| 1 | L1₹8.0 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L1 | Accepted-AOC work order has been awarded | |
| 2 | L2₹9.2 L+₹72,811 (8.55%)Rejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance Not L1 |
Tender Value
₹7.8 L
EMD Value
₹15,550
Closing Date
29 Jun 2022, 12:00 pmClosed
EEE-II Shah(S)
2 nd Floor Technical Laboratory Near NH-24 Ghazipur Delhi
Emergency repair of Electrical installation of various Mpl assets in ward no 13E (Kishan kunj), 17E (vishwas nagar), 18E(Anand vihar), 19E(I.P.Extension), 20E (preet vihar), 29E (vivek vihar), 30E (Jhilmil),31E(Shahdara) total 8 no.s of wards under s
2022_EDMC_119968_1
EE (Elect)-II//2022-23/4.1
Open Tender
Electrical Works
Item Rate
180 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹500
₹15,550
23 Jan 2025
22 Jun 2022
30 Jun 2022
22 Jun 2022
29 Jun 2022
22 Jun 2022
Amount
Part-A Deputing following staff for attending emergency electric complaints in one shift on all working days in various Mpl assets in AC 59 &AC 62 Shd.south zone EDMC for SIX months (6 Months):- (a) Wireman - 1 nos. in 1 shift
(b) E/Beldar - 1 nos. in 1 shift
Part-B Supply of 1.5sqmm FRLS PVC insulated copper conductor single core wire complete as required.
Supply of 2.5sqmm FRLS PVC insulated copper conductor single core wire complete as required.
Supply of 4.0 sqmm FRLS PVC insulated copper conductor single core wire complete as required.
Supply of 6-32Amp single pole MCB 240/415V C-series complete as required.
Supply of sub main with 6 sqm size of WP twin core Al conductor cable as reqd
Supply of PVC conduit required of following sizes. a)20 mm
Supply of PVC bends required of following sizes. a)20 mm
Supply of 20 mm PVC junction box, two way
Supply of 63Amp double pole Isolator MCB 240/415V complete as required.
Supply of PVC insulating tape of 1.8cm width 10mtr length as required.
Supply of 5/6 Amp Batten Holder (Polycarbonate) as required.
Supply of PVC Gang box suitable for 5 amp switch /Socket.
Supply of 0.5 H.P. single phase mono self priming pumping set suitable for a head of 6 to 30 mtr. Discharge 3300 to 400 LPH and suction / delivery 25X25 mm suitable to work 180 to 230 volt, A.C. supply .
Supply of 5/6 Amp piano type switch ISI marked as reqd.
Supply of 5/6 Amp 5pin socket ISI marked as reqd.
Supply of 15/16 Amp piano type switch ISI marked as reqd.
Supply of 15/16 Amp 5pin socket ISI marked as reqd.
Supply of LED Tube type luminiare 20watt rating box type complete with Extruded Aluminium Batten prewired with high efficient LEDs with following specification as reqd. ( a )Total system wattage= 20watt+/-5% (b) Luminiaire Efficiancy>=95Lm/w . (c) Power Factor>=0.95
Supply of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way , Double door
supply of 250 mm sweep 1400 rpm fresh air fan complete with shutters,blades etc as required
Supply of phenolic laminated sheet 3.00mm thick ISI Marked as reqd.
Rewinding of AC ceiling fan / Exaust fan of all sizes and make i/c oiling, greasing as required.
Supply of wall fan /ceilingfan capacitor 3.15 mfd as reqd.
Supply of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Part-C Lifting of existing submersible pump set with its all acecessories form well and lowering the same along with all accessories from depth 50 meter to 100 meter complete as required
Rewinding of single phase 1.5 HP A.C motor of vertical type multistage submersible pumpset (Dismantle material will be retained by the contractor)
Rewinding of 0.5 H.P. single phase mono self priming pumping set9(Dismantle material will be retained by the contractor) etc as required
P and F following sizes of PVC insulated and PVC sheathed copper conductor 3 core submersible cable confirming to IS.647/1990 etc. as reqd. Elec94.a 3 X 2.5 sq.mm.
Supply, installation, testing and commissioning of cubical type control panel board for single phase submersible pumping set of following rating complete with contractor, relay, M.C.B, condenser, Voltmeter, ammeter and indication lamp etc including connections as reqd. )A)-1.5 H.P. rating submersible P/Set.
Supply, lowring and fixing following size G.I. pipes(M-Class) i/c cutting, threading on both side etc ISI Marked as reqd. 25 mm dia nominal bore
Supply, lowring and fixing following size G.I. pipes(M-Class) i/c cutting, threading on both side etc ISI Marked as reqd. 32 mm dia nominal bore
supplying,lowerig,testing and commissioning of following capavity vertical type ,multistage, totally enclosed ,water filled, deep well sumbersible pumping set complete i/c connection etc a required a single phase 1.5 H.P. having discharge of 72 LPM at 49 M head
Redevelopment of existing bore of following sizes 100,150,200 &250mm
SRI BALAJI ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .