Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹8.9 L+₹42,244 (4.98%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹9.8 L+₹1.4 L (16.2%)Accepted-Finance | L3 | Accepted-Finance L3 |
Tender Value
₹9.2 L
EMD Value
₹18,440
Closing Date
21 Jun 2022, 6:00 pmClosed
Executive Engineer Electric Div Reasi
hall 301, block II, DC complex Reasi
Business unit near IRP chowk in District Reasi JK on turnkey basis
2022_PDD_173683_1
e NIT 08 of 2022-23 dt 10.06.22
Open Tender
Electrical Works
Turn-key
15 days
in jurisdiction of Electric Division Reasi
As per tender documents
2 documents required · 2 mandatory
₹1,000
Office of Executive Engineer Electric Div Reasi
₹18,440
Office of Executive Engineer Electric Div Reasi
24 Jun 2022
11 Jun 2022
22 Jun 2022
11 Jun 2022
21 Jun 2022
11 Jun 2022
11 Jun 2022 - 16 Jun 2022
16 Jun 2022
Laying of 11KV Line at two locations
ST Pole 9 mtr ST 410 SP33
35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE(11 kV, 3C +Earth
Heat Shrinkable Outdoor Cable Termination Kit
Suspension/Tension Clamp with eye hook
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type
Galvanised Nuts & Bolts
Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/Pole
Anti-Climbing Device with Clamps
Danger Plates with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip (25x3)mm
Red Oxide
Aluminium Paint
Supply, Fabrication,Erection, Testing and commissioning of 25KVA Distribution substation at JK bank, Bhagga, Reasi
11/0.433KV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) and with LV cable box having detachable Aluminium Gland plate
9 mtr long Pole ST-410, SP33
Gapless Surge Arrestor, 9kV, 10kA, LA with polymer housing, Station type
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type
11kV Horn Gap Fuse set 3-phase, 200 Amp
95sqmm cable 1.1kv grade, PVC insulated stranded conductor FRLS type
Al. Thimble 95mm2
11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of different sizes including clamps
Galvanised Nuts & Bolts
Earthing of substation - Excavation of earthing pit of dia 650mm & depth 3000mm, installation ofEarthing pipe of 40mm nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm x 3mm for connection of transformer body, GO set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
LT distribution box for 25KVA DTR with MCCB for incomer & SFU's for outgoing circuits
Prodigy Meter
Danger Plates with clamps
G.I Barbed Wire for anti climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum/Pole
Painting of Poles Red oxide
Painting of Poles Aluminium Paint
Supply, Fabrication,Erection, Testing and commissioning of 63KVA substation at J&K bank near IRP chwk, Reasi
11/0.433KV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) and with LV cable box having detachable Aluminium Gland plate
9 mtr long Pole ST-410, SP33
30 Sq mm ACSR Weasel Conductor
Gapless Surge Arrestor, 9kV, 10kA, LA with polymer housing, Station type
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type
11kV Horn Gap Fuse set 3-phase, 200 Amp
185sqmm cable 1.1kv grade, PVC insulated stranded conductor FRLS type
11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
GI Channel/Angle/Flat of different sizes including clamps
Galvanised Nuts & Bolts
Earthing of substation - Excavation of earthing pit of dia 650mm & depth 3000mm, installation ofEarthing pipe of 40mm nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm x 3mm for connection of transformer body, GO set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover
LT distribution box for 63KVA DTR with MCCB for incomer & SFU's for outgoing circuits
Wedge connection/PG Clamps
Danger Plates with clamps
G.I Barbed Wire for anti climbing
Prodigy Meter
Cement bottoming 1:2:4 mix as per REC standards .5cum/Pole
Painting of Poles Red oxide
Painting of Poles Aluminium Paint
Al. Thimble 185mm2
Naresh Kumar Kesar
Jeet Kumar
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .