| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-Finance | L1 | Accepted-Finance Accepted | |
| 2 | L2₹2.7 L+₹3,350 (1.25%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹2.7 L+₹5,000 (1.87%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹2.8 L+₹14,020 (5.24%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹3.1 L+₹38,000 (14.2%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
Closing Date
20 Jan 2021, 12:00 pmClosed
GE Faizabad
GE Faizabad
JOB WORK FOR IMPROVEMENT OF COOLING SYSTEM FOR POWER TRANSFORMER AT 33/11 KV MRS AT FAIZABAD.
2021_MES_412437_1
3016/Q/08/E3
Limited
Job Works
Works
30 days
GE Faizabad
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
4 Feb 2021
14 Jan 2021
21 Jan 2021
14 Jan 2021
20 Jan 2021
14 Jan 2021
(i) M & L for installing forced cooling system of power transformer with 2 Nos 450 mm exhaust fan, metal body (Make- Crompton Greaves/Bajaj/Usha) heavy duty mounted on 50 x 50 x 6 mm equal angle iron 21.96 RM and top and side portion covered with 3 mm thick steel sheet including provn of barbed wire 2.24 mm dia 2 strand (9.5 RM) and grounting to soil upto 0.6 mtr with PCC 1:3:6 (40 mm graded aggregate type C-2 all as specified and directed by Engr-in-Charge- Each Job - 02 nos. (ii) M & L for installing forced cooling system of power transformer with 3 Nos 450 mm exhaust fan, metal body (Make- Crompton Greaves/Bajaj/Usha) heavy duty mounted on 50 x 50 x 6 mm equal angle iron 21.96 RM and top and side portion covered with 3 mm thick steel sheet including provn of barbed wire 2.24 mm dia 2 strand (9.5 RM) and grounting to soil upto 0.6 mtr with PCC 1:3:6 (40 mm graded aggregate type C-2 all as specified and directed by Engr-in-Charge - Each Job - 02. (iii) Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge - CUM - 23. (iv) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed by Engr-in-Charge - CUM - 12.5. (v) Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge - CUM - 10.5 (vi) M & L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured & Paid- CUM (vii) Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge - Per 1000 Nos - 0.739 (viii) Supplying, laying, commissioning & testing LT underground cable 10 sqmm 2 core 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type complete all as specified and directed by Engr-in-Charge - RM - 120 (ix) S&F in replacement of PVC insulated and FR PVC multicore round sheathed copper conductor (flexible) industrial cable 4 Sq mm 4 core, 1100 volt confirming to IS - 694 complete all as specified and directed by Engr-in-Charge. Make- Havells - RM - 90 (x) S&F in replacement PVC insulated and FR PVC multicore round sheathed copper conductor (flexible) industrial cable 2.5 Sq mm 12 core, 1100 volt confirming to IS - 694 complete all as specified and directed by Engr-in-Charge. Make- Havells - RM - 110 (xi) S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 8 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed. Make - Havells - Each - 2 (xii) S&F MCB single pole and neutral ISI marked `C' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 32 Amps 10 KA breaking capacityas in repair etc all as specified and directed. Make - Havells - Each - 2 (xiii) S&F MCB single pole ISI marked ISI Marked `C' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 6-32 Amp breaking capacity 10 KA as in repair etc all as specified and directed. Make - Havells.
Super Automobiles
NAMAMI TRADERS
SHUBHAM CONTRACTOR
PANDEY ENTERPRISES
HARSH ASSOCIETES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_460623.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .