UP GRADATION OF AAM AYUSH DISPENSARIES REQUIREMENT OF CCTV CAMERAS AND INVERTORS IN DISPENSARIES SECTOR 37 AND 41 (BADHERI) CHANDIGARH.(PROVIDING CCTV CAMERAS).
2026_CHD_90750_1
E3/47W/214
Open Tender
Electrical Works
60 days
Chandigarh
as per NIT
3 documents required · 3 mandatory
₹0
₹18,100
Chandigarh
13 May 2026
19 Feb 2026
2 Mar 2026
19 Feb 2026
2 Mar 2026
23 Feb 2026
23 Feb 2026
4MP IP IR Outdoor Bullet Camera DSR Item No. 40.4 (2025) Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following spcifications and features etc as per complete item No.1 of DNIT.
4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement)
4MP IP IR Dome Camera DSR Item No. 40.3 Supplying Installation Testing and Commissioning of 4MP IP IRDome Camera having following spcifications and features etc as per complete item no.2 of DNIT.
4MP @ 25/30fps@1440P (2560 x 1440) Dome Camera with 2.8/ 3.6/ 6/8/12 mm fixed lens (as per site requirement).
DSR Item No. 40.11 Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below as per complete item No.3 of DNIT.
32 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16
42.4 LED Display Supplying, Installation, Testing and Commissioning of followingsize LED display (LED monitor) industrial grade with3840x2160 resolution or better, USB playback, bluetooth andmiracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+,brightness: 500-nits or better, Video wall mode should beavailable, contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Display control shallbe on monitor screen and programmable with remote (remoteshall be supplied with system), Key Board, Optical Mouse, etc.as required.
32 inch or larger
DSR 40.12 (2025) Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
8TB (Terabytes)
DSR Item 39.1(2025) Supplying, installation, Testing and commissioning of followingcapacity 8 port Layer 2 indoor Network Switch having featuresand specifications etc. as mentioned here under: Minimum 8 XRJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Portswith non-blocking architecture by having Switching capacity ofminimum 20Gbps and packet forwarding rate of 14Mpps orhigher, 8K MAC table. Internal dual AC Power supply withoperating temperature of -5 degree Celsius to +50 degreeCelsius. Jumbo frame: 10KB or higher, IGMP Snooping, IGMPsnooping querier and support for IGMP Snooping Fast Leave,Should create 250 or more MLD groups, MLD Snooping, PerVLAN MLD Snooping C MLD Snooping Fast Leave, STP,RSTP, MSTP, Loopback detection, Multicast filtering, VLANTagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interfaceminimum 100 IPv4 static route entries and minimum 50 IPv6static route entries, 700 Acess Control entries, SSH CSSL forIPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping andserver screening, IP+MAC+Port Binding, Per Port BandwidthControl, 802.1X Authentication (Supports local/RADIUSdatabase, Port-based Access Control and EAP, OTP, TLS,TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDPMED,SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps.Certifications:FCC, CE marked, UL/EN, RoHS and relevant MTCTE (TEC)/ BIS compliance/ certification as applicable, etc. complete as required.
8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+.
39.23 Supply and fixing of following size Wall Mount Rack havingFixed Structure with 0.8mm CRCA Sheet, completelyknocked-down condition (CKD) Shape, Vertical Mounting Rail1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provisionat Top and bottom with rubber protection, Front 5mmToughened Glass with lock, wall mounting kit, Powder coatedColor- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets16A power distribution units, 3 numbers closed cableorganizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
9U Rack
DSR 39.12 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D Copper Patch Cords of length 1m (3ft)
DSR 39.11Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
DSR Item No. 26.1 Online UPS - Input supply: Single Phase, Output Supply : SinglePhase Supplying, installation, Testing & Commissioning of followingcapacity at full load (Unity Power Factor) ON LINE UninterruptedPower Supply (UPS) system suitable for Single Phaseinput,Single Phase output AC Supply. The UPS shall include aRectifier, inverter, battery bank suitable for 30 minutes back up(Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shallbe VRLA, SMF in ABS Container) and Static Bypass switchalongwith manual bypass, suitable isolationtransformer for additional protection against neutral faults etc.The UPS systems shall be Microprocessor based DigitalControl, using Insulated Gate Bipolar Transistor (IGBT)'s bothfor the rectifier & inverter with PWM (Pulse Width Modulation)Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-nationalstandards such as IEC/EN/VDE. The operating efficiency of theUPS systems shall be >95% at 100% non-linear loads. Currenttotal harmonic distortion(ITHD)/ total demand distortion (TDD)on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit tobe include to limit the input pf to 0.99 and output power factorshall be unity (i.e. kw rating of the UPS shall be kva rating x 1 )however UPS shall be suitable to take load at 0.7 laging to 0.7leading power factor loads. UPS shall be suitable for incomingsupply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150%for 1 minute.Operating temperature 0 to 40 deg C, Relative humidity 0-95%non condensing, noise level less than 60db at 1 meterdistance,Protection for Under voltage, over voltage, abnormaloutput voltage, battery over charging, output over current, shortcircuit, battery deep discharge , 10 KV surge. Display forwatt/VA,Amp and Voltage power parameters etc. UPS shallcomply with low voltage electromagnetic compatibility (EMC)achieved as per EN 6204, EN6204 Part I and Part 2, it shall bea Voltage and Frequency Independent (VFI) type UPS (as perstandard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks,DC breaker of suitable rating and interconnecting copperconductor cable of suitable size and connectors and all requiredaccoseries are inclusive in the cost. The UPS should have QRcode which should contain drawing, test report OEMmanual,Geo- Tag of manufacturing location etc
DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm
DSR 39.18 Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL.
1 run of cable
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Providing AMC for CCTV under item No.1. Under the AMC the supplier shall provide comprehensive Mtc. service of the DG set including the spares and there shall be no hidden cost. Preventive Mtc. service of the equipment under AMC must be carried out once in fortnight. During the period of AMC service/repair calls are to be attended by the supplier within two hours from the time of such calls. The defective equipment should be repaired on the same day at purchaser’s location. In case of major defects requiring the defective card/item/ equipment to be taken to the supplier workshop. It should be returned within a week’s time duly repaired and immediate substitute card/item/equipment will be provided by the supplier for the smooth operation of the lifts. The to and fro transportation of the card/item/equipment will be the responsibility of the supplier. Delays in attending the calls and or repairing the defective equipment beyond time limit of one day will attract penalty @ Rs.500/- per day. The bidder will undertake the supplies of necessary Mtc. equipment and spare parts will be made available for all the equipment and the complete system for a period of 5 years on continuing basis 1st year free and thereafter for four years on paid basis. The bidder shall quote the rates on per year basis.
For 2nd year
For 3rd year
For 4th year
For 5th year
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 10.02 MB
BOQ_110983.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid