strips of entrance doors having width exc 3CM to not exc 5CM to arrest entry insects including taking down existing one complete all as specified and as directed
M&L Factory made UPVC three track sliding Window frame having 2 tracks for glass shutter and 1 track for mosquito sash made of upvc profile section of size 73mm x 42mm (wxh) having outer wall thickness of 2.0mm(+/-0.2mm). Sliding glass shutter shall be made of UPVC section of size 55mm x 33mm and sliding wire mesh shutter shall be made of UPVC section of size 40mm x 22mm. All section of the frame, sash, transom & mullion, as applicable, shall be duly reinforced with G/J/U/O shape galvanised mild steel section of required thickness considering structural / wind load requirement. System shall be provided with the suitable upvc bead for glazing of the system & fitted with inner & outer EPDM seal gaskets. Clear Glass of Saint Gobain / Modiguard make with thickness of 4mm and stainless steel wire cloth of 0.19mm nominal dia. All welded joints are to be neatly trimmed & feature grooved/raised nib finish so make the finished product free from all sharp edges & burrs. All the corner / mullion / transom joints of the frame and sash shall be mitered cut & fusion welded without any mechanical joining. System shall have adequate drainage mechanism to permit the escape of water from horizontal member beneath each sealed unit. System is to be provided with proper operating & locking hardware mechanism. Window locking system will be either both side push lock system or semi-circle locking system in centre. Complete window shall be fixed in to the existing pre finished aperture, by drilling and fixing through the outer frame using quality fasteners & silicon glue is applied to fill up the crevice between wall and window frame for leak proof installation including taking existing one complete all as specified. Note: - The contractor shall submit 5 years warranty certificate for upvc profile and 1 year warranty certificate for hardwares.
Factory made UPVC Ventilators design will be like top part fixed with exhaust fan provision and bottom part with fixed louver strips.Ventilators frame made of upvc profile section of size 45mm x 43mm (wxh) having outer wall thickness of 2.0mm(+/-0.2mm). Wherever required /specified, system shall havev the fix mullion of size 45mm x 60mm having outer wall thickness of 2.0mm(+/- 0.2mm). All section of the frame,transom & mullion shall be duly reinforced with G/J/U/O shape galvanised mild steel section of required thickness considering structural / wind load requirement. System shall be provided with the suitable upvc bead for glazing of the system & fitted with inner & outer EPDM seal gaskets. Pinhead Glass with thickness of 4mm required for fixed & louvers strips. All welded joints are to be neatly trimmed & feature grooved/raised nib finish so make the finished product free from all sharp edges & burrs. All the corner / mullion / transom joints of the frame shall be mitered cut & fusion welded without any mechanical joining. System shall have adequate drainage mechanism to permit the escape of water from horizontal member beneath each sealed unit. System is to be provided with proper operating & locking hardware mechanism. Complete ventilator shall be fixed in to the existing pre finished aperture, by drilling and fixing through the outer frame using quality fasteners & silicon glue is applied to fill up the crevice between wall and ventilator frame for leak proof installation including taking existing one complete all as specified. Note :- The contractor will have to submit 5 years warranty certificate for upvc profile and 1 year warranty certificate for hardwares.
Applying silicon sealent on joints of wall,cill jambs roof etc complete all as specified as directed
S&F Framed work such as grills , grating ,etc with ends of bars shouldered and or revated for forged in to spike, framed guard bars barred iron doors, ladders, balusters, walk ways raling framed work for water tanks similar work confirming to Fe -290 Gde E-165 including dismantling existing complete all as specified and as directed.
M&L preparation of new steel surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L Preparation of old painted surfaces of steel over 10 cm width or girth, not other wise described and applying one coat of synthetic enamel paint using mechanical means complete all as specified and as directed.
M&L Preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint using mechanical means complete all as specified and directed.
Note for item No 93 to 95 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
M&L Minor repair to aluminum/glass doors, windows, partitions and making the same fully functional (i.e. Handles, hinges, rubber beadings, clips, rollers etc) including repairing/ cleaning/ greasing etc complete all as specified and directed.
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, fixed in repair to wooden frame/welded to metal frame
Supply and fixing in repair aluminium anodized hasp and staples safety type with mild steel hinge pin incl bolt to hinge plate fixed with screws of 100mm length complete all as specified and as directed.
Supply and fixing 150 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed.
200mm extruded aluminum alloy handles, fabricated type, anodised including taking down existing one complete all as specified and as directed.
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm each pane complete all as specified and directed.
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 sqm each pane complete all as specified and directed.
M&L Figured glass, pinhead type 3 mm thickwith oil putty in squares not exceeding 0.5 Sq. m in each pane, with beads, complete dismantling all as specified & directed complete all as specified and as directed.
Refixing of shutters of any description n.exc 1.0 sqm each, in same opening including taking down, petty repairs etc complete all as specified and directed.
Refixing of shutters of any description exc 1.0 sqm but not exc 2.0 sqm each, in same opening including taking down, petty repairs etc complete all as specified and directed.
M&L Factory made UPVC casement door frame made of UPVC profile section of size 60mm x 58mm (wxh) having outer wall thickness of 2.0mm(+/-0.2mm) and 3 box multi chamber construction.The shutter of outward openable door shall be made of size 78 x 60mm (shutter of inward openable door shall be made of size 71 x 60mm) having outer wall thickness of 2mm(+/-0.mm). Doors will have 6mm thick partical board . Wherever required/specified, system shall have the fix mullion of size 72mm x 60mm having outer wall thickness of 2.00mm(+/- 0.02mm) . All sections of the frame ,saash,transom , & mulion shll be duly reinforced with G/J/U/O shpe galvanised mild steel section of required thickness considering structural / wind load requirement. All the corners/mullion / transom joints of the frame & sash shall be mitred cut & fusion welded without any mechanical joining. All welded joints are to be neatly trimmed and feature grooved/raised nib finish so as to make the finish product free from all sharp edges and burrs. System shall have adequate drainage mechanism to permit the escape of water from horizontal meber beneath each sealed unit.System shall be provided with the suitable UPVC beads for glazing of the system with specified/required single /IGU Glass, duly cut at correct degree & fitted with K & O type inner and outer EPDM weather seal gaskets . System is to be provided with proper operating and locking hardware mechanism as per system. Complete door shall be fixed in to the existing pre finished aperture, by drilling and fixing through the outer frame using high quality fastners & silicon glue is applied to fill up the crevice between wall and door frame for lek proof installation including taking existing one complete all as specified. Location- OMQ. Note : The contractor will have to submit 5 years warranty certificate for upvc profile and 1 year warranty certificate for hardwares.
M&L Providing and fixing Gypsum Board 12mm thick in ceiling fixed on Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section,not exc 1.2 m c/c of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. The Gypsum board ceiling shall be treated with two coats of Oil bound distemper over one coat of 3mm thick putty complete all as specified and directed.
M&L Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , treading, oil, greasy spots and applying one coat oil bound distemper complete all as specified and as directed.
Preparation of old plastered or unplastered surface of ceiling brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spotsand applying one coat of white wash complete all as specified and directed.
M&L Preparation of old plastered surfaces of wall by using pressure washer, including removal of existing colour/treatment and dirt, dust etc and applying two coats of exterior emulsion paint complete all as specified and as directed.
M&L Preparation of old decorated surfaces of walls by using pressure washer, remove existing colour/treatment and dirt, dust etc ,applying one coat of wall care putty and then apply two coat of oil bound distemper of required shade over one complete all as specified and as directed by Engineer - in - Charge.
M&L preparation of surfaces and applying reflective paint for Writing letters or figures (Block,Roman,Italic or Indian) n. exc 30 CM high complete all as specified and as directed.
M&L preparation of surfaces and applying reflective paint for Stop, commas, short lines, dashes, hyphens, brackets etc complete all as specified and as directed.
M&L Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds, mass, efflorescent , treading, oil, greasy spots including removal of existing colour/treatment, dirt, dust etc and applying two coats oil bound distemper complete all as specified and as directed.
M&L Bullnosed chequered cement concrete tiles 30cm x 30cm x 25mm thick machine pressed set jointed and pointed in neat cement slurry as in treads and cut and polished using grey cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor fnishes in cement mortar (1:4) including taking down existing tiles complete all as specified and as directed by Engineer-in Charge. Note :- The manufacturer's test certificate of tiles must be submitted for approval by the concered authority.
M&L Chequered cement concrete tiles machine pressed set jointed and pointed in neat cement slurry on vertical surfaces as in skirting, dados and risers of steps and cut and polished using grey cement and pigments over back coat of mortar 10mm thick for laying floor fnishes in cement mortar (1:3) including taking down existing tiles complete all as specified and as directed by Engineer-in Charge.
S&F in repairs Aluminium Composite panel cladding for wall clading and Mild steel column post casing, Wall cladding with 4mm thick aluminium composite panel (colour as approved by GE) fixed with aluminium frame using extruded aluminium section of size 50mm x 25mm x 2mm thick fixed with cleats,fasteners etc , gap will be sealed with silicon sealant appropriate grade complete all as specified and as directed
Note for item No 126 :- a) Providing and fixing Aluminium Composite panel cladding including framing as per the elevation, section and the plan fabricated out of heavy duty Aluminium extruded profiles conforming to alloy 643900 WP with chemical composition and mechanical properties as per IS-733 and as per specifications.
b) The contractor must design the cladding as per the prevalent site conditions and building elevations profiles. No extra claims shall be entertained at any stage for aluminium profile/ wall thickness and size dimensions. The Contractor must quote rates accordingly.
c) The anchoring / bracing of the wall cladding to the RCC beams/ columns shall be done with non-corrosive galvanized brackets of approved design, (Galvanizing to be done conforming to IS 4759-1996 up to 610 gms. Per Sq. M. (80- 90 micron thickness).
d) The framework shall be aligned for the entire height of each Mullion and of the entire width of each Transform by laser beam equipment to ensure 100 percent „X‟ axis and „Y‟ axis alignment.
e) The system should also provide for pressure equalization. The details for pressure equalization to be submitted by the contractor and got approved by the Engineer-in-Charge.
f) EPDM Gaskets of suitable profiles (to accommodate shall be provided including the labour element for fixing in appropriate locations is to be included in the rate).
g) The Periphery of the framework shall be sealed both from inside and outside with silicon weather sealant to make the cladding watertight.
h) Cost of Aluminium composite panel consisting of a core of polyethylene sandwiched between two aluminium skins of 0.5mm thickness with a mild edge. 4 mm total thickness with surface finish of PVDF coating as approved by the Engineer-in-Charge, as shown in the elevation, plan and cross section drawings along with labour element for cutting stacking, carrying to heights and fixing to appropriate locations is included in the rates.
j) All the vertical and horizontal section grooves are to be sealed non staining silicon sealant of make as specified in the list of approved make to make the entire system synchronies with the basic structural glazing/curtain wall structure and also make the system air tight and watertight. The fixing details should be got approved by the Engineer- in-charge. The peel off foil should be removed at the time of handing over as may be required by the Engineer-in-charge.
k) ACP shall be as approved with high fiber filled sandwiched panel 4mm install on Aluminium framing and Galvanised brackets. Aluminium cladding panel to be PVDF fluorocarbon coated factory applied colours. Reverse side to be in mill finish. All the joints shall be sealed with silicon sealant of approved make. The colour of sealant to be decided by Engineer-in-Charge.
l) A sample of panels and installation methods to be submitted to the Engineer in-Charge for approval.
S&F False ceiling at any height with "Armstrong Ultima micro look tiles" manufactured by M/S Armstrong world industries using hot dipped galvanised steel section exposed surface chemically cleaned capping prefinished inbaked polyster paint, main tee of size 3000x32x15mm at 1200c/c and cross tee of size 1200x32x600 at 600mm c/c and wall angle of size3000x19x19mm around the wall to form grid of size 600*600 mm centre to centre.Hanger ofGI wire of 4.0mm dia to be fixed by approved roof plug' level adjusters and screws etc, The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall. Perimeter wall angle and micro look grid runner has to be on the 600x600mm mould including taking down of existing ceiling board of description complete all as directed. Make Armstrong or equivalent make as per list of makes
S&F 6mm thick frame less bevelled edge mirror fixed with steel stud Including taking down existing one complete all as specified and as directed by Engineer-in-Charge.
Plate rack of size 65 cm x 96 cm made of stainless steel fixed in repairs complete all as specified.
Supply & fixed in repair of 12 mm thick ,7 ply, plywood ,grade BWR ,type BB fixed to wooden frame work in wall with nails including taking down all as specified
Supply & fixed in repairs of 18mm thick, 7 ply, plywood, grade BWR, type BB fixed to wooden frame work in wall with nails including taking down all as specified.
Decorative laminates of 0.90 mm thick type matt finish, colour and pattern as approved. Including taken down existing one complete all as specified and as directed by Engneer-in-Charge
Stainless steel handles of size 150 mm of approved pattern and make suitable for Base/Wall unit of modular kitchen Including taking down the existing one complete (Make : Spykar or equivalent make as per list of makes)
Stainless steel plain basket of size 530 x 505 x 100mm Including taking down the existing one complete. Make : Butterfly or equivalent make as per list of makes
Stainless steel thali basket of size 600x 500x 100mm Including taking down the existing one complete Make : Butterfly or equivalent make as per list of makes in PS)
Stainless steel telescopic slider of 500 mm of approved pattern and make suitable for drawer in base unit of modular kitchen including taking down the existing one complete all as specified.
Stainless steel spring hinges of size of approved pattern and make suitable for base/wall unit of modular kitchen Including taking down the existing one complete (Make : BIR SS or equivalent make as per list of makes)
Stainless steel cutlery basket of size 530 x 505 x 100 mm Including taking down the existing one complete Make : Butterfly or equivalent make as per list of makes in PS)
Stainless steel bottle basket of size 200x 508x 431mm including taking down complete all as specified and directed. Make : Butterfly or equivalent make as per list of makes
M&L in repairs granite 18 to 20mm thick (table rubbed and polished) in steps,Jamps, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed. Note : (a) The Unit rate quoted is included for Demolition of Stone Slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar (b) The unit rate is deemed to be included for rounding to edges of stone slabs.
Sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm in repairs all as specified and directed. Make : M/s Diamond / Nirali / Amco / TATA.
Taking down the existing locking system, contains any number of levers repalcing the strucked/damaged levers, applying oil to all parts and making functional properly and refixed in position complete all as specifed and as directed
Supply and Fixing in repairs of brass 4 lever cupboards locks grade I size 65 mm complete all as specified and as directed.
Supply and Fixing brass 4 lever cupboards locks grade I size 65 mm complete all as specified and as directed.
Second class hard wood plain fillets square or rectangular in section exc 3 Sqcm n.exc 6 Sqcm wrought secure with screws complete including taking down all as specified and as directed.
6 mm thick teak wood lipping for 18/19 mm thick particle board fixing with nails complete including taking down all as specified and as directed.
18/19mm thick Prelaminated particle board, interior Grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work including taking down complete all as specified and as directed.
40 mm dia cupboard knobs fixed with nut, screw and washer of brass polished complete including taking down existing one all as specified and as directed.
40 mm dia cupboard knobs fixed with nut, screw and washer of brass polished complete all as specified and as directed.
Continuous (piano) hinges, stainless steel bright finish or electrogalvanised of 40mm width of flaps (when open) complete including taking down all as specified and as directed.
Magnetic catches with 8mm dia steel ball and brass body and striking plate including taking down in complete all as specified and directed.
Stainless steel sink 1.00mm thick for kitchen or laboratory with plug washers waste pipe including fixing cantilever brackets connection union to pipe etc, overall size 495mmx420mm with bowl size 410mmx 330mmx160mm excluding waste coupling waste pipe including taking down existing one complete all as specified and directed. Make:-NIRALI / BLUE STAR /TATA
Waste coupling of CP 40 mm dia with discharge pipe (half or full threaded ) suitable for sink complete all as specified incl taking down and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 including taking down existing tile and removing rubbish off the premises complete all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in skirting/dado. etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:3 including taking down existing tile and removing rubbish off the premises complete all as specified and as directed.
Note for item No 165 & 166 : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate for tiles must be submitted for approval by the concerned authority.
S&F 12 mm toughened glass in shelves 1st quality of approved manufactures with edges round of supported on aluminium anodised angle frame with CP brackets and guard rail fixed with 40 mm long screw rawl plugs etc including cutting notching screwing to wall etc including taking down existing one complete all as specified and as directed by Engr-in-Charge (Make : Saint Gobin/ESG/Modi)
M&L Water proofing treatment of existing roofs as per details given below after complete removal of existing water proofing treatment and expose of top surface of RCC slab of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with water and using wire brush including removing debris to outside the MOD land complete all as specified and as directed :-
(a) Dismantling existing cement concrete/ roof tiles on roof including removing debris to outside MOD land as directed.
(b) Bring upto the slope by providing filling of light weight materials such as cinder, light weight concrete etc as required & then providing PCC 1:2:4 type B1 using 20mm graded stone aggregates of average thickness of 50 mm.
(c) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound as per manufacturer’s instructions.
(d) Surface should be free from any loose paint, dust or grease. Remove all existing bitumen coatings completely by using intense wire brushing, high speed water jet & vacuum cleaner for thorough cleaning of the surface to avoid ‘Peeling off’ problems.
(e) All cracks at corner joints, channels and parapets should be properly treated. For filling cracks upto 3mm crack seal material of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical to be used. Bigger cracks, damaged portions & hollow areas must be repaired with polymer modified cement mortar.
(f) Apply a coat of self priming smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical with 33% dilution with water using brush/roller on newly plastered surface after curing as per IS-456 and allow to dry for 4 to 6 hours (dilution & forced coverage requirement strictly as per manufacturer’s instructions).
(g) After the primed surface has dried, apply first coat of water proofing smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical using brush/roller on the same primed surface & allow to dry for 4 to 6 hours.
(h) Prepare for apply 2nd coat of water proofing smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical using brush/roller on the same surface. The temp to be maintained 25 to 35° C through out the all above application work.
(j) In case of severe dampness an additional coat of damp proof materials to be applied.
Note for item No 169 to 178 :- (i) The work shall be carried out through authorized and qualified applicators of the following manufacturers only. MOU to be submitted before commencement of work. Make : M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical
(ii) Material shall be procured from the authorised manufacturer only.
(iii) A performance guarantee certificate for 10 years shall be submitted by the contractor to the GE on completion of work as specified.
(iv) The unit quoted rate is deemed to include taking down of water pipeline, tanks, wires (etc) found on roof and refix at the original position after complete treatment of roof.
(v) Providing, fixing and erecting scaffolding in double face structure, as required along with approach system for the repairs / plastering of the buildings to facilitate execution of all items of works,complete with necessary support, propping system etc for external repair. The unit rate is deemed to be included this provision also.
(vi) The unit quoted rated deemed to included for removing plant/ up rooting of vegetation growth including roots on wall/ roof/ parapet near pipe etc.
(vi) The unit quoted rate deemed to be included for necessary safety equipments such as safety belt, ropes, helmets, netting etc mandatorily to be provided to labour working at height exceeding 3 mtr.
Repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damage portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed by Engineer-in-Charge
Repair of leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damage soil waste pipes or fittings of any shape, specification and size, making good to the damage portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and matching to existing wall complete to avoid the leakage/ seepage at the site of work as directed and specifie by the Engineer -in- charge
Note for item No 186 & 187 :- (a) Find out main cause of leakage and take necessary steps to resolve / rectify. (b) Replace existing tiles in case lakage through NT/FT. (c) The rate also include provision of new NT/FT. (d) The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as direct by the manufacturere specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit
PVC (SWR) 110mm bore P Trap including taken down existing one complete all as specified and as directed by Engineer-in-Charge
PVC (SWR) 110mm bore S Trap including taken down existing one complete all as specified and as directed by Engineer-in-Charge
Stack clamps made out of 50 mm x 5 mm flat iron and 110 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore complete all as specified and directed.
PVC (SWR) floor trap 75mm dia of outlet pipe, plain with grating including jointing with solvent cement
PVC (SWR) multi floor trap 75mm dia of outlet pipe, plain with grating including jointing with solvent cement
Stack clamps made out of 50 mm x 5 mm flat iron and 75 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore complete all as specified and directed.
Attending unserviceable/ non functional street light complaints (for street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillars etc) by deploying technically qualified and experinced techinicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for domestic area of old kalpa colony, new kalpa colony, Mehra colony, MAP qrts, Akash enclave, Gulmohar enclave, Kiran enclave, MES colony, AFWWA, various connecting roads and other facilities such as shoping complex/ various institutes/ messes/ play ground, complete perimeter etc located in complete domestic area and technical area at AF Station Sulur
Note for item No 195 : The following items are deemed to be inclusive of quoted rate :-
(a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
(b) 'Supply only' items to be delivered/ supplied to AGE E/M store yard as per qty asked by Engineer-in-Charge with in one calender month from the date of commencement of contract and these items will be issued from AGE E/M store yard for attending unserviceable/ defective street light complaints.
(c) Contractor or his Authorised Representitive has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day.
(d) A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User alongwith Contractor or his authorised Representitive.
(e) Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account.
(f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments to remove the breakdown. Fault will be intimated through Telephone/ SMS.
(g) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(h) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceabove as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regards shall be final and binding.
(j) Contractor has to ensure serviceability of all Street/ Security Lights of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.
(k) Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department.
(l) Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department.
(m) Materials required for the repairing of the lights shall be measured and paid separately under respective item(s). But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to be included in the rate quoted.
(n) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
(o) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
(p) All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
(q) Attending and repairing complaint for one light of any type shall be measured and paid as one Job.
(r) Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
(s) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
(t) Contractor shall provide contact details of his responsible person(s) for any emergency.
(u) Any Materials replaced which are not specified in SCHEDULE OF CREDIT will be deposited to MES STORE YARD without any extra Cost to the Department.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 10/16 sqmm 4 core size of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
Cleaning vegetation around the LT pole completely root out from soil and clean the surface one mtr around the pole of street lights. Note : Removing of accumulated earth depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine and removing the grass waste to outside MD land is deemed to be included in quoted rate.
S&F Power contactors 40 Amps, 4 pole, 415V, including taking down old item. Make : Cat No 412553 of Legrand or equivalent of L&T/ Siemans
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 160 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 120 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 76 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 45 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 36 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 20 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 10 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Polycab
Supply and fixing in replacement of TPN, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ Schneider/ ABB.
S&F in repairs Connector suitable for fixing of Cable of size Cross sectional area 10 Sqmm to 25 Sqmm armoured/PVC for preventing of Short Circuiting of Cable in Junction Boxes, complete all as specified and as directed. MAKE : HENSEL/ RITTAL/ GRASP
S&F in repairs IP 66 Pole Mounted street lighting Junction Box 160x240x120 mm made of Polycarbonate, supplied with 1 No. 6A 10KA SP MCB, 1 No. 63A 4P FR Polyamide color coded RYBN Terminals Block, 1 No. each of Earth & Neutral Terminal mounted on 35mm DIN channel and fitted inside Enclosure alongwith Pole Mounting bracket, pole clamp & hardware made of Stainless Steel 304. The Junction Box enclosure Cover should have 2 nos Polycarbonate Hinges with SS 304 Hinge pin, for Cover not to detach from Base on opening and should be properly tightened to base with Polycarbonate screws having sealing gaskets of extruded silicon rubber. The Polycarbonate enclosure should have properties Flame Retardant UL94V0, UV, Glow Wire test 960 Deg C, Impact IK08, Halogen free & RoHS compliant, Glow Wire Test for 960⁰ C. Type test reports from NABL lab in India along with Polycarbonate manufacturer batch test certificate should be submitted. Make of junction box shall be as per make mentioned in list of makes in PS.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25/ 35 sqmm 3.5 core size of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
Removing steel swaged tubular pole 8.5/9 mtr long for providing suitable new bracket for fixing street light and refixing the pole including necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) for foundation of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specified and directed by Engr-in-chrage.
Preparing the painted steel surfaces of existing LT steel tubular pole including cross arms, clamps MS flats, steel light bracket if any etc and applying one coat of aluminium paint(above ground/coping level) not exc 8 mtr long including painting of strips of height 0.3mtr each (three nos sky blue and three nos white), writing pole no with black paint with letters/figures 7.5 cm high and tightening of cross arms, clamps and street light brackets complete all as specified and directed.
Preparing the existing painted steel surface and painting with one coat of aluminium paint on cross arms, clamps, MS flat and street light brackets if any on Steel / RCC pole for Double cross Arm for three Phase 4 wire system.
Single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 including taking down existing one all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No : 408584 to 408595 or equivalent. of Schnieder (Multi -9)/ Siemens/L&T (Hegar).
Supply, transporting to site, errecting and fixing in position, steel tubular swaged poles of 9mtr long type 410 SP- 31 IS-2713 marked complete with CI/ MS base plate, finial taper plug, bolts, nuts, washers and screws as specified, drilling of necessary holes including painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and black bituminous paint on steel surface embeded in conrete externally and throughout internally and painting 03 nos of band /strips with fluorescent , PO box red synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and number of poles including taking down existing one all as specified & directed by Engineer-in-Charge. Note :- Earth work excavation, PCC foundation, coping will be measured and paid separately. The rate for pole shall also be included painting to steel tubular pole (in side and out side).
M&L in repairs cement concrete 1:4:8,type D2 (using 40mm graded stone aggregate ) including necessary form work for pole foundation complete all as specified and directed by Engr-in-Charge .
M&L in repairs cement concrete 1:3:6 type C2(using 40mm graded stone aggregate) including necessary form work for pole foundation complete all as specified and directed by Engr-in-Charge .
M&L in repairs PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in pole coping complete as directed.
Supply and fixing in replacement of power contactors 63 Amps, 4 pole, 415V, including taking down old item. Make : Cat No 412556 of Legrand or equivalent of L&T/ Siemans
GI tubing 40/50 mm bore light grade 1.2 mtr long bent to shape as required with clamps for fixing of street light on poles/ walls including nuts, bolts, washers clamps of suitable size including taking down existing one
Supply and fixing 30 watt LED Inverter RTC Street Light with inbuilt RTC (Real Time Clock) for AUTO ON/ AUTO OFF and must have DIMMING facility from 10 to 100% of Rated wattage as per user defined timeline. Housing made of Pressure Die Cast Aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, should have secondary lens for better optics, should have Constant current RTC enabled electronic driver with 5 KV SPD, IP66. Street light shall have inbuilt Li-ion battery of 5200 mAH and shall have >1.5 hrs battery backup at inverter load in case of power failure, Efficacy > 100 LPW, CRI > 70, THD <10%, PF >0.95, Cut off Voltage at 300 Volt + 10% and suitable for 50mm mounting pipe. Make :- Halonix Model No : HLSLD-ML04-30-CWL-INV-RTC-DIMM or equivalent in Philips/ Bajaj
Note for item No 242 :- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controling street lights including taking down old unserviceable timer switches complete all as directed. Cat Part No : 004702 of Legrand or equivalent in L&T, ABB.
Preparing surfaces by removing exisiting faded sky blue and white straps on PCC poles and applying a coat of sky blue/white straps painting with synthentic enamel paint, each sky blue/white straps of 30 cm height up to 1.5 mtr from top of PCC coating, writing pole no with white paint on black base of PCC pole by sentensile measure including applaying one coat of synthetic enamel paint to clamps/cross arm/street light GI bracket fixed on pole complete all as specified and as directed.
S&F in replacement of all in one integrated solar street light of less than 12W with 2000 lumen and system lumen efficacy of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70. Make : Philips Cat No BRP 710 LED 20 CW MR HY FDIM 50 Solar or equivalent in Wipro/ Bajaj.
Note for item No 246 :- (a) The unit quoted rate deemed to be included 6 mtr long MS/ GI pipe of 50mm bore medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge. (b) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (c) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (d) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (e) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module.
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified.
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
M&L Fly ash bricks in cable protection cover of any size complete all as specified and as directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :-The rate is deemed to be included for in case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge.
XLPE insulated, screened, PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ Polycab/ KEI
XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ Polycab/ KEI
Cutting existing road/PCC/Drain for laying of DI/GI or any typeof pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note for item No 255 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road
Supply only GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash
XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ Polycab/ KEI
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 10 sqmm to 16 sqmm Make : Reychems, Densons, M Seal
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 250 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 400 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ Polycab/ KEI
XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ Polycab/ KEI
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 25 sqmm to 35 sqmm Make : Reychems, Densons, M Seal
Supply and fixing 45 watt LED Inverter RTC Street Light with inbuilt RTC (Real Time Clock) for AUTO ON/ AUTO OFF and must have DIMMING facility from 10 to 100% of Rated wattage as per user defined timeline. Housing made of Pressure Die Cast Aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, have secondary lens for better optics, should have Constant current RTC enabled electronic driver with 5 KV SPD, IP66. Street light shall have inbuilt Li-ion battery of 5200 mAH and shall have >1.5 hrs battery backup at inverter load in case of power failure, Efficacy > 100 LPW, CRI > 70, THD <10%, PF >0.95, Cut off Voltage at 300 Volt + 10% and suitable for 50mm mounting pipe. Make :- Halonix Model No : HLSLD-ML04-45-CWL-INV-RTC-DIMM or equivalent in Philips/ Bajaj
Note for item No 272 :- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Integrated solar street light of less than 18W with 3000 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70 including taking down existing one all as directed. Make : Philips Cat No BRP 710 LED 30 CW MR HY FDIM 50 Solar or equivalent in Wipro/ Bajaj.
Note for item No 274 :- (a) The unit quoted rate deemed to be included 6 mtr long MS/ GI pipe of 50mm bore medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge. (b) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (c) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (d) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (e) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module.
Taking down existing GI strip 32x6mm thick as earthling lead with its accessories and re fixing to wall/roofs etc. drawn in conduit/GI pipe etc all as specified and directed. Note:- Unite rate is deemed to be included for old broken insulators/ clamps replace with new insulators of existing size from site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.
Checking of any breaking in the link of earth strip wire of Galvanised/Copper/Aluminium Strip any size and jointing them by Exothermic Welding or Brazing including taking down old unserviceable one, complete all as specified and as directed.
Air Termination Single Pointed Aluminium Rod 16mm dia and 300mm long with Arrester Clamp 16mm made out of Brass/ Gun Metal including provision of Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm and necessary Fixing Arrangement at Roof, all Joints should be connected by Exothermic Welding or Brazing complete including taking down existing one all as specified and as directed.
Earth test point for down conductors on wall with 32x6mm GI strip, 25x3mm aluminium strip, epoxy insulator and GI bolts, nuts and washers complete including taking down all as specified and directed by Engr in charge.
Arrester clamp for lighting arrester of size 16mm made out brass including taking down old unserviceable one, complete all as specified and as directed.
Cable to tape junction clamp for connecting PVC copper/ aluminium cable with the earth strip made out of brass including taking down old unserviceable one, complete all as specified and as directed.
GI strip 32 x 6mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed.
Aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down existing one all as specified.
Epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc including taking down existing one all as specified. NOTE : Quoted Unit Rate deem to be included drilling holes per Metre or as specified on GI/Aluminium/Copper Strip of any type and size.
Brazing / exothermic welding arrangement for existing copper strip of size 32 x 6 mm / 20 x 3 mm thick complete all as specified and directed.
Connecting of copper strip with aluminum strip including bi-metal nut, bolts and washers complete all as specified and directed.
Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw including taking down old unserviceable one, complete all as per specified and as directed.
Air termination single pointed aluminium rod of 12mm dia 300mm length fixed to GI strip 32x6mm/aluminium strip 25x3mm including nuts, bolts and washers including taking down old unserviceable one, complete all as specified and as directed.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in ISG Global/ ERICO.
The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (copper strip will be measured and paid separately).
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
S&F in repairs Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed. Note : All Joints should be joined by Exothermic Welding or Brazing.
M&L Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model EGTEK3LC of ISG Global or equivalent in ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
60W LED inverter Flood light with inbuilt real time clock (RTC) for auto ON/ OFF feature, emergency light output, shall have maximum 1.5 – 2 hours battery back up with Li-ion battery at inverter load in case of power failure, system lumen not less than 100 lumen, initial lumen at battery mode will reduce to 15-20%. Housing made up of pressure dicast aluminium body with Top maintainable and front cover clear toughened glass, with IP 66 and IK05 protection, open and short circuit protection, reverse polarity protection, high voltage cut off at 300V + 10V and 5 KV internal surge protection, PF > 0.95, THD < 10% and Driver Efficiency > or = 85%. CRI > or = 70. Make :- Halonix Model No - HLFLD-ML30-60-CWL-INV-RTC-DIMM or equivalent of Philips/ Bajaj.
Note for item No 310 :- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
M&L for saddling of LT XLPE UG cable of size 10 to 25 sqmm 3.5/ 4 core on wall by using suitable size of galvanised iron saddle clamp each one meter intervals all as specified and as directed by Engineer-in-charge.
Supply, install, testing & commissioning of Factory assembled, floor mounted free standing type, weather/ vermin proof outdoor type street light Panel having MCCB of 100 Amp capacity, 4 pole, 415 V, 25 KA as incomer and three units of output 3 pole power contactor 25 Amps, 50 Hz, 415 V. The panel shall have Dusk to normal illumination sensor for automatically operating of the lights based on lux level of natural light and astronomical external timer to operate lights as per sunrise and sunset timing. The panel should also have GSM based controller cum protection device for safety of lights from electrical fault and monitoring of all parameters through SMS by max 4 users. The GSM device shall have SPECIAL ZERO CROSSING SWITCHING OPERATION PROTECTION SYSTEM WITH PROVISION OF SCROLLING DIGITAL DISPLAY OF LINE PHASE VOLTAGES, LINE CURRENTS and network strength in percentage alongwith the following specification :- Power consumption 15VA / 3W Setting Accuracy Voltage ± 5V, Minimum setting current 2A, Maximum setting current = 99 A. Setting Accuracy Current ± 5% of full scale ±1 digit, settable Trip time delay 3 to 30 secs settable for OV, UV, OC & UC, Trip time accuracy ± 1% of set delay ±3 sec, trip setting, set, Phase, Under Voltage and over voltage 5V to 60V AC. Recovery Time 2 sec Min Power On Delay10 sec Max., PROTECTION SYSTEM SHOULD BE PROVIDED WITH EACH FAULT DIGITAL, having Intelligent street light controller specially designed for energy Saving in conventional street light systems.
External timer should have auto calculate ON/ OFF time as Sunrise and sunset time changes on day to day basis. The GSM controller should also provided with real time clock having Advance Microcontroller based design and real-time clock base systems. Real time clock with inbuilt battery having life more than 5 years and Data protection of users parameter by specially RAM which hold the parameters without any power. GSM Controller shall operate 365 days on real-time based clock with predefined on/off time and shall have inbuilt auto recovery systems in case of power failure which helps in streetlight operation, Password protected (as unauthorized call should not be allowed to operate the lights), Scrolling display of events which helps to monitoring the current, voltage and network status. The entire system will operate for 25 Amp per Output with Bye pass feature of all output channel. Each channel shall have output protection with the help of 25 Amp SP MCB to repair/test the security lights in day timings. The SMS should contain all information of power on time, power off time, power on period, power of period, current, voltage and power consumption in Kwh. The GSM shall have ABS Encloser Box. The panel should operate on four modes :-1) GSM mode 2) Timer mode 3) Sensor mode 4) Bypass mode. The GSM device should be able to monitor all events through SMS on all modes. For easy understanding and troubleshooting of fault on site the device shall have indicator for supply, timer, supply fault, overload, underload and output fault. GSM controller shall be operated in following modes :- 1) Use switches given on the unit 2) Dial the GSM SIM card inserted in the unit and use voice interactive service 3) By sending SMS to unit to do /set all the parameters. Monitoring on Display on data logger 1) Calibrated Digital Voltmeter 2) Calibrated Digital Ammeter 3) On site AUTO FAULT DETECT (AFT) for AC voltage, LEDS, Display, Relay, etc.
The Panel shall have the following Additional Features a. Molded sticker waterproof high gain antenna for GSM signal reception b. 4 Digit Password protected operation c. Facility to check network communication between GSM SIM and dialer phone d. No call charges when power is absent. e. Auto call disconnect facility to save call charges f. Light ON and OFF switch on unit g. High voltage stand capability h. Clock based timers j. Indication for incoming / Outgoing SMS k. Indication for Incoming Ring l. Universal mobile no GSM Compatibility m. Calibration For Current Measuring Transformers facility n. Display shows GSM network strength % and also send by SMS to user. o. SIM Tracking facility p. Call back facility q. Auto start unable / disable facility Make :- M/s Recktronic Devices & Systems, Marsh Automation, Kewintech, Universal Switch Gear and Control
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 400 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note for item No 318 :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
S&F Galvanised earth strip of size 25 x 6mm fixed on proper post insulator at the instrument end complete all as specified and directed.
SUPER COOL
KSR AND COMPANY
KUMAR AGENCIES
pk janardhanan
J and K constructions company
K T ASSOCIATES
devan enterprises
M/S SRI BALAJI ENTERPRISES
Lucky Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .