Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC GROUND FLOOR SARAJU VILLA 5A KHALISA KOTA PALLY KOLKATA BIRATI NORTH 24 PARGANAS WEST BENGAL 700051 | 24 PARAGANAS NORTH | WEST BENGAL | 700051 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹5.5 L+₹8,701.33 (1.62%)Rejected-Finance 7G CORNFIELD ROAD KOLKATA 700019 | KOLKATA | KOLKATA | WEST BENGAL | 700019 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹5.6 L+₹18,354.91 (3.42%)Rejected-Finance MAITANA BATTALA PURBA MEDINIPUR | MEDINIPUR EAST | WEST BENGAL | 721130 | L3 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
2 Aug 2024, 2:39 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, BMD, PHE, Dte
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Design development and installation of Remote monitoring system at four(4) point of CWR Inlet and outlet of Intake Kukrakuri of Chhatna Saltora water supply scheme under Bankura Mechanical Division,PHE Dte.
2024_PHED_706218_9
WBPHED/EE/BMD/NIeT- 6 OF 2024-2025
Open Tender
MECHANICAL
Item Rate
60 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹20,000
Yes
30 Aug 2024
12 Jul 2024
5 Aug 2024
12 Jul 2024
2 Aug 2024
12 Jul 2024
Amount
Supply & delivery of Battery Powered MQTT enable RTU for Intake Pump House SCADA The GPRS RTU Consist of inbuilt DI-8, DO=2, AI=4, AO=2, Real Time Clock & Calender Inbuilt, with additional feature for Supply Voltage Condition monitoring, RTU Health Monitoring, Lat /Long Geo Data and BAD Network montoring at remote Server. The DATA Transmission Protocols are Modbus DNP3, JSON, FTP and MQTT. The RTU has inbuilt 4G Modem Gateway with Firewall Router used to communicate with Central Server for DATA Exchange. The RTU is Powered from Solar, Battery and Grid Auto transfer Power Supply. Processor Dual ARM® Cortex® A7, plus ARM Cortex M3; 500 Mhz Memory • SRAM – 4 MB, battery backed static RAM • DDR3 RAM – 256 MB, dynamic RAM • NAND Flash – 256 MB, flash memory Events and datalogging • DNP3 and IEC 60870-5-104 events: 100,0005, store up to 1,000,000 events using internal file system • Store up to 100,000,000 events using USB drive or MicroSD card File system storage Approximately: 70 MB • USB host storage • Single-partition plug-in USB mass storage devices up to 32 GB, File format: FAT32
• MicroSD card Up to 32 GB formatted with the FAT32 file system. MicroSD cards larger than 32 GB can be used by preparing a 32 GB volume on the card. • Serial Ports: 1, 2 RS-485: 2-wire half-duplex operation. Maximum baud rate 115,200 bps. • IP Protocols: • Modbus/TCP Server, Modbus/TCP Client • Telnet Server, FTP Server, MQTT • Inndustrial Roter Equipped with Dual-SIM, 1 x LAN , 1 X WAN interface and Wi-Fi. 3 Level SIM-1, SIM-2 & WAN provdies alternative Internet sources with switching capability. • Environment: • -40…70 °C (-40…158 °F) operating temperature when the unit is mounted horizontally on a vertical surface • Input voltage: • Rated Voltage 12…30 Vdc, 3W
• Input Sensor: Flowmeter / Level Sensor/ Pump Motor Status/ Chlorine Dosing Pump Status/ Electrical Supply Parameter/RTU Battery Condition • Output: MODBUS DNP3 RTU/MQTT/JSON / FTP (.csv) Server • PANEL Enclosure, MOC: SS, size:450(H)X550(W)X2580(D)mm, Make: RTU Module: Schneider_Electric India Pvt. Ltd. Integraton By: System Advance Technologies PVt. Ltd. SI of SE Supply, delivery, configuration of 4th GEN WEB Based PWS SCADA for Bankura District, consist of the following design, development work for under mentioned module: i) SCADA DATA Server Back End Programming, ii) Basic WEB Page Design and Modification, iii) Alarm Page on Geo Location iv) GEO Location page design and Setup modification, v) Historical Data Display design, vi) Report Printing, vii) Histogram, Pie, Line Chart design, viii) Sufficient Data Storage. ix) HTTPS:\\...API WEB Service design and development in existing DATA Exchange with PHED HQ Servers. Make: SI of Schneider Electric
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work i) 20 mm dia for signal Cable laying
Installation, Commissioning, Calibartion, of RTU Panel, flowmeter ,Level Sensor, Connectivity with Server & VPN Network as per instruction of EIC. Execution By: OEM Authorised Vendor.
Add: 18% GST
Add: 1% Cess
CONCORD ENGINEERING
MENAKA ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .