Repairing and maintenance of the water supply system and misc. other repairing works in Ved nagar staff quarter blocks at Ujjain in Ujjain BA 3rd call
2024_BSNL_219857_1
NIT NO 32/EE/DIV/IND/2024-25
Open Tender
Civil Works
Item Rate
30 days
UJJAIN
Please refer Tender documents.
2 documents required · 2 mandatory
₹177
Accounts Officer Cash Oo GMTD BA Ujjain
₹1,593
21 Jan 2025
17 Dec 2024
28 Dec 2024
17 Dec 2024
26 Dec 2024
17 Dec 2024
Amount
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for :
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Grading roof for water proofing treatment with
Cement mortar 1:3 (1 cement : 3 coarse sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete :
New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade.
Old work (one or more coats)
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Repairing of damaged open GI pipeline by cutting off the damaged portion of the line and providing and fixing the new pipe, nipple, socket and union etc. to make good the pipeline including testing of joints amd making good the walls, floors etc. all complete as per direction of Engineer-in-charge.
Repairing of damaged underground existing GI pipeline by excavating the surrondings up to the required depth for proper working on the existing pipeline and repairing the same by cutting off the damaged portion of the line, replacing the same with new one including fittings such as socket, nipple required for proper fitting of the same but excluding the cost of unions and GI/CPVC pipe required and then checking the same with running water through the line and then refilling the same etc. all complete as per the direction of Engineer-in-charge.
Repairing of the damaged hidden under wall GI pipeline by cutting chases up to required length and depth by cutting off the damaged portion of the pipeline, replacing the same with new one including providing GI/CPVC pipe, sockets, nipples and union etc. required to make good the line, testing of the same and making good the walls and floors etc. all complete as per the direction of Engineer-in-charge.
Repairing of steel glazed windows at all levels including bringing in the welding machine at site and providing hinges, pivots and section of windows etc. whatever required and making the same good functional etc. all complete as per the direction of Engineer-in-charge. Steel members and glazing fixed are to be paid seperately in respective items.
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all complete as per the direction of Engineer-in-charge.
Providing and fixing fly proof SS wire mesh jali in existing steel section windows with necessary fillets and nuts if required all complete as per direction of E-in-C.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10 litre capacity - White
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
Flat back wash basin of size 550x400 mm.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
32 mm dia
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms.
Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
15 mm nominal outer dia. Pipes.
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia. Pipes.
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work
25 mm nominal outer dia. Pipes.
32 mm nominal outer dia. Pipes.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
32 mm nominal bore.
40 mm nominal bore
Providing and fixing PTMT bib cock of approved quality and colour.
15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour .
15mm nominal bore, 107 mm long. Weighing not less than 110 gms.
Providing and fixing PTMT grating of approved quality and colour.
Circular type.
100 mm nominal dia.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.
15 mm nominal bore, 105 mm long. Weighing not less than 138 gms.
Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms.
Providing and fixing PTMT swivelling shower, 15mm nominal bore. Weighing not less than 40 gms.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
15 mm nominal bore with 45 cm length.
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter.
Note :- (1) The elevational area of the scaffolding shall be measured for payment purpose.
(2) The payment will be made once only for execution of all items for such works.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .