Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹45.3 L Quoted ₹46.0 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹47.7 L+₹1.7 L (3.77%)Rejected-Finance NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹47.7 L+₹1.7 L (3.77%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹50.0 L+₹4.0 L (8.69%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹50.0 L+₹4.0 L (8.69%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
18 Dec 2023, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
COMPREHENSIVE MAINT OF FIRE FIGHTING SYSTEM FIRE ALARM SYSTEM LIFT SERVO VOLTAGE STABILIZERS FOR BALANCED UNBALANCED LOADS APFC PANEL AREA LIGHTNING INFRASTRUCTURE EXTRL ELECTRICAL DISTRIBUTION NETWORK LT FEEDER PILLAR BOX PANEL AT AFS JALAHALLI
2023_MES_628503_1
8849/E8
Open Tender
Electrical and Maintenance Works
Item Rate
271 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹98,000
29 Dec 2023
20 Nov 2023
20 Dec 2023
20 Nov 2023
18 Dec 2023
4 Dec 2023
21 Nov 2023 - 27 Nov 2023
Amount
Comprehensive maintenance of goods lift to carry goods of 500 kg capacity with a speed of 0.5 metre/sec, of Make : Johnson to serve ground floor and two upper floors with AC variable voltage & variable frequency drive(VVVF DRIVE) system, microprocessor based control system all as per IS 14665 hall position indicators on all floors, car position indicators in cabin, battery operated alarm bell and emergency lights including cabin light & fan over load switch, auto revelling, intercom facility with centre opening, stainless steel power operated sliding doors, including Examining the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell , etc. complete all as specified and directed. Location : Gurukul, D Block - 01 No Note: (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only. (b) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Comprehensive maintenance passengers lift to carry 13 passengers (884 Kg) capacity of Make: Schindler to serve ground floor plus two floors, including Examining the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell, etc complete all as specified and directed. Location : SMC - 02 No Note: (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only. (b) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Comprehensive maintenance passengers lift to carry 08 passengers (554 Kg) capacity of Make: Schindler to serve ground floor plus two floors, including Examining the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell, etc complete all as specified and directed. Location : SMC - 01 No Note: (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only. (b) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Comprehensive maintenance passengers lift to carry 08 passengers (500 Kg) capacity of Make: Johnson to serve ground floor plus two floors, including Examining the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell, etc complete all as specified and directed. Location : Gurukul, A Block - 01 No Note: (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to lift noticed during the period by providing materials and labour.
Supply only Relays as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply only Relays as per existing model suitable to 08 passenger Lift Makes Schindler India Pvt Ltd/ Johnson all as per specified and directed
Supply only Rectifiers as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply Rectifiers as per existing model suitable to 08 passenger Lift Makes Schindler India Pvt Ltd / Johnson all as per specified and directed
Supply main contactors as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed.
Supply only for main contactors as per existing model suitable to 08 passenger Lift Makes Schindler India Pvt Ltd/ Johnson all as per specified and directed.
Supply only transformer as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply only transformer as per existing model suitable to 08 passenger Lift Makes Schindler India Pvt Ltd / Johnson all as per specified and directed
Supply only Gate lock switches as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply only Gate lock switches as per existing model suitable to 08 passenger Lift Makes Schindler India Pvt Ltd / Johnson all as per specified and directed
Supply only Gate lever as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply only Gate lever as per existing model suitable to 08 passenger Lift Makes Schindler India Pvt Ltd / Johnson all as per specified and directed
Supply only Landing Floor indicators as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply only Landing Floor indicators as per existing model suitable to 08 passenger Lift Makes Schindler India Pvt Ltd / Johnson all as per specified and directed
Supply only Limit switch as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply only Limit switch as per existing model suitable to 08 passenger Lift MakesSchindler India Pvt Ltd / Johnson all as per specified and directed
Supply only floor level switch as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply only floor level switch as per existing model suitable to 08 passenger Lift Makes Schindler India Pvt Ltd / Johnson all as per specified and directed
Supply only OSG pulley top bottom complete as per existing model suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply only OSG pulley top bottom complete as per existing model suitable to 08 passenger Lift Makes Schindler India Pvt Ltd / Johnson all as per specified and directed
Supply only travelling cable as per existing model and size suitable to 13 passenger Lift Makes Schindler India Pvt Ltd all as per specified and directed
Supply only travelling cable as per existing model and size suitable to 08 passenger Lift makes Schindler India Pvt Ltd / Johnson all as per specified and directed
Dismantling the existing unserviceable hoisting motor of 10 HP capacity 3 phase, 440 volts from site and carrying out rewinding, changing bearing and all connected parts etc. including transporting the motor to the workshop and back and fixing to its original position all as specified and directed
Supply and fixing ARD system in case of mains power failure and Lift control system failure, the Lift’s own rechargeable and maintenance free battery power shall move the car to the nearest floor and the door shall open automatically for automatic rescue of passengers. A battery run-down indicator shall be provided complete with Battery 12volts and battery charger and make the system functional all as specified and directed.
Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, 7.5AH, suitable for passenger/ goods lift as required at locationSMC/ Gurukul bldg. including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide / Amar raja / Amaron Note :- (i) The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract.
Servicing/ comprehensive maintenance of fire alarm system comprising of Smoke detection control panel (to accommodate and sensing signals from wireless smoke detectors), Smoke detector (Photoelectric detection Technology), External wireless siren strobe, wireless repeater to extend the communication range of detectors, Conventional Fire Alarm control panel, flame detector, conventional manual call point with EN 54-11 : 2001 and LPCB, conventional sounder etc by attending fault testing of system, quarterly checking of system including preventive maintenance by replacing small spare parts complete all as specified and directed. Location : Gurukul, AFTC Officer Mess, ETI, CTI AFNET, Bldg No. P-389 (Ground floor), P-389 (1st Floor), Bldg No. P-506 Lab, Immols Room 1 & 2 - 09 Nos
Note for item No 30 :- (a) The repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The rate quoted shall be deemed to include for carried out all repairs noticed during the period. (c) The authorised service agency must be attended as and when called for urgent nature of repair of the fire fighting equipment's. (d) Checking of Alarm signal should not lost when primary power failure untill the alarm signal processed. (e) Checking of audio amplifiers and tone generating equipment. (f) Checking of smoke detector sensibility (g) Checking of all speaker circuit and loops. (h) Periodically shall be overall 3 months or as per manufacturers recommendation.
Supply & install in replacement smoke and heat detectors, photoelectric / optical type certified to EN 54 addressable with self built intelligent with connected accessories complying with optical chamber, cover, case molding, photodiode (transducer), infrared LED all as specified and directed. NOTE:- i). Metal junction box of suitable size for detector made of 16 SWG sheet steel is to be provided for mounting of detectors in the concrete mother ceiling / surface along with necessary gland and boxes duly painted with two coats of super enamelled paint over a coat of red oxide primer. ii) Rate of metal boxes shall be including in quoted rate of items. Make :- Ceasefire/ Visionic/ Universal (Rqvel)/ Honeywell or equivalent as per site requirement.
Supply & install in replacement Fire Alarm Sounders / Sirens Electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtrs range. Make :- Ceasefire/ Visionic/ Universal (Rqvel)/ Honeywell or equivalent as per site requirement.
Supply & install in replacement Addressable electronic sounder cum strobe. Make :- Ceasefire/ Visionic/ Universal (Rqvel)/ Honeywell or equivalent as per site requirement.
Supply & install in replacement Addressable manual call point resettable type. Make :- Ceasefire/ Visionic/ Universal (Rqvel)/ Honeywell or equivalent as per site requirement.
Supply & install in replacement Addressable control module. Make :- Ceasefire/ Visionic/ Universal (Rqvel)/ Honeywell or equivalent as per site requirement.
Supply & install in replacement Addressable monitor module. Make :- Ceasefire/ Visionic/ Universal (Rqvel)/ Honeywell or equivalent as per site requirement.
Supply & install 2 core solid conductor of size 1.5 sqmm, as per IS-1554 PVC insulated & PVC sheathed, armoured cable FRLS down through non metallic PVC conduit of suitable size shall be properly clamped to the ceiling / surfaces including taking down of unserviceable cable and 'S' loop shall also be left where cables connect to sounders, panels and all the cables and wires shall be tagged for proper identification complete all as specified and directed.
Attending unserviceable/ non functional street light complaints (for street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillers etc) by deploying technically qualified and experienced technicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for domestic area of OMQ, 6th Camp, 7th camp & ETI, E&ITI, 16 TETTRA school, Stn HQ east, ECHS technical area of including various connecting roads and other facilities such as shoping complex/ various institutes/ messes/ play ground, complete perimeter etc located in complete domestic area and technical area at AF Station Jalahalli
Note : The following items are deemed to be inclusive of quoted rate :-
(a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
(b) Contractor or his Authorised Representative has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very regular basis.
(c) A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User along with Contractor or his authorised Representative.
(d) Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account.
(e) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipment's to remove the breakdown. Fault will be intimated through Telephone/ SMS.
(j) Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department.
(k) Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department.
(l) Materials required for the repairing of the lights shall be measured and paid separately under respective item(s). But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to be included in the rate quoted.
(m) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
(n) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
(o) All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
(p) Attending and repairing complaint for one light of any type shall be measured and paid as one Job.
(p) Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
(i) Contractor has to ensure serviceability of all Street/ Security Lights in above mentioned DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.
(f) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(g) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Charge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(h) The decision of the Accepting Officer is this regards shall be final and binding.
Supply only porcelain lamp holders pin / screw type suitable for HPSV/MH type fitting 70/ 150/250 Watts.
Supply only capacitor suitable for HPSV/MH 70/150/250 Watts.
Supply only igniter suitable for 70 watts to 400 watts HPSV/MH lamp fittings, complete, all as specified and directed.
Supply and fixing the electronic controller with accessories (LED outdoor Driver) of 24V to 40V suitable upto 30 watt LED fittings complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply and fixing the electronic controller with accessories (LED outdoor Driver) of 40V to 75V suitable upto 45 watt LED fittings complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply and fixing the electronic controller with accessories (LED outdoor Driver) of 75V to 110V suitable up to 75 watt LED fittings complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply and fixing the electronic controller with accessories (LED outdoor Driver) of 75V to 145V suitable up to 100 watt LED fittings complete all as specified Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply and fixing the surge protection device 5KV voltage compatible with industrial and out door type LED fixtures up to rated power of 50W complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply and fixing the surge protection device 5KV voltage compatible with industrial and out door type LED fixtures rated power of above 50W & up to 100W complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Polycab
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25 - 50 sqmm 3.5 core size of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
Removing ,errecting steel swaged tubular pole 8.5/9 mtr long, bracket for fixing street light and refixing the same including necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) for foundation of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specified and directed by Engr-in-chrage.
Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole complete including taking down old or Old U/S bracket from the pole as directed.
Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, final taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with black up to 1.5 meter from top of PCC 1:2:4 with 20 mm aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm aggregate foundation and coping as per TD drawing including dismantling & removeing from the site damaged pole one complete all as specified and as directed.Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of block and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of alu paint over a coat of red oxide primer the rate for above items shall be deemed to be inclusive in the quoted rate.
Supply and fix LED flood light fitting 200 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 200 W.including taking down old fitting unserviceable. Make: Philips/ Bajaj/ CG
Supply and fix LED flood light fitting 70 W integral type light fixture, cast aluminium body, reflector, drivers, LEDs and accessories with system wattage 70 W.including taking down old fitting unserviceable. Make: Philips/ Bajaj/ CG
Supply and fix Contactor two pole 25-32 Amps suitable for street light timer switch including taking down the old fitting unserviceable. Make: Philips/ Bajaj/ CG
Supply and fix in replacement whether proof PVC junction box approved by CPRI street light control box made out of not less than 2mm thick of size 140mm x 140 mm x 5mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing and clamping complete and all as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete all as specified and directed by Engr-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-charge.
Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed by Engr-in-charge.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil obtained from excavation under item No 1 shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness will be considered for payment.
Material and labour for well burnt class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed by Engr-in-charge.
Supply and laying of GI pipe light grade for cable protection of size 40mm bore complete with fitting complete including taking down unserviceable one all as specified and directed by Engr-In-Charge.
Material and labour for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed by Engr- in -Charge . Make: Havells/ Polycab/RPG Asian
Material and labour for 3 ½ core 50 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed by Engr- in -Charge . Make: Havells/ Polycab/RPG Asian
Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate complete all as specified and directed.
Note for item No 85 :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Material and labour for 4 core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed . Make: Havells/ Polycab/RPG Asian
Material and labour for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed . Make: Havells/ Polycab/RPG Asian
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make :Vinitec with input variation between 300V to 480V with output stabilized at 415 Volts of capacity 200 KVA with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : AFS AFNET SECTION
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make :Vinitec with input variation between 300V to 480V with output stabilized at 415 Volts of capacity 300 KVA with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : AFTC Pump House
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make :Vinitec with input variation between 300V to 480V with output stabilized at 415 Volts of capacity 1000 KVA with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : Gurkkul
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make :Vinitec with input variation between 300V to 480V with output stabilized at 415 Volts of capacity 300 KVA with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : AFTC Power House
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make :Power One with input variation between 276V to 450V with output stabilized at 415 Volts of capacity 225 KVA with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : 16 Tettra School
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make :Vinitec with input variation between 300V to 480V with output stabilized at 415 Volts of capacity 100 KVA with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : Telephone Exchange
Note for Item No 95 to 100 :- (a) In above comprehensive maintenance shall be done through authorised person of OEM only. (b) The rate quoted shall be deemed to include for carried out all repairs to servo stabilizer noticed during the period 09 months. (c) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate. (d) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Supply only Microprocessor board of servo stablizer of capacity 100KVA to 300KVA all as specified and as directed.
Supply only Servo motor suitable for 100KVA to 300KVA all as specified and directed.
Supply only Buck Boost transformer of servo stablizer of capacity 100KVA to 300KVA all as specified and directed..
Supply only Bypass switch of servo stabilizer of capacity 100 KVA to 300KVA all as specified and directed.
Supply and fixing in replacement contactor MNX 25 Make - L&T /BCH/Schneider
Supply and fixing in replacement contactor MNX 70 Make - L&T /BCH/Schneider
Supply and fixing in replacement contactor MXA 1 Make - L&T /BCH/Schneider
Supply and fixing in replacement MCB SP 6A Make - Make - L&T/Havells/Indoasian
Supply and fixing in replacement MCB SP 16A Make - Make - L&T/Havells/Indoasian
Supply and fixing in replacement MCB SP 63A Make - Make - L&T/Havells/Indoasian
Supply and fixing in replacement MCB SP 32A Make - Make - L&T/Havells/Indoasian
Supply and fix LED flood light fitting 50 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 50 W.including taking down old fitting unserviceable. Make: Philips/ Bajaj/ CG
Supply and fix LED flood light fitting 30 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 30 W.including taking down old fitting unserviceable. Make: Philips/ Bajaj/ CG
Supply and fix in repair Time switches Digital 24 hour, 440 V three phase with contactor TP of rating 32 Amps and MCB TPN of rating 40A fitted in steel enclosure with necessary accessories to fixing RCC/steel tubular pole including bracket, nuts, bolts, washers etc. and making all necessary connections through connectors complete all as specified and as directed .Make : L&T/ Havells/ Indoasian
Supply and fixing LED flood light 100 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity. Make : Havells /Bajaj/Philips/CG
Supply and laying of GI pipe light grade for cable protection of size 80mm bore complete with fitting complete including taking down unserviceable one all as specified and directed by Engr-In-Charge.
Material and labour for Boring of holes under road, pavement hard standings by trenches technology using ultra sound technique and necessary machine including HDPE pipes of 30 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed by Engr-in-charge.
Material and labour for 3 ½ core 240 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed by Engr- in -Charge Make: Havells/ Polycab/RPG Asian
Material and labour for 3 ½ core 150 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed by Engr- in -Charge Make: Havells/ Polycab/RPG Asian
Material and labour for 3 ½ core 120 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed by Engr- in -Charge Make: Havells/ Polycab/RPG Asian
Supply and fixing in replacement MCCB 200A,3P,36KA Make - Make - L &T/Havells/Indoasian
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one all as directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate is deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( copper strip will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Comprehensive maintenance of Automatic Power Factor Correction Panels ( APFC ) at various sub stns of capacities 40 KVAr - 01 Nos and 35 KVAr - 02 Nos and comprising of following works :- (i) Repair / maintenance of Contactors, Relays and Capaciters , MCCBs & MCBs provided in the APFC Panel (ii) Monitoring and effective management of power factor correction near to unity as per the veriation of load in the corrrosponding transformer in terms of serviceability of MCCB/MCBs , Contactors , Capacitors and Relay and dispaly unit inculding the following Technical services:- The following daily Maintenace to be carried out : (a) Check seviciablity of APFC panels , MCCBs/MCBs, Contactors, Relays etc. (b) Maintain a register to note the values of power factor from all APFC Panels and VCBs panel at MRS and that should be submitted to concerned JE (E/M) or AGE(E/M) . (c) Check the connection and serviciablity of incoming cable from Main LT Panels to APFC Panels (d) Checking and tightening control wiring and rectifying the defects if any.
Note :(i) The Contractor will responsible for maintaining the power factor near to unity on induvidual APFC Panels and overhaul the value at main Receiving Stn . Contracor will responsible for, the penalty/ compensation charges which charged by BESCOM , due to Low Power factor and same amount should be paid by the contractor from his own account. The above quoted rate is inclusive of all regarding to maintain the APFC Panel power factor. (ii ) The Capacitors, Contactors, Relays replaced will be measured and Paid separetly. However, the labour element is included for replacement of wornout/ defective components.
Supply & Fix in replacement of three phase power capacitor duty contactors of following ratings including taking down old item all as directed :-
10 KVAR Make : L&T/ Siemens (Epcos)/ Schneider
5 KVAR Make : L&T/ Siemens (Epcos)/ Schneider
25 KVAR Make : L&T/ Siemens (Epcos)/ Schneider
20 KVAR Make : L&T/ Siemens (Epcos)/ Schneider
Material and labour for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 25x6 mm (up to 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, check nuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as specified and directed by Engr-in-charge.
Note for item No. 152:- (a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Material and labour for in repairs Galvanised Earth strip of size 25 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
ARUNOTHAYA TRADERS
devan enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .