| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.9 L+₹40,431.25 (7.36%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹6.1 L+₹63,412.50 (11.5%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹8.1 L+₹2.6 L (47.9%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹8.5 L+₹3.0 L (53.8%)Rejected-Finance 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
22 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) AF MEMAURA
AGE(I) AF MEMAURA
REPAIR MAINT OF STREET SECURITY LIGHTS HIGH MAST LIGHTS BOLLARDS AND OTHER ALLIED WORKS AT AF STN MEMAURA
2025_MES_702730_1
8387/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
AGE(I) AF MEMAURA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE(I) AF MEMAURA
₹19,000
Yes
18 Jun 2025
27 Mar 2025
24 Apr 2025
27 Mar 2025
22 Apr 2025
10 Apr 2025
Amount
Dismantling and taking down carefully defective/non fuctional LED street light fittings from its existing position and refixing the same after repairing/replacement of unserviceable spare parts including re-assembling and testing complete all as specified and directed. (Note : Spare parts/component of street light and other light fitting shall be measured and paid seprately under respective items.)
Supply only LED street light driver suitable for 35 watt to 90 watt LED fittings including connection all as specified and directed.
Supply only LED street light driver suitable for 120/150 watt LED fittings including connection all as specified and directed.
Supply and fix in replacement LED street light fittings 35 watt complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection complete all as specified and directed.
Supply and fix in replacement LED street light fittings 60 watt complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection complete all as specified and directed.
Supply and fix in replacement LED flood light 50 watt 230 V, Warm White, AC outdoor type with thermal management in multiple optics and equipped with IP66 ,protection, with impact and corrosion resistant complete with driver and lamp. Make : Havells Cat Part No LHEECNP7PB6J050 or equvivalent in Crompton/Orient/Halonix/Bajaj as approved by AGE(I)
Supply and fix in replacement LED flood light 150 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 ,protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fix in replacement LED flood light 250 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 ,protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fix in replacement aluminium Decorative LED post top lantern 30 watt with polycarbonate/low glare optical design acrylic diffuser, 230 volts AC outdoor type, IP 65 with impact and corrosion resistant, complete with driver complete. Make : Surya Cat Part No ETPP SLE PT 30W or equvivalent in Crompton/Orient/Halonix/Bajaj as approved by AGE(I)
Supply and fixing in replacement LED strip lights, having IP65 rating, warm white (3000K) colour temp, complete all as specified and directed. Havells Cat Part No LHEHBQP5TN6F325 or equvivalent in Crompton/Orient/Halonix/Bajaj as approved by AGE(I)
S & F in replacement of 10 watt LED Bollard fitted with low glare diffuser, decorative, extruded aluminium housing, warm white, rated IP 65, with integrated driver etc including cable connections complete all as specified and as directed. Surya Cat Part No GLZ SLE BL 10W 600 NX E or equvivalent in Crompton/Orient/Halonix/Bajaj as approved by AGE(I)
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable/pipe etc. complete all as specified and as directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soft/loose soil, complete, all as specified and directed.
Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point, complete, all as specified and directed.
Material and labour for providing sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed.
Supplying & laying burnt clay bricks, sub class 'B', laid in trenches over cable protection complete all as specified and directed.
Taking up/down old U/S 6/10/16 sqmm 2/4 core XLPE insulated & armoured Al cable all as specified and directed.
Supply, laying and testing of LT cable 1100 volt grade XLPE insulated underground electric cable PVC bedded and sheathed steel wire/strip armoured aluminum stranded conductor of size 10 Sq mm 2 core complete all as specified and directed.
All as per item No - 18 but size 10 Sqmm 4 core
All as per item No - 18 but size 16 Sqmm 4 core
Relaying of existing serviceable underground cable of size 10 Sqmm to 16 Sqmm 2/4 Core obtained from item No 9 complete all as specified and as directed.
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
M&L for 40mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for 25mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in replacement street light bracket made out of GI tubing 40mm bore medium grade n.exc 1.5 metre long bent to shape as directed including suitable MS clamp of FI 50x6mm with MS bolts nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S & F in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 Nos of single pole MCB SP 0.5-3 Amp 'C' series inside the box and all specified and directed.
M&L painting of LT steel tubular pole with one coat of aluminium paint including brackets and synthetic enamel painting of Air Force blue (0.75M above foundation) and 02 Nos alternate layer of red & yellow colour self adhesive reflectic tape of 100MM width & writing pole number on black background with white lettering after scraping /cleaning well the existing rusted surface complete all as specified and directed.
M&L painting of LT octagonal pole bottom portion with two coat of Air Force blue (0.75M above foundation) over a coat of red oxide primer & 02 Nos alternate layer of red & yellow colour self adhesive reflectic tape of 100MM width & writing pole number on black background with white lettering after cleaning well the existing surface complete all as specified and directed.
S & F MCB single pole 240 volts, 'C' curve of rating 0.5-3 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
S & F MCB TPN 415 volts, 'C' curve of rating 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
S & F in replacement Contactor of rating 40 Amps 440 V, triple pole with auxiliary contacts for AC circuit, DIN mounting confirming to IS/IEC 60947-4-1 complete all as specified and directed. Make : L&T Cat No. CS94569 or equivalent in Schneider/Hager/Legrand as approved by AGE(I)
S & F Analog type timer, 220 V AC, curent rating 16 Amps, ON-OFF-ON type, Daily programmable, DIN rail mounting and testing on completion complete all as specified and directed. Make : Schneider Cat No.CCT15365 or equivalent in L&T/Hager/Legrand as approved by AGE(I)
Material and labour in replacement 1.5 sqmm three core copper PVC insulated sheathed cable drawing into inside the Pole / bracket of street light including making hole of 15 mm dia on bottom & top complete all as specified and directed. Make : Havells Cat Part No WHMFDSKG31X5 or equivalent in Polycab/Anchor/Grandlay
M&L for earthing complete with galvanized steel pipe electrode 40 mm bore, medium grade 2.50 meters length, buried in ground vertically to a depth n.less than 3.75 mtr below normal ground level and connected with GI earthing wire 4 mm dia by means of bolts, nuts and washers made of galavanised iron and steel earth wire protected by 15 mm bore light grade GI pipe incl PCC work as per sketch No - 2 of SSR Part -I (2009) pit cover slab of size 300x300x50 mm with handle as shown in drawing funnel, wire mesh 20 mm dia GI pipe medium grade for watering, charcoal and slat in alternate layers incl necessary earth work and excavation in soft/loose soil and removal etc incl testing complete all as specified and directed including tesing on completion.
Excavation in post holes (or similar holes ) each not exceeding 0.5 CUM, getting out, returning, filling in and ramming earth or borken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M & L for PCC (1:3:6) type C2 (using 40mm graded crusehd stone aggregate ) as in foundation of pole including necessary form work complete all as specified and directed.
M & L Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:4 all as specified and as directed.
M & L for 15 mm thick rendering in cement morter (1:4) on fair face of brick or concrete surface finished even and fair all as specified and as directed.
S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of gate lights and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
GIAN ENGINEERS (BID ID -3286133)
M/S KAUSHIK CONSTRUCTION (BID ID -3286092)
Joy Dey Enterprises (BID ID -3282347)
Industrial Traders (BID ID -3280004)
VIDYA TRADERS (BID ID -3281910)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .