Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | ₹15.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹16.4 L+₹43,773.31 (2.75%)Rejected-AOC SUMATEE BHAWAN GUWAHATI AIRPORT NEAR BORJHAR TELEPHONE EXCHANGE GUWAHATI 781015 ASSAM | KAMRUP METRO | ASSAM | 781015 | ₹16.4 L+₹43,773.31 (2.75%) | L2 | Rejected-AOC AOC |
Tender Value
Refer Docs
EMD Value
₹29,100
Closing Date
7 Jun 2024, 6:00 pmClosed
CWE AF Borjhar
HQ CWE (AF) Borjhar Military Engineer Services PO - Borjhar Airport, Guwahati (Assam) - 781015
PROVN OF ELECTRO STATIC DISCHARGE TILING IN LAB OF 2409 SQN UNDER GE AF BORJHAR
2024_MES_653440_1
CWE(AF)/BOR/TOKEN 04 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Borjhar
As per Tender document
8 documents required · 8 mandatory
₹500
GE (AF) Borjhar
₹29,100
Yes
4 Sept 2024
10 May 2024
10 Jun 2024
10 May 2024
7 Jun 2024
24 May 2024
Amount
Supply, installation, commissioning and testing of double copper wound transformer step down, oil immersed, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage within limit, all as per IS 1180 (Part-I 2014) all as per amendment No. 4 of Mach 2023, level-I of capacity 160 KVA complete. Make- Andrew Yule/Bharat Bijlee/Voltamp/ABB/ITE The Transformer shall have following specification complete all as specified. (i) No Load Voltage ratio - 11000/433 Volt, (ii) Tapping on HV % - + 7.5, + 5, + 2.5 (iii) 3 Phase and frequency - Phase and 50 Hz. (iv) Vector group - Dyn 11 (v) Connection - Delta star, (vi) Type of cooling - ONAN (ix) Impedance - 4.5 %, (x) Temp rise in Oil - 35 Deg C (xi) Type - Out door, (xii) Temp rise in winding - 40 Deg CTerminal arrangement HV Side - Three Nos Weather proof LV side - Quad furcating cable Box with copper bus bar terminal suitable to connect PVC cable. One additional neutral bushing terminal for earthing purpose. Fittings:- (i) Externally hand operated off circuit Tap switch with position indicator and locking device (ii) Conservator with oil gauge, filling hole, with plug and hole with lug (iii) undercarriage with four plain roller -, (iv) Oil filling hole cum air release plug - one no (v) Drain valve cum sampling valve - One No, (vi) Filter valve with plug - One No (vii) Rating plate & Diagram plate - One , (viii) Lifting lugs For transformer - Two No, (ix) Lifting lugs Forlids - Two No, (x) Earthing terminals-Two no (xi) Thermometer pocket- One, (xii) Silica gel breather - One, (xiii) Explosion vent - One, (xiv) Inspection cover- One (xv) 6" Dial type thermometer with alarm & trip & max temp indicator- One
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft / loose soil complete all as specified and directed
Returning, filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the starting point , complete all as specified and as directed.
Supply and spreading dry sand of approved quality for cushioning of UG cable laid in trenches 8 cm deep before laying the cable and 15 cm thick after laying & streching the cable complete all as specified and directed. (NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid for).
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
Supply and fix GI pipe light grade 80 mm bore for cable protection including all fittings laid in trenches or fixed on pole with suitable clamps complete all as specified and directed.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable of size 150 sqmm 3.5 core (heavy duty), aluminium stranded conductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed.
M&L for cable jointing kit for 1.1KV grade for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core PVC/XLPE armoured aluminium conductor cable of size 70-150 sqmm complete all as specified and as directed. Make: Raychem/3M/M-Seal
M&L for providing hardcore of broken stone or boulders of gauge not exc 63 mm deposited,spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface all as specified.
M&L for cement concrete in foundations,filling and mass concrete Type C2 1:3:6, 40 mm graded aggregate all as specified and directed by Engr-in-charge.
M&L Providing PCC 1:4:8 type D2 using 40 mm grade stone aggregate 100 mm thick as in sub base of floors all as specified and directed by Engr-in-charge.
M&L for machine cut kota stone slab flooring 20-25 mm thick over 20 mm thick screed bed in CM(1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed.
M&L rendering 10 mm thick in CM 1:6 on fair faces of bricks or concrete surfaces all as specified and directed.
Supply and fix Electrical Resistance Anti Static Tiles of size 600x600 of colour Blue Dk/L having Dimension & Surface quality as per IS 13630 Part 1, minimum Surface electrical resistance should be 10^3 ohm/square to 10^6 ohm/square (for Conductive) and 10^6 ohm/square to 10^9 ohm/square (for Dissipative) , breaking capacity greater than 38 N/m^2 with 9 mm thick polished vitrified tiles ,area of each tiles not exceeding 0.36 sqmm in floor set and jointed in net cement slurry@ 3 kg per sqmm and pointed in coloured cement to match the shade of the tiles over and incl 20 mm screed beding CM(1:6) complete all as directed.
M&L for Earthing complete with copper earth plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 20×3mm copper strip as earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. (copper strip upto 7.5m including testing consider in this item). .
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw.
M&L for Copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors/ burried in ground along the periphery of the each tiles for elctrostatic grounting and down conductors above ground
Ms Sukumar Talukdar and Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .