| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | L1 | Accepted-AOC Bidder is L1. Recommended for award of contract and approved by the competent authority. | |
| 2 | Rejected-Technical 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical L-2 BIDDER. DOCUMENTS NOT EVALUATED. BID IS TO BE REJECTED. | |
| 3 | Rejected-Technical 01 MADHU BHAWAN FIRST FLOOR FLATE NO 01 NAWADIH DHANBAD JHARKHAND 828130 | DHANBAD | JHARKHAND | 828130 | - | Rejected-Technical L-3 BIDDER. DOCUMENTS NOT EVALUATED. BID IS TO BE REJECTED. |
Tender Value
₹2.8 L
EMD Value
₹3,600
Closing Date
7 Feb 2024, 3:00 pmClosed
PE(ENM)
OFFICE OF THE PROJECT OFFICER, BOKARO COLLIERY, BNK AREA
Onsite electrical repair and maintenance of three (03) nos. Starters 3.3KV grade, 200 Amps engaged for starting of various pumps i) 3.3KV 200Amps Andrew Yule make currently engaged at Cutting Pump, ii) 3.3KV 200Amps starter engaged at DD mines pump
2024_CCL_299845_1
CCL/BnK/Bokaro/EnM /23-24/24
Open Tender
Electrical and Maintenance Works
Item Rate
8 days
BOKARO COLLIERY
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,600
2 Dec 2024
30 Jan 2024
8 Feb 2024
30 Jan 2024
7 Feb 2024
30 Jan 2024
30 Jan 2024 - 3 Feb 2024
Amount
Supply & providing of electronic Motor Protection Relay with protection for Thermal Overload, Short Circuit, Earth fault, Phase loss, Unbalance, Phase reversal, Under Current, Locked Rotor operating at 110V
Replacement of Vacuum Interrupter of 3.3KV 200Amp grade
Supply & fixing of fixed sliding contact as per sample
Supply of push button of suitable size (red/ green)
Replacement of Current Transformer of suitable type of ratio 60/30-5
Replacement of Potential Transformer (PT) of suitable type of grade 3.3KV/110V
Supply and providing of HRC fuse with base
Replacement of Ampere meter of suitable range as per sample size
Replacement of Voltmeter of suitable range as per sample size
Replacement of tripping coil 110V of standard make
Replacement of closing coil 110V of standard make
Connection & rectification of control circuit with supply of ferrules, lugs and other accessories for connections
Replacement of Bushing insulator of 3.3KV grade
Overhauling, cleaning and painting of the starter
Total impact of GST for the purpose of CTC
M/s Kiran Electrical works
Vedant Enterprises
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .