Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹9.9 L+₹1.1 L (12.5%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹10.4 L+₹1.6 L (18.3%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹10.6 L+₹1.7 L (19.6%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹10.7 L+₹1.9 L (21.1%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
16 Feb 2024, 5:00 pmClosed
AGE I AF CHIMNEY HILLS BANGALORE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
MAINT AND REPAIR OF EXTERNAL WATER SUPPLY SYSTEM AND CONNECTED ITEMS AT 58 SU AF STATION CHIMNEY HILLS
2023_MES_602283_2
8631/E8
Open Tender
Civil Works
Item Rate
240 days
AGE I AF CHIMNEY HILLS BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
AGE I AF CHIMNEY HILLS BANGALOR
₹18,000
Yes
1 Apr 2024
30 Jan 2024
17 Feb 2024
31 Jan 2024
16 Feb 2024
9 Feb 2024
31 Jan 2024 - 6 Feb 2024
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/repair of water Pipe.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and lay pipe ductile Iron in trenches/floor, Spigot/socket ends Class “K-7” ,150 mm (6”) dia.
Supply and lay pipe ductile Iron in trenches/floor, Spigot/socket ends,Class “K-7” ,100 mm (4”) dia.
M & L for DI fittings such as bends(any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, Collars, caps and plugs suitable for S/S or flanged DI pipes of any dia dia as required at the time of execution complete all as specified and directed.
M & L for Rubber gasket suitable for S/S DI pipe 150 mm
M & L for Rubber gasket suitable for S/S DI pipe 100 mm
Taking out old unserviceable CI sluice valve and S & F new cast iron sluice valve 80mm dia with s/s spindle complete assembly, class PN 1.0, ISI marked including providing rubber joints suitable for flanged pipes complete all as specified and directed .
All as per item No 9 above but 100 mm dia size.
All as per item No 9 above but 150 mm dia size.
M & L for repairs to sluice valves in position installed at various locations, taking out upper portion of valve, replacement of U/S Stainless steel spindle with check nut, cleaning and grinding the valve gate and assembling the valves including replacing the worn out nuts & bolts, rubber gasket, gland packing and servicing complete for 150mm bore size.
All as per item No 12 above but for 100mm bore .
Supply and lay in trenches/floors/walls of GI tubing medium grade with all fittings such as elbow, tee, union, short pieces etc of size 80mm dia bore complete all as specified and directed by engineer in charge.
All as per item ser No 14 here in before but of size 50mm dia.
All as per item ser No 14 here in before but of size 40mm dia.
All as per item ser No 14 here in before but of size 20mm dia.
All as per item ser No 14 here in before but of size 25mm dia.
Taking down steel tubing 20 mm dia and connections all as directed by engineer in charge.
Taking down steel tubing 25 mm dia and connections all as directed by engineer in charge.
Taking down steel tubing 40/50 mm dia and connections all as directed by engineer in charge.
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) of size 40/50 mm dia GI Pipes all as per directed by Engineer in charge .
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) of size 25 mm dia GI Pipes all as per directed by Engineer in charge .
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) of size 20 mm dia GI Pipes all as per directed by Engineer in charge .
Cutting existing steel tubing for alterations or additions (Each cut measured) of size 40/50 mm dia GI Pipes all as per directed by Engineer in charge .
Cutting existing steel tubing for alterations or additions (Each cut measured) of size 25 mm dia GI Pipes all as per directed by Engineer in charge .
Cutting existing steel tubing for alterations or additions (Each cut measured) of size 20 mm dia GI Pipes all as per directed by Engineer in charge .
Refixing old steel tubing 20 MM dia and connections in new or old position all as specified and directed by engineer in charge.
Refixing old steel tubing 25 dia and connections in new or old position all as specified and directed by engineer in charge.
Refixing old steel tubing 40/50 MM dia and connections in new or old position all as specified and directed by engineer in charge.
Supply and fix Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of size 80 mm dia complete all as specified and directed
All as per item No 32 above but for 50mm dia
All as per item No 32 above but for 40mm dia
All as per item No 32 above but for 25mm dia
All as per item No 32 above but for 20mm dia
M & L for dewatering from semi under ground sump 240000 Ltr capacity, cleaning internal walls, bottom surface of sump by removing scales and other foreign materials, scrubbing with water using coir jute brushes, washing the surfaces with mixture of bleaching powder and water. Finally washing with fresh water on walls, bottom surface etc applying two coats of white wash inside and outside as existing colour wash and writing letters( font Size 6 CM,Stencil type) on the wall i.e. capacity of tank, Date of cleaning, Due date for next cleaning, etc with synthetic enamel paint complete as specified and directed.
All as per item No 37 above but 112000 Ltr capacity
All as per item No 37 above but 45000 Ltr capacity
M & L for dewatering from RCC Over head reservoir of 112000 ltrs capacity (5 mtr staging), cleaning internal walls, bottom of sump by removing scales and other foreign materials, scrubbing with coir/ jute brushes using water, washing the surfaces with mixture of bleaching powder and water, finally washing with fresh water on walls, bottom surface etc, applying two coats of white wash inside and writing letters(font Size 6 CM,Stencil type) on the wall i.e. capacity of tank, Date of cleaning, Due date for next cleaning, etc with synthetic enamel paint complete as specified and directed
M & L for dewatering from Under ground Static water tank of 50000 Ltr capacity, cleaning internal walls, bottom of sump by removing scales and other foreign materials, scrubbing with coir/ jute brushes using water, washing the surfaces with mixture of bleaching powder and water, finally washing with fresh water on walls, bottom surface etc, applying two coats of white wash inside and outside as existing colour wash and writing letters( font Size 6 CM,Stencil type)on the wall i.e. capacity of tank, Date of cleaning, Due date for next cleaning, etc with synthetic enamel paint complete as specified and directed
M & L for repairs to Centrifugal pumpset of capacity 25 HP including replacing the worn out nuts, bolts, rubber gasket, gland packing with cup, ball bearing-02 Nos., gun metal shaft key, hard rubber coupling bush, etc and making serviceable condition complete servicing all as specified and directed
All as per item No 41 above but horizontal type of capacity 20 HP
All as per item No 41 above but vertical type of capacity 20 HP
All as per item No 41 above but of capacity 5 HP
S & F in replacement of Star-delta starter suitable to 25/20 HP pump set incl suitable relays, connection with existing pump set and testing to the satisfaction of Engr-in-Charge .
M&L in replacement of contactor 3 pole, 415 Volts suitable for 25/20 HP Auto Star Delta Starter.
M&L in replacement of Overload Relay of range 20 to 32 amps suitable for 3 Phase 20/25 HP Auto Star Delta Starter.
M&L for Spray painting to motor and pump set of 20/25 HP capacity incl foundation frame with one coat of synthetic enamelled paint etc all as specified and directed by engineer in charge.
M&L for Spray painting to motor and pump set of 5 HP capacity incl foundation frame with one coat of synthetic enamelled paint etc all as specified and directed by engineer in charge.
M&L Rewinding of motor of centrifugal pump set of 25 HP capacity by using super enamelled copper wire of suitable gauge to match with the existing including varnishing, drying,and replacement of UNSV parts of existing size/approved make such as bearing of appropriate size, nuts, bolts and washers, packing , etc complete all as directed.
M&L Rewinding of motor of centrifugal pump set of 20 HP capacity by using super enamelled copper wire of suitable gauge to match with the existing including varnishing, drying,and replacement of UNSV parts of existing size/approved make such as bearing of appropriate size, nuts, bolts and washers, packing , etc complete all as directed.
M&L Rewinding of motor of centrifugal pump set of 5 HP capacity by using super enamelled copper wire of suitable gauge to match with the existing including varnishing, drying,and replacement of UNSV parts of existing size/approved make such as bearing of appropriate size, nuts, bolts and washers, packing , etc complete all as directed.
M & L for taking down/removing u/s foot valve, supply and fix foot valve heavy duty 50 mm size of Brass body with screwed/flanged ends as required at site
All as per item No 53 above but for 65/80 mm dia
Supply only chlorine test kit with coloured Sample complete with all testing filament and Two Reagent Namely Sodium chloride(100 ML) and sulphuric acid (75 ML) solution in rexine finish box all as specified and directed.
Supply and fix Chloring dozing pump tube all as specified and directed ,Cat part No MCCP207-B of Declibec or Equivalent
Supply and Chlorine dozing duckbill only all as specified and directed .Cat part No MCCVDBO of Declibec or Equivalent
Supply and fix NRV 50 mm dia,Class PN1.6,Cast iron body, flanged both ends for iron pipe of size 50 mm dia complete all as specified and directed
Repairing of valve chamber including rusted MS cover complete without disturbing pipe line and Valve including necessary earth work including necessary earth work excavation, PCC 1:4:8 type D2 for foundation, brick work in cement mortar 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 3mm thick on 40x40x6 mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete of the Internal size 1800 mm x 1200 mm all as specified and directed by Engr in charge .
All as item No 59 But of internal size 900 mm x 900 mm.
S&F in replacement of Underground Sump tank cover /lid with locking arrangemernt made out of MS Sheet of size 5 mm thick and frame of MS flat iron including welding,preparing surface with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete of the size not more than 800 mm x 800 mm including embedding botton portion of in PCC Bed 1:2:4 type B1 complete all as specified and directed by engr in charge .Note : Taking down old tank cover and making good of the affected area shall be included above quoted rate .
M&L for arresting of water leakage from existing pipe line in position from GI pipe of 40/50/80 mm dia sizes ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI ( Bend,socket,reducer,tee,furrel, union ,solution,thred etc) and refilling etc complete.All as specifide and directed by Engineer- In- Charge. Note:- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.
Same as per item 62 but for size 15 to 25 mm Bore.
Taking down defective Non clog submersible pumpset 1 hp,8.5 M3/Hr capacity,Head 12mWC, 3 phase, 440 volts from the Equalization tank and lowering the same after repair/ replacement of defective spare parts i.e. staging bushes, shaft stainless steel, thrust bearing, water seal, stainer, etc complete all as specified and directed.
Taking down defective Recirculation Monobloc pumpset, 0.37 KW,5 M3/Hr capacity,Head 8 Meter , 3 phase, 440 volt and lowering the same after repair/ replacement of defective spare parts i.e. staging bushes, shaft stainless steel, thrust bearing, water seal, stainer, etc complete all as specified and directed.
Taking down defective Filter feed Monobloc pumpset, 1.5 KW, 9 M3/Hr capacity,Head 26 Meter , 3 phase, 440 volt and lowering the same after repair/ replacement of defective spare parts i.e. staging bushes, shaft stainless steel, thrust bearing, water seal, stainer, etc complete all as specified and directed.
Taking down defective Air blower , Twin lobe,Roots Type, 7.5 KW,240 M3/Hr capacity , 3 phase, 440 volt and lowering the same after repair/ replacement of defective spare parts complete all as specified and directed.
SRI AYYAPPA ENTERPRISES
ANAND REFRIGERATION
SAPTHAGIRI CONSTRUCTIONS
s v m construction building & engineers
M/S AMRITHESH ENTERPRISES
Aditya Associates
LAKSHMI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .