Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.5 LAccepted-Finance 0 DHANA TEJA BARARI DHANA TEJA MATHURA MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | L1 | Accepted-Finance L1 | |
| 2 | L2₹83.1 L+₹11.6 L (16.3%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Eligible for Part I |
Tender Value
₹71.5 L
EMD Value
₹71,500
Closing Date
6 Jan 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
EDC, Ayodhya
110 H(F)(W)/2024-25
2024_MVVNL_984775_1
110 H(F)(W)/2024-25
Open Tender
Electrical Works
Item Wise
90 days
Ayodhya
As Per Tender Specification
2 documents required · 2 mandatory
₹3,540
Superintending Engineer, EDC
₹71,500
22 Jan 2025
21 Dec 2024
7 Jan 2025
21 Dec 2024
6 Jan 2025
21 Dec 2024
Amount
Part - A ( Material) Following Material Supplied by the Contractor:-
Supply of Gland 63 mm
Supply of Gland 50 mm
Supply of Gland 25 mm
Supply of Gland 28 mm
Supply of Pre Cost of Pannel A & B Type Base
Supply of Pre Cost of Pannel C Type Base
G.I. Pipe 6'' dia
Supply of Laying of HDPE Pipe for Suitable Size
Copper L Piece 50x225x10 mm
Aluminum Lug
Aluminum Lug long Barrel
Aluminum Lug for 250 KVA Transformer
Holding Clamp for TOP Channel, TPMO Set & Fuse wire Set with Nut & Bolt
Nut & Bolt
Stone Pad
I Hook
Holding Clamp with Nut and Bolt
Three Phase D-Box Clamp
V Type Cross Arm 11 KV
Cross Arm Holding Clamp with Nut & Bolt
Supply of 800 Amp. MCB
Supply of 250 Amp. MCB
Supply of 100 Amp. MCB
Carriage including loading,unloading & Proper stacking of following Stock materials from store/departmental store to Dump site distance 0 to 30 Kms. (distance approx)
S.T. Pole 11 Mtr. long
11 KV XLPE Cable 3x70 sqmm
11 KV XLPE Cable 3x120 sqmm
11 KV XLPE Cable 3x185 sqmm
11 KV Out door Cable Jointing kit 3x70
11 KV Out door Cable Jointing kit 3x120
11 KV Out door Cable Jointing kit 3x185
11 KV Staight Through Cable Jointing kit 3x120
L.T. XLPE Cable 1x240 sqmm
L.T. XLPE Cable 1x400 sqmm
L.T. XLPE Cable 3.5x150 sqmm
L.T. XLPE Cable 3.5x240 sqmm
L.T. XLPE Cable 3.5x400 sqmm
AB Cable (3x120+1x95+1x16) sqmmq
Three Phase Distribution Box
ACSR Weasel Conductor
ACSR Dog Conductor
T/F 250 KVA
T/F 400 KVA
A Type Pannel
B Type Pannel
C Type Pannel
Other matching Materials
Dragging of ST/PCC Pole from dump site to pit site
Fabrication and Errection of Single Pole Support on ST/PCC Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Fabrication and Errection of Double Pole Support on ST/PCC Pole Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPo Norms. (Cost of clamps borne by contractor)
Stringing, Sagging, Binding and jumpering of ACSR Weasel Conductor as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of ACSR Dog Conductor as per RESSPO Norms
Stringing, Sagging, Binding and jumpering of AB Cable (3x120+1x95+1x16) sqmmq Conductor as per RESSPO Norms
Earthing of C Type Pannel
Installation of A Type Pannel
Installation of B Type Pannel
Installation of C Type Pannel
Mounting of 250 KVA Transformer as per RESSPO Norms.
Mounting of 400 KVA Transformer as per RESSPO Norms.
Laying of underground 11 KV 3x70 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Hanaging, Hosting & clamping of G.I. Pipe, channel, nut & Bolt 3x70 mm2 XLPE 11 KV cable as per RESSPO Norms (cost of all accessories will be borne by contractor)
Laying of underground 11 KV 3x120 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Hanaging, Hosting & clamping of G.I. Pipe, channel, nut & Bolt 3x120 mm2 XLPE 11 KV cable as per RESSPO Norms (cost of all accessories will be borne by contractor)
Laying of underground 11 KV 3x185 sq mm XLPE Cable in Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable)
Laying of L.T. XLPE Cable 3.5x150 sqmm
Laying of L.T. XLPE Cable 3.5x240 sqmm
Laying of L.T. XLPE Cable 3.5x400 sqmm
Installation of Heat Shrinkable Type cable jointing kits Outdoor end Termination suitable for 11 KV XLPE cable 3x70/120/185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Installation of Heat Shrinkable Type cable jointing kits Staight Through end Termination suitable for 11 KV XLPE cable 3x185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.)
Construction of Transformer Plinth size 2x2x1.5 including excavation of foundation, base concreting of 1:6:12 (Cement mortar of Ratio 1:4 foundation, CC in 1:4:8 ratio (Cement fine sand and brick ballast ) and RCC work with ratio 1:2:4 Cement, Coarse sand and Stone Grit of 20 mm gause as per RESSPO norms
Fencing of Transformer Plinth with the help of wire mesh/Barbed wire after grouting proper size of angle as per RESSPO Norms. Inclusive of all material such as Wiremesh/Barbed Wire, Angle Flats, Nut Bolts etc.
Earthing by way of boring and lowering of "B" class G.I. pipe 50 mm dia 20 mtr. Long from ground upto the water lavel it will be connected to the G.S. Strip for T/F nutral connection the earth strip will be welded to the G.I. pipe the work also included top cap and clamps for pouring water the cost of all material will all labour and T n P etc. complete in all respect . (all the material will be supplied by the contractor.)
Chemical Type Earthing for A& B Pannel
Connection of L.T. XLPE Cable Different Size & Different Places
Repairing of Pannel Door, lock etc.
Rect. Back old and used 100 KVA T/F
M/s Shukla Enterprises (BID ID -4830505)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .