Superintending Engineer (EWCL)
Type-IV/3, Transmission Staff Colony Dewa Road, Chinhat Lucknow
Increasing capacity of 33/11 KV S/S Madhawganj 1x10 Plus 1x5 to 2x10 MVA under EDD-I, Hardoi under the Nagar Nikay
2023_MVVNL_781293_1
35/EWCL/2022-23
Open Tender
Electrical Works
Fixed-rate
90 days
33/11 KV S/S Madhawganj under EDD-I
As per tender documents
2 documents required · 2 mandatory
₹1,180
A/c No. 0758002100009592, IFSC PUNB0586800
₹9,700
1 Apr 2023
4 Mar 2023
28 Mar 2023
4 Mar 2023
28 Mar 2023
4 Mar 2023
Amount
Safe loading, carriage and unloading & proper stacking of following store materials from any Electy. Store of Lucknow Zone to 33/11 KV S/S Madhawganj, Hardoi site (work site).
Cost of 33 KV Bus Isolator
Cost of Post Insulator
200/100/5 AMP, 350 MVA Outgoing
11 KV 3x300 SQ MM XLPE
11 KV 3x120 SQ MM XLPE
Cost of ACSR Panther Conductor
Rail Pcs of 90 Lbs 3.46M long 2 No. Pcs 6.92M @ 44.61 Kg./M
MS Angle 40x40x5 mm (3.0 Kg/Mtr)
11 KV 3x300 SQ MM XLPE Cable Outdoor
11 KV 3x300 SQ MM XLPE Cable Indoor
Single Core PVC Cable, 1x400 sq.mm.
11 KV 3x120 SQ MM XLPE Cable Outdoor
11 KV 3x120 SQ MM XLPE Cable Indoor
Earthing for power T/F by way of boaring and lowering of 40mm dia, 2.5 mm thick GI Pipe from ground upto the water level (minimum 30 Mtr. deep) as per standard practice as per REC Drg. No.-41
Earthing of 11 KV, 33 KV Switchgears & Equipment: Earthing of 11 KV, 33 KV Switchgears equpiment by lowaring and boring of Chemical Earting outsite of switchyard and connecting through G.I. Strip 50x6mm with indoor/outdoor equipments. (All the matrial provided by the contrartor)
Repairing and extension of Power Transformer Plinth for 10 MVA T/F.
Shifting carefully & installation safely 11KV O/G switchgears from outside the switchgear room placing and fixing of switchgear on foundation providing G.I. Bolt & Nuts of proper size in proper position and alignment. This includes checking, complete work with mounting of P.T. on incoming S/G with proper testing, connetion of earthing & commissioning of switchgears.
Fixing and making Bus Bar connections in between all switchgears after cleaning and tapping with H.T. Tape, empire tape and PVC tape properly, providing and fixing of 6 mm thick Bakelite separators and plugging of all opening & holes with plastic compound complete work as per satisfaction of site incharge.
Installation of Isolators: Dismantling and replacment of old amd damged existing 33 KV Isolators by new 33 KV bus isolator and assembling and installation of line/ bus isolator on the isolator structure adjusting of opening mechanis in proper alignment so as to ensure smooth operation of the same. In case of line isolator proper operation of earth links shall also be ensured. The work includes fabrication & proper connection with earthmat/earthing by G.I. earth strip 50x6mm proper fixing if required (All decentralised materials to be provided by Contractor).
Installation of P.I. : Assembling, installation & mounting of Post insulator on the P.I. Structure/complete with making earth connections (separate) with GI Strip 50x6mm. The work includes fabrication for fixing if required. (All decentralised materials to be provided by Contractor).
HT Cable Laying : Laying & dressing of 11KV 3x300 Sq.mm XLPE cable (single circuit) from 10 MVA T/F to 11KV incoming Switchgear by excavation of earth in the trench 450 mm wide, 900mm deep providing 150mm fine sand cushion below and above the cable. The cable shall be duly protected by bricks, sand & stone slab. The work includes supplying of fine sand, bricks and stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable.
HT Cable Laying : Laying & dressing of 11KV 3x120 Sq.mm XLPE cable (single circuit) from 11KV outgoing Switchgear to outgoing duble pole feeder by excavation of earth in the trench 450 mm wide, 900mm deep providing 150mm fine sand cushion below and above the cable. The cable shall be duly protected by bricks, sand & stone slab. The work includes supplying of fine sand, bricks and stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable.
Hoisting of 11KV Cable to 11 KV switchgear & 33/11KV T/F.
Hoisting of 11KV Cable with 100 mm dia 3 Mtr. long GI Pipe on the feeder cable before mounting the cable on the double pole, lifting, mounting and clamping of 11KV feeder cable boxes on the feeder double pole structure and making connection including supply of cable mounting clamps. The work includes the sealing of GI Pipes, lower end of the pipe is to be buried into the earth by about one foot. (All the material provided by the contractor).
Painting of all structures and equipments.
Fixing of Single Core PVC Cable, 1x400 sq.mm. & fixing between Transformer incoming 3x300 Sq.mm XLPE Cable and Transformer 11 KV/LV Side Bushing connector for reducing of tension at LV Side Bushing.
SINLESS ELECRICAL CO. PVT. LTD.
A.A. ENGINEERING CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .