Vinod Kumar AE (Civil) AGE BR II Offg GE(S) Bathin
GE(S)Bathinda Bathinda Mil Stn
GE(S) BTD TOKEN NO 51 OF 2023-24 ROOF TREATMENT INCLUDING RELATED BR WORKS IN ZONE J K AND L AREA AND COMPREHENSIVE MAINTENANCE INCLUDING ATTENDING DAT TO DAY COMPLAINTS REPAIR REPLACEMENT OF JOINERY TANK CLEANING AND CERTAIN OTHER MISC WORK INCLUDIN
2023_MES_613758_1
GE(S)/BTD/TOKEN NO 51 OF 2023-24
Open Tender
Civil Works
Item Rate
330 days
GE(S)Bathinda
Class D
category a(i)
11 documents required · 11 mandatory
₹500
GE(S)Bathinda
₹96,000
Yes
20 Nov 2023
14 Aug 2023
6 Sept 2023
14 Aug 2023
4 Sept 2023
28 Aug 2023
Amount
Taking down cement or cement lime plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick walls built in CM (1:4), etc complete all as specified and as directed.
M&L brick work with sub class `B' bricks straight or curved on plan exc 6.0m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Taking down or up 15 mm bore galvanised iron tubing/PL-AL-PE pipes and connection including cleaning for refixing or removal etc complete all as specified and as directed.
Taking down or up 20 mm bore galvanised iron tubing /PE-AL-PE pipes and connection including cleaning for refixing or removal etc complete all as specified and as directed.
Taking down or up 25 mm bore galvanised iron tubing /PE-AL-PE pipes and connection including cleaning for refixing or removal etc complete all as specified and as directed.
S & F GI tubing 15mm bore medium grade with all fittings and fixed to walls & ceilings or laid in floors, complete all as specified and as directed.
S & F GI tubing 20mm bore medium grade with all fittings and fixed to walls & ceilings or laid in floors, complete all as specified and as directed.
Refixing inculding cleaning of 15 mm old steel tubing and connections in new or old position (Walls, ceiling, floors) etc complete all as specified and as directed.
Refixing inculding cleaning of 20 mm old steel tubing and connections in new or old position (Walls, ceiling, floors) etc complete all as specified and as directed.
Supply and fixing to walls/ chases/ ceiling or laying in floors polythene –aluminium- polythene (PE-AL-PE)composite pressure pipe 1620 (Out side dia-20mm) including all type internal sealing , plastic-metal composite fittings (such as elbows, reducers, tees, couplers, short pieces connectors etc. complete all as specified and directed.
Supply and fixing to walls/ chases/ ceiling or laying in floors polythene –aluminium- polythene (PE-AL-PE)composite pressure pipe 2025 (Out side dia-25mm) including all type internal sealing , plastic-metal composite fittings (such as elbows, reducers, tees, couplers, short pieces connectors etc. complete all as specified and directed.
Repair to concealed PVC (PE-AL-PE) pipes on walls including replacement of fittings (such as elbows, tees, reducers, couplers, short pieces, connectors, etc.), making joints leak proof and making good in CM 1:3 or PCC 1:2:4 (repair/replacement of tiles shall be measured & paid separately), complete all as specified and as directed.
S & F in repairs plastic-metal composite fittings (such as elbows, Tees, reducers, couplers, connectors/unions, etc) suitable for PE-AL-PE composite pressure pipes of 1620 (outside dia 20mm) etc complete all as specified and as directed.
S & F in repairs plastic-metal composite fittings (such as elbows, Tees, reducers, couplers, connectors/unions, etc) suitable for PE-AL-PE composite pressure pipes of 2025 (outside dia 25mm) etc complete all as specified and as directed.
Refixing old Polyethylene-Aluminium-Polyethylene (PE-AL-PE) composite pressure pipes 2025 (25mm outer dia) and connections in new or old position as on walls ceiling floors etc complete all as specified and as directed. (i) Cleaning of pipe is included in ser No 6 here in before (ii) Rates quoted by the contractor deemed to be included S & F new fittings as required.
Refixing Polyethylene-Aluminium-Polyethylene (PE-AL-PE) composite pressure pipes 1620 (20mm outer dia) including all type internal sealing Plastic-Metal Composite fittings(such as elbows, Tees, reducers, couplers, short pieces, connectors, etc) and hooks/clamps etc complete all as specified and as directed. (i) Cleaning of pipe is included in ser No 5 here in before (ii) Rates quoted by the contractor deemed to be included S & F new fittings as required
S&F in repairs 110 mm bore of pipe PVC (SWR) pipes single socket in any length with rubber ring joint fixed to walls with MS clamps etc complete all as specified and as directed.
S & F 110 mm bore, PVC (SWR) fittings such as bends of any radius, tee, shoe etc; fixed to PVC pipes, etc complete all as specified and as directed.
Fixing in repairs 110 mm bore of pipe PVC (SWR) pipes single socket in any length with rubber ring joint fixed to walls with MS clamps etc (except pipes) etc complete all as specified and as directed.
S & F in repair ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of size 20mm bore ( weight 210 gms Minimum) etc complete all as specified and directed.
Disconnecting exc 500 and not existing tanks 1000 ltrs capacity, setting aside (or lowering if reqd) for repairs, cleaning etc and hoisting if reqd reconnecting and re-fixing in position, etc complete all as specified and as directed.
Disconnecting exc 250 and not existing tanks 500 ltrs capacity, setting aside (or lowering if reqd) for repairs, cleaning etc and hoisting if reqd reconnecting and re-fixing in position, etc complete all as specified and as directed.
S&F in repair Rotational moulded polyethylene water storage tanks 1000 ltr capacity, triple layer white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F in repair Rotational moulded polyethylene water storage tanks 500 ltr capacity triple layer, white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
Supply only Integral water proofing compound make:- fixit(as per manufacture's specification), etc complete all as specified and as directed.
M & L 15 mm thick rendering in CM (1:4) on any faces of brick work or concrete surfaces and finished even and smooth without using extra cement , etc complete all as specified and as directed.
M & L for applying two coats of cement base paint over a coat of primer on newly plastered wall surfaces including preparation of these surfaces and matching the colour/tint with existing surfaces, etc complete all as specified and directed.
M& L applying two coats of exterior emulsion paint over a coat of primer on newly plastered wall surfaces including preparation of these surfaces and matching the colour/tint with existing surfaces or colour, etc complete all as specified and as directed.
Cutting or uprooting grass on mud phuska roofs , vertical stacks , shaft , RCC chajja's etc removing rubbish off the premises, cleaning surface and preparing to receive new cement pointing, etc complete all as specified and as directed.
M& L for raking out joints / grouting incl Pointing in cement mortar to brick tiles 30 cm by 15 cm laid flat, in floors , roofs ceilings chajjas etc complete all as specified and as directed.
M&L flush pointing in cement mortar 1:3 to bricks laid flat or brick tiles in pavings, etc complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layer on roof and disposal off retrieved material upto a distance of 100m where directed, etc complete all as specified and as directed.
Demolition of mud in roof any thickness including plastering and leaping and disposal of rubbish upto a distance n.exc 100m where directed, etc complete all as specified and as directed.
M&L for wire brushing and cleaning top surfaces roof slabs etc including washing the roof surface with water and making the surfaces free from mud etc complete all as specified and directed.
M&L rendering 15mm thick (avg thickness) on roof surface including flashing and junctions of parapets etc finished even and fair in CM 1:3 mixing with WPC as per recommended ratio after brushing cement slurry @ 1.2 Kg/Sqm all as specified (WPC to be measured and paid separately), etc complete all as specified and as directed.
Priming surfaces and applying APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application as treatment(for moderate conditions) including after applying bituminous primer @ 0.5 Lt/Sqm over RCC/plastered roof surface and flashing etc complete all as specified and as directed.
M&L for two coats of aluminium paint over APP sheet etc complete all as specified and directed.
M&L for cement concrete using 40mm thick brick aggregate laid to slope over RCC roof as padding, etc complete all as specified and as directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 etc complete all as specified and as directed
Making benching with PCC (1:2:4) type B0 using WPC along side wall adjoining to roof in kerb and or mud chamfered on edges etc complete all as specified and as directed.
Factory made 250mmx250mm size and 20-25mm thick PCC tile with grey cement and no pigment bedded over15mm thick cement mortar 1:4 joints grouted flush in CM 1:3 mixed with 5% of crude oil by weight of cement on lime concrete, etc complete all as specified and as directed.
First quality , straight cut/joint free , scratch free , vitrified pavers/tiles , 10 mm thick of size 300 mm x 300 mm , in floors , set and jointed with gray cement slurry , over & including 150mm thick cement mortar 1:4 screed , set and jointed with gray cement slurry & pointed with grout of matching shade etc complete all as specified and as directed
M&L apply for a layer of hot blown bitumen of 85/25 penetration grade @ 1.75 kg/Sqm incl cleaning the surface of roof or sunken etc complete all as specified and as directed.
Comprehensive maintenance for Carpentry work by attending day to day complaints of joinery related such as replacement of Builders hardware of doors, windows & cupboard and other Carpentry nature works like easing of door, windows and cupboards. Tightening of screws for tower bolt/AL drop bolt/ stoppers ,handle hinges in respect to Easing of door / windows/cupboards (Steel Wooden/Aluminium) of any description and size by cleaning, adjusting in position and making the same functional incl small repairs if reqd with and incl greasing, oiling, screws/nails for fixing the fittings, etc complete all as specified and as directed.
Comprehensive maintenance to masonry work by attending day to day complaints of masonry related works such as plastering of wall/ceiling/chajja/making of jambs,soffit,cills etc of size not exceeding 0.25 sqm or on patch work including finishing with distemper/white wash/cement based paint/exterior emulsion paint including two coats of putty as required at site to match with existing surface, etc complete all as specified and as directed.
Comprehensive maintenance to plumbing work by attending day to day complaints of plumbing nature like leaking bib taps, stop cock of any pattern or of any type including minor repairs to flush cistern, repair to PE-AL-PE composite pressure pipe/GI pipe leakages, removing air blockages if any and refixing old serviceable bib cocks, stop cocks any pattern after minor repairs such as replacement of washers, jumpers and spindle etc complete all as specified and directed. Minor items like thread , Teflon tape, rubber washer shall be deemed to be included in the quoted rates. (any major parts such as jumpers, brass spindles ,caps etc to be measured as supply only and paid for accordingly), complete all as specified and as directed. Note for item No 45 to 47. The scope of work is of day to day maintenance nature/ requirement of works. Contractor shall attend the office of AGE B/R-I on daily basis and receive/ collect the complaints/ requirements of works and shall rectify the repair/maintenance works within time given below :- (a) Minor plumbing complaints - 48 hours (b) Minor Joinery complaints - 48 hours (c) Minor masonry complaints - 48 hours (d) Major Plumbing - 5 days (e) Major Joinery - 15 Days. If contractor fails to rectify the complaints with materials/ items to be replaced if required a penalty @ 50% of quoted rate by the contractors of that particular item shall be recovered from his payment. The responsibility of getting the complaints attended & rectified shall lies with the contractor even if he fails to complete the complaints within 48 hours. In the delayed case of a rectification of complaints even after 48 hours, he shall rectify the same within one week. (Note :- The complaint received from complaint cell shall have to be attended on same day). etc complete all as specified and as directed.
Demolition of cement concrete (unreinforced) including tiles of any description & terrazzo finish, etc. in ground floors and paving n. exc 15 cm thickness (below or above ground level) etc complete all as specified and as directed.
M & L 75mm thick, cement concrete 1:3:6, type C2 (40mm graded aggregate) as in floors, plinth protection, paths, etc and finishing top surfaces even and smooth (without using extra cement) etc complete all as specified and as directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 but except bricks (old serviceable bricks to be used) complete all as specified and directed. Note : The rate includes for cleaning of old bricks.
M & L 15 mm thick rendering in CM (1:6) on brick surfaces or conc surfaces on walls and finished even and smooth without using extra cement etc complete all as specified and directed.
M & L for rendering 5 mm thick on concrete surfaces such as ceiling or soffits of chhajas etc; in CM 1:3 finished even and smooth without using extra cement etc complete all as specified and directed.
M &L for applying two coats of white wash on newly plastered ceiling surfaces including preparation of these surfaces etc complete all as specified and as directed.
M&L for applying two coats of oil bound distemper ( to match with the adjacent shade or tint) over a coat of chalk whitening on newly plastered wall surfaces including applying wall putty to make up depression etc and to the surface even & smooth including preparation of these surfaces etc complete all as specified and as directed.
M&L applying three coat of white wash on newly plastered surfaces on wall including preparation of surface, etc complete all as specified and directed.
M & L Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bedding layer in CM 1:6 and including roughening surfaces of old concrete/terrazzo finish floor by picking, sweeping clean and washing down with water to remove dust etc/ dismantling old tiles of any description, etc complete all as specified and as directed.
M & L Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, on vertical surfaces as in skirting etc. set and jointed in neat cement slurry/paste and pointed in white or coloured cement to match over and including 10mm thick plaster in CM 1:4 including taking down old plastered/terrazzo finishes/old tiles etc complete all as specified and as directed.
M&L non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed in CM 1:6 etc complete all as specified and as directed.
M&L non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed in CM 1:4 and including dismantling of old tiles/terrazzo finish etc complete all as specified and as directed.
S&F glazed ceramic dark coloured tiles 300x200mmx6mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in CM 1:4 on brick surface and taking down of old existing treatment & plaster, scrubbing down with water and disposing off the wastage to low laying areas to a distance exceeding 50 Mtr but not exceeding 100 Mtr away complete all as specified and directed. Make:- Orient,Kajaria,Bell ceramic Johnson, etc complete all as specified and as directed.
M & L glazed ceramic coloured tiles 7mm thick 350mmx 250mm/450mmx300 mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade etc complete all as specified including 10mm thick plaster in CM 1:4 including dismantling of old tiles of any description etc complete all as specified and directed.
M&L in repairs marble work (Udaipur green slabs) 18 to 20mm thick (table rubbed and polished) as in cooking platforms and like in cement mortar (1:4) in pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade all as specified (Note : Rates deemed to include for provision hole through marble & RCC slab for LPG gas pipe and rounding and polishing of edges of marble slab), etc complete all as specified and as directed.
M&L for Dismantling Stone slabs and tiles of any description or thickness in floors, aprons & shelves laid bedded and pointed in any mortar etc complete all as specified and as directed.
S&F in repairs Stainless steel Galvanised wire cloth 0.36mm nominal dia of wire and 1.40 mm average width of aperture fixed with tinned tacks or Galvanised wire staple, etc complete all as specified and as directed.
S&F for Galvanised Stainless steel wire cloth 0.36 mm nominal dia and wire and average width of aperture 1.40mm fixed with tinned tacks or Galvanised wire staples, etc complete all as specified and as directed.
S & F in repairs 300mm mild steel ordinary rat tail rod springs, including roller & roller plate and welding to steel frame etc complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/springs clips, etc complete all as specified and as directed.
S & F 3.0mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc 0.50 Sqm in each pane etc complete all as specified and as directed.
S & F 4.0mm thick figured glass, pin head type and glazing with oil putty in squares n. exc 0.50 Sqm in each pane etc complete all as specified and directed.
S&F in repairs tank nipple suitable for HDPE water tank (minimum weight 20 mm - 45 gms) etc complete all as specified and directed .
M&L for 25mm dia fancy type PVC coated on MS pipe coloured curtain rod with brackets and knobs at both ends as per site requirement including taking down old existing PVC conduit pipes with accessories etc complete all specified and as directed.
S&F in repairs PVC flexible waste pipe with socket suitable for connection to Waste fittings of 32/40mm dia, and of length minimum 75 cm etc complete all as specified and directed.
Refixing only old GI tubing 15 mm bore pipe and connections in new or old position as on walls ceiling floors etc complete all as specified and directed. (i) Cleaning of pipe is included in Ser No 4 & 5 here in before (ii) Rates quoted by the contractor deemed to be included S & F new fittings as required Make: Tata/Prakash/Jindal ISI mark
S & F in repairs 15mm bore brass bib taps , screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 15mm bore pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe etc complete all as specified and directed.
S & F in repairs PVC lid (cover) for 500 to 1000 ltr capacity PVC water tanks with hinging & locking arrangement complete all as specified and directed.
S & F in repair ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of size 20mm bore ( weight 210 gms Minimum) complete all as specified and directed.
S & F in repairs, brass chromium plated shower rose 125mm dia, with swivel joints & and arms, and fixing to pipe & union etc complete all as specified and directed.
S & F in repairs 15mm bore, fancy type , chromium plated, angle valve, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe etc complete all as specified and directed.
S & F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality, etc complete all as specified and as directed.
S & F in repair PVC valve less, symphonic action type flushing cistern, low level, with inlet ball valve, float and handle including brackets, PVC bend long type and connecting to flush pipe of any size and pattern etc complete all as specified and directed.
S & F in repair vitreous china wash basin, white, flat back, size 550 x 400mm excluding taps, wastes but including brackets etc complete all as specified and directed.
S & F in repairs sinks without drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall / RCC shelve and connecting union to pipe overall size 495mm x 420mm bowl complete all as specified and directed.
S & F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x460mm bowl size 410mm x330mm x160mm complete all as specified and directed.
S&F in repairs stainless steel plate racks of size 900mmx600mmx250mm and thickness of SS strip 1mm, fixed on wall etc complete all as specified & directed.
S & F in repairs brass chromium plated tubular towel rail, 20mm dia, D type 60cm long between flanges etc complete all as specified and directed.
S & F in repairs 15mm bore fancy type chromium plated brass bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 15mm bore fancy type chromium plated stop valve cast copper alloy, with long shank & cup (concealed type) with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs brass chromium plated bottle traps for wash basins with inlet and out let screwed for pipe or connections including necessary packing, union and cap etc complete all as specified and directed.
S & F in repairs 32/40mm waste fittings, brass chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and flynuts, flange end bedded in red lead cement complete all as specified and directed.
S & F in repairs 32/40mm waste fittings for stainless steel sink(sink coupling) , brass chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and flynuts, flange end bedded in red lead cement complete all as specified and directed.
S & F in repairs CP grating (with or without waste hole), 125 mm size, fixed on floor/nahani traps etc complete all as specified and directed.
S & F in repairs 110 mm bore of pipe PVC (SWR) pipes single socket in any length with rubber ring joint fixed to walls with MS clamps etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) fittings such as bends of any radius, tee, shoe etc; fixed to PVC pipes, complete all as specified and directed.
Supply and fixing in repairs bib cock PTMT standard 15 mm dia of any colour, high pressure screwed for iron pipe & fixed ( male or female as required) complete all as specified and directed.
Supply only Jumper brass with rubber or leather washer complete for 15 mm dia bib cock / stop cock brass complete all as specified and directed
Supply only spindle brass for 15 mm dia CP Bib cock/ pillar cock/ concealed cock of any pattern complete all as specified and directed.
Supply only capstan head / cap of CP bib tap / CP stop cock 15 mm size complete all as specified and directed.
S & F in repairs 20mm bore, gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F in repairs vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor and fixed complete all as specified and directed.
Fixing only in repair vitreous china wash basin, of any description & size, excluding taps, wastes but including brackets complete all as specified and directed.
S&F in repair flush pipe of polyethene of low or high density or PVC, 32mm dia, for low level cistern and fixed complete all as specified and directed.
Dismantling and disconnecting of existing CI soil vent pipe 100 mm bore fixed to wall, laid in trenches incl all fittings & accessories, complete all as directed and directed.
S & F cast iron soil waste and vent pipe 100mm bore with or without ears fixed with chemical cement joints laid in trenches/floors or fixed in walls, complete all as specified and directed.
Fixing only cast iron soil waste and vent pipe 100mm bore with or without ears fixed with chemical cement joints laid in trenches/floors or fixed in walls, complete all as specified and directed.
Sealing only joints of cast iron pipes and fittings 75/100mm dia with chemical cement and making the joints leak proof complete all as specified and directed.
S&F in repairs oval access doors to cast iron pipes of 100mm bore with rubber washer & bolts & nuts as required complete all as specified and directed.
S & F in repairs CI bends any radius, 100mm bore, diminishing pieces or tapers, etc with or without oval access doors, complete all as specified and directed.
S & F in repairs 100mm bore CI branch pieces, double (spigot or socketed type) with oval access doors etc complete all as specified and directed.
Fixing only CI fittings 100mm bore of any type & description etc complete all as specified and directed.
S & F in repairs mild steel Butt Hinges, 100 mm size, medium weight, cold rolled fixed with screws/welding to wooded/steel frames or chowkats, complete all as specified and directed.
M&L welding in repairs with thickness of metal not exceeding 6mm and not exceeding 2.5 cm in length etc complete all as specified and directed.
M&L in repairs 2nd class HW plain fillets, square, rectangular or triangular in section, wrought, secured with nails/brads or secured with screws, cross sectional area exc 6 sqcm and n. exc 13 sqcm, complete all as specified and directed.
S & F 200 mm aluminium anodised, barrel tower bolts of extruded section etc complete all as specified and as directed.
Supply and fixing 150 mm long aluminium handles, fabricated type, anodised and fixed complete all as specified and directed.
S&F for MS tower bolt 200 mm long stove enamelled black with bright bolt, etc complete all as specified and as directed.
S&F for MS sliding door bolt 250 mm long stove enamelled black with bright bolt etc complete all as specified and as directed.
S&F for MS pressed handles, oval type stove enamelled black 150 mm long etc complete all as specified and as directed.
S&F in repair MS tower bolt 200 mm long stove enamelled black with bright bolt etc complete all as specified and as directed.
S&F in repair MS pressed handles, oval type stove enamelled black 150 mm long etc complete all as specified and as directed.
S & F in repairs 200 mm aluminium anodised, barrel tower bolts of extruded section etc complete all as specified and as directed.
Supply and fixing in repair 150 mm long aluminium handles, fabricated type, anodised and fixed complete all as specified and directed.
S&F in repair PVC Knob/Handle (as per sample) for 10 ltr capacity PVC low level flushing cistern complete all as specified and directed.
S&F in repair PVC Syphon Kit (as per sample) for 10 ltr capacity PVC low level flushing cistern complete all as specified and directed.
S&F in repair complete Veta washer set (as per sample) for 10 ltr capacity PVC low level flushing cistern complete all as directed.
Fixing only in repair low level flushing cistern any capacity after carrying out minor repairs such as stopping of leakage etc. complete all as specified and directed.
Renewing non skid /glazed ceramic tiles in patches in floor or walls, area n. exc 5 sqm including cutting out broken tiles carefully, preparing beds and laying or setting, jointing & pointing new tiles complete all as specified (new tiles shall be paid at supply only rate separately), etc complete all as specified and as directed.
Cutting chases in brick walls girth exc 10 cm but not exc 20 cm wide for concealed water tubing etc and making good in CM 1:3 or PCC 1:2:4 as required complete all as specified and directed.
Dismantling carefully cement concrete in floor, etc around floor traps or any other concealed fittings, ( replacing floor traps/fittings if required and shall be paid at supplied only rate separately), sealing joints with solvent cement or other suitable materials and making joint leak proof and making good surfaces with PCC 1:2:4 or CM 1:3 (repair/replacement of tiles in floor shall be measured and paid separately), etc complete all as specified and as directed.
Supply only floor trap 75/100 mm dia with grating including jointing to waste pipe, etc complete all as specified and as directed.
Supply only non skid ceramic coloured tiles 400 x400 x7mm thick, etc complete all as specified and as directed.
Supply only non skid ceramic coloured tiles 300 x300 x7mm thick, etc complete all as specified and as directed.
Supply only glazed ceramic coloured tiles 300 x200 x7mm thick, etc complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 using 40mm graded crushed/stone agg for foundations, filling & mass concrete, sub-base & sub-floors, etc complete all as specified and as directed.
M&L 25mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as floors, sub-floors etc and finishing surfaces of concrete topping as even & fair or even & rough to receive the topping layer etc complete all as specified and as directed.
M&L 15mm thick cement plaster in CM 1:4 with water proofing compound (WPC to measurement & paid separately) and finishing top surface even & smooth as in roof slab /sunken floor , etc complete all as specified and as directed.
Taking down chowkhats or frame n exc 1.50 Sqm each with shutters (W/out taking off shutters from the frames), etc complete all as specified and as directed.
Taking down chowkhats or frame exc 1.50 Sqm but n exc 4 Sqm each with shutters (W/out taking off shutters from the frames), etc complete all as specified and as directed.
Taking down shutters of any description exc 1 Sqm & nexc 2 Sqm each, etc complete all as specified and as directed.
S&F for pressed steel frames of size 125 X 60 mm with one or more rebates including necessary fixing lugs hinges, locks strike plate etc(thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6, etc complete all as specified and as directed.
S&F for pressed steel frames of size 105 X 60 mm with one or more rebates including necessary fixing lugs hinges, locks strike plate etc(thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6, etc complete all as specified and as directed.
M & L for PCC 1:3:6 type C1 (20mm graded stone aggregates) as in filling back of pressed steel door frames/chowkats and for fixing hold fasts, etc., complete all as specified and as directed.
S&F 2nd class HW 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass, gauze, etc.; sizes of members of shutters as specified in SSR Part I Section 8, Clause 8.24 (a) complete all as specified and as directed.
S & F 2nd class hardwood, factory made shutters, 35 mm thick plain framed paneled shutters (any number of panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both side. The size of rail & stiles as per IS :1003 (Part I), kiln seasoned and chemically pressure treated, etc complete all as specified and as directed.
S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube fixed in opening complete as per specifications & drawing, etc complete all as specified and as directed.
S & F for 30 mm thick factory made solid panel PVC door shutter confirming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 gauge thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C' channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of 'C' channel using PVC solvent adhesive complete as per manufacturers specifications & drawings, etc complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description exc 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description exc 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L Securing window/vent glass of any description in existing metal/wood frame fixed with putty/ beads including removing loose or decayed putty/beads, and painting/oiling puttied surface to match existing work (New length of frame reputtied shall be measured), etc complete all as specified and as directed.
M&L for stopping of leakage/Seepage in CI/PVC/GI pipes by using M-Seal etc complete all as specified and as directed.
S&F in repairs ( to be fixed with screws & welding as required) continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flap (when open) 30mm etc complete all as specified and as directed.
S&F in repairs 18/19mm thick pre-laminated particle board, interior grade, fixed with screws to timber frame work and steel frame work as in kitchen cupboards, drawers, shutters, shelves etc including teak wood lipping, 6mm thick on edges fixed with nails etc complete all as specified and as directed.
S&F for Al hasp and staple 100 mm size, etc complete all as specified and as directed.
Dismantling boarding any description fixed in any position with rails incl fillets, etc complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, ant-syphonage pipe, etc complete all as specified and as directed.
Fixing only in repairs vitreous china wash down water closet pan (pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, ant-syphonage pipe, etc complete all as specified and as directed.
S&F for steel windows/ventilators with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded, including steel window/ventilators complete all as specified and directed.
S&F for steel windows/ventilators with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with out glazing bars, , including steel window/ventilators complete all as specified and directed.
Supply and fixing steel windows or ventilators fixed type with glazing bars , including steel window/ventilators complete all as specified and as directed .
Taking down carefully existing copper/Aluminum point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, bell pushes, ceiling roses, pendants, regulators, sockets, light fitting, call bells etc removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete all as specified and directed.
Dismantling & taking down of existing unsv light fittings/fixtures for replacement complete all as specified & directed
Dismantling & taking down of existing unsv call bell for replacement complete all as specified & directed
Dismantling & taking down of existing unsv batten/angle holder for replacement complete all as specified & directed
M & L for Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the followings :- One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
One Socket outlet three pin, 6 Amp, on the same board, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified & directed
One Socket outlet three pin, 6 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
One Bell/Buzzer point controlled by one push button with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
One light point controlled by two way switch. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed Note for serial item No 181 to 185: 1. Switch(as) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. 2. GI boxes shall be fixed flush in position with cement mortar (1:4) complete all as directed.
S&F Switch modular type single pole, one way, 6 Amp, one module, complete all as specified & directed
S&F Switch modular type single pole one way, 16 Amp, one module, complete all as specified & directed
S&F Switch modular type single pole, two way, 6 Amp, one module, complete all as specified & directed
S&F Bell push switch modular type single pole one way, 6 Amp, one module, complete all as specified & directed
S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6 Amp, two module, complete all as specified & directed
S&F Socket outlet modular type multipurpose 2/3 pin single pole one way 6/16 Amp, two module, complete all as specified & directed
S&F Fan regulator, modular type, 5 step, high speed, two module complete all as specified & directed
S&F Ceiling rose, 3 terminal PVC/polycarbonate, suitable for 230 V, AC, 50 Hz supply complete all as specified & directed
S&F call bell ding dong type AC 230 V complete all as specified & directed
S&F wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 20watt, 1.2 m 6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver complete including making connection complete all as specified and directed.
S&F wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 25watt, 1.2 m 6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver complete including making connection complete all as specified and directed.
S&F decorative wall light fixture made of polycarbonate suitable for retrofit 9W LED lamp(base B-22) complete with PC diffusor & including one 9W LED lamp(base B-22), 6500K, not less than 90 lumen/watt efficacy including making connection complete all as specified and directed.
S&F round shape 6 watt 220V AC surface type with high efficiency PMMA diffusor soft glare free light complete with drivers, holders, LED lamps suitable for roof ceiling including making connection complete all specified and directed
S&F Lamp holder PVC/polycarbonate type with back plate complete all as specified & directed
S&F LED 7W lamp(base B-22) 6500K, not less than 90 lumen/watt efficacy complete all as specified and directed.
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm along with earth wire 6.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit and including complete all as specified & directed (Note:- Three lengths of 6 Sqmm cable will be measured as one length). (Note :- two lengths of 6.0 sqmm cable and one length of 6.0 sqmm earth cable will be measured as one running length)
S&F in replacement sheet metal encloser double door 12 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
-do- any per item No. 188 above but 04 way TPN 415V complete all as specified and directed
S&F in replacement single pole and neutral enclosure 240V with a two pin and earth plug and socket complete with one double pole MCB 20Amp complete all as specified and directed
S&F in repair MCB 6-32 Amp 240V SP 10 KA ‘B’ series complete all as specified and directed
S&F in repair RCCB EARTH LEAKAGE PROTECTION 230V 25A AC type Double pole 30mA ISI marked complete all as specified and directed
S&F in repair MCCB 415V, FP 63A 16kA complete all as specified and directed
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion including replacement of old unserviceable. Note:- It is mandatory to paint a sqaure shape notice board of yellow color with legible black color letters of earthing mentioned details as below; Cost incurred deemed to be included in quoted rate:- (i) CA No. (ii) Date of installation after initial testing & Value of earth resistance in Ohm (iii) Date of last testing (iv) Value of earth resistance in Ohm in last test
S&F in repair Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed
S&F in repair Switch piano, flush type single pole, two way 5 Amp complete all as specified and directed
S&F in repair Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed
S&F in repair Bell push 5/6 Amps 230 V AC complete all as specified and directed
S&F in repair Socket outlet 3 pin, 5A, flush type complete all as specified and directed
S&F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed
S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed
S&F in repair rigid non-metallic PVC conduit external dia 20mm in size inclusive of all tees, bends, elbows, reducers, junction boxes, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed
S&F in repair Hylam sheet cover 3mm thick of size 5"x5" complete with machine screw/ washer with provision of slots for switches, sockets, fan regulators (including refixing of all switches, sockets, fan regulators dismantled from existing sheets) complete all as specified and directed
S&F in repair Hylam sheet cover 3mm thick of size 8"x5" complete with machine screw/ washer with provision of slots for switches, sockets, fan regulators (including refixing of all switches, sockets, fan regulators dismantled from existing sheets) complete all as specified and directed
S&F in repair Hylam sheet cover 3mm thick of size 13"x8" complete with machine screw/ washer with provision of slots for switches, sockets, fan regulators (including refixing of all switches, sockets, fan regulators dismantled from existing sheets) complete all as specified and directed
S&F in replacement GI terminal box of size not less than 79mmx99mm with minimum depth 50mm & thickness not less than 18 gauge complete with earth dolly including making good the disturb surfaces CM (1:3) to match the existing complete all as specified and directed
S&F in replacement GI terminal box of size not less than 79mmx207mm with minimum depth 50mm & thickness not less than 18 gauge complete with earth dolly including making good the disturb surfaces CM (1:3) to match the existing complete all as specified and directed
S&F in replacement GI terminal box of size not less than 132mmx207mm with minimum depth 50mm & thickness not less than 18 gauge complete with earth dolly including making good the disturb surfaces CM (1:3) to match the existing complete all as specified and directed
S&F LED light fitting 9/10W bulkhead luminaires including LED light, driver, holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Note:- Net contract sum shall be calculated after deduction of Sch of credit.
RAMA AUTOS
JAGMEET SINGH CONTRACTOR
KULWANT RAI
ABHINANDAN ENTERPRISES
M/s PANKAJ KUMAR
Aman Enterprises
M/s Kamal Constructions
M/s Manav Builders
M/S KARTIK BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .