| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹49.7 L+₹9.0 L (22.0%)Rejected-Finance 110 5 BONOMALI NASKAR ROAD BEHALA PARNASHREE PARNASHREE KOLKATA WEST BENGAL 700060 | KOLKATA | WEST BENGAL | 700060 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹49.8 L+₹9.1 L (22.4%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹49.9 L+₹9.2 L (22.5%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹49.9 L+₹9.2 L (22.6%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
Garrison Engineer Alipore. Military GARRISON ENGINEER MILITARY Engineer Services, ALIPORE, NO 1 NATIONAL LIBRARY AVENUE ROAD, KOKATA - 700027
8047/B/E8
2022_MES_512388_1
GE/ALP (8047B) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
330 days
GE ALIPORE KOLKATA
CLASS D and CATEGORY c(i) and d (v)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹98,000
Yes
24 May 2022
8 Mar 2022
29 Mar 2022
8 Mar 2022
28 Mar 2022
21 Mar 2022
60 days
Amount
Outsourcing services for day today/ routine/ periodical Comprehensive maintenance for providing services for smooth functioning including general maintenance of complete central AC plant 3 x 225 TR with all accessories and sub assemblies (including Sunday and Holidays) for the following plants and eqipments: - (a) Basement Central AC Plant (i) Screw type Chiller unit 3 x 225 TR alongwith compressor, evaporator, condensor including allied equipments and sub-assemblies (02 working + 01 standby) (ii) LT control panel with accessories (iii) 3 x Condensor Water Pump (02 working + 01 standby) (iv) 3 x Chiller Water Pump (02 working + 01 standby) (v) 3 x Cooling tower (02 working + 01 standby) alongwith operating valves and pipe line (vi) Cooling tower water tanks 15000 ltrs x 06 Nos (vii) Chilled Water pipe line throughout CH (EC) Main Hospital Building (G+7) and TC(EC) building (G+1) and Make up Water tanks at roof top (b) CH (EC) Main Hospital Building (G+7) and TC(EC) building (G+1) (i) 9 x Air Handlig Units (ii) Air Duct opening grills (iii) 43 x Fan Coil Units
NOTES :- 1. Maintenance of AC plant and entire system/equipmentsof capacity 3x 225 TR shall be carried out in summer, winter and monsoon season as per the period of contract including daily/periodical checks i.e quarterly maintenance requirement as per manufacturer's instructions. The above quoted rates covers daily upkeep of AC plant as described above all as specified and directed by the Engineer-in-Charge for smooth & efficient performance to achieve inside designed conditions throughout the season. 2. Cleaning of inside and out side of the installation and the cost thereof shall be deemed to be included in the unit rate quoted against this item. 3. Contractor shall rectify the fault within 4 hrs or as directed by Enng-in-Charge. 4. Contractor shall maintain temperature of AC plants as per direction of Enng-in-Charge or his rep within design limit as specified in PS. 5. During entire contract period contractor shall replace any minor defective components or any other minor materials which is not specified in sch 'A' but require for repair/replace to make plant/ mechinery fully functional shall be provided by Contractor at his own cost. The cost of the same is deemed to be included in the quoted unit rate. The decision of GE regarding minor components/materails shall be final and binding.
6. The cost of transportation and other necessary equipment shall be arranged/brought by the contractor in this effect , hence the bidder/tenderer is advised to visit the site and assess the quantum of the work to be carried out in the contract and quoting of rate shall be accordingly 7. Make and model of part to be replaced shall be same as existing at site or as per OEM. Replacement of spare parts shall be measured and paid as "supply only" of respective item of Sch 'A'. Fixing of spare parts shall be included in the above item. 8. Comprehensive /Periodic maintenance means ensuring optimal functioning of AC plant by the synchronizing levels at no extra cost. 9.The contractor shall provide skilled mechanic for comprehensive maintenance of the plant. However, Contractor shall provide high skilled mechanic/Special engineer required for fault during currency of contract period if required. The cost of the same shall be deem to be included above quoted unit rate. 10. All minor labour charges for taking out old spares/ items and replacing spares, testing, commissioning transportation etc shall be deemed to be included in the above quoted rates.
In case any expert technician/engineer required for major faults of pant shall be provide by contractor without any extra cost of depertment. 11. Above central AC installation shall be run 24 Hr x 7 days. 12. Consumable/lubricants etc shall be included in the quoted unit rates.
Supply only following spares for chilled water pumps 40HP - 03 Nos. Make - Kirloskar, Model No - UP 100/38 :-
(a) Bearing Housing Driving End, make: Kirloskar
(b) Bearing Housing Driven End,make: Kirloskar
(c) Bearing No 6309, Make - TATA/ SKF/ NBC
(d) Impeller
(e) Shaft
(f) Shaft sleeve
(g) Oil seal
(h) Set of 'O' Rings
(j) Tyre coupling cover for Pump-Motor coupling
(k) Pump motor coupling with MS key
Supply only following spares for Condenser pump set 30HP 03 Nos, Make : Kirloskar, Model No. UP 125/30A : -
(a) Bearing Housing Driving End
(b) Bearing Housing Driven End
(c) Bearing No 6306, Make - Tata/ SKF/ NBC
(d) Impeller
(e) Shaft
(f) Shaft sleeve
(g) Oil seal
(h) Set of 'O' Rings
(j) Tyre coupling cover for Pump-Motor coupling
(k) Pump motor coupling with MS key
Supply only Refrigerent Gas R-22 in returnable container for chiller unit of 225 TR, Make :Mafron, Floron or equivalent
Supply only following spares for Chiller unit 225 TR, Make : Trane
(a) Solenoid valve coil oil line, Make - Trane / Parkar
(b) Solenoid valve coil Loader/ Unloader line, Make - Trane / Parkar
(c) Compressor oil filter
(d) Refrigerant Filter
(e) Compressor oil
(f) HP Switch, Make : Danfos / Indfos / ALCO
(g) LP Switch, Make : Danfos / Indfos / ALCO
(h) Condensor Refrigerant sensor
(j) Discharge line temperature sensor
(k) Evaporator leaving/ entering water pair sensor
(l) Condensor leaving/ entering water pair sensor
Supply only following spares for Fan coil unit 1/1.5 TR capacity - 43 Nos : -
(a) Thermostat model No T 6373, Make : Honey Well for FCU
(b) Long shaft with accessories for FCU Blower Motor
(d) Blower motor winding 1/10HP
Miscellaneous items for AHUs - 09 Nos of sizes (12.5 TR TO 160 TR): -
(a) Material and labour for fabrication work and installation of AHU cabinet of height upto 1.60 mtr as per existing size with 16 SWG GI sheet including MS channels of required size and length as per existing with legs as per site requirement and arrangement for mounting of AHU motor with adjustable base frame, and making opening for chilled air duct outlet including dismantling of old AHU cabinet all as specified and as directed by the Engr-in-Charge. [Note: - For payment purpose, the top portion of the AHU cabinet will be measured only]
(b) Material and labour for insulation of inner surface of AHU cabinet with acoustic insulation comprising of layers of 12 mm thick acoustic rigid fibre glass sheet covered with onionskin paper fastened with 26 SWG aluminium perforated sheet fixed with bolts and nuts including taking out of old insulation all as specified and as directed.
(d) M & L for Fine filter of size .620 x 508 x 45 mm for AHU cooling coil
(e) M & L for Fine filter of size 600 x 500 x 40 mm for AHU cooling coil
(f) M & L for Ball Bearing No 6306, Make SKF for motor capacity 5 HP
(g) M & L for Ball Bearing No 6308, Make SKF for motor capacity 7.5 HP
(h) M & L for Bearing for blower (Pilo Block bearing Model No UC207, Make - FYH /NTN
(j) M & L for Bearing for blower (Pilo Block bearing Model No UC206, Make - FYH /NTN
(k) M & L for V belt of size B-94
(l) M & L for V belt of size B-93
(m) M & L for V belt of size B-92
(n) M & L for V belt of size B-90
(o) M & L for V belt of size B-89
Supply only following spares for Cooling Tower, Make - Paharpur:-
(a) Spiral target nozzel
(b) Fill pack sheet
(c) Servo system gear oil
(d) Support structure for Cooling Tower motor for Cooling Tower Model No: 21104 (T&B) of make Paharpur Cooling Towers Ltd
(e) Ball brass valve high pressure, with polythene float and flynut complete screwed for iron pipe 25 mm
Supply only following spares for LT Panel: -
(a) 3 pole power contractor AC3 rating 40 Amp, make: L&T, type ML 3 of or equivalent
(b) 3 pole power contractor AC3 rating 32 Amp, make: L&T, type ML 2 of or equivalent
(c) 3 pole power contractor AC3 rating 25 Amp, make: L&T, type ML1.5 of or equivalent
(d) Thermal overload relay direct mounting 14 to 23 Amp, make: L&T, Cat No SS94135OODO or equivalent
(e) Thermal overload relay direct mounting 20 to 33 Amp, make: L&T, Cat No SS94136OOEO or equivalent
(f) Thermal overload relay direct mounting 30 to 50 Amp, make: L&T, Cat No SS94136OOGO or equivalent
(g) Analog Timer 415V, 50 Hz 3-30 seconds, make: L&T, type ET 100/ ST 100 or equivalent
Descaling and cleaning of condensors by using Kirloskar recommended cleaning solution followed by mechanical cleaning of condensor tubes including replacement of nut bolts and gasket etc in every 6 months or as and when ordered by Engineer-in- Charge.
Descaling and cleaning of evaporators by using Kirloskar recommended cleaning solution followed by mechanical cleaning of evaporator tubes including replacement of nut bolts, suitable insulation and gasket etc in every 6 month or as and when ordered by Engineer-in- Charge.
Descaling and cleaning of AHU coils from outside and cooling tubes from inside by flowing suitable chemical in the tubes for removing all foreign material deposited in the coil and tubes in every 3 months or as and when ordered by Engineer-in-Charge. [Note: Rates quoted by contractor for item No 10 to 12 deemed to be inclusive of necessary arrangement viz. necessary water jet pumps, coil cleaning chemicals, tools etc]
Material and Labour for cleaning of HVAC duct thoroughly including taking necessary photographs before and after cleaning all as specified and as directed by the Engr-in-Charge
Dismantling of existing MS pipes with insulation by carefully dismantling from chilled water pipe line with gas cutting where necessary and Supply and laying MS Pipes 'medium' grade as per IS: 1239 (Part-I) of make: TATA/ SAIL/ JINDAL with electric welding where necessary and laid in floors or fixed to walls and ceilings etc all as specified and as directed of the following sizes: - [Note: - Pipe fittings all type will be measured and paid under separate item]
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Material and Labour for MS Flange with rubber gasket including electric welding with MS pipes suitable for fixing with the following sizes of MS pipes: - [Note: - Bolts, nuts and washers will be measured and paid under separate item]
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut all as specified and as directed.
Material and Labour for fittings for MS Pipes such as Bends, Tapers, "Y" junction, double branch, cross, Tee pieces (single & double branch), any type and angle/ radius and straight connecting pieces all as specified and as directed.
Material and Labour for insulation of MS Pipe with PUF slab (Density 36 kg/ cm2) upto 50 mm thick and not less than 40 mm thick with and including applying bituminous compound and cladding with sheet metal cladding with aluminium not less than 22 gauge thick complete suitable for insulating the following sizes of MS pipe: -
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Material and labour for dismantling of old butterfly valves and fixing of new Butterfly valve of make: C&R/ Kartar/ Pelicon or equivalent in other approved make all as specified and as directed suitable for the following sizes of pipe: - [Note: - Bolts, nuts and washers will be measured and paid under separate item]
40/ 50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Outsourcing services for day today/ routine/ periodical Comprehensive maintenance of complete central AC plant 3 x 200 TR for providing services for smooth functioning of plants including chillers, pumps, motors cooling towers, AHUs, Cooling tower pipe line, chilled water pipeline, air duct, valves, LT panel and its accessories complete, maintanance and repair as and when required to run the plant with full efficiency without break down including saturday, sunday and holidays and mechanic with adequate experience should be available to rectify in case any fault observed and all as specified and directed by Engineer-in-Charge for the following plants & equipments :-
(a) Defi Tech AC Plant (i) Screw type Chiller unit 3 x 200 TR alongwith compressor, evaporator, condensor including allied equipments and sub-assemblies (02 working + 01 standby) (ii) LT control panel with accessories (iii) 3 x Condensor Water Pump (02 working + 01 standby) (iv) 3 x Chiller Water Pump (02 working + 01 standby) (v) 3 x Cooling tower (02 working + 01 standby) alongwith operating valves and pipe line (vi) Cooling tower water tanks (vii) Chilled Water pipe line throughout CH (EC) Main Hospital Building (G+5) (b) CH (EC) Defi Tech building (i) 15 x Air Handlig Units (ii) Air Duct opening grills (iii) 15 Treated frush air unit
NOTES :- 1. Maintenance of AC plant and entire system/equipmentsof capacity 3x 200 TR shall be carried out in summer, winter and monsoon season as per the period of contract including daily/periodical checks i.e quarterly maintenance requirement as per Engineer in charge instructions. The above quoted rates covers daily upkeep of AC plant as described above all as specified and directed by the Engineer-in-Charge for smooth & efficient performance to achieve inside designed conditions throughout the season. 2. Cleaning of inside and out side of the installation and the cost thereof shall be deemed to be included in the unit rate quoted against this item. 3. Contractor shall rectify the fault within 24 hrs or as directed by Enng-in-Charge. 4. Contractor shall maintain temperature of AC plants as per direction of Enng-in-Charge or his rep within design limit as specified in PS. 5. During entire contract period any minor defective components which is not specified in sch 'A' but required for repair/replace to make plant/ mechinery fully functional shall be provided by Contractor at his own cost. The cost of the same is deemed to be included in the quoted unit rates and no extra cost shall be paid to the contractor in this effect. The decision of GE Regarding minor components/meterials shall be final and binding.
6. The cost of transportation and other necessary minr equipment shall be arranged/brought by the contractor in this effect , hence the bidder/tenderer is advised to visit the site and assess the quantum of the work to be carried out in the contract and quoting of rate shall be accordingly 7. Make and model of part to be replaced shall be same as existing at site or as per OEM/ Engineer n cahrge. Replacement of spare parts shall be measured and paid as "supply only" of respective item of Sch 'A'. Fixing of spare parts shall be included in the above item. 8. Comprehensive /Periodic maintenance means ensuring optimal functioning of AC plant by the synchronizing levels at no extra cost. 9.The contractor shall provide skilled mechanic for comprehensive maintenance of the plant. However, Contractor shall provide high skilled mechanic/Special engineer required for fault during currency of contract period if required. The cost of the same shall be deem to be included above quoted unit rate. 10. All minor labour charges for taking out old spares/ items and replacing spares, testing, commissioning transportation etc shall be deemed to be included in the above quoted rates.
In case any expert technician/engineer required for major faults of pant shall be provide by contractor without any extra cost of depertment. 11. Above central AC installation shall be run 24 Hr x 7 days. 12. Consumable/lubricants etc shall be included in the quoted unit rates.
Supply only following spares for AC plant of 3 x 200 TR. Make - Kirloskar
Re- winding of moter of capacoty 7.5 HP
Re- winding of moter of capacoty 10 HP
Re- winding of moter of capacoty 12.5 HP
Re winding of moter of capacoty 20 HP
Re- winding of moter of capacoty 25 HP
Supply only cooling tower fills block
Supply only 20HP VFD for secondary pump
Supply only PCB Board with display ( For AHU )
Supply only V-Belt with following size- A-69,A-56,A-56,A-50,A-42,A59,A-39,A-60,A-79 .
Supply only Contractor 3TF47
Supply only Contractor 3TF51
Supply only DO (Drier Core)
Supply only MCCB , 100 Amp ,4 Pole
Supply only MCCB 63 Amp 4 Pole
Supply only MCB 20 Amp, 3 Ph
Supply only GI duct 24WG , Tata /JINDAL
Supply only nitrile ruber 13mm
Dismantling of existing MS pipes carefully dismantling from chilled water pipe line with gas cutting where necessary and Supply and laying MS Pipes 'medium' grade as per IS: 1239 (Part-I) of make: TATA/ SAIL/ JINDAL with electric welding where necessary and laid in floors or fixed to walls and ceilings etc all as specified and as directed of the following sizes: -
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Material and Labour for MS Flange with rubber gasket including electric welding with MS pipes suitable for fixing with the following sizes of MS pipes: -
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only cyphon with bib cock guage
Supply only thermometer
Supply only Electronic Expention valve E6U
Material and labour for dismantling of old butterfly valves and fixing of new Butterfly valve of make: C&R/ Kartar/ Pelicon or equivalent in other approved make all as specified and as directed suitable for the following sizes of pipe: -
40/ 50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only Gas ket Kit for CXH5 Compresser
Supply only Gas ket Kit for CXH5 Condensor
Supply only Spiral target valve
Supply only Spiral Eliminator block (fill block)
Supply only Float Valve
Supply only Header PVC line 6'
Supply only Header branch PVC line 2'
Supply only MCX 31 Contactor 82.5A
Supply only MN 5 over load 30to 50 A
Supply Only Ball bearing for screw chiller compress for 200 TR
Supply Only Compressor Oil
Supply Only Compressor Oil Filter
Supply Only Refigeration Filter
supply Only Operating Sensors for Screw compressor 200 TR
Supply only nitrogen for leak testing
Supply only refrigerant 134A
Descaling and cleaning of condensors and evaporators by using Kirloskar recommended cleaning solution followed by mechanical cleaning of condensor and evaporators tubes including replacement of nut bolts and gasket etc in every 6 months or as and when ordered by Engineer-in- Charge.
Descaling and cleaning of AHU coils from outside and cooling tubes from inside by flowing suitable chemical in the tubes for removing all foreign material deposited in the coil and tubes in every 3 months or as and when ordered by Engineer-in-Charge. [Note: Rates quoted by contractor for item No 31 to 32 deemed to be inclusive of necessary arrangement viz. necessary water jet pumps, coil cleaning chemicals, tools etc]
Material and labour for painting with one coat of red oxide primer and two coats of black japan paint including preparation old/ new surface of steel of any description all as specifierd and as directed.
Material and Labour for Repair and maintnance of 110TR Kirloskar unit Condencer from defi tech AC Plant after closing all valve and appliances de- canning refigrent to the sytem, disconnecting all connected electrical and pipe line connection opening nut and bolts from the base. Dismantling the condencer throughly cleaning all parts of UNSV unit and replace copper tubes as required as per existing size Descaling after Leakage testing of condencer unit and the gas filling,cheking and reassembling all the same fixing in position commissioning and testing complete. Note : Refrigerant as required extra to be measure and pai under respective item.
Material and Labour for Repair and maintnance of 220 TR Kirloskar unit Chiller from defi tech AC Plant after closing all valve and appliances de- canning refigrent to the sytem, electrical and pipe line disconnecting all connected electric connection opening nut and bolts from the base. Dismantling the Chiller or throughtly cleaning all parts of UNSV unit and replace copper tube as required as per existing size. Descaling Leakage testing of chiller unit and the gas filling,cheking and reassembling all the same fixing in position commissioning and testing complete. Note : Refrigerant as required extra to be measure and pai under respective item.
S B ENTERPRISE
RADHA ENTERPRISE
M/S J S ENTERPRISES
KWALITY CONSTRUCTION
EASTERN REFRIGERATION AND ELECTRICAL CO
INDIA ELECTRICAL EQUIPMENTS
Tirupati Buildcon Pvt. Ltd.
JAIN CONSTRUCTION AND ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .