Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.1 L+₹1.3 L (5.50%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹25.5 L+₹1.7 L (7.36%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹26.5 L+₹2.8 L (11.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
10 Jun 2023, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT TO ROOF TREATMENT LEAKAGE SEEPAGE AND INTERNAL EXTERNAL PLASTERING OF CERTAIN BLDGS OHTs FLOAT VALVES STOP VALVES WATER PIPES TANK COVERS CLEANING OF WATER TANKS OF OTM MD ACCN AT SI LINES AREA UNDER GE BHOPAL
2023_MES_595509_1
8983/E8
Open Tender
Civil Works
Works
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹70,000
Yes
13 Jul 2023
15 May 2023
12 Jun 2023
15 May 2023
10 Jun 2023
29 May 2023
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Taking down plants / vegitable growth etc from buildings by cutting /chiseling fully without disturbing structure up to height of 10.00 m from average ground level at different location and cleaning the surface neatly with wire brush to remove dust and other foreign particles and applying hydrochloric acid (HCL) on leftover root portion and making good the disturbed surfaces in cement mortar 1:4 complete all as specifed and directed.
M&L for crack filling with approved crack filling compound of M/S Pidilite or equivalent including necessary opening of cracks, cleaning, watering etc including necessary scafolding etc up to height of 8.00m from ground level complete all as specified and directed. Note: -The quoted rates is deemed to include for the cost of scaffolding, T&P, etc required for execution of the work at height approx 10 m height of building roof having continuous trapezium with no staircase.
Taking down existing old roof treatment of any description, any type including removal of old Tar felt, screed bed and plastering etc complete all as specified and directed.
M&L for roof treatment to RCC roofs with and including comprising of following steps:- (a) Preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle. (b) Providing bituminous primer grade 85/25 bitumen @ 1.2 kg/sqm in each coat to be applied on prepared surface till the surface is properly impregnated. (c) Applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application. (d) M&L for rendering 10 mm thick in cement mortar 1:4 over RCC slab mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction complete all as specified and directed. (e) M&L for ponding test by filling 75 mm deep water over roof treatment by making necessary arrangement to fill the roof slab at least for 72 hrs complete all as specified and directed. Note :- Taking down carefully cables and ACs and removing materials to MES store for keeping in safe custody for re-use at site in functional as earlier and making good disturbed surface of walls, floors, roofs etc. complete all as specified and directed.
M&L for cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) benching/ angle filleting at the junction of parapet and RCC roof complete all as specified and directed.
M&L for cutting grooves or chases in brick wall, 75 mm wide and 65 mm deep and including filling with cement mortar 1:4 mixed with water proofing compound complete all as specified and directed. (Note;- Water proofing compound shall be measured and paid separately as supply only)
M&L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid separately.
M&L for grouting for permanent bonding of strutural damage/crack, porosity of concrete to attend leakage/seepage with pressure grouting with 15mm bore GI Pipe nozzle under the pressure of 5 kg/sqcm using cement based grout, treatment to be made as per manufacturer instructions complete all as specified and directed.
M&L for providing drip course in chajjas of bldgs to facilitate the drainage of water from the coping with cutting grooves on the underside of chajja including making good disturbed surfaces in CM 1:4 complete all as specified and directed. Note: -The quoted rates is deemed to include for the cost of scaffolding, T&P, etc required for execution of the work at height approx 10 m height of building roof having continuous trapezium with no staircase.
Demolition of lime/cement concrete in ground floors and paving in any position complete all as specified and directed.
M&L for cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundations, filling of sunken and mass-concrete etc. complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:3 on fair faces of brick work, concrete surfaces as in sunken/ roof treatment finished even and smooth without using extra cement incl applying two coats of acrylic polymer treatment as per manufacturer instructions complete all as specified and directed. Make: CICO (Tape Crete) or equivalent as approved by GE.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
Dismantling asbestos cement (Corrugated, semi corrugated, etc) sheets including ridges in roof covering complete all as specified and directed.
Dismantling timber fillet, rafter, purlins, scantlings under 40 sqcm in section, in any position in frame work complete all as specified and directed.
S&F of pre-painted galvatume aluminium zinc coating GI base corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screw complete all as specified and directed.
S&F pre-painted plain galvalume aluminium zinc coating GI base plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in ridges, hips, valley gutter, drip and straight flashing (length and girth fixed) roof covering /cladding to wall fixed with self tapping screw complete all as specified and directed.
S&F of mild steel work in tubular trusses including special shaped washer etc. using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 complete all as specified and directed.
M&L for preparation of new steel surface of any description and applying two coats of synthetic enamel painting over one coat of red oxide primer complete all as specified and directed.
M&L for applying ShaliCryl ® 215 single component, UV resistant, unique elastomeric, high build exterior waterproofing coating based on a revolutionary acrylic polymer with quick-set capabilities to resist moisture attack with and including comprising of following applicators steps:-
(a) Surface Preparation :- Remove all loose and foreign materials, if any, by a wash with a jet of air / water. • Repair structural defects before application of ShaliCryl® 215. • Fill voids and undulation area with Polymer Mortar made out of ShaliSBR Latex, Water, Cement and Sand in the Ratio of 1:1:5:12.5. • Fill cracks up to 3 mm with PlastiSeal and cracks over 3 mm with PlastiSeal P after opening the crack to a “V” cut. • In case of any poor plaster surface in existence (for old building), remove the same and corrected with new cement : sand in the ratio of 1 : 4 admixed with ShaliPlast LW+ @ 200 ml / bag of cement.
(b) Primer Application :- Apply ShaliPrime WB as Primer after dilution with potable water in the ratio 1:0.5 for a theoretical Coverage 8-10 m2 / L of the mix and allow it to dry for 3 – 4 hrs. post elimination of undulation, roughness of concrete, joint marks, Voids and any other surface correction.
(c) Application of Material • Apply first coat of ShaliCryl® 215 over the primed surface @ 160 ml / m2 . Add maximum of 10% potable water by volume for the first coat only, if required, to have brushable consistency only. • Allow the applied coating to dry 6 – 8 hrs of application. • Apply second coat of ShaliCryl® 215 without dilution over dried first coat @ 140 ml / m2 and allow it to dry. • Do not undertake any further work over the coated area within 72 hrs of final coat. • A coat of 100 micron of ShaliCryl TC 100 will improve water / dust repellent property.
Taking down of rain water pipes of any size or pattern including all fittings etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 75 mm bore complete all as specified and directed.
S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl ISI marked 110 mm bore complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of 110 mm bore of pipe with access door complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or un equal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or un equal of 75 mm bore of pipe with access door complete all as specified and directed.
S&F PVC (SWR) branch piece 110mm bore, single (single Y) equal or unequal complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of walls and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old decorated plastered surface of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surface of ceiling and applying two coats of white washing complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of exterior weather proof water base emulsion paint over and incl a coat white cement based putty complete all as specified and directed.
M&L for removal of existing treatment and applying two coats of exterior weather proof water base emulsion paint over and incl a coat white cement based putty complete all as specified and directed.
M&L for removal of old decorated surface of wall and applying two coats of oil emulsion distemper (white/tinted) over and including one coat of white cement based putty complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil emulsion distemper (white/tinted) over and including one coat of white cement based putty complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall including brooming, scraping down, smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and one coat of oil emulsion distemper complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall including brooming, scraping down smoke spot, moulds, moss, efflorescent salts, trading oil, greasy spots and stopping nails marks and applying one coat of exterior weather proof water base emulsion paint on walls complete all as specified and directed.
M&L for providing 3mm thick coat of white cement putty on walls/ceiling complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old steel surfaces of any description over 10cm girth or widhth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls and including wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 15 mm thick cement mortar on brick/stone surfaces or surfaces other than fair faces of brick work in cement mortar 1:6, even and smooth finish without using extra cement, in patches complete all as specified and directed. Note: -The quoted rates is deemed to include for the cost of scaffolding, T&P, etc required for execution of the work at height approx 10 m height of building roof having continuous trapezium with no staircase.
M&L for rendering 15 mm thick cement mortar on brick/stone surfaces or surfaces other than fair faces of brick work in cement mortar 1:4, even and smooth finish without using extra cement, in patches complete all as specified and directed. Note: -The quoted rates is deemed to include for the cost of scaffolding, T&P, etc required for execution of the work at height approx 10 m height of building roof having continuous trapezium with no staircase.
M&L for 10 mm thick rendering in cement mortar 1:4 on fair faces of ceiling surfaces complete all as specified and directed. Note: -The quoted rates is deemed to include for the cost of scaffolding, T&P, etc required for execution of the work at height approx 10 m height of building roof having continuous trapezium with no staircase.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M&L for single component polymer modified repair mortar with compressive strength minimum 38 MPA at 28 days (ASTM C 109:99) and tensile strength minimum 2.5 Mpa (ASTM C 307) up to 15mm in a single coat @ 34 kg per sqm for 15mm thickness as per manufacturer instructions complete all as specified and directed.
S&F of hard drawn steel wire fabric weight n.exc 4 Kg/Sqm cut to lengths, bent to shape tying with and including mild steel wire, (annealed) not less than 0.9mm dia as in reinforcement to the height of up to 14 m from ground level complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Use & work of formwork to chajjas, troughs and similar items including edges for rough finished complete all as specified and directed.
Use & work of formwork to fins, louvers, fascia for rough finished surfaces complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10 cm wide complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections complete all as specified and directed.
Taking up or down 25mm bore steel tubing and connections complete all as specified and directed.
Refixing only of GI tubing medium grade 15 mm dia in new/old position after cleaning of pipe with all fittings and fixed to walls or laid on floors at complete all as specified and directed.
Refixing only of GI tubing medium grade 20 mm dia in new/old position after cleaning of pipe with all fittings and fixed to walls or laid on floors at complete all as specified and directed.
Refixing only of GI tubing medium grade 25 mm dia in new/old position after cleaning of pipe with all fittings and fixed to walls or laid on floors at complete all as speicified and directed.
S&F of 15 mm bore GI tubing medium grade, galvanised with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F of 20 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings in trenches complete all as specified and directed.
S&F of 20 mm bore GI tubing medium grade, galvanised with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F of 25 mm bore GI tubing medium grade, galvanised with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Dismantling water tanks of capacity exc 250 litres but nexc 500 litres complete all as specied and directed.
Dismantling water tanks of capacity exc 500 litres but nexc 1000 litres complete all as specied and directed.
S&F of 500 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) Dimen hoisted and fixed in position as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed.
S&F of 1000 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed.
S&F of 20mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F of gunmental, globe or gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs to 25 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F in repairs to 20 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F in repairs to 15 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F in repairs to gunmental, globe or gate valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs to gunmental, globe or gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs to gunmental, globe or gate valves 15 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs to PVC Tank Lid (Cover) for tank of 500 Ltr capacity including locking arrangement with pad lock of Godrej size 50 mm (steel) complete all as specified and directed.
S&F in repairs to PVC Tank Lid (Cover) for tank of 1000 Ltr capacity including locking arrangement with pad lock of Godrej size 50 mm (steel) complete all as specified and directed.
M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity not exceeding 500 Ltr of any description and in any position comprising following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using Trebac G5/Inchlor-5/NB-10, Terbac G65/Inoxi-60/NB-69 and ultra violet rays complete all as specified and directed with and including of following steps:- (a) First stage is to drain out the water by using exit valve or our own high capacity dewareing systems or any other suitable method approved by Engr-in-Charge. (b) Second stage is cleaning all the algae formation inside the tank by using Terbac G 10/ Inchlor-5/NB-10, a laboratory tested barnded chemical of the company and scrubbing the walls of the tanks. (c) Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSL. (d) Fourth stage first bacteria screening and sterilization by using Terbac G5/Inchor-5/ NB-10, a Laboratory certified branded halogen compound, test certificate of TerbacG5/Inchor-5/ NB-10, from government laboratory mentioning suitability for sterilization. (e) Fifth stage is cleaning the floors of the water tank by heavy duty industrial vaccum cleaner. (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray ejector covering 360 degree with in the tank and kills all suspended bacteria. g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TerbacG65/Inoxi-60/NB-69. Note:-(i) Test certificate of Terbac G65/Inoxi-60/NB-69 from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (iii) Contractor will be responsible for rectification of complaints occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/blockage of Outlet lines due to silt and rectification cost will be deemed to be included in quoted rate. Note: The work shall be carried through specilized agency as approved by GE/Engr-in-charge.
All as per item No. 85.00 here-in-before but of tank capacity exceeding 500 Ltrs and not exceeding 1000 ltrs of any description and in any position.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconneting and refixing in position capacity exc 250 and n exc 500 ltr. including cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipes etc complete all as specified and directed.
All as per item No. 87.00 here-in-before but of tank capacity exceeding 500 Ltrs and not exceeding 1000 ltrs of any description and in any position.
Deduct Schedule of credit (calculation will be done off line) Rs. 44800.00
ROYAL CONSTRUCTION
Samaksh Enterprises
R K Sales
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .