Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹1.8 Cr | L1 | Accepted-AOC Lowest bidder. |
| 2 | L2₹1.9 Cr+₹44,975 (0.24%)Rejected-Finance | ₹1.9 Cr+₹44,975 (0.24%) | L2 | Rejected-Finance Not a Lowest bidder. |
| 3 | L3₹1.9 Cr+₹91,259 (0.49%)Rejected-Finance | ₹1.9 Cr+₹91,259 (0.49%) | L3 | Rejected-Finance Not a Lowest bidder. |
| 4 | L4₹1.9 Cr+₹2.9 L (1.59%)Rejected-Finance | ₹1.9 Cr+₹2.9 L (1.59%) | L4 | Rejected-Finance Not a Lowest bidder. |
| 5 | L5₹1.9 Cr+₹8.0 L (4.30%)Rejected-Finance | ₹1.9 Cr+₹8.0 L (4.30%) | L5 | Rejected-Finance Not a Lowest bidder. |
Tender Value
₹2.2 Cr
EMD Value
₹4.3 L
Closing Date
14 Feb 2020, 6:00 pmClosed
AGM (Engg.-E)-II, AAI DABH Airport, Indore.
O/o Airport Director , AAI DABH Airport, Indore.
ARMO of 33KV Sub Station i/c Internal and External installations of NITB, Fire Fighting and Alarm System, 140KLD STP etc. at DABH Airport, Indore for 02 (Two) years.
2019_AAI_38705_2
AAI/ID/ENGG(E)/NIT- 12/NITB ARMO/2019-20
Open Tender
Electrical Works
Works
730 days
Indore Airport.
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,180
Yes
Airports Authority of India
₹4.3 L
Yes
7 Jul 2022
3 Feb 2020
20 Feb 2020
4 Feb 2020
14 Feb 2020
4 Feb 2020
4 Feb 2020 - 10 Feb 2020
Amount
Operation & daily routine Maintenance of various HT & LT E&M installations of NITB, 140 KLD Sewage Treatment Plant, Fire Alarm & Fire Fighting Systems, 33KV Sub-Station etc. with associated accessories in 03(three) shifts per day (24 hrs), on all days including Sundays & Holidays. The job includes carrying out preventive / break down maintenance activities as per the scope of work mentioned in the special conditions of contract and technical specifications, complete as required.
a) For 1st Year
b) For 2nd Year
Deployment of following additional manpower at site for carrying out various operation and maintenance works to meet the actual site / operational requirements etc., as and when required:-
Electrician / Operator (Skilled)
Helper (Un-Skilled)
Complete rewinding of the motor of following capacity Sewage / Drainage Submersible Pump Set of various makes & models i/c dismantling, transportation from site to work shop & work shop to site assembling, testing and commissioning etc. complete as required.
3 Phase, 7.5 HP a) For 1st Year
3 Phase, 7.5 HP b) For 2nd Year
3 Phase, Greater than 01 HP & upto 3 HP a) For 1st Year
3 Phase, Greater than 01 HP & upto 3 HP b) For 2nd Year
3 Phase, Greater than 03 HP & upto 5 HP a) For 1st Year
3 Phase, Greater than 03 HP & upto 5 HP b) For 2nd Year
3 Phase, Greater than 05 HP & upto 7.5 HP a) For 1st Year
3 Phase, Greater than 05 HP & upto 7.5 HP b) For 2nd Year
Complete rewinding of the motor of 3 Phase 7.5 HP Vertical Inline Multi Stage Hydro Pneumatic Centrifugal Pump Set of various makes & models i/c dismantling, transportation from site to work shop & work shop to site, assembling, testing and commissioning etc. complete as required.
a) For 1st Year
b) For 2nd Year
Complete rewinding of the motor of following capacity Monoblock Pump Set of various makes & models i/c dismantling, transportation from site to work shop & work shop to site, assembling, testing and commissioning etc. complete as required.:-
1 Phase, upto 1 HP a) For 1st Year
1 Phase, upto 1 HP b) For 2nd Year
3 Phase, upto 1 HP a) For 1st Year
3 Phase, upto 1 HP b) For 2nd Year
3 Phase, Greater than 01 HP & upto 3 HP a) For 1st Year
3 Phase, Greater than 01 HP & upto 3 HP b) For 2nd Year
3 Phase, Greater than 03 HP & upto 5 HP a) For 1st Year
3 Phase, Greater than 03 HP & upto 5 HP b) For 2nd Year
3 Phase, Greater than 05 HP & upto 7.5 HP a) For 1st Year
3 Phase, Greater than 05 HP & upto 7.5 HP b) For 2nd Year
3 Phase, 12.5 HP a) For 1st Year
3 Phase, 12.5 HP b) For 2nd Year
3 Phase, 75 HP a) For 1st Year
3 Phase, 75 HP b) For 2nd Year
Complete Servicing & overhauling of following capacity Sewage / Drainage Submersible Pump Set of various makes & models i/c replacement of defective parts, bush, bearings, mechanical seal etc., dismantling, transportation from site to work shop & work shop to site, assembling, testing and commissioning complete as required.
3 Phase, upto 1 HP a) For 1st Year
3 Phase, upto 1 HP b) For 2nd Year
3 Phase, Greater than 01 HP & upto 3 HP a) For 1st Year
3 Phase, Greater than 01 HP & upto 3 HP b) For 2nd Year
3 Phase, Greater than 03 HP & upto 5 HP a) For 1st Year
3 Phase, Greater than 03 HP & upto 5 HP b) For 2nd Year
3 Phase, Greater than 05 HP & upto 7.5 HP a) For 1st Year
3 Phase, Greater than 05 HP & upto 7.5 HP b) For 2nd Year
Complete Servicing & overhauling of following capacity Vertical Inline Multi Stage Hydro Pneumatic Centrifugal Pump Set of various makes & models i/c replacement of defective parts, bush, bearings, mechanical seal etc., dismantling, transportation from site to work shop & work shop to site, assembling, testing and commissioning complete as required.:- 3 Phase 7.5 HP
a) For 1st Year
b) For 2nd Year
Complete Servicing & overhauling of following capacity Monoblock pump Sets of various makes & models i/c replacement of defective parts, bush, bearings, mechanical seal etc., dismantling, transportation from site to work shop & work shop to site, assembling, testing and commissioning complete as required.:-
1 Phase, upto 1 HP a) For 1st Year
1 Phase, upto 1 HP b) For 2nd Year
3 Phase, upto 1 HP a) For 1st Year
3 Phase, upto 1 HP b) For 2nd Year
3 Phase, Greater than 01 HP & upto 3 HP a) For 1st Year
3 Phase, Greater than 01 HP & upto 3 HP b) For 2nd Year
3 Phase, Greater than 03 HP & upto 5 HP a) For 1st Year
3 Phase, Greater than 03 HP & upto 5 HP b) For 2nd Year
3 Phase, Greater than 05 HP & upto 7.5 HP a) For 1st Year
3 Phase, Greater than 05 HP & upto 7.5 HP b) For 2nd Year
3 Phase, 12.5 HP a) For 1st Year
3 Phase, 12.5 HP b) For 2nd Year
3 Phase, 75 HP a) For 1st Year
3 Phase, 75 HP b) For 2nd Year
Complete Servicing, Repairing & Overhauling of following capacity Twin Lobe Rotary Air Blower of capacity 216 cubic mtr / hour at 0.4 Kg / Sq.Cm pressure & compatible with V-belt drive of 7.5 HP, 1440 rpm 3 Phase Induction Motor i/c replacement of defective parts, bush, bearings, mechanical seal etc., dismantling, transportation from site to work shop & work shop to site, assembling, testing and commissioning complete as required. (Make - Usha, Model - UGRK-140SR)
a) For 1st Year
b) For 2nd Year
Regeneration of Water Softner Plant of STP having Brine Water Tank Capacity of 500 Ltrs, by supplying & topping up of Rock Salt / Common Salt @ 50 Kg per regeneration, on Monthly basis, or as per direction of Engineer-in-Charge, complete as required.
a) For 1st Year
b) For 2nd Year
Providing & fixing of Filter press cloth for 140 KLD STP plant i/c dismentling of old filter press cloth as required.
a) For 1st Year
b) For 2nd Year
Testing of Treated Water Sample of STP through MP Polution Control Board / NABL accredited Laboratories and submission of Test Reports for following parameters, at regular interval of every 06(Six) months, or as per direction of Engineer-In-Charge, complete as required :- Colour, Odour, PH Value, TDS, TSS, BOD, COD, Oil & Grease etc.
a) For 1st Year
b) For 2nd Year
Chemical Dosing of 140 KLD STP through suitable means by providing minium following quantity of chemicals, as per direction of Engineer -in-charge, complete as required :-
Sodium Hypo Chlorite (Approx. Min. Qty.= 1.5 Ltr Per Day) a) For 1st Year
Sodium Hypo Chlorite (Approx. Min. Qty.= 1.5 Ltr Per Day) b) For 2nd Year
Lime Powder (Approx. Min. Qty. = 9 Kg Per Day) a) For 1st Year
Lime Powder (Approx. Min. Qty. = 9 Kg Per Day) b) For 2nd Year
Alum Powder (Min approx. Qty. = 7 Kg Per Day) a) For 1st Year
Alum Powder (Min approx. Qty. = 7 Kg Per Day) b) For 2nd Year
Poly Electrolite (Approx. Min. Qty = 150 Gram per day) a) For 1st Year
Poly Electrolite (Approx. Min. Qty = 150 Gram per day) b) For 2nd Year
Rewinding, repairing and overhauling of following types of fans by using suitable gauge enamel copper wire, backing, oiling, greasing including replacement of capacitor, bush, bearing, shaft etc, complete, as required
Ceiling fan (1200 mm to 1400mm sweep) a) For 1st Year
Ceiling fan (1200 mm to 1400mm sweep) b) For 2nd Year
Wall Fan ( 300mm to 450 mm sweep) a) For 1st Year
Wall Fan ( 300mm to 450 mm sweep) b) For 2nd Year
Exhaust fan (300 to 450mm sweep) a) For 1st Year
Exhaust fan (300 to 450mm sweep) b) For 2nd Year
Supplying and Making Straight Through cable jointing with heat shrinkable jointing kit complete with all accessories including ferruls suitable for 3 x 300 Sq.mm XLPE aluminium conductor cable of 33 KV grade as required
a) For 1st Year
b) For 2nd Year
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 x 300 Sq.mm XLPE aluminium conductor cable of 33 kV grade, as required.
a) For 1st Year
b) For 2nd Year
Painting with one or more coats of spray painting with synthetic enamel paint of approved colour, brand and manufacture to give an even shade including cleaning of surface, on old work / electrical panels & installations, as required.
a) For 1st Year
b) For 2nd Year
Visit charges of Service Engineer from the Manufacturer or Authorised Service Dealer or Specialised Agency for carrying out Minimum 01(One) Half Yearly Preventive Maintenance visit for satisfactory working condition of the system including providing & upgrading Software, if required (OR) Breakdown maintenance visit as and when required basis till the complete rectification of the breakdown irrespective of number of visits to attend the same breakdown (but excluding cost of Spares / Hardware required, if any).
DG Sets Syncronizing Panel comprising of Auto Load Sharing and Load Managing Panel, Main Change Over Panel, PLC etc. at NPH (Make - Zeta Industrial Corp. Pvt Ltd.) a) For 1st Year
DG Sets Syncronizing Panel comprising of Auto Load Sharing and Load Managing Panel, Main Change Over Panel, PLC etc. at NPH (Make - Zeta Industrial Corp. Pvt Ltd.) b) For 2nd Year
Vertical Inline Multi Stage Hydro Pneumatic Centrifugal Pump Set (3No. X 7.5HP) with Electrical Panel at NPH (Make - Grundfos ) a) For 1st Year
Vertical Inline Multi Stage Hydro Pneumatic Centrifugal Pump Set (3No. X 7.5HP) with Electrical Panel at NPH (Make - Grundfos ) b) For 2nd Year
7 Loop intelligent analogue addressable, expandable, networkable Fire Alarm Control Panel at NITB. Dongal for updating / editing / adding / disabling of devices etc shall be arranged by the contractor (Make- Honeywell, Model - XLS -1000):- a) For 1st Year
7 Loop intelligent analogue addressable, expandable, networkable Fire Alarm Control Panel at NITB. Dongal for updating / editing / adding / disabling of devices etc shall be arranged by the contractor (Make- Honeywell, Model - XLS -1000):- b) For 2nd Year
2 Loop analogue addressable, Fire Alarm Control Panel at OTB (Make- Notifier, Model - NFS -3030) a) For 1st Year
2 Loop analogue addressable, Fire Alarm Control Panel at OTB (Make- Notifier, Model - NFS -3030) b) For 2nd Year
6 Zone, Microprocessor based Fire Alarm Control Panel with Auto Dialer Facility, installed at following sites (Make- Agni Suraksha / System Sensor) :- i) GP ii)LLZ iii) DVOR iv) NDB v) TECH BLOCK. ( Note - Quoted Rates shall be per site basis) a) For 1st Year
6 Zone, Microprocessor based Fire Alarm Control Panel with Auto Dialer Facility, installed at following sites (Make- Agni Suraksha / System Sensor) :- i) GP ii)LLZ iii) DVOR iv) NDB v) TECH BLOCK. ( Note - Quoted Rates shall be per site basis) b) For 2nd Year
Collection of Transformer Oil sample from Transformers of different capacities at site and testing the same from authorised testing laboratory and submission of test report for following parameters, complete as required :- (i) Acidity Test (ii) Flash Point Test
a) For 1st Year
b) For 2nd Year
Dehydration & Filtration of Transformer Oil at site including Testing of Transformer Oil B.D.V Test before and after Filtration for Transformers of following capacity. The job includes transportation of Filtration Machine etc. at site and submisstion of Test Reports, complete as required:- (i) 3 x 1600 KVA, 33/0.433 KV, and (ii) 1 x 750 KVA, 33/11 KV
a) For 1st Year
b) For 2nd Year
Supply of brand new Transformer oil suitable for 1600 KVA, 33 KV/11 KV Power Transformers alogwith Test Reports of oil.
a) For 1st Year
b) For 2nd Year
Inspection, Repairing, Servicing, Overhauling and Testing of following GE / C&S / ABB make Air Circuit Breakers from Manufacturer or Authorised Service Dealer or Specialised Agency and submisstion of Test Report etc., complete as required.
1000/1250/1600 Amps a) For 1st Year
1000/1250/1600 Amps b) For 2nd Year
2500 Amps a) For 1st Year
2500 Amps b) For 2nd Year
Inspection, Servicing / Overhauling and Testing of following Jyoti Make HT Panels from Manufacturer or Authorised Service Dealer or Specialised Agency and submisstion of Test Report etc., as required.
33 KV Panel consisting of 33 KV VCB. a) For 1st Year
33 KV Panel consisting of 33 KV VCB. b) For 2nd Year
11 KV Panel consisting of 11 KV VCB a) For 1st Year
11 KV Panel consisting of 11 KV VCB b) For 2nd Year
Checking, Servicing, Callibration & Testing of protection relays provided on 5(Five) nos. 33 KV VCB panels from Manufacturer or Authorised Service Dealer or Specialised Agency and submisstion of Test Report etc. as required. a) IDMT O/C & Earth fault relays (3 OC + 1 EF) - 05 Set b) Master Trip Circuit relay - 05 Nos. c) Trip Ckt Supervision relay - 05 Nos. d) Under / Over Voltage Protection Relay - 01 No. e) Restricted Earth Fault relay - 04 Nos. f) Bulchhoz relay trip / alarm, Winding Temp. trip / alarm, Oil Temp. trip/alarm, OSR trip/ alarm, MOG alarm - 03 Set.
a) For 1st Year
b) For 2nd Year
Checking, Servicing, Callibration & Testing of protection relays provided on 1 (One) no. 11 KV VCB panels from Manufacturer or Authorised Service Dealer or Specialised Agency and submisstion of Test Report etc. as required. a) IDMT O/C & Earth fault relays (3 OC + 1 EF) - 01 Set b) Master Trip Circuit relay - 01 Nos. c) Trip Ckt. Supervision relay - 01 Nos. d) Auxilary relay for transformer protect -1 No. e) Aux relay for transformer neutral - 1 No.
a) For 1st Year
b) For 2nd Year
Checking, Callibration & Testing of Voltmenetr, Ammeter, Multifunction meter provided on different HT Side panels from manufacturer or Authorised Service Dealer or Specialised Agency and submisstion of Test Report etc. as required. a) Digital Ammeter -06 Nos. b) Digital Voltmeter - 02 Nos. c) Digital Multifunction Meter - 03 Nos.
a) For 1st Year
b) For 2nd Year
Checking, Callibration & Testing of Voltmenetr, Ammeter, Multifunction meter provided on different MV/LT side panels panels from manufacturer or Authorised Service Dealer or Specialised Agency and submisstion of Test Report etc. as required. a) Digital Ammeter -65 Nos. b) Digital Voltmeter - 66 Nos. c) Analog Voltmeter - 04 Nos. d) Digital Multifunction Meter - 52 Nos.
a) For 1st Year
b) For 2nd Year
Service Contract for Kirloskar Make Diesel Engine Set (Type : 4R1040TA) of Capacity 105 HP by providing 'B' Check Maintenance Kit comprising of following spares / materials compatible with the above Engine and of makes as specified by OEM of the engine including carrying out 'B' Check Maintenance at an interval of every 06(six) months or as per OEM schedule:-
Lube Oil ( 20W40) a) For 1st Year
Lube Oil ( 20W40) b) For 2nd Year
Oil Filter a) For 1st Year
Oil Filter b) For 2nd Year
Pre Diesel Filter a) For 1st Year
Pre Diesel Filter b) For 2nd Year
Micro Diesel Filter a) For 1st Year
Micro Diesel Filter b) For 2nd Year
Air Filter a) For 1st Year
Air Filter b) For 2nd Year
Designing, Manufacturing, Supplying & Fixing of Signage Vinyl pasting in Two Layers in approved colour & design on existing LED Signages at site including dismantling & removing the old Signages and refixing the new signage sheet, complete as required.
a) For 1st Year
b) For 2nd Year
Supply of following Electrical spares / materials as per approved makes, on as and when required basis, as per direction of Engineer -In-Charge:-
Intelligent addressable Photoelectric Smoke Detector with base, compatible with Honeywell make Fire alarm control Panel of Model - XLS-1000, ( Make - Honeywell, Model - XLS-PS or equivalent) a) For 1st Year
Intelligent addressable Photoelectric Smoke Detector with base, compatible with Honeywell make Fire alarm control Panel of Model - XLS-1000, ( Make - Honeywell, Model - XLS-PS or equivalent) b) For 2nd Year
Multi Criteria addressable Photoelectric Smoke / Thermal Detector with base, compatible with Honeywell make Fire alarm control Panel of Model - XLS-1000, ( Make - System Sensor, Model - 2351 TEM or equivalent) a) For 1st Year
Multi Criteria addressable Photoelectric Smoke / Thermal Detector with base, compatible with Honeywell make Fire alarm control Panel of Model - XLS-1000, ( Make - System Sensor, Model - 2351 TEM or equivalent) b) For 2nd Year
Electronic Hooter, made up of 16SWG CRCA sheet with PO Red colour powder coating as per IS 2189 ( Make - System Sensor or equivalent) a) For 1st Year
Electronic Hooter, made up of 16SWG CRCA sheet with PO Red colour powder coating as per IS 2189 ( Make - System Sensor or equivalent) b) For 2nd Year
Response Indicator in ABS body ( Make - System Sensor or equivalent) a) For 1st Year
Response Indicator in ABS body ( Make - System Sensor or equivalent) b) For 2nd Year
MCP in ABS Body ( Make - System Sensor or equivalent) a) For 1st Year
MCP in ABS Body ( Make - System Sensor or equivalent) b) For 2nd Year
Items as per CPWD Delhi Schedule of Rates (E&M) 2016 with upto date specifications, complete as required for a fixed amount as mentioned below:-
a) For 1st Year ( For a Fixed amount of Rs 1,00,000/- on DSR (E&M 2016) Rates)
b) For 2nd Year ( For a Fixed amount of Rs 1,00,000/- on DSR (E&M 2016) Rates )
ABHISHEK ASSOCIATES
N L Neema
CIS ELECTRICALS PVT LTD
S. N ELECTRICALS
R. D. ENGINEERS
Techno Electricals
PAN POLAR ENGINEERS PVT. LTD.
JAI ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .