Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.6 LAccepted-AOC RHP IB COMPLEX LODHOMA DARJEELING 734201 | DARJEELING | DARJEELING | WEST BENGAL | 734201 | ₹60.6 L | L1 | Accepted-AOC Quoted lowest rate. |
| 2 | L2₹61.2 LRejected-Finance KANKEBONG BUSTY P O P S LODHAMA LODHAMA DARJEELING 734201 | LODHAMA | DARJEELING | WEST BENGAL | 734201 | ₹61.2 L | L2 | Rejected-Finance Did not quote Lowest Rate. |
| 3 | L3₹62.4 LRejected-Finance FATINGTAR LODHOMA DARJEELING 734201 | DARJEELING | DARJEELING | WEST BENGAL | 734201 | ₹62.4 L | L3 | Rejected-Finance Did not quote Lowest Rate. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Did not submitted required documents. |
| 5 | Rejected-Technical | - | - | Rejected-Technical Did not submitted required documents. |
Tender Value
₹55.7 L
EMD Value
₹1.1 L
Closing Date
9 Feb 2026, 11:00 amClosed
The Project Manager, RHP, St-II
Administrative Building, Dovan, Lodhoma, Darjeeling, 734201
Construction of a protection wall along with a chute drain near Inspection Bungalow under Rammam Hydel Project, St-II.
2026_WBSED_990276_1
PM/RMM/e-Tender/CIVIL/25-26/18 Dated.17.01.2026
Open Tender
CIVIL WORKS
90 days
Rammam Hydel Project, St-II
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹1.1 L
4 Jun 2026
27 Jan 2026
11 Feb 2026
27 Jan 2026
9 Feb 2026
27 Jan 2026
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, removing, spreading or stacking of spoils within a lead of 150m as directed and including trimming the sides of the trenches, leveling, dressing and ramming the bottom, and backfilling with approved material complete as per direction of the Engineer-in-Charge. V. In Hard rock ( blasting prohibited ) (iii) Without pumping out water
Labour for laying 150 mm to 200 mm boulder soling including rough dressing, hand packing and ramming down small pieces in the interstics excluding rolling and preparing the bed to proper level and filling up all joints with sandy clay or earth.
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor - Pakur variety - 1:3:6 proportion. (III) Cement concrete with 32 mm down graded gravel excluding shuttering
Ordinary Cement concrete (mix 1:2:4 ) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (b) River bazree
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (b) River bazree
Plum concrete work with 40 % cement concrete with 30 mm down graded stone metal and 60 % stone boulder of size 150 mm and above, placed in position as directed excluding shuttering if any. ii) (1:3:6) proportion
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(i) Tor steel/Mild Steel (iii) Other Manufactures not specified
Providing and laying of Filter media with granular materials/stone crushed aggregates/brick aggregates /river bed materials satisfying the requirements laid down in clause 2504.2.2 of MoRT&H Specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.(0.72 m3 of grit and 0.48 m3 of coarse sand)
Providing weep holes in Brick masonry / Plain /Reinforced concrete abutment,wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.
Providing Steel anchor dowels at the base of the well including drilling holes upto 1 m. depth in rock, placing the dowels in position and effectively grouting the holes (25 mm. diameter steel rod of 1 m length grouted upto 1 m. depth) etc. Complete as directed by Engineer in charge.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface].(II) With 1:4 cement mortar. (b) 15 mm thick plaster. i) In superstructure, ground floor
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per 100 sq.m.
Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, cross- drain etc. The rate is innclusive of fitting, fixing and striking out after completion of work as per specification and direction.
All items covering PWD, SOR, West Bengal (Based on P.W. D ., S.O.R ( Bldg w.e.f 01.11.2017 (15th corrigenda 07.09.2022) & Roads & Bridges w.e.f 30.08.2018 (12th corrigenda 29.07.2025)
Add BOCW cess @1% on the rate of all above items
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.91 MB
BOQ_2420486.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid