| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹35.9 LAccepted-AOC NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | 1 | Accepted-AOC BEING LOWEST TENDERER AND FULFILLING ALL THE REQUISITE CRITERIA | |
| 2 | 2₹42.0 L+₹5.7 L (15.8%)Rejected-Finance NO 2C THANGAVEL VAITHIYAR STREET TRIPLICANE CHENNAI 600 005 | CHENNAI | CHENNAI | TAMIL NADU | 600005 | 2 | Rejected-Finance NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹42.0 L+₹5.8 L (16.0%)Rejected-Finance 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | 3 | Rejected-Finance NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹43.4 L+₹7.2 L (19.8%)Rejected-Finance 93 SRP KOVIL STREET PERAVALLUR CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | 4 | Rejected-Finance NOT BEING THE LOWEST TENDERER |
Tender Value
₹46.2 L
EMD Value
₹92,500
Closing Date
28 Jul 2023, 6:00 pmClosed
GE CHENNAI
GARRISON ENGINEER FORT ST GEORGE CHENNAI 600009
SPECIAL REPAIRS TO BUILDING NO.IV PORTION OF 1st FLOOR (1250 A DSC PL LIVING ACCN) OF EMB HQ UNDER GE CHENNAI
2023_MES_607249_1
8656
Open Tender
Civil Works
Item Rate
274 days
GE CHENNAI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE CHENNAI
₹92,500
Yes
26 Aug 2023
30 Jun 2023
4 Aug 2023
30 Jun 2023
28 Jul 2023
14 Jul 2023
Amount
Complete removal of existing roof treatment any type and demolition of cement concrete padding at roof slab n exc 15cm thickness complete all specified and directed.
Plain cement concrete 40mm thick average thickness as roof padding type B0, 1:2:4 (12.5mm graded aggregate) finished fair and even over concrete surface on roof top, and finished even and smooth with 10mm thick cement plaster in CM 1:4 mixed with WPC @ 200 ml per bag, when the concrete is green all as per manufacturer instructions complete all specified and directed. ( Note: Water proofing compound will be paid under measured seperately)
Supply only Liquid water proofing compoud
Cleaning and preparation of newly plasteres roof surfaces and applying the water proofing treatment as under. (a) Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on roof surfaces complete all as specified and directed.
Taking down of existing cement or lime plaster alongwith the existing water proofing treatment on walls and applying 10 mm thick cement plaster 1:3 ( mixed with liquid Water Proofing Compound, cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under. (a) Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floor 150mm dia with steel clamps at 2.0 mtr C/C incl taking down of old pipes complete all as specified and directed.
PVC ( SWR) bend any radius 150mm dia all as specified and directed.
Making good of cornices architectural matching with existing views at Rain water pipes cutting portion cutting channels, grooves exc 15cm n exc 30cm girth and making good by PCC 1:2:4 or Cement mortar 1:3 whatever suitable for site complete all as specified and directed.
Taking down lime plaster on brick or stone wall surfaces including raking out joints hacking for kety, scrubbing down with water etc complete all as specified and directed.
Rendering 15mm thick in cement plaster in 1:4 on fair surface of brick/concrete wall surfaces with finished even and smooth complete all as specified and directed.
Rendering 15mm thick in cement plaster in 1:6 on fair surface of brick/concrete wall surfaces with finished even and smooth complete all as specified and directed.
Rendering 10mm thick cement plaster in 1:3 Mix on fair surfaces of brick/concrete ceiling surfaces with finished even and smooth as ceiling plaster complete all as specified and directed.
preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
Preparation of newly plastered surface applying two coats of wheather proof paint ( APEX of approved shade) over a coat of white primer complete all as specified and as directed.
Preparation of newly plastered wall surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer over 2 to 3mm thick wall care putty complete all as specified as directed.
Complete removal of existing treatment of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer paint on old wall surfaces over 2 to 3 mm thick wall care putty finish complete all as specified and as directed.
Complete removal of existing treatment and washing with water and bleaching powder, applying two coats of weather proof paint ( APEX of approved shade) over a coat of white primer incl 2 to 3 mm thick putty finish preparation of old plastered surfaces complete all as specified and as directed.
Applying one coat of synthetic enamelled paint including preparation of old treated steel surfaces of any description not otherwise described over 10 CM girth or width complete all as specified and as directed.
Applying one coat of synthetic enamel paint including preparation of old treated wood surfaces of any description not otherwise described over 10 CM girth or width all as specified and as directed.
Preparation of old plastered surfaces of wall surfaces and applying one coat of white wash complete all as specified and directed
Preparation of old plastered surfaces of ceiling surfaces and applying one coat of white wash complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not other wise provided complete all as specified and directed.
Cutting holes into or through brickwall built in CM and making good in CM 1:3 or cement concrete 1:2:4 type B-1 as required of superficial area 150 Sqcm but n.exc 400 Sqcm complete all as specified and directed
Rolled mild steel joist channels, angles or tee sections , fixed independently without connecting plates etc as in Madras Terrace roof of Fe-410-W (gde-E-250) Quality B complete all as specified and directed
Two coats of synthetic enamel painting over a coat of red oxide primer on previously untreated new steel surface of any description over 10cm in width or girth not otherwise described complete all as specified and directed
PCC 1:2:4 type B-1 as in roof kerbs levelling course finishing the surface by even and rough for receiving floor finishes complete all as specified and directed.
Demolition of brick masonary built in cement mortar including all quoins arches, pillars etc but including ashlars facing dressed stoe work and pre cast concrete articles complete all as specified and directed.
Brickwork with fly ash bricks, straight or curved on plan exc 6M mean radius built in Cm (1:6) complete all as specified and directed.
Brickwork with flyash bricks, straight or curved on plan to any radius in half brick walls built in Cm (1:4) complete all as specified and as directed.
Rendering in CM 1:6, 15mm thick on fair faces of brick/concrete surfaces finishes even and smooth without using extra cement complete all as specified and directed.
Taking down shutters of any description exc 2 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking of shutters from the frame) of any description alongwith fittings exc 1.5 Sqm and n exc 4 Sqm each complete all as specified and as directed.
S&F 2nd class hardwood plain solid straight chowkats and frames wrought, framed, rebated on solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
2nd class hardwood panelled shutters 35mm thick, plain framed ( any no of panels) with panels of timber flat on both sides ( feather edged) or 12mm veneered particles boards commercial veneering on both faces the size of rail and stile as per IS :1003 (Part-I), kiln seasoned and chemically treated and fitted to chowkats complete all as specified and as directed
2nd class hardwood glazed and skelton shutters 35mm thick divided into squares open rebated and prepared to receive glass guage etc edges of framing plain, chamfered, rounded fitted with mitred beads for securing glass etc size of members as specified in SSR Pt I section clause 8.24(a) supplied and fitted to chowkats with plain, chamfered or rounded mited and rebated bars any numbers complete all as specified and directed.
2nd class hardwood glazed and skelton shutters 35mm thick divided into squares open rebated abd prepared to receive glass guage etc edges of framing plain, chamfered, rounded fitted with mitred beads for securing glass etc size of members as specified in SSR Pt I section clause 8.24(a) supplied and fitted to chowkats with plain, chamfered or rounded mited and rebated bars any numbers complete all as specified and directed.
Alumnium anodised barrel tower bolts of extruded section 200mm long complete all as specified and directed.
Alumnium anodised barrel tower bolts of extruded section 150mm long complete all as specified and directed.
Extruded aluminium alloy handles fabricated type anodised 150 mm size complete all as specified and directed.
Extruded aluminium alloy handles fabricated type anodised 125 mm size complete all as specified and directed.
Mild steel Butt hinges, medium weight cold rolled 75 mm size ISI marked complete all as specified and directed.
Mild steel Butt hinges, medium weight cold rolled 100mm size ISI marked complete all as specified and directed.
Sheet glass 4mm thick plain ordinary quality and glazing with oil putty wooden beads as directed in squares n. exc. 0.50 Sqm in each pane complete all as specified and directed.
Alumnium alloy wire mesh 0.45mm nominal dia of wire and avarage width of aperature 1.40mm and fixed with alumnium wire staples complete all as specified and as directed.
Alumium alloy wire 0.45mm nominal dia of wire and avagre width of aperture 1.40 and fixed with alumnium wire staples complete all as specified and as directed.
2nd class hardwood fillets exc 13 & n .exc 25 Sq.cm in square, rectangular in section clean sawn secured with nails or screws etc complete all as specified and as directed.
Expanded metal cut to length, bent to shape required and tying with and incl annealed MS wire not less than 0.9mm dia or fixing with galvanised steel staples suplied and fixed complete to wood or steel members weight per sqm exc 4 kg complete all as specified and as directed.
Applying two coats of alumnium paint over a coat of alumnium primer including preparation of new steel surfaces of any description not otherwise described over 10cm grith or width complete all as specified and as directed.
Alumnium alloy anodised sliding door bolts 300mm long with hasp, staple ( bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast alumium alloy complete all as specified and directed.
Preparation of new wood surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Framed work such as grills gratings etc with ends of bars shouldered and or riveted or forged into spikes frames guard bars barred iron door ladders framed balusters walk ways railing framed work of water tanks and similar works conforming to Fe-290 grade E 165 complete all as specified and as directed.
M&L for mild steel work in bands, straps, supports of stays, sunshade brackets, hook and spintle hinges, clamps, hold fasts, guard bars, grills bolts etc and similar conforming to FE-290, Gde E 165 complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semicorrugated etc) sheet in roof covering complete all as specified and directed.
Roof trusses ( framed) trussed purlin, crane gantries, rails and fastenings and heavy bracket ( Bem, tee, angle, channel or flat sections including distance pieces, cleats etc complete all as specified and directed.
Pre painted/ galvalume alumnium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement bedding ( but not backing) removing serviceable tiles to stores and rubbish off the premises complete all as specified and directed.
Screed bed in CM 1:4 10mm thick for laying floor finisheds complete all as specified and directed.
Non skid ceramic light shade tile 7 to 8mm thick ( square or rectangular) area of each tiles exceeding 0.11 Sqm and not exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over complete all as specified and directed.
Non skid ceramic light shade tile 7 to 8mm thick ( square or rectangular) area of each tiles exceeding 0.06 Sqm and not exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over complete all as specified and directed.
Backing coat in CM 1:3, 10mm thick on verticle surfaces as skirting/Dado/Riser to steps around pillars complete all as specified and directed.
Cloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match dado complete all as specified and directed.
Dismantling of wall and ceiling boards ( fibre pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed.
Galvanised powder coated snap grid framework of size 605 x 605mm for false ceiling all as specified including vinyl laminated MPL gypsum panels ( GYPTECH) 9mm thick of size 60 x 60 cm fixing with stapples on snap grid by means of GI wires not less than 4mm dia hooks and raw plug etc centre of make: GYPTECH /ARMSTRONG complete all as specified and as directed.
Three layer rotational moulded water storage tank ( cylindrical, vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I, 1000 ltr capacity including dismantling existing PVC OHT complete all as specified and directed.
Three layer rotational moulded water storage tank ( cylindrical, vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I, 500 ltr capacity including dismantling existing PVC OHT complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20mm bore pipe complete all as specified and directed.
Galvanised steel tubing of 20mm bore medium grade with all fittings and fixed completed to wall and ceiling or laid in floor complete all as specified and directed.
PVC connection 15mm size with PTMT nuts of length 600mm long complete all as specified and directed.
PVC Low level flushing cistern 10 Ltr capcity with complete accessories PVC Flush pipe over flow pipe compete in repairs all as specified and as directed.
Bib taps 15mm dia cast fancy CP copper alloy crutch or butterfly handle screwed down, screwed for iron pipes or for brass ferrule and fixed in repairs complete all as specified and directed.
Brass stop valves 15mm dia CP fancy type with screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union fixed in repairs complete all as specified and directed.
Pillar taps 15 mm fancy type, cast copper alloy with capston heads, CP with screwed down, high pressure with of without lettered hot or cold with long body fixed in repairs complete all as specified and as directed.
Vitreous China ware wash hand basin white flat back size 580 x 450mm incl brackets and 32mmm waste coupling and waste pipe fixed in repairs complete all as specified and as directed.
Towel rail 600mm long PTMT fixed with end incl CP Brass screws and wooden/plastic cleats ( Minium wt 190 Gms) complete all as specified and as directed.
PVC (SWR) floor trap,plain with grating incl jointing with solvent cement outlet of pipe of 75mm dia complete all as specified and directed.
75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed.
110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed.
Ball valves suitable for 20mm dia pipes high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed ( Minium weight 15mm-142 gms/20mm-210 gms/25mm-455gms/40mm-690gsm)as in repairs complete all as specified and directed.
Hardcore of guage exe 63mm and not exc 100mm, deposited, spread and levelled in layers n exc 15 cm thick watered and rolled/rammed to a true surface of broken stone boulders complete all as specified and directed.
PCC 1:3:6 type C2, 50mm thick ( using 40mm graded stone aggregate) as in Path/plinth protection/footpath etc complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling rose, pendant, regulator sockets etc., to be measured separately) removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.all as specified and as directed.
Point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cabel of 1100V grade drawn through new non metallic rigid PVC conduit including accessories, concealed in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing the switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly including taking down old point wiring complete all as specified and directed by Engr-in-Charge.
One light point controlled by one switch.
One fan point controlled by one switch.
One bell/buzzer point controlled by one bell push
One 3 pin switch socket outlet, 5 Amps on same board controlled by one switch.
One 3 pin switch socket outlet, 5 Amps on independent board controlled by one switch.
One socket outlet 3 pin 15 Amps controlled by one switch independent board with cable 2.5 Sqmm size. (Two run ) and 2.5 Sqmm (one run) all as specified and as directed.
M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through non metallic rigid Existing PVC conduit , concealed in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing the switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly including taking down old point wiring complete all as specified and directed by Engr-in-Charge.
One light point controlled by one switch.
One fan point controlled by one switch.
One bell/buzzer point controlled by one bell push
One 3 pin switch socket outlet, 5 Amps on same board controlled by one switch.
One 3 pin switch socket outlet, 5 Amps on independent board controlled by one switch.
One socket outlet 3 pin 15 Amps controlled by one switch independent board with cable 2.5 Sqmm size. (Two run ) and 2.5 Sqmm (one run) all as specified and as directed.
Modular metal flush box 2 module complete all as specified and directed by Engr-in-Charge
Modular metal flush box 4 module complete all as specified and directed by Engr-in-Charge
Modular metal flush box 6 module complete all as specified and directed by Engr-in-Charge
Modular cover plate with frame 2 module complete all as specified and directed by Engr-in-Charge
Modular cover plate with frame 4 module complete all as specified and directed by Engr-in-Charge
Modular cover plate with frame 6 module complete all as specified and directed by Engr-in-Charge
Modular switches suitable for type AC 240V, 6 amps 1 module complete all as specified and directed by Engr-in-Charge
Modular sockets suitable for type AC 240V, 6 amps 2 module complete all as specified and directed by Engr-in-Charge
Modular switches suitable for type AC 240V, 16 amps 1 module complete all as specified and directed by Engr-in-Charge
Modular power sockets suitable for type AC 240V, 16 amps 2 module complete all as specified and directed by Engr-in-Charge
Modular fan regulator suitable for type AC 240V, 2 module complete all as specified and directed by Engr-in-Charge
Modular bell switch suitable for type AC 240V, 16 amps complete all as specified and directed by Engr-in-Charge
Call bell of multi music type A/C 230 volts complete all as specified and directed by Engr-in Charge
S&F ceiling rose, polycarbonate, isolated body with 2 to 3 terminals complete all as specified and directed.
Taking down complete LED fittings any type and any size complete all as specified and directed by Engr-in-Charge .
Ceiling fans with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep complete and old fan deposit to E/M yard complete all as specified and directed.
Taking down and re fixing for ceiling fans after repair complete including painting and re winding and accessories, 230 V, 1200 /1400 mm sweep after disconnecting the electric connection and re-connecting the fans to ceiling rose/connector after necessary servicing complete all as specified and directed by Engr-in Charge
Exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete and old fan deposit to E/M yard complete all as specified and as directed.
Taking down and re fixing for Exhaust fans after repair complete including painting and re winding and accessories, 230 V, up to 450 mm mm sweep after disconnecting the electric connection and re-connecting the fans to ceiling rose/connector after necessary servicing complete all as specified and directed by Engr-in Charge
Lamp holder insulated body with back plate for batten fittings/angle holder as required and including taking down old damaged holder complete all as specified and directed.
LED bulb 9 w high sutable for lamp holder complete complete all as specified and as directed by the Engineer-in-Charge. Make : Havells/CG/Philips /Wipro
20 Watts LED light fitting, basic all purpose surface and wall mounted LED batten 20Watts with aluminium housing and integrated electronic driver including 20W LED tube - 1No on surfaces of wall or ceiling including taking down the old fitting complete all as specified and as directed by the Engineer-in-Charge Make Crompton Cat No CCS-103-20-65-SL-DP-NWH or equivalent to /Philips /Wipro/Havells
Taking down and re fixing for LED tube light any type and any make complete for servicable with good condition complete all as specified and directed by Engr-in Charge
10Watts LED light fitting, basic all purpose surface and wall mounted LED batten 10Watts with aluminium housing and integrated electronic driver including 20W LED tube - 1No on surfaces of wall or ceiling including taking down the old fitting complete all as specified and as directed by the Engineer-in-Charge Make Crompton Cat No CCS-103-10-65-SL-DP-NWH or equivalent to /Philips /Wipro/Havells
36 Watts 2X2 ceiling light Environment friendly, new generation, aesthatically, ultra modern designed Recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong/Grid ceiling complete all as specified and as directed by the Engineer-in-Charge Make Crompton Cat No LCTLRF7-36-CDL or equivalent to /Philips /Wipro/Havells
Taking down complete sub main wiring any type and any size complete all as specified and as directed by the Engineer-in-Charge
Sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling and including existing sub main wiring taking down complete with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed by Engr-in-Charge. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Sub main wiring complete with two runs of 6 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling and including existing sub main wiring taking down complete with one run of 6 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed by Engr-in-Charge. Note:- Two runs of PVC insulated cable 6 sqmm + one run 6 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Sub main wiring complete with two runs of 6 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid Existing PVC conduit on wall alongwith accessories fixed on walls/floors/ceiling with one run of 6 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed by Engr-in-Charge. Note:- Two runs of PVC insulated cable 6 sqmm + one run sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 4 way MCCB DB, TPN with 200 Amp rated bus bar shall conform to IP 38 protection incluidng taking down the old one.
MCCB 415V, 4 pole 50HZ fixed thermal setting of capacity 100 Amps 16 KA including taking out old u/s one all as specified and as directed.
S&F MCCB single pole of rating SPN 40 Amps complete including taking down the old unserviceable all as specified and as directed.
MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 240volt 8 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection incluidng taking down the old one complete all as specified and directed.
MCB of rating 240 Volts,SPN 40 Amps including taking down the old one complete all as specified and directed.
MCB of Single pole of rating 6 to 32 Amps including taking down the old one complete all as specified and directed
Modular 32 Amp motor starter AC switch with two module one piece including indication both red and green complete including taking down the old one complete all as specified and directed
Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc and old geyser deposite to E/M Yard complete all as specified and directed by Engr -in charge.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 95 sqmm x 3.5 core with glands, cable protection pipes, cable route indicator etc., complete from the trenches/fixed on wall (or) passing through pipes/in floor removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors on wall with suitable clamp, fixing screw etc and connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 95 sqmm 3.5 core complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected upto switch board incl 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including dearth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete all as specified inlcuding testing on completion all as specified and as directed.
M/SJAYAM CONSTRUCTIONS
SIRITEL SYSTEMS PRIVATE LIMITED
JANANIKARTHIK ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .