| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹32.3 L+₹1.2 L (3.82%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹36.3 L+₹5.2 L (16.7%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹37.4 L+₹6.3 L (20.2%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹38.7 L+₹7.5 L (24.2%)Rejected-Finance | L5 | Rejected-Finance High Rate |
| Sl No | Description | Qty | Unit | Tejas Enterprises L4 | Star Electrical L5 | Sneha Aircool L3 | Sparkh Electricals & Works L10 | Monarch Sales Corporation L8 | SONU ENTERPRISES L11 | R. P. Suppliers and Construction Co. L9 | KESARI AND SONS L7 | ECOBUILD L1 | DARSHAN ENTERPRISES L6 | Mepcon Projects Pvt LTd L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out and Relaying / Rerouting of serviceable XLPE LT UG cable of following sizes including disconnection from LT Panel/Pole/FP etc and reconnection after re-laying work to LT Panel/Feeder Pillar /MDB according to existing system with suitable size of AL Lugs, nut-bolts & washers etc and fixed on any type of wall with suitable size of GI saddles etc complete of size 3.5 Core 300 Sqmm complete all as specified and as directed.
Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A. | 60 | RM | 36 ₹2,160 | 9 ₹540 | 30 ₹1,800 | 105 ₹6,300 | 85 ₹5,100 | 50 ₹3,000 | 75 ₹4,500 | 40 ₹2,400 | 5 ₹300 Lowest | 90 ₹5,400 | 15 ₹900 |
| 2.00 | Ditto all as per item No 1 above but 3.5 Core 240 Sqmm | 80 | RM | 36 ₹2,880 | 8 ₹640 | 30 ₹2,400 | 80 ₹6,400 | 80 ₹6,400 | 80 ₹6,400 | 75 ₹6,000 | 35 ₹2,800 | 5 ₹400 Lowest | 90 ₹7,200 | 15 ₹1,200 |
| 3.00 | Ditto all as per item No 1 above but 3.5 Core 185 Sqmm | 50 | RM | 36 ₹1,800 | 7 ₹350 | 30 ₹1,500 | 60 ₹3,000 | 80 ₹4,000 | 70 ₹3,500 | 75 ₹3,750 | 35 ₹1,750 | 5 ₹250 Lowest | 90 ₹4,500 | 15 ₹750 |
| 4.00 | Ditto all as per item No 1 above but 3.5 Core 150 Sqmm | 60 | RM | 36 ₹2,160 | 6 ₹360 | 30 ₹1,800 | 50 ₹3,000 | 80 ₹4,800 | 60 ₹3,600 | 60 ₹3,600 | 35 ₹2,100 | 5 ₹300 Lowest | 90 ₹5,400 | 15 ₹900 |
| 5.00 | Ditto all as per item No 1 above but 3.5 Core 120 Sqmm | 90 | RM | 36 ₹3,240 | 5 ₹450 Lowest | 30 ₹2,700 | 50 ₹4,500 | 65 ₹5,850 | 58 ₹5,220 | 60 ₹5,400 | 25 ₹2,250 | 5 ₹450 Lowest | 75 ₹6,750 | 15 ₹1,350 |
| 6.00 | Ditto all as per item No 1 above but 3.5 Core 95 Sqmm | 80 | RM | 36 ₹2,880 | 4 ₹320 Lowest | 30 ₹2,400 | 45 ₹3,600 | 65 ₹5,200 | 55 ₹4,400 | 60 ₹4,800 | 25 ₹2,000 | 5 ₹400 | 75 ₹6,000 | 15 ₹1,200 |
| 7.00 | Ditto all as per item No 1 above but 3.5 Core 70 Sqmm | 90 | RM | 36 ₹3,240 | 4 ₹360 Lowest | 30 ₹2,700 | 45 ₹4,050 | 65 ₹5,850 | 52 ₹4,680 | 45 ₹4,050 | 25 ₹2,250 | 5 ₹450 | 75 ₹6,750 | 12 ₹1,080 |
| 8.00 | Ditto all as per item No 1 above but 3.5 Core 50 Sqmm | 120 | RM | 36 ₹4,320 | 4 ₹480 Lowest | 24 ₹2,880 | 25 ₹3,000 | 65 ₹7,800 | 50 ₹6,000 | 45 ₹5,400 | 25 ₹3,000 | 5 ₹600 | 75 ₹9,000 | 12 ₹1,440 |
| 9.00 | Ditto all as per item No 1 above but 3.5 Core 35 Sqmm | 110 | RM | 36 ₹3,960 | 4 ₹440 Lowest | 24 ₹2,640 | 25 ₹2,750 | 50 ₹5,500 | 48 ₹5,280 | 45 ₹4,950 | 20 ₹2,200 | 5 ₹550 | 60 ₹6,600 | 10 ₹1,100 |
| 10.00 | Ditto all as per item No 1 above but 3.5 Core 25 Sqmm | 150 | RM | 36 ₹5,400 | 4 ₹600 Lowest | 21 ₹3,150 | 25 ₹3,750 | 70 ₹10,500 | 45 ₹6,750 | 30 ₹4,500 | 20 ₹3,000 | 5 ₹750 | 60 ₹9,000 | 10 ₹1,500 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
5 Aug 2025, 6:00 pmClosed
GE Khadakwasla
GE Khadakwasla
REPAIR / REPLACEMENT OF ELECTRICAL OVERHEAD LINES AND LT UG CABLES IN ZONE C, PERIFERALS AREA AND CONNECTED WORKS AT NDA KHADAKWASLA
2025_MES_720938_1
8969/E8
Open Tender
Civil Works
Item Rate
180 days
GE Khadakwasla
As per Tender documents
9 documents required · 9 mandatory
₹500
GE Khadakwasla
₹84,000
Yes
30 Sept 2025
17 Jul 2025
7 Aug 2025
17 Jul 2025
5 Aug 2025
31 Jul 2025
17 Jul 2025 - 31 Jul 2025
Amount
Taking out and Relaying / Rerouting of serviceable XLPE LT UG cable of following sizes including disconnection from LT Panel/Pole/FP etc and reconnection after re-laying work to LT Panel/Feeder Pillar /MDB according to existing system with suitable size of AL Lugs, nut-bolts & washers etc and fixed on any type of wall with suitable size of GI saddles etc complete of size 3.5 Core 300 Sqmm complete all as specified and as directed. Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A.
Ditto all as per item No 1 above but 3.5 Core 240 Sqmm
Ditto all as per item No 1 above but 3.5 Core 185 Sqmm
Ditto all as per item No 1 above but 3.5 Core 150 Sqmm
Ditto all as per item No 1 above but 3.5 Core 120 Sqmm
Ditto all as per item No 1 above but 3.5 Core 95 Sqmm
Ditto all as per item No 1 above but 3.5 Core 70 Sqmm
Ditto all as per item No 1 above but 3.5 Core 50 Sqmm
Ditto all as per item No 1 above but 3.5 Core 35 Sqmm
Ditto all as per item No 1 above but 3.5 Core 25 Sqmm
Ditto all as per item No 1 above but 4 Core 16 Sqmm
Supply and laying in replacement including testing and commissioning of LT UG Cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip armoured with multi stranded aluminum conductor, ISI marked, heavy duty including disconnection from LT Panel/Fedder Pillar/Pole etc and reconnection after laying work to same LT Panel/Feeder Pillar /Pole according to existing system with suitable size of AL Lugs, nut-bolts & washers etc including cables laid in trenches/ducts/under plinth floors/ passing through pipes etc or fixed on any type of wall with suitable size of GI saddles etc complete of size 3.5 Core 300 Sqmm complete all as specified and as directed. Note - Excavation / earthwork, cable protection pipe & sand cushioning will be measured and paid separately under respective item of sch A.
Ditto all as per item No 12 above but 3.5 Core 240 Sqmm
Ditto all as per item No 12 above but3.5 Core 185 Sqmm
Ditto all as per item No 12 above but 3.5 Core 150 Sqmm
Ditto all as per item No 12 above but 3.5 Core 120 Sqmm
Ditto all as per item No 12 above but 3.5 Core 95 Sqmm
Ditto all as per item No 12 above but 3.5 Core 70 Sqmm
Ditto all as per item No 12 above but 3.5 Core 50 Sqmm
Ditto all as per item No 12 above but 3.5 Core 35 Sqmm
Ditto all as per item No 12 above but 3.5 Core 25 Sqmm
Ditto all as per item No 12 above but 4 Core 16 Sqmm
Ditto all as per item No 12 above but 4 Core 10 Sqmm
Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out for foundation of pole, stay, laying of cable and pipe etc as in Hard/Dense soil complete all as specified and as directed.
Ditto all as per item No 24 above but Soft / Disintegrated Rock
Returning and filling, including spreading levelling and well ramming in layers n exc 25 cm complete all as specified and as directed.
Removing excavated material a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed.
M&L for dry crush sand cushioning to under ground cable in trenches incl spreading, leveling and hand punning complete all as specified and directed. Note : For measurement purpose, punned thickness shall be considered.
Supply and laying in replacement of burnt clay fly ash building bricks, designation 75 (Kg/Sqcm), laid in right angle along the cable for protection of cable, complete all as specified and directed.
S&F in replacement of GI pipe Light grade 50 mm dia ISI marked with all fittings laid in trenches and fixed pole by flat iron clamps, nut,bolt,washers suitable size complete required for protection/ support of under ground cable complete all as specified and as directed.
Supply and laying 40 x 32 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propagating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 10 to 16 Sqmm 3.5 core complete all as specified and directed
Supply and laying 50 x 38 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propagating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 25 to 35 sqmm 3.5 core complete all as specified and directed
Supply and laying 63 x 50 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propagating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 50 Sqmm 3.5 core complete all as specified and directed
Supply and laying 77 x 63 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propagating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 70 Sqmm 3.5 core complete all as specified and directed
Supply and laying 90 x 75 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propagating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 95 Sqmm 3.5 core complete all as specified and directed
Supply and laying 110 x 95 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propagating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 120 to 150 Sqmm 3.5 core complete all as specified and directed
Supply and laying 120 x 103 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propagating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 185 to 240 Sqmm 3.5 core complete all as specified and directed
Supply and laying 160 x 135 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propagating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 300 to 400 Sqmm 3.5 core complete all as specified and directed
Supply and laying in replacement G.I pipe light grade pipe 100 mm dia with all fittings required for protection of under ground cable complete all as specified and as directed.
M&L for road cutting through existing bituminous road as required for laying pipe/cable etc and make good with and including earthwork and necessary excavation, complete material required to match with the existing one or with PCC (1:2:4) type B1 and bitumen complete all as specified and as directed
M & L for Straight Through Jointing Kit Heat Shrink type suitable for 1.1 KV LT XLPE armoured aluminium stranded conductor Cable Outdoor type complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of jointing work complete all as specified and directed of following sizes :- 3.5 Core 300 Sqmm
Ditto all as per item No 41 above but 3.5 Core 240 Sqmm
Ditto all as per item No 41 above but 3.5 Core 185 Sqmm
Ditto all as per item No 41 above but 3.5 Core 150 Sqmm
Ditto all as per item No 41 above but 3.5 Core 120 Sqmm
Ditto all as per item No 41 above but 3.5 Core 95 Sqmm
Ditto all as per item No 41 above but 3.5 Core 70 Sqmm
Ditto all as per item No 41 above but 3.5 Core 50 Sqmm
Ditto all as per item No 41 above but 3.5 Core 35 Sqmm
Ditto all as per item No 41 above but 3.5 Core 25 Sqmm
Ditto all as per item No 41 above but 4 Core 16 Sqmm
Ditto all as per item No 41 above but 4 Core 10 Sqmm
S & F in replacement of MCB, 4P, 415 V, 63 Amp, 10 kA, C-Curve, suitable to fit existing sheet metal enclosure/Sub MDB complete all as specified and as directed..
M&L for PCC / Interlocking Tiles Path Way cutting of size (45x45) cm as required for laying pipe/cable etc and making good with and including earthwork and necessary excavation, complete material required to match with the existing one or with PCC 1:2:4 type B1 complete all as specified and as directed
M & L for Fixing of LT UG Cable on wall/ under duct with suitable size of saddles, screws and connected accessories complete all as specified and as directed.
Supply & Fix in replacement of including commissioning and installation of digital automatic timer switch distribution panel board, factory assembled in powder coated steel sheet enclosure, comprising of 4P MCB, 40 Amps & 3 Pole power contactor 40/50 Amps and 230V digital time switch for controlling LED street lights, including earth work for fixing Timer switch distribution panel board and shall be provided 4 Nos 20x20x3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth complete all as specified and as directed.
M&L for PCC (1:3:6) type C1 (Using 20mm graded coarse aggregate) for coping of poles including fair finishing the exposed surfaces even and smooth without using extra cement including necessary formwork complete all as specified and as directed.
M & L for demolition of unreinforced PCC, floors, foundation etc in any position and any description including removal of demolished material complete all as specified and directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium 10 Sqmm stranded conductor, Twin core cable flat served with inner sheathing of PVC tape and overall PVC sheathed in service connections including taking down existing one complete all as specified and directed.
Supply & Fix in replacement of SMC Junction box on pole/ wall, dimensions (270 x 225 x 135)mm (LxBxD), 3 phase 4 wire system, including cable connecting base, with mounting SS railing, Cable lugs suitable to 35 Sqmm 3.5 core cable, connection for incoming and outgoing cables including Fixing arrangement on wall/ pole etc complete all as specified and directed
M&L for LT UG Cable fault finding/testing from FP Box to fault location including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB/Transformer etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of fault finding/testing work complete all as specified and directed of size 3.5 Core 300 to 400 Sqmm. Note:- Job will be measured after fault detection of any type regarding this decision of shall be final & binding.
Ditto all as per item No 61 above but 3.5 Core 120 to 240 Sqmm
Ditto all as per item No 61 above but 3.5 Core 35 to 95 Sqmm
Ditto all as per item No 61 above but 3.5/4 Core 6 to 25 Sqmm
Labour for disconnecting the LT UG Cable (approx 10-12 No of Cables) of any size from LT ACB breaker and setting aside at safe place/side by taking proper shut down for human safety, cleaning the duct/trench by removing foreign material/mud from trench/duct including reconnecting the all LT UG Cables according to existing system complete all as specified and directed
M & L in replacement for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones of Post Office RED Colour and fixed on LT Poles with M.S. clamps, bolts and nuts of required size, for 440 Volts LT of size 200 X 150mm complete including taking down existing onecomplete all as specified and as directed.
M & L for route tracing of LT UG cables under ground/road from one end to another end of cable, size upto 300 sqmm including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB/Transformer etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of route tracing work complete all as specified and as directed.
Supply & Fix in replacement of Cable Route Marker made up of Cast Iron of dia 80 mm and thickness 4.65 mm with supporting angle iron of size 20 x 20 x 3 mm and height 0.6 mtr for stand including priming, painting and writing of "LT UG CABLE" in suitable size of letter including necessary earthwork and grouted at suitable depth in PCC 1:3:6 Type C2 using 40 mm graded aggregate in mass concrete complete all as specified and as directed.
M & L in replacement of earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to LT Poles /DBs etc. as required including necessary excavation and earth work, concrete pit chamber, cover of PCC 1:2:4 type B1 including lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed including testing on completion.
S & F in replacement of LT Jumper with the help of Aluminium Conductor Steel Reinforcement. The length of jumper shall not be less than 2 meter including connection with the help of connector and aluminium lugs, nut bolt washers etc on the LT Pole complete all as specified and as directed.
Pruning / trimming of branches of trees interfering or overhanging on electrical overhead lines in such a way to have a clearance of not be less than 2 mtrs all around the outermost conductor of the span complete all as specified and directed. Note: Span shall be measured pole to pole as One Span
S & F in replacement pin type porcelain vitreous white brown or green insulator of size 100 mm height, 65 mm dia suitable for 1100 volts grade including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut including taking down existing one complete all as specified and as directed.
S & F in replacement Shackle type porcelain vitreous white brown or green insulator of size 100 mm height, 115 mm dia suitable for 1100 volts grade including two galvanised mild steel straps, washers, insulators bolts and nut etc including taking down existing one complete all as specified and as directed.
M&L in replacement aluminium conductor steel reinforced fixing on the over head LT pole with the help of aluminium tapes/ binding wire including taking down existing one complete all as specified as directed
M&L in replacement stay assembly complete with accessories as shown in electrical plate no 1 including loop type insulator, stay clamps, stay strands, excavation work of any type of soil strata and PCC work and taking down existing one complete all as specified and directed
M&L in replacement steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts & screws as specified type 410 SP-31 (9 mtrs long) as Pole/Strut including dismantling old/US steel struts, complete all as specified and directed.
M&L for plain concrete cement (1:3:6) type C2 (Using 40mm graded coarse aggregate) for foundation, filling and mass concrete of poles including necessary form work complete all as specified and as directed.
M&L for preparation of existing surface of steel tubular pole by scrapping down peeled off old paint, cleaning etc of length 8.5/9/11 mtrs and cross arms etc and applying one coat of aluminium coat paint including rewriting pole Nos as directed with black paint complete all as specified and directed
S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of 2 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars electrolytic grade of 400 Amps current rating including required size of nut bolts for fixing of cables upto 240 Sqmm. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts, washers and AL Lugs etc. The panel shall be provided with 04 Nos 50mmx50mmx5mm thick angle iron supports of not less than each 0.9 mtr height duly painted with anti corrosive black paint including earth work and grouted in PCC 1:3:6 at suitable depth as per site requirement including taking down existing one. The overall size of the Busbar panel shall not be less than 500mmx300mmx700mm (LxWxH) including 4 Nos cable entry holes suitable for cable entry up 3.5C 240 Sqmm at bottom complete all as specified and directed
M & L in replacement of GI Earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized iron strip 25 x 4 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to machinery/equipment for LT Panel, Feeder Pillars, Sub Feeder Pillars etc. as required including necessary excavation and earth work, concrete pit, chamber and pit cover in PCC 1:2:4 type B1 including lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh etc. complete all as specified and directed including testing on completion.
S&F in replacement Sheet Metal Enclosures factory made Tripple Pole and Earth enclosure with a three pin and earth plug with 63 Amp Industrial socket complete with one Four Pole MCB of 63 Amp, 415 Volts, 10 KA including wall mounting accessories and connection to Boiler complete all as specified and as directed.
S & F in replacement of GI strip 25 x 4 mm earth as earth continuity conductor or main earthing lead fixed to wall batten or recess or chases or buried in ground or fixed to poles or any other indicated situation etc.complete all as specified and as directed.
S & Fix in replacement PVC spiral spacer for LT overhead line of grey colour suitable for 3 phase 4 wire system, length of the spacer should not be less than 1200mm including taking down existing one and all arrangements shall be adopted by contractor for the same complete all as specified and directed. Note : Necessary ladder & scaffolding etc if required for this job is the responsibility of the contractor and rates included in this job.
Mepcon Projects Pvt LTd (BID ID -3383484)
Sneha Aircool (BID ID -3382257)
Tejas Enterprises (BID ID -3382189)
Star Electrical (BID ID -3382228)
DARSHAN ENTERPRISES (BID ID -3383777)
KESARI AND SONS (BID ID -3383528)
Monarch Sales Corporation (BID ID -3383164)
R. P. Suppliers and Construction Co. (BID ID -3383483)
Sparkh Electricals & Works (BID ID -3383046)
SONU ENTERPRISES (BID ID -3383391)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .