Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹10.3 L+₹49,279.50 (5.02%)Rejected-Finance WARD NO 07 WARD NO 07 THANA PARA NALHATI BIRBHUM WEST BENGAL 731243 | BIRBHUM | WEST BENGAL | 731243 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹10.4 L+₹59,049.03 (6.02%)Rejected-Finance VIKASH NAGAR RAMGARH CANTT HAZARIBAGH JHARKHAND 829122 | RAMGARH | JHARKHAND | 829122 | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹10.5 L+₹68,838.07 (7.01%)Rejected-Finance E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹10.5 L+₹69,686.40 (7.10%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L5 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹19,500
Closing Date
22 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF SINGARSI
AGE I AF SINGARSI
Spl Rep to feeder pillar box including replacement of LT cable at SMQs 70,94,92 and 62 Blocks and Certain Revenue and Minor works BR and EM at AF Stn Singarsi under AGE I AF Singarsi
2020_MES_382277_1
C/8495/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹19,500
Yes
5 Nov 2020
30 Sept 2020
24 Oct 2020
1 Oct 2020
22 Oct 2020
7 Oct 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in soft/loose or any other type of soil for taking up or laying of cable all as specified and directed.
All as per item No 1 above but hard surfaces such as in road cutting/ hard standing etc including making good disturbed surfaces to match with original complete all as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms.
Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point.
Supply and laying new dry river sand laid in trenches 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering all as directed. Note:- Punned quntity will be measured and paid at this item.
Supply and laying of PCC cover of sizes 250mmx150mmx40mm for cable protection in trenches width of brick perpendicullar to the length of cable including taking up of old UNSV bricks complete all as specified and directed by Engr-in-Charge.
Supply and Fixing in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor (multistranded), 1100 volts grade connected with suitable cable gland and aluminium lugs of any size laid in trenches or passing through pipes including testing after laying, including taking up old UNSV cable complete of following size all as specified and directed by Engineer-in-Charge of Size 16 Sqmm 4 Core.
All as per item No 7 above but 50 sqmm 3.5 core
All as per item No 7 above but 6 Sqmm, 2 core
Supply and Fixing in replacement of GI pipe 50mm bore light grade (ISI Marked) for cable protection along wall/pole/floor/road crossing etc complete including sealing of pipe ends with approved sealing compound including taking up old UNSV GI pipe complete all as specified and directed by Engineer-in-Charge.
Material & labour for earthing galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including galvanized steel strip 25mmx4mm as earth lead upto equipment by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 32x6mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified. Note : The cost of earth work, PCC pit, CI cover, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 40mm bore light grade GI pipe as protection to earth strip shall be deemed included in the unit rate for earthing.
M&L for fixing Flame proof lamp of LED FTL 1x20 Watt and IP 65 proteection complete with ground fixing & connection arrangment with suitable materials all as specified and directed. Make : SYSKO Cormpton Cat Part No EXTN1LT8-16/20/ Bajaj/Sudhir or equavalent
M&L for fixing Flame proof FLP/WP ON/Off rotary Swiches 10 Amps single pole 230 Volt
M&L for point wiring with and incl 1.5 sqmm (nominal area) PVC insulated multistranded copper conductor FRLS in and incl PVC insulated conduit not less then 20 mm dia with all accessories as required at site incl with its fittings and fixture such as ties, bends, elbows and juction boxes etc with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal ,One light point controlled by one way switch all as specified and directed
S & F sheet metal enclosure for DBs single door when MCBs to be used Single pole and neutral with 200 Amps rated bus bar 240 V, 2 Way
S&F inreplacement of MCB 16 Amps SPN 240 V, 50 Hz breaking capacity 10 KA
Supply and Fixing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor (multistranded), 1100 volts grade 6 sq mm 2 core connected with suitable cable gland and aluminium lugs of any size laid in trenches or passing through pipes including testing after laying, including taking up old UNSV cable complete specified and directed by Engineer-in-Charge.
Supply and Fixing of GI pipe 25mm bore light grade (ISI Marked) for cable protection along wall/pole/floor/road crossing etc complete including sealing of pipe ends with approved sealing compound including taking up old UNSV GI pipe complete all as specified and directed by Engineer-in-Charge.
M&L Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame including S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as per manufacturers instruction and as directed by E- in- charge.
Material and labour for 4 mm thick Pre painted gypsum building boards of size 595 x 595mm PVC laminated at back side of board insulation & acoustic purpose flat in ceiling fixed or laid / including powder coated GI snap grid of size 605mm x 605mm frame work using 36.50 x 23.50 x 1.5mm main Tee, 23.50 x 23.50 x 1.5mm cross Tee and 25x25x1.5mm angles for false ceiling with screws fixed to false ceiling including hangers 4 mm dia G.I (upto 1200mm length) adjusting level fixed to roof truss by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. NOTE: (The rate inclusive of scaffolding and necessary arrangements)
Demolition of brick work built in cement mortar incl all quions , arches ,pillar but excluding ashlars facing etc all as specified
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exc.6m mean radius built in CM 1:4 complete all as specified.
Rendering 15mm thick in cement mortar 1:4 finished even and smooth without using extra cement complete
M/L two coat of cement base paint on newly plastered/ unplastered surfaces over one coat of cement based primer on wall & including preparation complete all as specified and directed.
Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete.
S&F Factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S&F PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tub, supplying & fixing in opening as per specified and directed.
S&F 150mm Mild steel barrel tower bots, stove enameled black, with bright bolt and fixed.
S&F 250mm Aluminum alloy, anodised, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed.
S&F 100mm Butt hinges, medium weight, cold rolled mild steel and fixed
S&F 150mm Mild steel pressed handles, oval type, stove enameled black.
M/S New Builders Corporation
M/S AWDHESH KUMAR CO AND BROS
M/S MBS TRADING CO
M/S KUMAR AVINASH
P .BANERJEE AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .