| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹37.9 L+₹4.1 L (12.0%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹38.5 L+₹4.6 L (13.5%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹39.8 L+₹5.9 L (17.5%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹45.4 L+₹11.6 L (34.1%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
2 Feb 2023, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
PROVISION OF IMPROVEMENT OF BASIC AMENITIES ALONG WITH BR AND EM MISCELLANEOUS WORK AT MD ACCN AT SITE P AND PROVISION OF ROOF TREATMENT IN VARIOUS TECH,ADMN BUILDINGS AND CERTAIN SANTIONED AND MINOR WORKS AT SITE P AFS UNDER GE(AF)THANE
2022_MES_566038_2
8239/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
THANE
AS PER NEW NIT UPLOADED ALONG WITH TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF THANE
₹94,000
Yes
2 May 2023
12 Jan 2023
3 Feb 2023
12 Jan 2023
2 Feb 2023
20 Jan 2023
12 Jan 2023 - 20 Jan 2023
Amount
Demolition of Stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc. ,complete all as specified and directed by Engr-In-Charge.
M&L for 12MM thick Particle board, medium density, flat pressed, single layer type or three layer type,BWR grade fixed with screws to timber frame work ,complete all as specified and directed by Engr-in-charge
M&L for 18/19MM thick Particle board, medium density, flat pressed, single layer type or three layer type,BWR grade fixed with screws to timber frame work ,complete all as specified and directed by Engr-in-charge
M&L for Plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads, sectional area Exc 13 Sq cm & n Exc 25 Sq cm, in 2nd class hardwood, complete all as specified and directed by Engr-In- Charge
M&L for Providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and directed by Engr-In- Charge
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-In- Charge.
S&F 75 mm brass handle, cast type , polished bright , complete all as specified and directed by Engr-in-Charge.
S&F sheet glass ordinary quality 4.00mm thick and glazing with oil putty in squares n.exc 0.5 sqm in each pane and fixing cabinet shutters with necessary screw/ fittings etc ,complete all as specified and directed by Engr-in-charge.
M&L for Stainless steel trolley made with perforated sheet not less than 1.52 mm thick and SS edging wire and slided over SS telescopic runner which is fixed to wall/stone with suitable screws of desired shape and size ,complete all as specified and directed by Engr-in-charge.
S&F Stainless steel soft close hydraulic action hinge with capacity to take load of 12 to 20 mm thick board ,complete all as specified and directed by Engr-in-charge.
S&F magnetic catches brass body and striking plate with aproved quality ,complete all as specified and directed by Engr-in-charge.
S&F heavy duty SS Zink plated telescopic runner for SS trolleys having fully extended length min 500mm and 45.4 mm wide, loading capacity 45 kg/pair including concealed screws and bolts fixed to the wall or stone ,complete all as specified and directed by Engr-in-charge.
M&L for Drilling holes of 25 mm dia through cuddappah stone and RCC slab together of thickness 100-250mm ,complete all as specified and directed by Engr-in-charge.
Removing existing water proofing treatment where so ever exist (except concrete padding) and removing debris/rubbish off the site ,complete all as specified and directed by Engr-In-Charge.
Demolition of cement concrete of any description and in any position provided as in roof padding, roof curb etc complete all as specified and as directed. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of debris/retrieved materials shall be thrown out of site at place as directed by the Engineer-in-Charge.
Material and labour for providing plain cement concrete type B- 1, (1:2:4) using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed. Note : (i) Minimum thickness of PCC shall be 50mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after
M&L for Opening out cracks, V section of wall/roof removing the loose material. Filling with cement mortar 1:3 ,complete all as specified and directed by Engr-In-Charge.
M&L for disconnecting existing over head tanks of capacity exc.500 and n.exc 1000 ltr, setting aside or lowering if required for repair of roof water proofing treatment and hoisting, reconnecting and re-fixing in position after necessary work without damaging to existing services etc (including tank nipple and float valve etc). ,complete all as specified and directed by Engr-In-Charge.
M&L Rendering 15 mm thick on fair faces of brick work or concrete /roof slab surfaces in cement mortar 1:4 finished with add mixture of Water prrofing compound etc complete all as specified and directed by Engr in Charge.(Note-WPC qty will be meassured and paid separately)
Supply only Integral Water Proofing compound ,complete all as specified and directed by Engr-In-Charge.
Material and labour for water proofing treatment with APP (APP membrane minimum 3 mm thick) based standard membrane over PCC padding in roof with the following courses of treatment for:- (a) Apply bituminous primer (IS 3384) @ 0.40 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (MAKE :IWL/STP/ TEXSA/BITUMAT/BITUNIL/SIKA) (b) Apply APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced(4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified. (Make of APP Membrane: Moply FP 3 mm mineral of TEXA/WP Shield 103 PM of SIKA or Equivalent material of BITUNIL/BITUMAT. (c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 kg/sqm prescribed by manufacturer complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil ,complete all as specified and directed by Engr-In-Charge.
Excavating in post holes (orsimilar holes) each n exc 0.5cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,hard/dense soil ,complete all as specified and directed by Engr-In-Charge.
M&L for Cement concrete Type D-2 1:48 (using 40mm graded stone aggregate) in foundations, filling and mass concrete ,complete all as specified and directed by Engr-In-Charge.
M&L Reinforced cement concrete (nominal mix) type B-1, 1:2:4 (using 20mm graded aggregate) Foundations, including rafts,footings, foundation beams;plinth beams; bases forcolumns, etc.; basement slabs,under-reamed piles and mass concrete ,complete all as specified and directed by Engr-In-Charge.
M&L for Providing reinforced cement concrete type B-1, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed ,complete all as specified and directed by Engr-In-Charge.
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surface of concrete ,complete all as specified and directed by Engr-In-Charge.
M&L Formwork to sides of pillars,posts,struts,piers,colums concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surface of concrete square/rectangular or polygonal ,complete all as specified and directed by Engr-In-Charge.
M&L Mild steel bars TMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip ,complete all as specified and directed by Engr-In-Charge.
Ditto as per Srl Item No 30.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders ,complete all as specified and directed by Engr-In-Charge.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe410 Gde-E-250 ,complete all as specified and directed by Engr-In-Charge.
S&F Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required thickness of sheet 1.25mm ,complete all as specified and directed by Engr-In-Charge.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) ,complete all as specified and directed by Engr-In-Charge.
S&F GI wire chain link fencing ( Minimum wt 2.5kg/sqm) minimum 2.5mm thick (excluding PVC coat) mesh size 45mmx45mm , UV resistant ,1mm dia PVC coated (Overall thichness of coating) with dia of GI wire 3.015mm , etc including fixed to any type of standards ,rails,straining bolt and provision of binding wire ,complete all as specified and directed by Engr-In-Charge.
M&L preparation of newly steel surface of any description over 10cm width or girth not otherwisw described two coat of synthetic enamel paint over a coat of red oxide primer ,complete all as specified and directed by Engr-In-Charge.
M&L preparation of old steel surface of any description over 10cm width or girth not otherwisw described two coat of synthetic enamel paint over a coat of red oxide primer ,complete all as specified and directed by Engr-In-Charge.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 ,complete all as specified and directed by Engr-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. hard /dense soil ,complete all as specified and directed by Engr-In-Charge.
M&L preparation of new surafce and applying three coat of white wash on walls ,complete all as specified and directed by Engr-In-Charge.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed ,complete all as specified and directed by Engr-In-Charge.
Opening cover de-watering and taking out sludge from septic tank of any size and removing sludge out side MD land and cleaning the septic tank as per BMC rules and placing cover in original position. Note :- The measurement for the quantity sludge removed will be arrived by multiplying the inner dimensions of septic tank to actual depth of sludge deposited by dipping the measuring rod. The depth shall be of that wet surface on measuring rod for payment purpose.
Opening cover and taking out accumulated garbage deposited such as brick bats, pebbles sand ,silt from gulley traps and cleaning of gulley traps including drain pipes upto first manhole not exceeding 3 metres away and removing the same to outside MD land and placing the cover in orginal position complete all as specified as directed. Note: All T&P including labour shall be provided by the contractor at their own cost.
Opening cover and taking out accumulated garbage deposited such as brick bats, pebbles sand ,silt (night soil excreta etc)from Man Holes of depth not exc 1.5m and cleaning of man hole as per BMC rules and placing the cover in orginal position complete all as specified as directed. Note: All T&P including labour shall be provided by the contractor at their own cost.
Opening cover and taking out accumulated garbage deposited such as brick bats, pebbles sand ,silt (night soil excreta etc)from Man Holes of depth exc 1.5m and cleaning of man hole as per BMC rules and placing the cover in orginal position complete all as specified as directed. Note: All T&P including labour shall be provided by the contractor at their own cost.
Systematically cleaning of 150 mm dia pipe sewage/drains by passing rope knots, bumboos kampti and disc of required size from manholes to manholes septic tank and well flushing after cleaning sewer line/drain pipe with water (excluding manholes and septic tanks) including safety measures such as test for gas etc,complete all as specified and directed by Engr-In-Charge.
Demolition of RCC Manhole covers, slabs etc of any description and in any position not specifically provided for ,complete all as specified and directed by Engr-in-Charge.
M&L for Salt glazed stone ware drain pipes grade 'A' internal dia of pipe 200 mm laid in trenches and jointed in cement mortar 1:1 complete all as specified.
M&L for Salt glazed stone ware drain pipes grade 'A' internal dia of pipe 150 mm laid in trenches and jointed in cement mortar 1:1 complete all as specified.
M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars 200 mm laid in trenches and jointed in cement mortar 1:1 complete all as specified.
S&F for Steel Fiber Reinforced Concrete (SFRC) cover and frame (heavy duty HD-20 grade designation)of suitable size as per requirment confirming ti IS-12592,total weight of cover and frame shall not be 100kg ,with temp variation range from -40 degree C to +80 degree C shall be water proof ,durable non corrosive,theft proof and shall be fixed in cement concrete complete all as specified.
M&L cement Concrete bed to drain pipes including packing under and completely surronding pipes after they are laid and tested in cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) bore of pipe is 150 mm complete all as specified.
M&L cement Concrete bed to drain pipes including packing under and completely surronding pipes after they are laid and tested in cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) bore of pipe is 200 mm complete all as specified.
Supply and fix in repairs salt glazed stone ware gulley traps, square or round mouthed type 'P' of size 150 mm x 150 mm complete all as pecified.
Demolition of brick work or stone boulder masonry built in cement mortar complete all as specified
M&L for Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius with old size bricks built in cement mortar 1:4 ,complete all as specified and directed by Engr-In-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc ,complete all as specified and directed by Engr-In-Charge.
Rendering 10 mm thick in repair on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound including finished even and smooth without using extra cement ,complete all as specified and directed by Engr-In-Charge.Note: Water proofing compound will be measured and paid seperately.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping benching for manholes etc including weathering slighting rounded or chamfered angles and throuting including necessary formwork as directed by Engineer-in-Charge.
M&L for RCC 1:2:4 type B1 using 20mm graded broken stone aggregate as in precast cover slab for man hole etc. and setting in cement mortar 1:4 (Note:- Reinforcement shall be measured and paid seprately ) ,complete all as specified and directed by Engr-in-Charge.
M&L for Cutting into existing manholes for connect in new drains making good to pipe and rendering cutting out existing benching for and forming branch channel ½ round or ¾ section in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150mm ,complete all as specified and directed by Engr-in-Charge.
S&F ,in repair ,PVC (SWR) pipe 75mm bore of pipe, single socket in any length with rubber ring joint, fixed to walls /Floor ,complete all as specified and directed by Engr-in-Charge.
S&F ,in repair ,PVC (SWR) pipe 110mm bore of pipe, single socket in any length with rubber ring joint, fixed to walls /Floor ,complete all as specified and directed by Engr-in-Charge.
S & F in repair PVC (SWR) bends 75 mm dia with access door,complete all as specified and directed by Engr-in-Charge.
S & F in repair PVC (SWR) bends 110 mm dia with access door ,complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) branch pieces, single(equal or unequal) or with parallel branches 75 mm dia ,complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) branch pieces, single(equal or unequal) or with parallel branches 110 mm dia ,complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) branch pieces, double 'Y' shape (equal or unequal) or with parallel branches 110 mm dia , all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) junction, single 'T' (equal or unequal) 110 mm dia ,complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) junction, double 'T' (equal or unequal) 110 mm dia ,complete all as specified and directed by Engr-in-Charge.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frame n exc 1.5 sq. m each complete all as specified and directed by Engr-in-Charge.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frame exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed by Engr-in-Charge.
M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge
M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
M&L for 3.00 mm thick plain sheet ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified
M&L for 3.00 mm thick plain sheet ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around opening, all complete as per requirement and direction of Engineerin- charge. complete all as specifed
M&L machine cut cudappa stone slab 15-20mm thick over 15 mm thick 1:4 cement mortat as backing coat base as in jambs and soffits of lintel laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed by Engineer-in-charge
M&L for Providing, cement concrete(1:3:6) tpye C-1 (20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
S&F aluminium anodized barrel tower bolt extruded section and fixed 150 mm long complete all as specified and directed by Engr-in-Charge.
S&F extruded aluminium alloy handles 100mm fabricated type, anodised complete all as specifed
S&F mild steel Butt hinges medium weight ,colled rolled100mm complete all as specifed
S&F stainless steel wire mesh of 0.36mm dia of wire and average width of aperture 1.40mm & fixed with tinted tacks of galvanised over staples ,complete all as specified and directed by Engr-in-charge.
M&L for Hanging only ceiling fan (MD Supply ) and connecting up including provn of cable from ceiling rose or connector to fan ,complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fan, seiling cable end,dismatling blades and removing fan and blades to store ,complete all as specified and directed by Engr-In-Charge.
Supply and Fixing Anti suicide Fan rod with and including all fitting accessories ,complete all as specified and directed by Engr-In-Charge.
Supply,laying and testing of XLPE insulated,screened,PVC bedded ,galvanized steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core ,complete all as specified and directed by Engr-In-Charge.
S&F GI pipe ,light grade of size 40mm dia fixing on pole/laid in trenches ,complete all as specified and directed by Engr-In-Charge.
M&L for boring for road crossing in any type of soil/rock strata ,complete all as specified and directed by Engr-In-Charge.
S&F LED street light fitting of 90 Watt ,230 Volt AC IP-66 ,complete all as specified and directed by Engr-In-Charge.
S&F Junction box with fuse provn and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting with controlled MCB SP-6 Amps -01 Nos enclosed in thermo plastic closed shock proof arrangement ,complete all as specified and directed by Engr-In-Charge.
S&F Pre-stressed concrete pole of 9 meter long having size 152mm x 260mm at bottom ,including foundation and coping ,complete all as specified and directed by Engr-In-Charge.
S&F bracket suitable for PCC pole including supporting arm with 40mm dia with light grade GI pipe inclined 108 degree for mounting of LED fittings ,complete all as specified and directed by Engr-In-Charge.
S&F Digital timer switch box complete with all accessories like , digital timer 20 Amp, Contactor 32 Amp,MCB TPN 32 Amp and relay complete fitted insie box of thickness 2mm alongwith indicating lamp ,complete all as specified and directed by Engr-In-Charge.
M&L for sub main wiring with 4 Single core 6 Sqmm PVC insulated, FRLS cable with multicore copper conductor drawn into and including steel conduit rigid metallic of suitable dia with and including independent PVC insulated one run 6 Sqmm single core earth wire ,complete all as specified and directed by Engr-In-Charge.
S&F MCB 40 Amp suitable for 415 Volts AC supply ,TPN with over load and short circuit protection and rupturing capacity not less than 10 KA ,complete all as specified and directed by Engr-In-Charge.
M & L for point wiring complete with 1.5 Sqmm (Nominal area) PVC insulated multustranded fire retardant (low smoke unsheathed and multicore copper conductor cable with colour code ISI marked and including PVC concealed conduict ISI marked and conduit fittings for one light point/fan point/5 Amps switch socket/bell/engagement light controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified (Cost of MS sunken box and bakelite sheet included in the rate). ,complete all as specified and directed by Engr-In-Charge.
S&F Switch flame proof rotary type with termination box in LM6,16 Amp,single pole 250 Volt ,complete all as specified and directed by Engr-In-Charge.
S&F Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked ,complete all as specified and directed by Engr-In-Charge.
S&F flame proof Distribution board single door made out of Aluminium housing with powder coating surface mounting SPN 4 Way 240 Volt with bus bar rating 200 Amp dust and vermin proof suitable for incorporation of MCB and isolators etc ,complete all as specified and directed by Engr-In-Charge.
S&F MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 5 to 32 Amps ,complete all as specified and directed by Engr-In-Charge.
S&F MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 32 Amps ,complete all as specified and directed by Engr-In-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to DBs /LT Panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, PCC 1:3:6 type C2 for earthing pit ,ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.Note:1.After completion if test results are not satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing.3.Earth resistance of earth pit should be less than 2 Ohms.
S&F LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas /vapour group of II A &II B , zone 1&2,IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver ,holder,connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable ,complete all as specified and directed by Engr-In-Charge.
MSK Everlast Enterprises
Vinod Enterprises
M/S VISHRANTA CONSTRUCTION
Safe Construction Co.
Nissan Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .