Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted | |
| 2 | L2₹3.7 L+₹37,455 (11.2%)Rejected-AOC | L2 | Rejected-AOC Quoted value is not the lowest |
Tender Value
₹4.1 L
EMD Value
₹8,218
Closing Date
14 Nov 2022, 2:30 pmClosed
The Director, CSIR-CLRI
CSIR-CLRI, Adyar, Chennai-600020
Provision for replacement of Incomer Cable and Metering Panel for Type-II (Bombay Type) Block-I and Type-III (New) Block-I in CSIR-CLRI Staff Quarters, Adyar, Chennai-600020
2022_CSIR_134220_1
CLRI/29(1)/2022-23/Wks
Open Tender
Electrical Works
Item Rate
30 days
CSIR-CLRI, Adyar, Chennai-600020
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹8,218
Yes
10 Jan 2023
7 Nov 2022
15 Nov 2022
7 Nov 2022
14 Nov 2022
7 Nov 2022
Amount
Electrical Part
DWC HDPE PIPE LAYING: Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (750 mm below ground level) including excavation and refilling the trench,etc.,complete as required. Make: Gemini/Rex/Duraline 63 mm dia (OD-63 mm & ID-51 mm nominal)
MV CABLE LAYING: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC/PVC pipe as required. Upto 35 sq. mm
CABLE END TERMINATION: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Make: LOTUS/COMET/DOWELLS 3.5 X 35 sq. mm
G.I. PIPE LAYING: Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (750 mm deep)and floor/road cutting and finishing the with PCC in original condition and wherever required based on site condition as directed and required by site Engineer etc. Make: Jindal/Tata 50 mm dia
EARTH CONDUCTOR: Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
MV Cable laying in wall:- Laying and fixing of one number PVC insulated and PCV shealted /XLPE power cable of 1.1 kV grade following size on wall surface/recesses as required. Upto 35sq mm (clamped with 1mm thick saddle)
CABLE ROUTE MARKER: Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing thesame in ground as required.
Potential Earth Electrode: Provision of copper Potential Earth Electrode type (Chemical earthing), 3mtrs, 1.5 inch dia with Augur / Drill / Bore a hole of 8 - 10 Inch in diameter to a suitable depth of 3 meters (Electrode Length). The work includes refilling the empty space around the Earthing Electrode with the 2 bags of moisture booster (compound /soil mix), each termination should be with suitable 2 set of Stainless Steel bolt, nut & flat & spring washers of each run, testing earth resistivity of the Electrode and provision of 2'x2'x1' brick & cement chamber with 2'x2' RCC cover including suitable painting etc. as required. Make: Value Engineers/ Galaxy Earthing Electrodes.
METERING PANEL: Supply, erection & commissioning of wall/floor mounting type of Energy Metering panel board fabricated with suitable size 14 SWG MS sheet/flat/angle duly painted and also suitable for Indoor installation and earthed consisting of the following as required: (a) Incomer: One chamber consisting of suitable size with mounting arrangements,supplying and fixing of 1no 125A TPN MCCB (Make: L&T/Legrand/Simens) (b) Out going : 9 No's 32A Double Pole MCB (Make: L&T/Legrand/Simens) The above MCCB/MCBs should be L&T/Legrand/Simens make and to be mounted in individual chambers consisting of suitable suitable size with mounting arrangements. (c) Suitable size epoxy insulated colour coded Copper bus bars chamber along with Aluminium earth bus for entire system. (d) Interconnection with suitable size insulated Copper link,spreder,provision of inscription labels etc. (e) Removing & refixing the exsisting EB Meters(9No's) and including outgoing wires end terminations with copper lugs.etc., (f) Suitable cable chamber with knock out holes, terminal blocks, interconnection materials etc.as required. (Work may be coordinated with TNEB if required)
SUPPLY OF 3.5 CORE, 35 SQ MM, ALUMINIUM UG CABLE: Supply of 3.5 core, 35sq mm, PVC insulated, Sheathed and armored aluminium 1100 V grade as per IS 1554 Standard UG cable, produce with necessary test certificate etc. as required. Make: Finolex/Polycab/Q-Flex
Buy Back Items
BUYBACK OF OLD METERING PANEL: Removal & buy back of existing Old metering panel consists of CRCA Structure,Cu Busbars&SFU unit etc.
POWERPOINT
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .