Loading…
Loading…
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
5 Jun 2026, 3:30 pmClosed
Provision of CCTV Cameras at RPF Post/Outpost having coverage over space provided for keeping accused and interrogation purpose over Lucknow Division, Northern Railway.
106-Tele_Tender_04_26-27
106-Tele_Tender_04_26-27
Open
270 Days
Lucknow, Uttar Pradesh
₹0
₹5.0 L
15 May 2026
15 May 2026
22 May 2026
"Supply of 2MP BULLET CAMERA with night vision with IR range 50 mtr.Specification : 2MP Full HD IR Network realtime high resolution Outdoor BulletCamera with range 50 Mtr, 1/2.8"""" 2MP Progressive scan CMOS, Frame Rate - 25-30 fps,Minimum Illumination - 0.03 [email protected] (color1/30s,30 IRE) 0.009 [email protected](color1/3s,30 IRE) 0 [email protected] (IR on), EffectivePixels - 1920(H) x 1080(V), 2Megapixels,Shutter Speed - Auto/Manual, 1/31/100000s, Lens Type - Fixed, FocalLength-6 mm, Iris Control - Yes, AGC - Yes, AWB -Yes, Video Streaming - Dualcompressedstream, Video Compression - H.265+ H.265/ H.264+ / H.264H /MJPEG , S/N Ratio -More than 50dB, Resolution - 01 1080P ( 1920 x1080 ),Full HD(1920 x 1080 Pixel), Protocol- HTTP, TCP, ARP, RSTP, RTP, UDP, DHCP,DNS, IPV4,NTP, Multicast, ONVIF, CGI,Power Source- DC12V, PoE (802.3af), IR Range- 50Mtr. ;, Intelligent analysis built in AI Humanoid detection algorithm (AI Humanoid detection) Make :- Honeywell / HIKVISION / CP-PLUS/ SONY/SAMSUNG or better. This includes the installation, testing and commissioning of the system along with necessory accessories for the installation and required at site. This also includes the Cage for the protection of the camera from outside hazards and memory card upto 128GB storage capacity of standard Make such as CP Plus, Hikvision, Dahua or betters .This includes installation of the camera and associated items required for the installation INSPECTION: RITES"
"Supply of 2MP DOME CAMERA with night vision. Specification : 2MP Full HD IRNetwork real time high resolution Dome Camera with range 30 Mtr, 1/2.8"" 2MPProgressive scan CMOS, Effective Pixels - 1920(H) x 1080(V), MinimumIllumination - 0.01 [email protected](Color,30 IRE) 0.001 [email protected] (B/W,30 IRE)0 Lux(IR on), S/N Ratio 40-50 dB , Frame Rate (fps) - 20 fps, Shutter Speed -Auto/Manual, 1/3 1/100000s, AGC - Yes, AWB - Yes, Lens - 3.6mm, Lens Type -Fixed-focal, Iris Control - Fixed iris, Video Streaming - Dual compressed stream,Video Compression - Instastream/H.265/SmartH.264+/H.264/ H.264B/ MJPEG(only supported by the sub stream), Resolution -1080P (1920 x 1080); 1.3MP(1280 x 960);720P (1280 x 720); D1 (704 x 576/704x 480); VGA (640 x 480);CIF (352 x288/352 x 240), Protocol - IPv4; IPv6; HTTP; TCP; UDP; ARP; RTP;RSTP; SMTP;FTP; DHCP; DNS; DDNS; NTP; Multicast; ICMP; IGMP; ONVIF (ProfileS); CGI; Power Source - DC 12V,PoE (802.3af);Make :- Honeywell / HIKVISION /CP-PLUS / SONY / SAMSUNG or better. This also includes the Cage for the protection of the camera from outside hazards. This includes installation of the camera and associated items required for the installation INSPECTION:RITES"
"Supply, configuration and installation of 8 input and 8 output channel NVR capacity NVR with ethernet, HDMI and VGA output at upto 4K (3840 x 2160) resolution. with HDD SATA Port. .8 Channels or better NVR with supports up to 2 SATA hard drives each support up to 8TB, Should be loaded with 8 TB Capacity of HDDs. .Support 4K streaming, Support 8 Channel up to (3840*2160) Resolution Support 100 Mbps of incoming Bandwidth, support e-sata and USB .Support H.264, H.265 03 .Support ONVIF 2.0 and above cameras, .Should support Remote live view and remote playback, .Interface: 2 USB, 2 HDMI, 1 VGA, 2 SATA, 1 CH Audio In, 1 CH Audio out, Should support Network storage and backup, Rack mountable. .Should support 8 Channels streaming in Single screen, 8 Channels synchronous .Playback .Certification- Certification: CE/ equivalent Indian standard, FCC/equivalent Indian standard, UL/equivalent Indian standard and BIS certified at the time of bidding NVR and IP CCTV camera should be same make. Make: Hikvision/ Panasonic/Sony/ Dahua or similar INSPECTION: CONSIGNEE FOR SUPPLY INSPECTION"
"Supply and installation of 8TB Hard Disk Drive Internal for CCTV for NVR (Surveillance) with 3 year Waranty Make:- WD/Seagate/Toshiba or similar INSPECTION: RITES FOR SUPPLY PORTION"""
"Supply & Installtion of 55"" LED UHD smart TV of reputed make like LG model 55 UP 7740 PTZ/Samsung/Sony or any other reputed make with similar or better specs. INSPECTION: RITES FOR SUPPLY PORTION"
"Supply of layer-2 switch ( minimum 8 +2 manageable ) with 08 Nos. 10/100/1000 06 Mbps ethernet port POE and 02 nos.1000 baseX SM SFP port with optical modules complete with all accessories etc. as per RDSO specification no. RDSO/SPN/TC/65/2021 version-6 or latest INSPECTION: RITES"
Installation, Testing & Commissioning of Layer-2 PoE Switch (minimum 8+2 port 07 manageable) with 8 nos. 10/100 /1000 Mbps Ethernet port and 2 nos. 1000 Base X SM SFP port with optical modules complete. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost.
"Supply of 12 Fiber Armored Single mode Optical Fiber ITU - G 652 D. All Dielectric Self Supporting Optical Fiber Cable as per GEM Specification Enclosed. Make: FINOLEX, KEC or Better INSPECTION: CONSIGNEE"
"Supply of STP CAT-6 Cable (Shielded Twisted Pair) STP compliant with latestEIA/TIA- 568-B2-1. INSPECTION: RITES"
"Supply of armoured power cable 3 core, 2.5 sq mm, multi strand (36/0.3 mm dia) cable as per IS 694:1990 reaffirmed 1995 or latest suitable for Railway electrification area, shall be of reputed make like Havells, Delton, LAPP, Finolex, or superior. INSPECTION: RITES"
"Supply of PVC conduit pipe (minimum 25 mm dia./1.55 mm thick, 3 metre long and ISI brand) with flexible pipes fixing /laying materials and all other accessories as per requirement. INSPECTION: CONSIGNEE"
Fixing & laying of PVC Conduit Pipe /PVC Capping-n- casing (channel). As perinstructions by Consignee
Laying of CAT-6/Power cable/OFC in PVC Conduit pipe of 25 mm Dia ISI mark .
"Supply of 2 KVA ONLINE UPS WITH TWO HOUR BACKUP ,HAVING SMF BATTERY 4680 14 TO BE OPERATED IN INPUT VOLTAGE OF 160- 260V 50 Hz AC,INPUT OVER VOLTAGE PROTECTION 280 VAC,INPUT UNDER VOLTAGE PROTECTION 155 V AC,WITH MANUAL BY PASS PROVISION,OVER LOAD CAPACITY OF 125 % OF RATED LOAD UNDER TEST FOR 60 SEC. WARRANY OF 2 YEARS FOR UPS INSPECTION: RITES"
"Supply and installation of 9U, 19 inch rack for pole mount/ wall mount with Fan 230VAC 90CFM-02 Nos., AC distribution box (5 socket of 5A, Power On LED indicator, MCB)- 01 No., Shelf Cantilever 1U: 01 No. Cable Manager 1U:01 No. INSPECTION: RITES FOR SUPPLY PORTION"
"Supply of STP/UTP RJ 45 Connectors Make D-Link, AMP, DAX, Legrand, Molex or Digilink. INSPECTION: CONSIGNEE"
"Supply of 12 port loaded LIU rack mountable, LIU shouldbe provided for terminating the optical fiber cables. It shall provide minimum bending radius and splice trays shall function as a 17 splice cover for Pigtail Splicing. Cable glands shall be provided for secure anchoring of incoming cables. Rubber grommets shall be provided at the cable entry point for tight sealing. The splice tray should be made of ABS materials. LIU should be of reputed make. Make: D-Link/3M/ Digilink/Molex/ DAX or similar. INSPECTION: CONSIGNEE"
Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost.
"Supply of HDMI Cable should beHigh Speed support Data Transfer rate of upto 19 minimum 10 GBPS or higher.Connectors must have a minimal lockingcapability to prevent ousting of cablesfrom ports. Should have an overallshield against EMI/RF interference,Length 10 Mtr. Make: Kramer/Aten/Extron or Reputed Technically Equivalent/better make. INSPECTION: RITES"
Blowing/drawing of OFC cables inthe HDPE duct along with all theprotective work as per instructionsof engineer incharge at site.Inspection: Consignee
"Supply of 40 mm outer dia. PLB HDPE duct as per RDSO Spec. No. RDSO/SPN/TC/45/2013, Rev 2.0 or latest with all accessories (like couplers, bends etc) INSPECTION: CONSIGNEE"
Laying of PLB HDPE pipe in trench/open space, fixing and clamping of HDPE pipe on 22 wall or structure and sealing of the duct after laying with proper fixing material. All the accessories like couplers, end caps/plugs to be provided by the contractor within the same cost and its protective work as per direction of site engineer.
"Supply of workstation suitable for fault analysis or other application. Note:- Workstation configuration are as follows: Intel Core i5 10500 or higher, 16 GB RAM, HDD 1000 GB, 23 SSD 512 GB Windows 10/11, 2K display 21.5 Inch or better with dedicated 4GB or higher graphic card. It also includes supply of Laser Printer (Make HP/Brother or better) and supply of 600VA Ofline UPS with minimum backup of 15-20 Mins (make: Microtek/Luminous/APC/Uniline or similar). INSPECTION: RITES FOR SUPPLY PORTION"
"Supply, Installation & commissioning of Maintenance free earth using basic earthing kit as per RDSO specification RDSO/SPN/197/2008 or latest and Drg No. SDO/RDSO/E&B /001 & 002 dated 19.9.2008 or latest. Earthing kit consist of 1. Earthing electrode of 17mm dia and 3 meter long-01 no. 2. MEEB (300mm X 25mm X 6MM) -01 no. 3. SEEB (150mm X 25mm X 6 mm) - 01 no. 4. Earth enhancing compound - 30 Kg (minimum). This include provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, IPS, data logger, signal etc. with PVC earth wire of size 16/25 Sq.mm through copper lugs of suitable size. PVC wire shall be supplied by Railways. 24 Note: At certain locations it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/pit due to soil resistivity. In such case provision of loop earth consisting of more than one earth pit shall be done. For interconnection of two earth pits copper tape of size 25X2 sq. mm shall be provided by contractor. The number of pits required shall be decided based upon the resistance achieved for the earth pit already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Material to be procured through RDSO approved firm. Contractor have to submit check list duly signed by OEM after installation. INSPECTION: RDSO FOR SUPPLY PORTION"
Chase cutting in floor/wall and restoring of floor/wall with plaster for concealing of 50 mm/25 mm conduit pipe in floor/wall
Splicing/Dropping /Termination of each fibre/pigtail in the LIU/I0 Box/Terminal Joints 26 through fusion splicing of termination of OFC cables. The fibres terminated shall be tested and the test report (Hard copy and soft copy) shall be submitted to the site Engineer for records . Each fibre shall be properly marked with necessary ferrules/tags.( Inspection by Railway Site Engineer
Excavating and refilling of trench in Normal Soil to the level of ground with rammed 27 earth as per drg. No. NR/S&T/Con./1.1/97A or latest so as not to form a drain 0.3 mtrs. Wide & 1 mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan in all type of soil. It also includes clearance of roots of trees & bushes. (15cm wide 30cm depth)
Horizontal direction drilling(HDD)/Trenchlessdigging/machine drilling withoutdamage to surface road /trackfor laying/insertion ofHDPE/GI/DWC pipe. The boreshall be done at the depth ofminimum 1400 mm from theground level. The ground levelshall be considered ignoring thebank 28 height of the bank of the road. Note:- DWC/HDPE/GI PipeSupply is not covered under thisitem. Contactor shall provide allmaterial required for work andadequate nos. of labours forproper laying of cables into thebore. Cable shall be laidcautiously so that it should notget damage due to roughhandling & pressure on cable.Payment of boring shall bemade only aft er DWC/HDPE/GIpipe is laid in the bore."
"Supply of OFC patch cord cable (10m long with APC/FC/LC-LC/FC/APC connector Patchcord). INSPECTION: CONSIGNEE"
"Supply of Single Mode Patch Cord length 3 meters (LC-SC/SC-SC/LC-LC/FC-LC) as per site requirement. INSPECTION: CONSIGNEE"
"Supply of LC/SC-LC/SC patch cord (5 meter) (3M, TE connectivity, R&M make or superior) INSPECTION: CONSIGNEE"
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS11.pdf
ATTACHMENT
Tender Document
ATTACHMENT
ACSGCC22-231to6.pdf
ATTACHMENT
GCC Correction slip 7 to 10
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipno7-10.pdf
ATTACHMENT
TenderDocument0426-27-PUB.pdf
ATTACHMENT
Download all tender documents and submit your bid