Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
18 Mar 2022, 2:00 pmClosed
SE PWD Silchar Building Circle Silchar
SE PWD Silchar Building Circle Silchar
Civil Sanitary WSS and MGPS works
2022_PWBNH_24726_1
SBC/CS/2021-22/12/170/Gr.-II
Open Tender
Civil Works - Building
Item Rate
360 days
Karimganj CIvil Hospital KArimganj
AS per NIT
5 documents required · 5 mandatory
₹3,000
Assam State Road Board Maintenance (Roads) Fund
₹2.6 L
Yes
SE PWD Silchar Building Circle Silchar
24 Jun 2022
15 Mar 2022
19 Mar 2022
15 Mar 2022
18 Mar 2022
15 Mar 2022
15 Mar 2022 - 18 Mar 2022
16 Mar 2022
Amount
By mechnical transport including loading, unloading & stacking Lime,moorum,Building rubbish
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete
Supplying and filling in plinth with local sand under floors including watering, ramming consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane Emulsifiable concentrate of 20%.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:4 (1 cement : 4 coarse sand)
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, posts and Struts
Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M25 grade with minimum cement
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in foundation & plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
Extra for providing and placing in position 2 Nos. 6 mm dia MS bars at every third course of half brick masonry (with FPS bricks)
Brick edgeing 7cm wide 11.4cm deep to plinth protection with brick of class desiganition 75 including grouting with cement mortar 1:4 ( 1 cement: 4 fine sand )
Providing and fixing precoated galvanised iron profile sheetrs ( size ,sahpe and pitch of corrugation as approved by engineers-in charge ) 0.50mm ( +0.05% ) total coated thickness with zinc coating 120 grams per sqm as per IS 277 , in 240 mpa steel grade,5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns . Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied insingle length upto 12 meter or as desired by engineer-in charge .The sheet should be fixed using self drilling /self tapping screws of size ( 5.5 x 55 mm ) with EPDM seal ,complete upto any pitch in horizontal/vertical or curved surfaces. excluding the cost of purlins, rafter and truss and including cutting to size and shape wherever required
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
12mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
18 mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including priming coat with cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with "Silicone additives of required shade. New work (two or more coats applied @1.43 ltr/10 sqm over and including base coat of water proofing cement paint applied @2.20kg/10sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supply of surface/pendant mounted totally enclosed linear luminaire(Ingress protection IP-65),WI0831208G1(Wipro or equivalent make 1x20W LED Tube T8.
Supplying of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, required complete and as directed by the Department [ without regulator]. 1200 mm sweep ceiling fan (Make- HAVELLS : Model Name :ES-40, 3-star
Supplying of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department. Heavy Duty 600 mm sweep, 900 RPM ,Single phase (Make- HAVELLS : Model Name :Turbo force TP/SP
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 510 mm sweep
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supply, installation ,testing and commissionig of Distribution Panel board with provision of Incomer MCCB, 400Amps : 1no. , MCCB, 250 Amps: 1No. , MCCB, 200Amps: 1no. and MCB , 40 Amps, 10 KA: 2 nos. made out with 1.6 mm CRCAsheet steel, 3-phase, suitable for floormounted , user front facia, powder coated for long lasting finish, cubical type,suitable cable entry provision andincluding of all necessary electricalprotections including , Aluminum Bus bar etc.
Supply, installation ,testing and commissionig of 400Amps AMF BY PASS Panel Board made out with 1.6 mm CRCAsheet steel, 3-phase, suitable for floormounted , user front facia, powder coated for long lasting finish, cubical type,suitable cable entry provision andincluding of all necessary electricalprotections including , Aluminum Bus bar etc.
Supply, installation ,testing and commissionig of Distribution Panel board with provision of Incomer MCCB ,125 Amps: 1 no, 40Amps MCCB: 2 nos. and MCB, 40A:2 nos., made out with 1.6 mm CRCAsheet steel, 3-phase, suitable for floormounted , user front facia, powder coated for long lasting finish, cubical type,suitable cable entry provision andincluding of all necessary electricalprotections including , Aluminum Bus bar etc.
Supply, installation ,testing and commissionig of Transformer Incoming Panel board with provision of Incomer MCCB , 400Amps, made out with 1.6mm CRCA sheet steel, 3-phase, suitable for floor mounted , user front facia, powder coated for long lasting finish, cubical type, suitable cable entry provision and including of all necessary electrical protections including , Aluminum Bus bar etc. of Protection.
Supplying, installing on wall, testing and commissioning of following capacity rising mains made of 1.6mm thick sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 Nos aluminium bus bars in convenient sections and suitable for 415 volts, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pads including jointing, and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TEC 439) 200 amps (S.C. rating for 1 sec - 15 KA)
Supplying, installing on wall, testing and commissioning of following capacity rising mains made of 1.6mm thick sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 Nos aluminium bus bars in convenient sections and suitable for 415 volts, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pads including jointing, and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TEC 439) 400 amps (S.C. rating for 1 sec - 25 KA)
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp, 30KA, FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 30KA, FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 Amp, 36KA, FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 Amp, 36KA, FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 Amp, 50KA, FPMCCB
Supplying including installation, testing and commissioning of 250 KVA Automatic Voltage regulator with input Voltage Range 300 Volt to 460 Volt AC and output voltage 415 Volt, servo type,oil cooling, copper wound coil outdoor type, IP-43(Degree of protection). 250KVA. Automatic Voltage regulator
Supply and installation of 2 KVA On-Line UPS System (Orion or equivalent make as approved by the Deptt.) with PWM-IGBT technologyc230V AC Input (160V – 280V A 1 Ph input- 1 Ph outputWith Isolation Transformer 1.6KW output with 0.8 output PF 60 min backup using SMF battery.
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KV . Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer or equivalent alternator. 250 KVA Genset with AMF Panel .
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
Supplying of following sizes XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 650/1100 V grade conforming to IS 7098 (Part - I) / 1988 with amendment up to date etc as required. 3 ½ X 300 sq.mm
Supplying Power/Control Copper Cables, Solid Copper conductor upto 6sqmm balance Stranded, XLPE Insulated, cores laid up, PVC tape innersheathed for Multicore Cables, Unarmoured/Armour (Glavanised wire for cables up to 10 x 1.5 sqmm, 8 x 2.5 sqmm, 2 x 10 sqmm, 3 x 10 sqmm, 4 x 6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 1.5 SQ mm ,10 core ,Copper armoured powered/control cable 2xwy/2XFY.
Supplying of following sizes XLPE insulated,insulation screening with extruded semi conducting compound in combination with copper tape cores laid up inner sheath of PVC tape,galvanised flat steel strip armoured and overall PVC sheathed cable confirming to IS7098(Part-II) 1985 with latest amendments . 3 core 240 sq.mm, 11 KV grade
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq.mm and upto 400 sq.mm
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 300 sq. mm
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre
Supplying of SP-66, 12 Mtrs. Length , Hot Dip Galvonized , Steel Tubuler pole confirming to IS: 2713,
Supplying and erection of 15 A aerial fuse complete as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 50 mm dia
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. i) 250 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Payment to be made to APDCL Authority for load security
Payment to be made to APDCL Authority.supervision including trivector meter,CT/PT
First Fuel Filling for DG set
Shifting of 250 KVA KOEL and 40 KVA Mahindra DG set from One place to New DG set Foundation .
Supply and installation,Testing & Commissioning of Terminal Units(Gas Outlets)with Probes/Adaptes as per ISO 9001:2015 & 3 digit CE marked company.The outlet will be equiped with primary and a secondery check valvewith suitable pressure for (O2 Cleared for medical gas and pressure tested,inlet pipe can be swiveled 360 degree for ease of installation as per spesified and directed)
Supply and installation,Testing & Commissioning of O2 flow meter as per ISO 9001:2015 & 3 digit CE marked company made with chrome plated brass bodey,graduated flow tube and cover made of polycarbonate & unbreakable. Adjustable flow by needle valve(know) with micrometric regulation. Humidifier bottle is made of unbreakable polycarbonatematerial and is autoclavable
Supply fitting and fixing of Copper Pipes as per Medical Grade: Llyod Certified 12 mm od X 0.7mm thickness
Supply fitting and fixing of Copper Pipes as per Medical Grade: Llyod Certified 15mm od X 0.9mm thickness
Supply fitting and fixing of Copper Pipes as per Medical Grade: Llyod Certified 22mm od X9mm thickness
Supply fitting and fixing of Copper Pipes as per Medical Grade: Llyod Certified 28mmX.9mm thickness
Supply and installation,Testing & Commissioning of isolation valves with brass body with nickel plate valve operating handle suitable for 12mm Od copper pipe to 42mm Od copper pipes with brass adapter as per standard spesification & as per ISO 9001:2015 & 3 digit CE marked company and sirevted for the following isolations. 15mm od X 0.9mm thickness
Supply and installation,Testing & Commissioning of isolation valves with brass body with nickel plate valve operating handle suitable for 12mm Od copper pipe to 42mm Od copper pipes with brass adapter as per standard spesification & as per ISO 9001:2015 & 3 digit CE marked company and sirevted for the following isolations. 22mm od X 0.9mm thickness
Supply and installation,Testing & Commissioning of isolation valves with brass body with nickel plate valve operating handle suitable for 12mm Od copper pipe to 42mm Od copper pipes with brass adapter as per standard spesification & as per ISO 9001:2015 & 3 digit CE marked company and sirevted for the following isolations. 28mmX 0.9mm thickness
Supply and installation,Testing & Commissioning of Oxygen Manifold Extendable type12+12 size compatible as per ISO 9001:2015 & 3 digit CE marked company with middle frame with chain of individual Cylinder and high pressure annealed copper tail pipe with 1 end having brass adaptor and other end suitable for manifold non return valve and manifold will have 20 brass non return valve for individual Oxygen cylinder , middle frame with cercumferential MS felt duley powdercoated all as spesified and as directed
Supply and installation,Testing & Commissioning of Automatic gas control panel for O2 as per ISO 9001:2015 & 3 digit CE marked company., two stages of pressure regulators will be provided in the control cabinet for pressure regulation . One delivery pressure regulator .
Supply and installation,Testing & Commissioning of 5+5 Cylinder Emergency Oxygen Maniflold as per ISO 9001:2015 & 3 digit CE marked company. with two stage high flow rate regulator With NRV for every cylinder and copper tail pipe with top and middle frame for Oxygen
MREEGEN SAHARIAH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .