Upgradation Of Second Floor Conference Hall At SIPRD Second Campus Kahikuchi Guwahati Civil work Electrical work Audio system and Visual System
2022_PNRD_27817_1
SIPRD/Tech/CS/20/2022/11
Open Tender
Civil Works
Works
240 days
SIPRD 2nd Campus Kahikuchi Guwahati
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,200
₹2.8 L
Yes
The Director Office, Khanapara, Guwhati-22
2 Mar 2023
18 Nov 2022
9 Dec 2022
23 Nov 2022
8 Dec 2022
1 Dec 2022
29 Nov 2022
Amount
AUDIO CONFERENCE SYSTEM
Supplying installation, testing, programming and commissioning of Audio equipment ON TABLE BOUNDARY MICROPHONE for any conferencing system: Frequency response 40 Hz – 20 kHz, Nominal impedance 200 Ω, Sensitivity 10 mV/Pa. Frequency Response :- 40 Hz - 20 kHz, Max. sound pressure level:- 140 dB, Sensitivity :- 10 mV/Pa, Dynamic range :- 111 dB(A) (Make:- Sennheiser/ Audio Technica/ Shure)
Supply, Installation, Testing and Commissioning of DSP core with 16 user configured card slots, Lua scripting engine, optional software-licensed HearClear AEC. (Make:- Xilica/ Biamp/ Clearone)
Supply, Installation, Testing and Commissioning of Analog Input Card having 2 Mic/ Line Inputs. (Make:- Xilica/ Biamp/ BSS)
Supply, Installation, Testing and Commissioning of Analog Output Card having 2 Mic/ Line Outputs. (Make:- Xilica/ Biamp/ BSS)
Supply, Installation, Testing and Commissioning of USB I/O Card (Make:- Xilica/ Biamp/ BSS)
Supplying installation, testing, programming and commissioning of Popup Box; Easy Access To Connectors, One Female 15pin HD Connector And 3.5mm Mini Stereo Audio Jack, Two CAT RJ45 Network/ Data/Phone Connectors, Two Unswitched AC Outputs, One HDMI 7 Nos 19500.00 136500.00 (Make:- Magnum/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of Audio equipment,8" Open-Back Ceiling Speaker. 70V/100V taps at 6W, 3W, 1.5W (plus 0.75W at 70V), very high 97 dB sense, 50 Hz to 16 kHz, for non-plenum applications, 1.4 kg (3.0 l.) (Make:- JBL/ Apart Audio/ Bosch)
Supplying installation, testing, programming and commissioning of 8Ch Power Amplifier. Signal to Noise Ratio (below rated power 20Hz to 20kHz, A?Weighted):- 110dB, Total Harmonic Distortion (THD) (full rated power, 20Hz - 20kHz):- <0.05%, ntermodulation Distortion (from 0dB down to -30dB):- <0.05%. (Make:- Crown/ Labgruppen/ Powersoft)
Supply, Installation, Testing and Programming of 11th Gen Intel Core i5 Processor 15.6 inches FHD Laptop, 8GB/512GB SSD/ Windows 10/2GB MX350 Graphics. (Make:- HP/ Dell/ Acer)
Supply and Laying of Audio Signal/ Microphone Cable (Make:- Gotham/ Klotz/ Belden)
Supply and Laying of Audio Speaker Cable (Make:- Gotham/ Klotz/ Belden/ Finolex)
Supply and Laying of 8 Core Audio Snake Cable (Make:- Gotham/ Klotz/ Belden)
Supply and Laying of Shilded Cat 6 Cable (Make:- Molex/ Panduit)
Supply and Installation of Shielded RJ 45 Connector
upply and Installation of Audio Connectors like XLR, RCA, Mono Jack etc (Make:- Amphenol/ Neutrik)
Supply and Installation of 17/18U Floor Mounted Equipment Rack (Make:- Nettrack/ Valrack/ LinkEu)
VIDEO CONFERENCE SYSTEM
Supplying installation, testing, programming and commissioning of 100" 4K Ultra HD HDR Professional Display. Brightness (cd/m2):- Typical: 600, Peak: 940, Contrast Ratio:- 9000:1, Backlight Type:- Direct LED, HDR Compatibility:- HDR10 / HLG / Dolby Vision. (Make:- LG/ Panasonic/ Sony)
Supplying installation, testing, programming and commissioning of 65" 4K Ultra HD HDR Professional Display. Brightness (cd/m2) Typical : 440, Contrast Ratio:- 1200:1, Dynamic Contrast Ratio:- 300,000:1, Panel Type (IPS / VA):-IPS, Backlight Type:- Direct LED. (Make:- LG/ Panasonic/ Sony)
Supplying installation, testing, programming and commissioning of 75" 4K Interactive Display. Panel Size: 75", Panel Type: TFT LCD Module with DLED Backlight, Display Area (mm): 1665.66 (H) x 944.73 (V) (74.5” diagonal), Aspect Ratio: 16:9, Resolution: UHD 3840x2160 (Pixels), Colors: 1.07B colors (10bit), Brightness: 350 nits (typ.), Contrast Ratio: 5000:1 (DCR), Response Time: 8ms, Viewing Angles: H = 178, V = 178 typ. (Make:- Viewsonic/ Panasonic/ LG)
Supplying installation, testing, programming and commissioning of 4K60 4:2:0 HDMI HDCP 2.2 Transmitter with RS–232 & IR over Long–Reach HDBaseT. INPUTS:- 1 HDMI on an HDMI connector, OUTPUTS:- 1 HDBT on an RJ–45 female connector, VIDEO:- Up to 10.2Gbps bandwidth (3.4Gbps per graphic channel), Up to 4K UHD @60Hz (4:2:0) 24bpp resolution (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 4K60 4:2:0 HDMI HDCP 2.2 Receiver with RS–232 & IR over Long–Reach HDBaseT. INPUTS:- 1 HDBT on an RJ–45 female connector, OUTPUTS:- 1 HDMI on an HDMI connector, VIDEO:- Up to 10.2Gbps bandwidth (3.4Gbps per graphic channel), Up to 4K UHD @60Hz (4:2:0) 24bpp resolution, HDCP 2.2 signal compliance (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 4K HDR HDMI Audio De–embedder. AUDIO: Frequency Response: 20Hz to 20kHz @ +/–0.1dB S/N Ratio: >90dB, THD+N: 0.004%, VIDEO: Bandwidth: Up to 18Gbps (6Gbps per graphic channel), Max. Resolution: Up to 4K@60 (4:4:4), HDMI Support: 4K@60Hz and ARC as specified in HDMI 2.0, Content Protection: Supports HDCP 2.2
Supplying installation, testing, programming and commissioning of 4x1 4K60 4:2:0 HDMI Auto Switcher with Audio. Max. Data Rate — 8.91Gbps (2.97Gbps per graphic channel), Max. Resolution — 4K@60Hz (4:2:0), Stereo analog audio per input, Balanced stereo analog audio output (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 1:8 HDMI Distribution Amplifier. Max. Data Rate — 6.75Gbps (2.25Gbps per graphic channel), HDTV Compatible, HDCP Compliant, HDMI Support — Deep Color, x.v.Color™, Lip Sync, CE, 3D Pass–Through. EDID Pass–through — Pass–through algorithm ensures Plug and Play operation for HDMI source and display systems, Equalization & re–Klocking™ Technology — Rebuilds the digital signal to travel longer distances. Active Output LED Indicators, Worldwide Power Supply — 100–240V AC. (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 1:4 4K HDR HDMI Distribution Amplifier. 1:4 HDMI distributor, Resolution — Up to 4K@60Hz (4:4:4), Bandwidth — Up to 17.82Gbps, Compliance — HDR10, HDCP 2.2 (Make:- Kramer/ Extron/ Atlona)
Supplying installation, testing, programming and commissioning of 22" Full HD Display Monitor. (Make:- BenQ/ Lenovo/ Viewsonic)
Supply and Installation of HDMI to HDMI Cable Length 15M (Make:- Kramer/ Extron/ Atlona)
Supply and Installation of HDMI to HDMI Cable Length 1M (Make:- Kramer/ Extron/ Atlona)
Supply and Installation of HDMI to HDMI Cable Length 5M (Make:- Kramer/ Extron/ Atlona)
DISMANTLING WORKS
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge in cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below
MASONRY WORKS:
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level cement mortar 1:3 (1 cement :3 coarse sand)
FINISHING
12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
FALSE CEILING
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595 x 595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance? 85%, Thermal Conductivity k=0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls/ partitions with the help of GI perimeter wall angle of size 24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting. 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
FLOORING
Providing and installing waterproof, anti-skid and chemical resistant SPC flooring having thicknness 4 mm, size 180mm x 1220mm (Plank).
ROLLER BLINDS
Supplying fitting and fixing of polyster/ cotton 0.6mm thick with blackout 3 pass foam coating blinds of approved colour, texture and pattern to the size of the opening including required extension in length and width. Prior approval should be obtained to finalize the design and pattern. Finished and complete in all respect as per the direction of the Engineer In Charge.
FLUSH DOOR
Supplying materials and making double shutter door in site or in factory with 35mm thick WPC flush door as the core with 6 mm thick ply board fixed both side with good quality adhesive and nails to obtain required design as per the approved drawing and specification. Both sides covered with 1mm thick laminates of approved colour and shade of reputed brand as per the pattern and design. A wooden bead of 40mmx 12mm should be fixed along the four edges of the door. Including fixing of all door hardware like H-type pull handle (two pairs), Concealed door closer (two sets), Door stopper (two numbers), Verti-bolt lock (one set), Hinge (three in each leaf) finished and complete in all respect as per the instruction of Engineer in charge. (Size:2000mm x2100mm)
Point wiring
Point wiring in PVC conduit, with modular type switch - Wiring for light point/ fan point/ exhaust fan point/ call bell point (for door call bell only ) with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Conduit Make : Anchor / Richa or equivalent as approved. Wires : FR /FRLS - Finolex, RR Kabel, Anchor, Havells or equivalent as approved. i)Group B
POWER POINT AND WIRING
Wiring for light/power plug with 2x2.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 2.5 Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required for common corridor and stair case lighting for 6 No. L P (having 1 nos. 5A switch and 1 nos. 5A socket)
Wiring for light/power plug with 2x2.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 2.5 Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required for common corridor and stair case lighting for 4 Nos. TV/ Computer POINT (having 2 nos. 5A switch and 2 nos. 5A socket)
Wiring for 15/16A light/power plug with 2x4 Sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 4 Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required in hall.
Wiring for Air Conditioner power supply to starter point with 2x6 Sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 6 Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required .Make : Anchor / Richa or equivalent as approved 2 Module (75mmX75mm) for AC STARTER power supply point
3 Module (100mmX75mm) for LP1- light power Point in hall
4 Module (125mmX75mm) for PP
6 Module (200mmX75mm) for LP2 - TV (5A 2nos Switch with 5A 2 nos. Socket)
12 Module (200mmX150mm) for V.I.P sitting area
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including conections but excluding modular plate etc. as required. Make : Havells/ Panasonic/ Schneider or equivalent as approved. 2 Nos. 5/6 amp modular switch for LP2 - TV Point.
2 nos. 5/6 amps modular socket for LP2- TV Point.
5/6 amp modular switch on existing Switch box for LP1
5/6 amps modular socket on existing Switch box for LP1
15/16 amps modular switch for PP
15/16 amps modular socket for PP
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. FOR CALL
Supplying and fixing call bell switch for service call in the existing SB , complete as required.
Circuit/ submain/ Light plug wiring in PVC conduit: - Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth from SB1 to call bell switch on the conference table.
2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire for light power points
2 x 6 Sq.mm + 1 x 6 Sq.mm earth wire for sub main for inverter power supply and from inverter to inverter DB
4 x 10 Sq.mm + 2 x 6 Sq.mm earth wire for sub main from MDB to TPN DB
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. 70.00 Sq. mm. 4 Core U.G. armoured cable
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required for service call indicating wires and TV co-axial cable inside only. Make : Anchor / Richa or equivalent as approved 20mm conduit for TV co-axial cable and speaker wiring system and power supply etc. as required to be laid on floor from respective point to conference table.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
POWER DISTRIBUTION BORD
Supplying and fixing of following ways surface/ recess mounting,VERTICAL type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs for out gogoing and MCCB for incomming . (but without MCBs and incomer) as required.- for each counter power distribution. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets BUT HERE IT WILL USE FOR SINGLE PHASE OUTLET FOR AC LOAD as required.) Make ; Havells, Panasonic, Schineider. as approved. 6 way (4 + 18), Double door for food counter and out door lighting power distribution. Having facility to install 63A TP MCCB as incommer.
Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 A Single pole
16 A Single pole
32 A Double pole for SPN UPS DB
63A, 36 KA, 4P Thermal Magnetic Protection MCCB for incomminng feeder Make ; Havells, Panasonic, Schineider as approved.
Supplying and fixing of following ways surface/ recess mounting, 240 V, SPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCB/ RCCB and incomer) as required.8 way Double door
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply & Installation of Light/ Luminaries and Fixtures
Installation, testing and commissioning of prewired, flourescent fittings / all type of LED indoor ceiling fittings, complete with all accessories and tube etc. directly on ceiling/ wall/ False ceiling, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core cable etc. as required.
Supplying, installing, testing and commissioning of 20W pre-wired LED lighting fixture complete with LED lamps etc. as required complete. LED BATTEN-TUBES with High quality aluminium extruded with decorative end caps. [TL] of approved make
Supplying of following LED lighting fixtures complete with Drive and Lamps with reflector/cover etc. complete as required:- Make : Syska/ CGL/ Havells/ Surya or Panasonic as approved Intergral square shaped recess rhombus slim with of the tile makes seamlessly blend in with the ceiling space with geomatric and aligned design , the tile can be arranged in symmetric and abstract way to nmake the ceiling a peice of art for MEETING lighting room. Make CGL LCTLRF6-36 WW or equivalent SYSKA / HAVELLS / SURYA / Panasonic as approved.
Supplying with fiitings and fixing of Pre wired LED lightining fixtures complete with LED strip light having 25-36W, and minimum 3000 lm, 4000K, 1122 mm long and 75 mm wide recess linear light. Make:- PHILLIPS/ HAVELLS/ SYSKA or equivalent
TV WIRING
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required for service call indicating wires and TV co-axial cable inside only. Make : Anchor / Richa or equivalent as approved. 20mm conduit for TV co-axial cable
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of Co- axial TV outlet on wall/ partition including flush MS Box, front plate and jack complete as required. TV antenna socket outlet
Supplying and fixing of Splitter box in suitable size of G.I. Enclousure with cover plate including connections and making good the damage etc. as required. 2 way
Supply, Installation, Testing and commissioning of UPS
Supply, Installation, Testing and commissioning of on line transformer base 5 KVA UPS with external 16 nos. SMF - VRLA battery module/ bank having 12 months warranty. Make: Microtek or equivalent as approve.
Earthing & Lightening Arrestors
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.For Panel & Lightning Arrester Earthing
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia cover plate having locking arangement and watereing pipe with charcoal / coke andsalt as required for MDB panel eartihing.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing earth bus bar joint made of 20mmx3mm thick 125 mm long with 6 nos. G.I bolts , nuts, chuck nut and spring washers etc. complete as requried
Supply, Fitting Fixing of Shock Treatment Chart
Supply and Laying of CAT6 Cable. (Make:- Molex/ Digisol/ DLink)
Supply and Laying of 25MM PVC Conduits (Make:- AKG/ Berlia)
VRF SYSTEM
Supply, installation, testing and commissioning of 415V, 3Ph-50HZ aircooled type side discharge VRF system unit, compresing of type inverter technology based hermetically sealed scroll compressor (Full inverter) with R410a Refrigerant, aircooled condenser along withinbuilt microprocessor panel including copper pipe, upvc drain pipe and other accessories with following minimum components- 12 HP side discharge out door unit Supply of indoor unit (4-way CAS units-2.0 TR) Supply of impored indoor REFNET joints Cordless controller Ancillary items: Inverter scroll VRF units, with outdoor installation pressure testing nitrogen fusing ect. REF (R-410) VRF V I Pads- VRF Installation of VRF indoor units Installation of imported REFNET joint
WALL PANELLING
Supplying materials and making interior wall paneling (Type-1) as per the approved design and specification. The specifications of materials and construction methodology will be as follows:- Making frame for partition with 19mm thick ply box section of size 75x75 mm as per the approved drawing. 19 mm thick plyboard to be fitted on one side of the frame and then 12 mm plywood to be fixed above it with laminate finish of 1mm thickness of approved colour and shade & as per approved design. A slot of 900X390mm to be cut out from the 19 mm ply and openable door shutter of same material to be fixed. Two cut outs of 600X1200 to be kept for fixing of fabric covered wool panel (acoustical material). Refer drawing for corresponding measurements . Fabric Covered wood wool panel mounted on supplied G I Frame work consisting of basic profile, main profile & edge profile.The woodwool panel will be back lined with 50mm thick 1; Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C . The frame work shall be back lined by using polyester wool having a density of 1000 GSM and 50mm thick. Including all other accessories like magnetic catcher, hinges, good quality adhesive, screws etc. to finish and complete as per directions of Engineer In-charge.
Supplying materials and making interior wall paneling (Type-2) as per the approved design and specification. The specifications of materials and construction methodology will be as follows:- 19 mm thick plyboard covered on one side with approved laminates of minimum 1.0mm thickness with the combination provided and fabric covered wood wool panel of size 1200 x 600 x 20mm are to be fitted on existing wall as per the design. Including all other accessories like good quality adhesive, screws etc. to finish and complete as per the Architectural drawings and directions of Engineer In-charge.
WPC PARTITION
Supplying and installation of WPC partition with frame as per the approved design and specification.Framing from section of 4"x1.5" members to be fitted both horizontally and vertically at a distance of 1200mm-1800mm. WPC wall panel of size 125mmx20mm and length 2.4m to be placed vertically above the framing one after other walnut colour, with woden effect surface finish. The partition has 6 openings of size 750x2100mm.100mm WPC to be fitted to three sides of the opening. WPC squar panel to be installed at the bottom of the vertical members. All the panels will be fittedwith channels & clips.
PLY WOOD
Providing and fixing 19 thick ply wood board for panelling works as per approved design and drawing .
Providing and fixing 12mm thick ply wood board for panelling works as per approved design and drawing.
LAMINATE
Providing and fixing 1.2mm to 2mm thick laminate of approved colour and shade in all visible plyboard surfaces including inner surface of vertical and horizontal coves and band. Make- Greenlam/ Merino/ Virgo or equivalent as approved.
UTILITY TABLE
Supplying materials and making side table with drawers on site as per the approved drawing and specifications. The specifications of materials and construction methodology will be as follows: Making table with 19 mm thick ply board finished with laminate as specified. The material should be flame retardant as per BS-476/97 and EN438-6 with classification of BS1D0 standard property. Finished and complete as per the specifications, drawings and instruction of the Engineer-in-charge.
MAIN CONFERENCE TABLE
Supplying materials and making table on site or at factory as per the approved drawing and specifications. The specifications of materials and construction methodology will be as follows: Top: Making table top with 19 mm thick Ply board covered with MDF board of 7.5 mm thickness. The border of the top should be double layered to get 32 mm thick as per the approved drawing and design. The material should be flame retardant as per BS-476/97 and EN438-6 with classification of BS1D0 standard property. Necessary arrangement should be made to assemble/ de-assemble the top. Special care should be taken to get smooth and elegant look and there should not be any sharp corner. Colour and edge lining will be as per the view and instruction of the Engineer-in-charge. (The measurements will be taken on finished size of the top.) The top and edge of the table should be finished with White Duco Paint. The sides should be covered with approved laminates of minimum 1.0mm thickness with the combination shown in the 3D view. All necessary arrangements for Pop-up box, Cable manager, maintenance door in the supporting box, etc. should be made for wasy operation. Finished and complete as per the specifications, drawings and instruction of the Engineer-in-charge.
SIDE CONFERENCE TABLE
Supplying materials and making side conference table (Table-1) on site or at factory as per the approved drawing and specifications. The specifications of materials and construction methodology will be as follows: Top: Making table top with 19 mm thick Ply board covered with MDF board of 8 mm thickness. The border of the top should be double layered to get 32 mm thick as per the approved drawing and design. The material should be flame retardant as per BS-476/97 and EN438-6 with classification of BS1D0 standard property. Necessary arrangement should be made to assemble/ de-assemble the top. Special care should be taken to get smooth and elegant look and there should not be any sharp corner. Colour and edge lining will be as per the view and instruction of the Engineer-in-charge. (The measurements will be taken on finished size of the top.) The top and edge of the table should be finished with White Duco Paint. The sides should be covered with approved laminates of minimum 1.0mm thickness with the combination shown in the 3D view. Size: 3030x600
Supplying materials and making side conference table (Type-2) on site or at factory as per the approved drawing and specifications. The specifications of materials and construction methodology will be as follows: Top: Making table top with 19 mm thick Ply board covered with MDF board of 8 mm thickness. The border of the top should be double layered to get 32 mm thick as per the approved drawing and design. The material should be flame retardant as per BS-476/97 and EN438-6 with classification of BS1D0 standard property. Necessary arrangement should be made to assemble/ de-assemble the top. Special care should be taken to get smooth and elegant look and there should not be any sharp corner. Colour and edge lining will be as per the view and instruction of the Engineer-in-charge. (The measurements will be taken on finished size of the top.) The top and edge of the table should be finished with White Duco Paint. The sides should be covered with approved laminates of minimum 1.0mm thickness with the combination shown in the 3D view. Size: 2250x600
MAIN CHAIR
Providing and supplying high back chair with ergonomic design. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam 50mm thick having density 40kg/m³ with fabric tapestry and the back shall be made of two piece injection moulded polypropylene net cover upholstered with breathable mesh tapestry. The base of the seat shall be supplied with PP cover and the backrest shall be made by keeping the natural curvature of the spine and cushion base adjustable lumbar support which helps to provide full back support as well as head support. The chair shall be supplied with black integral 3D adjustable polyurethane arm having sliding, up-down, to & fro motion. The chair shall be supplied with 2D adjustable headrest for head support. For seating durability the chair shall have synchro tilt 360 degree revolving mechanism with upright position locking and tilt tension adjustment. The pneumatic seat height adjustment for healthy seating, user can adjust seat height up to 100mm with BIFMA standard class-3 gas-lift to suit them using the lever under the seat. The gas-lift mechanism should be tested as per ANSI/BIFMA X5.1-2011 standards. The pedestal should have five legged injection moulded in 30% glass filled nylon having pitch circle dia. 660 mm fitted with 5 nos. twin wheel castors. The castors of the chair should be injection moulded in black 30% glass filled nylon, confirming to ANSI/BIFMA standards X5.1-2011 tested 98,000 cycles with 250lbs load. The seat size shall be 500±10 mm(D) X 500±10 mm(W) and back size shall be 450±10 mm(W) X 760±10 mm(H) from seat. Overall height shall be = 1190±10 mm, base width/ depth = 760±10 mm. The OEM should have all the necessary quality certifications like ISO 9001, ISO 14001, ISO 45001, ISO 50001, AIOTA, BIFMA membership certificate, Greenpro and Greenguard certification from UL USA for some of its products.
SIDE CHAIR
Providing and supplying a medium back chair with ergonomic design, comfortable & aesthetically appealing. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam 50mm thick having density 40kg/m³ with fabric tapestry and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made by keeping the natural curvature of the spine and cushion base adjustable lumbar support which helps to provide full back support. The chair shall be supplied with black integral adjustable polyurethane arm. For seating durability the chair shall have synchro tilt 360 degree revolving mechanism with upright position locking and tilt tension adjustment. The pneumatic seat height adjustment for healthy seating, user can adjust seat height up to 100mm with BIFMA standard class-3 gas-lift to suit them using the lever under the seat. The gas-lift mechanism should be tested as per ANSI/BIFMA X5.1-2011 standards. The Pedestal should have five legged injection moulded in 30% glass filled nylon having pitch circle dia. 660 mm fitted with 5 nos. twin wheel castors. The castors of the chair should be injection moulded in black 30% glass filled nylon, confirming to ANSI/BIFMA standards X5.1-2011 tested 98,000 cycles with 250lbs load. The seat size shall be 500±10 mm(D) X 500±10 mm(W) and back size shall be 450±10 mm(W) X 530±10 mm(H) from seat. Overall height shall be = 960±10 mm & overall width/depth = 760±10 mm. The OEM should have all the necessary quality certifications like ISO 9001, ISO 14001, ISO 45001, ISO 50001, AIOTA, BIFMA membership certificate, Greenpro and Greenguard certification from UL USA for some of its products.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .