Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.0 L+₹1.5 L (22.5%)Rejected-Finance | L2 | Rejected-Finance Quoted amount more than L1 | |
| 3 | L3₹8.5 L+₹2.0 L (30.3%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L3 | Rejected-Finance Quoted amount more than L1 | |
| 4 | L4₹8.8 L+₹2.3 L (35.3%)Rejected-Finance 119 LANE NO 4 DAYA NAND NAGAR LAWRENCE ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L4 | Rejected-Finance Quoted amount more than L1 | |
| 5 | L5₹9.2 L+₹2.7 L (41.1%)Rejected-Finance | L5 | Rejected-Finance Quoted amount more than L1 |
Tender Value
₹8.0 L
EMD Value
₹16,000
Closing Date
17 Oct 2020, 12:00 pmClosed
Lt Col Vipin V Kumar
Garrison Engineer Ranchi, 7th Club Road, PIN-834001
REPAIRS/REPLACEMENT OF STREET LIGHTS AND CONNECTED WORK AT ARMY CAMP JAMSHEDPUR UNDER GE RANCHI
2020_MES_383205_1
8400/1098/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class E cat b (ii)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹16,000
Yes
19 Dec 2020
3 Oct 2020
19 Oct 2020
4 Oct 2020
17 Oct 2020
8 Oct 2020
Amount
Taking down street light fluorescent tube/HPSV/HPMV/CFL/LED fitting from pole, walls and dismantling for checking of unserviceable tubes, chokes, starter, ignitor, capacitor, bulbs, bulb holder an re-fixing in existing position after repairs for proper functioning :- Note:- (i) Spares required for repair will be measured and paid for separately as supply & fix in replacement. (ii) Necessary T&P including ladder shall be arranged by the contractor for attending / repairing of street lights. (iii) The contractor, his authorized representative shall attend AGE E/M office daily 09.00 hrs/ office working hrs for collection of unserviceable street lights for the area concerned and render completion to this effect to the JE E/M incharge/ Engineer in charge. (iv) In case contractor or his authorised representative fail to attend / repair the street light with in the stipulated time / someday. He has to pay penealty of Rs 500/- per day and shall be recovered from overall quoted amount of contract aggrement.
Fixing only Ballast for HPSV fittings 250 Watt 230 V, A/C compact copper wound.(Item issued by the department under Sch 'B')
Fixing only Ballast for HPSV fittings 150 Watt 230 V, A/C compact copper wound.(Item issued by the department under Sch 'B)
Fixing only Ballast for HPSV fittings 70 Watt 230 V, A/C compact copper wound.(Item issued by the department under Sch 'B)
S&F Driver for LED Street light 45 Watt 230 V, A/C .Make :- Havells/Bajaj/ CG/ Philips /HPL.
S&F Driver for LED Street light 60 Watt 230 V, A/C .Make :- Havells/Bajaj/ CG/ Philips /HPL.
Fixing only lamp for HPSV fittings 70 Watt 230 V, A/C compact copper wound.(Item issued by the department under Sch 'B)
Fixing only Lamp for HPSV fittings 150 Watt 230 V, A/C compact copper wound.(Item issued by the department under Sch 'B)
Fixing only Lamp for HPSV fittings 250 Watt 230 V, A/C compact copper wound.(Item issued by the department under Sch 'B)
Porcelain lamp holders suitable for HPSV / CFL fitting
S&F Ignitor 230V A/C suitable for HPSV lamp from 70 to 400W
S&F in replacement cable PVC insulated and PVC sheathed twin core 2.5 sqmm copper conductor multistranded with PVC conduit medium grade fixed to the poles by means of suitable size of clamps complete all as specified and directed.
S&F in replacement angle arm made out of GI pipe light grade 32/40mm dia 1.20 m length bend to shape 120 degree at one place suitable for fixing LED street light fittings fixed to pole/walls with help of MS clamp made out of flat iron of size 50 x 6 mm with suitable size of nut and bolts with two nos of washers duly painted complete all as specified and directed.
S&F in replacement of LED Street light luminaries fittings 60 watt green line a road lighting luminaries with high power LED and unique peanut to ensure uniform light distribution higher spacing between poles and maintenance free system Make-Crompton/Bajaj/ HPL- cat part No HPLLEDSL6060/Havells. Note:- (i) The contractor shall produce minimum two years warrenty against any manufactures defect/ failure of fitting from the authorised representative / OEM of the make as specified and brought at site. (ii) The Lux output shall not be less than 100 lumins per watt. (iii) The PF should be > 0.90 (iv) The LED street light fittings shall be provided with overload / under load protection with range 180 to 380 volts and inbuilt surge protection device. (v) The contractor / manufacture shall provide on site warranty for carrying out necessary repair / replacement of defective street light fittings. (vi) The LED fitting and driver in fitting shall be of same make.
S&F in replacement of LED flood light with high pressure die cast housing with IP 66 150 W LED flood light make :HPL/bajaj cat part No BJFL 150W LED/ Havells/Philips/Crompton.
S&F cable PVC insulated, heavy duty electric cable with aluminium conductor, 1100 Volts grade, Cross –sectional area 16 Sqmm 4 Core.
Excavation in trenches not exceeding 1.5mtr wide & not exceeding 1.5 mtr in depth for laying cable, hard/loose soil complete all as directed.
Returning, filling in trenches with soil, including spreding, leveling, watering & well ramming, in layers not exceeding 25 cm each complete
Removing surplus excavated material (soil) to distance not exceeding 50 Mtr & depositing where directed at level not exceeding 1.5 mtr above the starting point.
Sand filling in cable trenches for cable protection with clean dry sand unwashed including gently put in trench
S&F for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.
S & F in replacement LED Post top Larnten 36 Watt complete all as specified and directed.
S & F Timelite distribution boards 40 A 3 pole /230 V Astronomical time switch ,MS sheet metal enclosure factory made, weather proof with locking arrangement and painting with synthetic enamel paint complete and fixed with angle iron frame of size 40 x 40 x 5 mm with suitabale size of nut and bolts etc .
M/S VIKAS CONSTRUCTION CO.
Raj Construction
india trading company
M/s Dwarika Nath Singh
BHARATI ENTERPRISES
M/S JAI MATA DEE CONTRUCTION CO.
M/S ABDHESH CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .