Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Qualified AIRPORT ROAD SKALZANGLING LEH AIRPORT ROAD LEH LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | Qualified MSE, MII, Category: General |
| 2 | Qualified | Qualified MSE, MII, Category: General |
| 3 | Qualified | Qualified MSE, MII, Category: ST |
| 4 | Disqualified 212 FORT 16 22 BAKE HOUSE FORT MCC LANE 2ND FLOOR VILLAGE TOWN MUMBAI CITY MUMBAI MUMBAI MAHARASHTRA 400023 INDIA | 400023 | Disqualified MSE, MII, Category: General |
| 5 | Disqualified 1 NEAR JEEVANDEEP ASHRAM ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | Disqualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Oct 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SERVICING OF CENTRAL HEATING PLANT OF 5TH BN LEH
5456806
GEM/2023/B/4081810
Two Packet Bid
Servicing Repairing of blockage choke in the hot water oil fired boiler of capapcity 350000 kcal pe
15 days
Ladakh; Leh Ladakh
Total value wise evaluation
BOQ
5 documents required · 5 mandatory
2 yrs
₹3
20%
Exempted
23 Oct 2023
13 Oct 2023
23 Oct 2023
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Servicing Repairing of blockage choke in the hot water oil fired boiler of capapcity 350000 kcal per hr | Servicing/ Repairing of blockage/choke in the hot water oil fired boiler of capapcity 3,50,000 kcal/hr including repair of control panel, control accessoriees equipments, replacement of fuel filters, boiler packing seal, cleaning of fire tube, water shell, opening/closing of boiler body wherever required as per directions of Engineer in Charge. | 3 | JOB | buyer1@123 | 15 |
| 2 | Rewinding of 15 HP Motor glycol circulating Motor with one year warranty of rewinding including removing carriage and refixing charges of motor | Rewinding of 15 HP Motor glycol circulating Motor with one year warranty of rewinding including removing/carriage and re-fixing charges of motor | 3 | EACH | buyer1@123 | 15 |
| 3 | Servicing Repairing of fan coil unit in adm block and 128 men barrack ic Rebinding cleaning blockage in coils inter connecting ducting and electrical repair as per directions of engineer in charge. | Servicing/Repairing of fan coil unit in adm block and 128 men barrack i/c Re-binding, cleaning blockage in coils, inter connecting ducting and electrical repair as per directions of engineer in charge. | 10 | RMTR | buyer1@123 | 15 |
| 4 | Running and comprehensive repairing and making good of leakage in the liquid circulation pipe of size 25mm to 50 mm dia with required type of welding including gas welding. | Running and comprehensive repairing and making good of leakage in the liquid circulation pipe of size 25mm -50 mm dia with required type of welding including gas welding. This includes all the cost required to maintain leak proof liquid supply. In the Pipe network during the entire season upto ie. 31st March 2023 as per approved specification and directions of engineer in charge. | 85 | NOS | buyer1@123 | 15 |
| 5 | Replacement of Floor wall mounted steel panel radiator of capacity 4800 Kcal per Hr anodied powder coating casing with grills including making connection | Replacement of Floor/wall mounted steel panel radiator of capacity 4800 Kcal/Hr anodied powder coating casing with grills including making connection with the existing water supply network and electric connection complete. The Model shall be compatible with the existing system and specifications. | 26 | LTR | buyer1@123 | 15 |
| 6 | Supply and filling or top up the glycol unit existing central heating system.as per approved specification and direction of engineer in charge. | Supply and filling or top up the glycol unit existing central heating system.as per approved specification and direction of engineer in charge. | 1,100 | NOS | buyer1@123 | 15 |
| 7 | Providing and replacement of existing fuel pipes as per approved specification and direction of engineer in charge. | Providing and replacement of existing fuel pipes as per approved specification and direction of engineer in charge. | 6 | NOS | buyer1@123 | 15 |
| 8 | Providing and replacement of fuel filters as per approved specification and direction of engineer in charge. | Providing and replacement of fuel filters as per approved specification and direction of engineer in charge. | 3 | NOS | buyer1@123 | 15 |
| 9 | Providing and replacement of burner nozzles as per approved specification and direction of engineer in charge | Providing and replacement of burner nozzles as per approved specification and direction of engineer in charge | 6 | JOB | buyer1@123 | 15 |
| 10 | Providing and replacement of ignition rod as per approved specification and direction of engineer in charge | Providing and replacement of ignition rod as per approved specification and direction of engineer in charge | 6 | NOS | buyer1@123 | 15 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_5456806.pdf
GEM_BID
new_doc_10-12-2023_19-51_2023-10-12-19-59-57_e19d9b2ad5d2b447937c43777d9d408f.pdf
BOQ
boq_item_sample_file_2023-10-12-19-59-57_4a31ad88b5a437ecffdd9cae9f85a10e.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .