| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹20.0 L+₹1.1 L (5.74%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹20.7 L+₹1.8 L (9.55%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹20.8 L+₹1.9 L (10.0%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance Rejected being other than lowest | |
| 5 | L5₹23.1 L+₹4.2 L (22.5%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
28 Oct 2021, 6:00 pmClosed
Maj Pramod Kumar Tripathi
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
Repair/Replacement of external electric supply, UG cables, LT panel, capacitor bank, street lights, lightning conductor, earth pits and painting of poles/panel of Amn Dump at Mil Stn Bhusawal under GE South Ahmednagar
2021_MES_478688_1
8822/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Bhusawal
Class E Cat b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (S) Ahmednagar
₹50,000
Yes
24 Nov 2021
30 Sept 2021
30 Oct 2021
30 Sept 2021
28 Oct 2021
14 Oct 2021
30 Sept 2021 - 7 Oct 2021
Amount
Excavation in trenches n, exc,1.5 m wide and n, exc,1.5 m in depth for laying of cable, foundation of pole/stay and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, levelling, watering and well ramming in layers n,exc.25cm thick all as specified and as directed.
Removing excaveted soil to a distance n,exc 50 m and depositing where directed at a level n,exc.1.5 m above the starting point complete all as specified and as directed.
M&L for PCC 1:3:6 , type C1, (using 20 mm graded stone aggregates) as in coping of pole including necessary form work, weathering, slightly rounded or chamfered angles & throating including demolition of existing damaged coping of poles complete all as specified and as directed.
S&F XLPE insulated, LT armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 sq mm, 3.5 core complete including taking out existing unserviceable cable along with brick protection all as specified and as directed.
All as per serial item No 5 but cross sectional area 95 sq mm, 3.5 core.
All as per serial item No 5 but cross sectional area 70 sq mm, 3.5 core.
All as per serial item No 5 but cross sectional area 50 sq mm, 3.5 core.
All as per serial item No 5 but cross sectional area 35 sq mm, 3.5 core.
All as per serial item No 5 but cross sectional area 25 sq mm, 3.5 core.
All as per serial item No 5 but cross sectional area 16 sq mm, 4 core.
All as per serial item No 5 but cross sectional area 16 sq mm, 2 core.
All as per serial item No 5 but cross sectional area 10 sq mm, 2 core.
All as per serial item No 5 but cross sectional area 6 sq mm, 2 core.
M&L for dry river sand in trenches for cushioning of underground cable including spreading, levelling, hand punning complete all as specified and as directed. Note:Punned thickness will be measured and paid.
Laying only bricks obtained from taking down under item Nos 5 to 14 here-in-before, laid dry in trenches for protection of underground cable, laid flat with length for brick perpendicular to length of cable complete all as specified and as directed.
Supply and laying well burnt, old size, sub class ‘B’ bricks locally available best quality, laid dry in trenches for protection of underground cable, laid flat with length for brick perpendicular to length of cable complete all as specified and as directed.
S&F in repairs, 50 mm bore dia GI pipe, light grade, laid in trenches / fixed to Pole / wall for cable protection complete all as specified and as directed.
S&F in repairs, 80 mm bore dia GI pipe, light grade, laid in trenches / fixed to Pole / wall for cable protection complete all as specified and as directed.
S&F in repairs, LED flood light fitting, 120 watt, 230V AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F in repairs, LED flood light fitting, 70 watt, 230V AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F in repairs, LED street light fitting, 100 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
S&F in repairs, LED street light fitting, 70 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
S&F in repairs, LED street light fitting, 60 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, braket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed.
S&F in repairs, LED post top lantern, 20 watt, 230 Volt AC with decorative post top 360 degree indirect light, IP 65 protection with impact and corrosion resistant complete all as specified and as directed.
S&F in repairs, garden dome light in spherical shape light fittings with 10 Watt LED bulb complete all as specified and as directed.
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI strip 32mm x 6mm by means of nut bolts, check nuts and washer upto main earth point, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 40 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point made out of 40mm x 6mm aluminium flat all as specified including testing on completion.
S&Fin repairs, earth continuity galvanised iron strip 32mm x 6mm fixed to pole or walls or both or burried in ground or drawn through pipe etc. as required for earthing complete all as specified and as directed
M&L for preparation of old painted steel or iron surfaces of any description over 10cm in width or girth and apply two coats of aluminium paint on electric poles and LT panels complete all as specified and as directed.
S&F in repairs, 1x36 watt, 4 pin PLL CFL type suitable for 1x36 watt rod light fittings complete all as specified and as directed.
S&F in repairs, FOS 18 watt, LED tube light 2G11-4 Pin base (PL-L lamp) retrofit, cool white 6500K, complete all as specified and as directed.
S&F in repairs, MD-XL double metalized paper ( Extra low loss) capacitor bank for 3 phase, 440 volts and 50 Hz system for permissible non leaner load 20 % of capacity 28/30 KVAr complete all as specified and as directed. Make : L&T/ Havells/C&S/ Cromption/ Schneider
S&F in repairs, overload protection relay, suitable for ML-4 FASD starter, MN-5, relay range 45-75A, direct mounting on MNX 45-80 and currenct capacity 160 A Max complete all as specified and as directed.
S&F in repairs, 3 pole power contactors, ML-4, IS/IEC-60947-4-1 and IEC-60947-4-1 type, 100A AC-1 and 70A-AC-3 type, 415V, 50 HZ complete all as specified and as directed.
S&F in repairs, 3 pole power contactors block ML-3, 40A, AC3, 415V, 50 HZ and 45Amps-AC-1 type and IS/IEC-60947-4-1 complete all as specified and as directed.
S&F in repairs MCCB, 415 Volts, 35 KA breaking capacity, 4 pole, 200 Amps complete with fixed thermal magnetic setting all as specified and as directed.
S&F in repairs, MCCB, 415 Volts, 35 KA breaking capacity, 4 pole, 250 Amps complete with fixed thermal magnetic setting all as specified and as directed.
S&F in repairs, MCCB, 415 Volts, 25 KA breaking capacity, 4 pole, 160 Amps complete with fixed thermal magnetic setting all as specified and as directed.
S&F in repairs, solar sensor timer, 240V for street light/high mast light (as per sample) complete all as specified and as directed.
S&F in repairs, procelain fuse unit 63 A complete all as specified and as directed.
S&F in repairs, on load change over switch 630A, 4 pole, 415 volt, 50 Hz with advance neutral in sheet steel enclosure (ISI marked) complete all as specified and as directed.
S&F in repairs, pole mounted FRP junction box (size 25cmx20cm), single door type, providing nut, bolt, cable glands, thimble including copper bus bar (2 Nos) of size 25x3 mm with MCB SP 16 Amps complete all as specified and as directed.
S&F in repairs, following parts of existing outdoor electric LT panel, including incoming & outgoing cable connections with suitable size of glands, lugs etc complete all as specified & as directed :- (a) Incoming MCCB 250 Amps, 4 poles 415Volt, 35 KA breaking capacity, thermal magnatic setting type -01 No (b) Outgoing MCCB 200 Amps, 3 poles, 415Volt, 35 KA breaking capacity -02 Nos (c) Digital ammeter rating upto 200A (d) Digital voltmeter of rating 500 Volt (e) RYB indicator switch
M&L for repair of existing earthing pit chamber as under : (a) Repair to damaged plaster in cement mortar 1:6, 10mm thick to match with existing. (b) Provision of RCC (1:2:4, type B1 using 20mm graded stone aggregates) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) with lugs 2 Nos and with 6 mm dia MS bar handle made to shape (c) Provision of funnel and wire mesh.
S&F in repairs, aluminium strip 25mm x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and as directed.
S&F in repairs, single pointed air termination copper rod, 12 mm dia, 300 mm long complete all as specified and as directed.
S&F in repairs, terminal box, made of phosporous bronze of size 75mm x 75mm x 25mm, drilled, screwed including 3 Nos, 8 mm dia, 25 gmm long hexaonal head screw all as specified and as directed.
Bhirud Electric Stores
BHAVIN INFRA
metro electrical services
SONU ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .