| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹38.4 L+₹3.0 L (8.53%)Rejected-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹38.6 L+₹3.3 L (9.21%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹40.9 L+₹5.5 L (15.7%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹41.0 L+₹5.6 L (15.8%)Rejected-Finance 894 NEAR 132 KV POWER HOUSE SINDHARI ROAD BALDEV NAGAR BARMER RAJ 344001 | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Jan 2025, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
REPAIR MAINT OF LT PANELS, FEEDER PILLARS BOX AND ALLIED WORKS UNDER GE (A) JAISALMER
2024_MES_689899_1
8447/24-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹80,000
Yes
11 Feb 2025
21 Dec 2024
20 Jan 2025
21 Dec 2024
18 Jan 2025
4 Jan 2025
Amount
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No( (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 600 Amps of size 60 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 400/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 320 Amp , breaking capacity 36KA with thermal release- - 1 Nos (b) MCCB 4 Pole of capacity 250 Amp , breaking capacity 36KA with thermal release- - 02 Nos (c) MCB TPN 63 Amps -02 Nos (e) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T (iv) Bus bar strips made of Aluminium 600 Amps of size 60 x10mm min 1 Mtr length – 04 Nos
aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance (v) CT 400/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 250 Amp , breaking capacity 36KA with thermal release- - 1 Nos (b) MCCB 4 Pole of capacity 200 Amp , breaking capacity 25KA with thermal release- - 02 Nos (c) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25 KA with thermal release -02 No (c) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16 KA with thermal release -01 No (d) MCB TPN 63 Amps 415 Volt 10 KA-02 Nos (e) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T- Part No- SIL-00000.
(iv) Bus bar strips made of Aluminium 600 Amps of size 60 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 400/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 250 Amp , breaking capacity 36KA with thermal release- - 03 Nos (b) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25 KA with thermal release -01 No (c) MCCB 4 Pole of capacity 125 Amp , breaking capacity 16 KA with thermal release -1 No (d) MCB TPN 63 Amps 415 V -02 Nos (e) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 400 Amps of size 40 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 250/5A) -03 Nos OUTGOING:-(a) MCCB 4 Pole of capacity 200 Amp , breaking capacity 25KA with thermal release- - 01 Nos (b) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25 KA with thermal release -01 No (c) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16 KA with thermal release -4 No (d) MCB TPN 63 Amps 415 V -02 Nos (e) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 400 Amps of size 40 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 125 Amp , breaking capacity 16KA with thermal release- - 02 Nos (b) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16 KA with thermal release- - 1 Nos (c) MCB TPN 63 Amp 415 V, -2 No (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- (Loc 694 tatra) Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T-
(iv) Bus bar strips made of Aluminium 400 Amps of size 40 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 250/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 03 Nos (b) MCB TPN 63 Amp - 02 No (c) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T- Part No- SIL-00000.
(iv) Bus bar strips made of Aluminium 400 Amps (Hindalco Make)of size 40 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 1 Nos (b) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 3 Nos (c) MCB TPN 63 Amp -1 No (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 400 Amps of size 40 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 1 Nos (b) MCCB 4 Pole of capacity 63 Amp , breaking capacity 16KA with thermal release- - 07 Nos (c) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make-L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 400 Amps of size 40 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 1 Nos (b) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 2 Nos (c) MCB TPN 63 Amp - 2 No (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T-
(iv) Bus bar strips made of Aluminium 400 Amps of size 40 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 1 Nos (b) MCCB 4 Pole of capacity 125Amp , breaking capacity 16KA with thermal release- - 1 Nos (c) MCCB 4 Pole of capacity 100Amp , breaking capacity 16KA with thermal release- - 1 Nos (d) MCB TPN 63 Amp - 1 No (e) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 200/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 2 Nos (b) MCCB 4 Pole of capacity 63 Amp , breaking capacity 16KA with thermal release- - 1 Nos (c) MCB TPN 63 Amp - 2 No (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 160 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T-
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 200/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 1 Nos (b) MCCB 4 Pole of capacity 63 Amp , breaking capacity 16KA with thermal release- - 2 Nos (c) MCB SPN 63 Amps -06 Nos (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 6 Nos (b) MCB TPN 63 Amps -01 Nos (c) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) MCCB 4P of capacity 160 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 02 No (iii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iv) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(v) Bus bar strips made of Aluminium 300 Amps (Hindalco Make)of size 60 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (vi) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 2 Nos (b) MCB TPN 100 Amps - 2 Nos(c) MCB TPN 63 Amps - 4 Nos (c) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 160 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 200/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 2 Nos (b) MCCB 4 Pole of capacity 63 Amp , breaking capacity 16KA with thermal release- - 2 Nos (c) MCB TPN 63 Amps - 02 Nos (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 200/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 3 Nos (b) MCCB 4 Pole of capacity 63 Amp , breaking capacity 16KA with thermal release- - 2 Nos (c) MCB TPN 63 Amps - 03 Nos (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 4 Nos (b) Change Over 200 Amps FP C -01 Nos (c) MCB SPN 63 Amps - 02 Nos (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 63 Amp , breaking capacity 16KA with thermal release- - 5 Nos (b) MCB TPN 63 Amps - 03 Nos (c) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 160 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T-
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 200/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 1 Nos (b) MCB TPN 63 Amps - 03 Nos (c) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 160 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 200/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16KA with thermal release- - 01 Nos (b) MCB TPN 63 Amps - 04 Nos (c) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T-
(iv) Bus bar strips made of Aluminium 300 Amps of size 30 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 200/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 16KA with thermal release- - 02 Nos ( b) MCCB 4 Pole of capacity 63 Amp , breaking capacity 16KA with thermal release- - 04 Nos (c) MCB TPN 63 Amps - 01 Nos (d) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 5 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations.
Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T-
(iv) Bus bar strips made of Aluminium 600 Amps of size 60 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 400/5A) -03 Nos (vi) Change Over 400 Amps FP -01 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 250 Amp , breaking capacity 36KA with thermal release- - 02 Nos (b) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25 KA with thermal release -03 No (c) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16 KA with thermal release -03 No (d) MCB TPN 63 Amps -01 Nos (e) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu
M&L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground levl connected to galvanized iron strip 32 x 6 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed.
NOTE FOR ITEM No. 23.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply and fixing MCCB 4 Pole 400 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 250 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 200 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 160 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 100 Amps, breaking capacity 16 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing UNSV / burnt MCCB complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 pole 63 Amps rupturing capacity 16 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge.
Supplying, laying, testing and commissioning of LT UG, XLPE insulated, heavy duty, 1100V grade of size 95 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old existing unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:- Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
All as per item No 30.00 above but of size 70 sq mm. 3.5 core
All as per item No. 30.00 above but of size 50 sq mm 3.5 core
All as per item No 30.00 above but of size 25 sq mm. 4 core
All as per item No 30.00 above but of size 16 sq mm 4 core
All as per item No 30.00 above but of size 10 sq mm 2 core
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/loose soil complete all as specified & directed by Engineer-in-Charge.
Removing excavated material soil/disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engr-in-Charge.
M&L for sand cushioning to underground cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50 mm thick roughly hammer dressed Jodhpur stone patti cable cover 25 cm to 30 cm wide and n.exc 60 cm long each laid dry abutting with each other with maximum gap between adjacent slabs n.exc 10 mm complete all as specified & directed by Engineer-in-Charge.
S & F in repair of Low density poly ethylene pipes (LDPE) 40mm dia for cable protection complete all as specified & directed by Engineer-in-Charge.
S & F in repair of Low density poly ethylene pipes (LDPE) 50mm dia for cable protection complete all as specified & directed by Engineer-in-Charge.
S&F in repair Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A, PF, kW, kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability complete all as specified & directed by Engineer-in-Charge.
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified & directed by Engineer-in-Charge.
S&F steel water tubing 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
M&L for painting the old existing LT panel board /feeder pillars of size 1400x1200x450mm including scraping and removing the old painted surfaces and painting /matching the same colour paint including two coats of super enameled paint (Gray paint) and without distrubing the existing electric system and removing grass and bushes including its roots growing around the panel complete all as specified & directed by Engineer-in-charge.
M&L for painting the old existing LT panel board /feeder pillars of size 1200x1050x450mm including scraping and removing the old painted surfaces and painting /matching the same colour paint including two coats of super enameled paint (Gray paint) and without distrubing the existing electric system and removing grass and bushes including its roots growing around the panel complete all as specified & directed by Engineer-in-charge.
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shap, supply, fixing and febrication CRCA sheet upto 3.15mm thick in existing, shape and size with and including all jointing material such as hinges, nuts, bolts or washer and welding etc complete all as specified & directed by Engineer-in-Charge NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/wemin proof for installing incoming/outgoing MCCB/ Switch fuses/cable etc complete all as directed. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board. (iii) The replaced porting shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer. (iv) The rates quoted by the contractor deemed to be with and including dismantling/taking out/removing carefully, any damaed part/portion of the feeder pillar box/panel board as directed.
M&L for cement concrete (1:3:6) type C-2 (using 40mm grade stone aggregate) around the LT Panels/Feeder pillar box /pole structure etc complete all as specified & directed by Engineer-in-charge. Note: PCC (1:3:6) work in around the pole structure min 100mm thickness after cleaning the surface area.
S&F aluminium lugs suitable for 16 Sqmm 4 core complete all as specified & directed by Engineer-in-charge.
S&F aluminium lugs suitable for 25 Sqmm 4 core complete all as specified & directed by Engineer-in-charge.
S&F aluminium lugs suitable for 35 Sqmm 4 core complete all as specified & directed by Engineer-in-charge.
S&F aluminium lugs suitable for 50 Sqmm 3.5 core complete all as specified & directed by Engineer-in-charge.
S&F aluminium lugs suitable for 70 Sqmm 3.5 core complete all as specified & directed by Engineer-in-charge.
S&F aluminium lugs suitable for 95 Sqmm 3.5 core complete all as specified & directed by Engineer-in-charge.
S&F aluminium lugs suitable for 120 Sqmm 3.5 core complete all as specified & directed by Engineer-in-charge.
S&F aluminium lugs suitable for 150 Sqmm 3.5 core complete all as specified & directed by Engineer-in-charge.
S&F aluminium lugs suitable for 185 Sqmm 3.5 core complete all as specified & directed by Engineer-in-charge.
S&F electronic spices assorted Polyolefin heat shrink tube of size 25mm for LT UG Cable insulation of size 16 sqmm to 35 Sqmm with colour code (R,Y & B) complete all as specified & directed by Engineer-in-charge.
S&F electronic spices assorted Polyolefin heat shrink tube of size 50mm for LT UG Cable insulation of size 50 sqmm to 120 Sqmm with colour code (R,Y & B) complete all as specified & directed by Engineer-in-charge.
M/S AUTOMATION AND SWITCHGEAR CONTROL (BID ID -3212052)
SHREE BHAGWATI ENTERPRISES (BID ID -3212240)
shivam electricals and engneers (BID ID -3207778)
GITANSH ENGINEERS AND COMPANY (BID ID -3217615)
Rasam Engg Co. (BID ID -3210132)
M/s Shree Construction Company (BID ID -3211565)
star electricals (BID ID -3218222)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .