Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.8 CrAccepted-AOC | ₹1.8 Cr Quoted ₹1.9 Cr | 1 | Accepted-AOC LOWEST |
| 2 | 2₹1.9 Cr+₹8.1 L (4.37%)Rejected-Finance OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | ₹1.9 Cr+₹8.1 L (4.37%) | 2 | Rejected-Finance NOT LOWEST |
| 3 | 3₹2.0 Cr+₹10.1 L (5.41%)Rejected-Finance | ₹2.0 Cr+₹10.1 L (5.41%) | 3 | Rejected-Finance NOT LOWEST |
| 4 | 4₹2.1 Cr+₹27.4 L (14.7%)Rejected-Finance | ₹2.1 Cr+₹27.4 L (14.7%) | 4 | Rejected-Finance NOT LOWEST |
| 5 | 5₹2.3 Cr+₹42.2 L (22.6%)Rejected-Finance | ₹2.3 Cr+₹42.2 L (22.6%) | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹2.3 Cr
EMD Value
₹3 L
Closing Date
16 Mar 2023, 6:00 pmClosed
CWE (AF) Gwalior
CWE (AF) Gwalior, AF STATION GWALIOR - 474020
ADDN/ALTN/IMPROVEMENT TO LIVING-IN ACCN OF SNCOS AND BELOW AT AF STN GWALIOR
2023_MES_574943_1
85046/E8
Open Tender
Civil Works
Item Rate
540 days
AF STATION GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,000
Garrison Engineer (AF) ADM Area Gwalior
₹3 L
Yes
26 Apr 2023
13 Jan 2023
23 Mar 2023
13 Jan 2023
16 Mar 2023
25 Feb 2023
Amount
Strucking off existing PCC floor surface 5 to 10 mm deep, picking, sweeping, cleaning and washing down with water to remove dust to receive cement mortar for tiling/kota stone, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick or stone masonry, etc. including raking out joints, hacking for key and scrubbing down with water, etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any mix / grade in ground floor and pavings not exceeding 15cm thickness (below or above ground level) including removal of debris out off the AF station premises / MOD land, etc complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) of any mix / grade, any description and in any position as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including removal of debris out off the AF station premises / MOD land etc complete all as specified and directed .
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Material and Labour for rendering 15 mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surface, finished even and smooth without using extra cement complete all as specified and directed.
Material and Labour for rendering 15 mm thick in cement mortar (1:4) on fair faces of brickwork / external surface of masonry wall using liquid water proofing compound mixed at 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. (Note: WPC will be measured and paid separately under respective item of BOQ )
Material and Labour for rendering 5 mm thick in cement mortar (1:3) on concrete surface of ceiling finished even and smooth without using extra cement complete all as specified and directed.
Supply only water proofing compound of approved make all as specified and directed.
Material and Labour glazed colour ceramic digitally designed coloured tiles 450 x 300 x 7mm thick coloured wall highlighter on vertical surfaces such as skirting dados, etc., set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles including fixing with neat cement based approved chemical adhesive required for tiling as backing coat complete all as specified and as directed. Note : Material of adhesive will be supplied and measured separately.
M&L for non skid rectified edges (joint free) digitally designed coloured ceramic floor tiles not less than 7-8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over & including 15 mm thick screed bedding CM 1:4 complete all as specified & directed.
Supply only smart care normal tile adhesive for wall with technical specifications appended as below :- 1- Coverage 2-2.50 sqft/kg for a bed of 3 mm thick 2- kind of tiles that can be laid -ceramic/glazed tiles 3-Curing Time - 24 hour
Material and Labour for Granite (of any type) work, 20 mm thick (Table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms in CM 1:4 and including pointing in white cement 1:2, using marble dust with admixture of pigment to match with shade of Granite including half moulding of granite edges including screed bed 20mm thick in CM 1:6 complete all as specified and directed.
Material and Labour for 16 mm to 18 mm thick Baroda green marble slab of approved type / variety (table rubbed and pre mirror polished) in window cill, jambs, steps, and cooking platforms IN cm 1:4 including pointing in coloured cement to match with shade of Baroda green marble slab including half moulding of Baroda green marble slab edges over and including 20 mm thick screed bed in CM 1:6 for laying of Baroda green marble slab etc complete all as specified and as directed.
Material and Labour for machine cut Kota stone slab 20 to 25mm mm thick in treads, landings of staircase over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including and grinding polishing half moulding of kota stone nosing, over and including screed bed 20mm thick in CM 1:6 etc complete all as specified and as directed.
Material and Labour for machine cut Kota stone slab 20 to 25 mm thick as in skirting, risers, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mirror polish granite finish including backing coat 10 mm thick in CM 1:3 complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware etc complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each etc. including builders hardware etc. complete all as specified and directed .
Supply and fix pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
Supply and fix pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
S & F Flush shutters 30mm thick, solid core construction, with block board core and plywood face panels commercial type on both side and both faces covered with approved pattern with decorative coloured laminate type 1 of 0.9 mm thick and all around side faces covered with 10mm thick 1st class hard wood lipping duly polished complete all as specified and directed.
S & F 2nd class hard wood 35mm thick gauzed and skeleton shutters (Three panels), factory made open rebated and prepare to receive glass, gauge etc (with sash bar), edges of framing plain, chamfered or rounded , fitted with cut & mitred beads for securing glass etc. Size of members of shutter shall be as specified in SSR 2009 Part-I, section 8. Member shall be kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as specified and directed.
M & L for solid PVC door frame of size 50 mm X 47 mm with a thickness of 5 mm , made out of extruded 5 mm thick PVC Sheet of density 600 kg/cum having pattern, width of 50 mm and thickness of 10 mm providing weather sea/Non-woven self adhesive gasket throughout the frame. All three frame lengths reinforced with 19 mm x 19 mm MS Square tube of 19 gauge, mitred cut at two corners and joined with 2 nos of 150 mm long brackets of 15 mm x15 mm MS square tube. The door frame shall be fixed to the wall using 8mm dia/100mm long MS screws through the frame by using PVC fasteners. A minimum of 4 nos of screws to be provided for each vertical member & minimum 2 nos for horizontal members etc complete as per manufactures specification and directed by Engineer -in -Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick solid panel PVC(style) consisting of frame made out of M.S tubes 19 gauge thickness and size 19mm x19 mm for stiles and 15mmx15mm for the top and bottom rails MS frame shall have a coat of metal primer of approved make. MS frame shall be covered with heat moulded (100% LEAD FREE) PLAIN PVC 'C' channel made from 5mm thick sheet of density 600kg/cum of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles and 5 mm thick 95 mm wide PLAIN PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 angle on inner side to form top and bottom and lock rail and 115mm wide PLAIN PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both side to form lock rail Top bottom and lock rail shall be provided either side. An additional 5m thick shall be provided on either side of the panel. An additional 5mm thick PVC strip of 20mm width is to be stuck on the bottom side of the C channel. Paneling of 5mm thick PLAIN PVC sheet to be fitted inside the MS frame welded /seated to the styles and rails with 5mm x 30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc 10mm thick ,20 mm wide cross PVC sheet as gap insert for the top rail & bottom rail. Door to be fixed to frames with 3 nos. MS powder coated butt hinges of size 100mm x25mm x2mm using 32mm long steel screws drilled suitable to pass through both the walls of the MS tube other hardwares should be fixed with 19mmx6mm size steel screws complete as per manufactures specification and directed by Engineer – in – Charge.
Supply and fix stainless steel hinges medium weight butt hinges of 100 mm size complete all as specified and directed.
S &F Stainless steel handle medium weight of 100mm size complete all as directed and specified
Supply and fix Stainless steel handle medium weight of 150 mm size complete all as directed and specified.
Supply and fix Stainless steel barrel tower bolts medium weight of of extruded section, 150mm long complete all as specified and directed.
S&F Stainless steel sliding door bolts 250mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed.
Supply and fix mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
Supply and fix floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150mm complete all as specified and directed.
S&F powder coated (of approved tint) aluminum frame & openable shutter for door, window, ventilators including joining cleat glazing clip, snap beading, rubber packing, building hardware & screw etc for fixing complete all as specified & directed. Note : (i) wire mesh and sheet glass shall be measured and paid separately under respective items. (ii) Weight of only aluminium section used for fabrication of door/window shall be measured for payment)
Supply and fix stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples etc complete all as specified and directed.
Supply and fix 4.0 mm thick sheet glass, ordinary quality and glazing with oil putty in square/ rectangular, not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply and fix 4.0 mm thick figured glass pin headed type in squares/ rectangular and glazing with oil putty, not exceeding 0.5 Sqm in each pane complete etc complete all as specified and directed.
Supply and fixing of rubber beading door seal 40x 5mm strip in bottom of door complete all as specified and directed.
S&F 18mm/19 thick PVC board of grade 1 quality, one side pre laminated color fixed with screws, solvent cement/ adhesive to make kitchen cabinet and cupboard shutter complete all as specified and directed
Supply and fix continuous (piano) hinges, mild steel, bright finish or electro galvanised, 30mm wide flaps when opened complete all as specified and directed.
Supply and fix Stainless steel decorative handle medium weight of 100mm with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified .
Supply and fix Aluminum power coated tower bolts 100mm long and fixed complete all as specified and directed.
Material and Labour for plain cement concrete (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) as in copping on chajja, balcony or in roof Kerbs, benching, coping, bed plates for fixing holdfast, bed block, kerb stone in sides of interlocking tiles, rounded or chamfered on edges and similar work including necessary formwork complete all as specified and directed.
Dismantling existing roof treatment including tarfelt / cement plaster, etc from roof surfaces including cleaning the surface and removing the debris from site out of MoD land complete all as specified and directed.
M&L for PCC type 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in roof kerbs or mud stops, including finishing the surface even and smooth without using extra cement to receive the acrylic based water proofing material, rounded or chamfered on edges etc complete all as specified and directed. (Note : WPC shall be measured and paid separately under respective items).
M & L for Single component, weather resistant, liquid applied acrylic polymer based elastomeric water proof coating using elastomeric water proofing membrance for all types of exposed roof slabs (new and old), terraces (sloped and flat) water proof coating shall be UV rays resistant, solar reflective, etc complete all as specified in particular specifications.
Material and Labour for PCC (1:5:10) type E-2 (using 40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Demolition of brickwork built in cement mortar of any description complete all as specified and directed.
Material and Labour for brickwork using old size sub class 'B' brick, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed
Material and Labour for 75 mm thick PCC 1:3:6 type C-2 (using 40mm graded stone agg) as in plinth protection, finished even and smooth using extra cement complete all as specified and directed.
Material and Labour for providing and injecting chemical emulsion for Post Construction Anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 Litres per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.
Material and Labour for post construction anti-termite treatment of soil under existing floors using chemical emulsion @ one litre per hole , placed 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors etc complete all as specified and directed.
Supply and fix in repair fancy type decorated Stainless Steel curtain hanging rods 25mm dia, and fixed to stainless steel bracket for hanging curtain complete all as specified and directed.
Supply and fix Stainless Steel brackets having screw for tightening of curtain rod of 25mm dia for fixing of curtain rod, complete all as specified and directed.
Supply and fix Stainless Steel bright color decorative corner/end cap for Curtain rod complete all as specified and directed.
Supply and fix Chromium plated stainless steel peg set of six with base plate and fixed to wall/door with rawal pegs stainless steel screw complete all as specified and directed.
Supply and fix shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed .
Supply and fix in repair Brass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed.
Supply and fix in repair brass chromium plated shower roses with swivel joints, 125 mm size in square with CP long shank arm including fixing to steel pipe or union, complete all as specified and as directed.
Material and Labour in repair for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Material and Labour in repair for PVC(SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified directed.
Supply and fix in repairs WC squatting pan " Orissa Pattern" of size 580 X 440 mm white with integral foot rest including PVC P or S trap, front or back inlet and making connection to trap and to flushing cistern and including lime concrete bedding complete all as specified and directed.
Supply and fix in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding, flushing cistern and flush pipe) but including flush pipe and health faucet (ABS Body) mild CP suitable 15mm Dia pipe 1.25mtr long flexible tube and ABS wall hook incl connection to trap, etc. completed all specified and directed.
Supply and fix in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flush system valve float and handle, PVC flush pipe 32 mm bore and brackets complete set all as specified and directed.
Supply and fix PVC seat cover for WC pedestal complete set complete all as specified and directed.
Supply and fix in repair vitreous china wash hand basin white, flat back,whie Counter Top type size 550mm x 400mm excluding taps, chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe and brass chromium plated waste coupling of 32mm dia complete all as specified and directed.
Supply and fix in repair concealed stop cock fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end of size 15 mm bore complete all as specified and directed.
Supply and fix in repair concealed angle cock, fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both end of size 15 mm bore complete all as specified and directed.
S&F in repairs bib tap with flange, quarter turn with water saving nozzle screwed for iron pipe & fixed 15mm bore, complete all as specified and directed
S&F in repairs pillar taps cock with water saving nozzle 15mm bore pillar tapes quarter turn with or without lettered ‘HOT’ or ‘COLD’ screwed with iron pipe & fixed complete all as specified and directed
Supply and fix in repair PVC connections 15mm size with PTMT nuts of length 600 mm, complete all as specified and as directed.
Dismantling tanks water tank exc 250 but n exc 500 ltr. complete all as specified and directed.
Supply and fix rotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed type), triple layer construction hoisted and fixed in position including 20 mm bore GI medium grade over flow ( 450mm long) and washout pipe (600 mm long ) with fittings, etc complete all as specified and directed.
Supply and fix in repair ball/ float valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and as directed.
Taking up or down steel water tubing and connections of 15mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down steel water tubing and connections of 20mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
Refixing old 15 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors in new or old position complete all as specified and directed.
Refixing old 20 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors in new or old position complete all as specified and directed.
Supply and fix 15 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
Supply and fix 20 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
Dismantling of cast iron/PVC of 75 mm/100mm/110mm bore, jointed in cement mortar by taking out of trenches, if required, complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) Soil/waste and vent pipe in any length single socketed with rubber ring joints fixed to wall, laid under floor etc complete all as specified and directed
All as per item no.1.82 here-in-before but except pipe complete all as specified and directed .
Supply and fix 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
Supply and fix 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
Supply and fix 75 mm bore PVC (SWR) junction single T (equal or unequal) ordinary or spigot and socket type or with parallel branches as ‘T’ piece with access doors complete all as specified and directed.
Supply and fix PVC (SWR) bends 110mm bore (any radius) complete all as specified and directed
Supply and fix PVC (SWR) bends 75mm bore (any radius) complete all as specified and directed
Supply and fix 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
Supply and fix 110mm PVC (SWR). sanitary connection socket to fit WC outlet complete all as specified and directed.
Supply and fix 110mm PVC (SWR). sanitary connection S branch, with branch 370 to 450 mm long excluding joint complete all as specified and directed.
Supply and fix in repair stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roofs for 110 mm bore pipe etc complete all as specified and directed.
Supply and fix in repair stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roofs for 75 mm bore pipe etc complete all as specified and directed.
Material and Labour for Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed.
Demolition of reinforced cement concrete of roofs, floors (other than ground floor) beams, staircases, landing, chajjas and similar suspended works complete all as specified and directed.
Material and Labour for reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in chajjas/roof projection/RCC railing complete all as specified and directed. Note : Reinforcement and formwork will be measured and paid separately under respective item of BOQ.
Material and Labour reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, post and struts, etc. complete all as specified and directed. Note : Reinforcement and formwork will be measured and paid separately under respective item of BOQ.
Use and waste of formwork to sides of columns, pillars, piers, post and struts for rough finished surface of concrete flat complete all as specified and directed.
Material and Labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed.
Use and waste of formwork to chullah hoods, chajjas, trough and similar items including edges complete all as specified and directed.
Material and Labour for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts and confirming FE 290 Gde E165 complete all as specified and directed.
M & L for preparation of new surface of wall and applying 4 mm thick POP punning over it to give a smooth level finish, the final coat of punning to have one coat of acrylic water based interior grade primer over which apply two coats of oil bound distemper using airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 meter. The spray machine should be of reputed manufacturer, duly certified by the paint manufacturer, with pro guard technology and capability of tracking pressure and paint usage.The spray machine should have accessories for applying distemper in hard to reach areas and to penetrate the distemper on the surfaces completed all as specified & directed. Note: (a) The work shall be executed from authorized applicator through manufacturer of which the material i.e. paint, distemper, cement based paint, putty etc is proposed to be used by the contractor and approved by Garrison Engineer. (b) Colour of OBD/ Exterior Emulsion paint shall be approved by Garrison Engineer.
M&L for applying 4 mm thick POP punning over old putty prepared surface to give a smooth level finish , the final coat of punning to have one coat of acrylic water base interior grade primer over which apply two coats of oil bound distemper using airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 meter. The spray machine should be of reputed manufacturer, duly certified by the paint manufacturer, with pro guard technology and capability of tracking pressure and paint usage. The spray machine should have accessories for applying distemper in hard to reach areas and to penetrate the distemper on the surfaces completed all as specified & directed. Note: (a) The work shall be executed from authorized applicator through manufacturer of which the material i.e. paint, distemper, cement based paint, putty etc is proposed to be used by the contractor and approved by Garrison Engineer. (b) Colour of OBD/ Exterior Emulsion paint shall be approved by Garrison Engineer.
Material and Labour for preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint), complete all as specified and directed.
Material and Labour for preparation of new steel Surfaces of any description, over 10cm in width or girth, and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and Labour for preparation of new wooden Surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Supply and fix in repair Stop valves/Gate valves 25 mm dia cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fix Stop valves/Gate valves 25 mm dia cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Material and Labour for preparing old existing surface on ceiling surface and applying two coat of white wash after surface preparation complete all as specified and directed.
Material and Labour for preparing new plaster surfaces of ceiling and applying two coats of white wash over coat of primer complete all as specified and directed.
Material and Labour for PCC type B-0 1:2:4 (using 12.5mm aggregate ) as in floor complete all as specified and directed.
Material and Labour for preparing old existing surface on Walls surface and applying two coat of white wash complete all as specified and directed.
Material and Labour for preparing new plaster surfaces of Walls and applying two coats of white wash over coat of primer complete all as specified and directed.
Material and Labour in repair for stainless steel grating doom with hole or without hole 100/125 mm dia size complete all as specified and directed.
Supply and fix in repair 100mm PVC vent cowl complete all as specified and directed.
Supply and fix in repair vitreous china urinal, full stall urinal (back or corner wall type) complete including providing and fixing plug bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60mm brass screws pointing around urinal back in cement, including fixing CP water spreader with brackets, flush pipe, CP grating and union for discharge pipe, any accessories which are required to stall the urinal complete all as specified and directed. (Note:- Flush pipe and urinal spreader shall be measured and paid separately as supply only)
Supply and fix in repair Vitreous China urinal partitions, white of size 310x700mm terminating about 40cm above floor line or platform etc. complete all as specified and directed.
Supply only 32mm dia flush pipe of chromium plated brass tube, for urinal, etc. complete all as specified and directed.
Supply only Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) etc. complete all as specified and directed.
M &L for demolition of existing traps and removing the material and cleaning with the wire brush to dry and including applications of one coat of Sika latex SBR or Nito bond SBR (or equivalent from approved list of makes and as approved by GE) and cement in ratio 1:1 @400 gm/sqm. After drying apply two coats of SIKA top seal 107 or Brush bond @ 1.5 Kg/sqm (or equivalent from approved list of makes and as approved by GE) min 4 hrs gap is required between application of each coat and including 15mm thick rendering in CM 1:4, finished even and smooth without using extra cement as in sunken portion complete all as specified and directed.
M &L for hacking and racking out the wall joints with wire brush to dry and apply one coat of Sika latex SBR or Nito bond SBR (or equivalent from approved list of makes and as approved by GE) and cement in ratio 1:1 @400 gm/sqm. After drying apply two coats of SIKA top seal 107 or Brush bond @ 1.5 Kg/sqm (or equivalent from approved list of makes and as approved by GE) min 4 hrs gap is required between application of each coat and including 15mm thick rendering in CM 1:4, finished even and smooth without using extra cement as in sunken portion complete all as specified and directed.
M&L on old surfaces of wall for two coats of water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & colour stay technology, excellent dirt pick up resistance with low VOC less than 50Gram/Litre as per LEEDS specifications having anti algal properties in two coats @1.79 litre (Undiluted)/10 Sqm diluted with water as per manufacturers instructions applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Note : Subsequent coat of painting shall be done after allowed 6 to 8 hrs to dry the painted surface. Note: (a) The work shall be executed from authorized applicator of make approved by Garrison Engineer. (b) Colour of OBD/ Exterior Emulsion paint shall be approved by Garrison Engineer.
M&L on new wall surfaces for for two coats of water based premium acrylic smooth exterior of approved colour with silicon additive & colour stay technology, excellent dirt pick up resistance with low VOC less than 50Gram/Litre as per LEEDS specifications having anti algal properties in two coats @1.79 litre (Undiluted)/10 Sqm diluted with water as per manufacturers instructions applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Note : Subsequent coat of painting shall be done after allowed 6 to 8 hrs to dry the painted surface. Note: (a) The work shall be executed from authorized applicator of make approved by Garrison Engineer. (b) Colour of OBD/ Exterior Emulsion paint shall be approved by Garrison Engineer.
Excavation in trenches in soft and loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc., if required, complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes 150 mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested, if any, complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and Labour for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested complete for pipe of 150mm bore complete all as specified and directed.
Material and Labour for 150 mm salt glazed stone ware drain pipes laid in trenches and jointed complete all as specified and directed.
Material and Labour for Cutting into existing manholes for connecting new drains of internal dia of pipe 150mm making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and as directed
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out soft / loose soil, complete all as specified and as directed.
Material and Labour for Hardcore of broken stone boulder of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Material and Labour for 75 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone agg) as in sub base complete all as specified and directed.
Material and Labour for 60mm thick rubber moulded glossy finished inter locking paver block with grey cement and pigment of any type and shape the minimum compressive strength not less then 350 kg/sqcm as approved complete all as specified and directed.
Material and Labour for Sand filling under floor including watering and consolidation complete all as specified and directed.
Removing excavated material exc.250m but n exc 500m, deposited where directed complete all as specified and directed.
Material and Labour for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Material and Labour for brickwork using old size sub class -B brick straight or curved on plan exceeding 6m mean radius using old size brick built in CM (1:4) complete all as specified and directed
Material and Labour for PCC 1:2:4, type B1 using 20mm graded crushed stone aggregate as in surface channel and drain complete all as specified and directed.
Material and Labour for rendering 15mm thick in cement mortar (1:3) on brickwork finished even and smooth without using extra cement all as specified and directed.
Material and Labour for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, including forms, moulds, etc (inner girth only to be measured) complete all as specified and directed.
Add or deduct to Srl item No. 2.41 here-in-before for each 25mm girth or part thereof over or under 30cm inner girth of drain or channel complete all as specified and directed
M&L for mild steel framed work such as grills, grating etc with ends of bars shouldered and or riveted into spikes, framed guard bars, , barred iron doors, ladders, framed balusters, walk ways, railing, cooler platform, frame work of water tanks and similar work including welding conforming to Fe-290-0 & grade E-165 etc complete all specified and directed.
S&F magnetic ball catches of brass body and striking plate with 8 mm dia steel ball for cupboard shutter complete all as specified & directed.
S&F powder coated aluminium butt hinge 100mm long etc. complete all as specified & directed.
M&L for complete removal of existing treatment by scrapping using mechanical wall sander (Having mechanical vacuum mechanism) having RPM not less than 1500 and sanding pad of 80 grit having dia 7”/9” to make the surface free form dust/ loose paint etc complete all as specified and directed.
M& L for applying waterproof cement based putty @ 1 kg (undiluted) per Sqm at the average thickness 2mm over the plastered/old painted prepared surfaces of wall (after scrapping to prepare the surfaces even and smooth) and sanding the putty surfaces with mechanical wall sander (having mechanical vacuum mechanism and RPM not less than 1500), sanding pad of 240 grit or above to make the surface free from dust etc as per following steps :- Step 1- Mix the putty powder by adding water as per manufactures instructions and mix it with putty mixer with the mixing capacity of minimum 2.50 kg putty per minute, Step -2 Apply the first coat of prepared mix with the help of fully automatic airless spray machine of putty application having flow speed of maximum 6 liter per minute with a minimum pressure 3300 PSI. Step -3 Allow 6-8 hours to dry the putty surface.
M&L for one coat of acrylic water based interior grade primer @ 0.80 liter (undiluted)/10 Sqm diluted with water in 1:1 ratio and applying the same with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute at a pressure of 3300 PSI complete all as specified and directed.
Taking down carefully existing unserviceable copper/ aluminium point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. Note: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators light fittings etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
Material and labour for point wiring for one light /fan/Exhaust fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FRLSH,1100 volts grade in and including concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with laminated top sheet of 3 mm thick for housing of switchs, sockets, regulators etc including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. Note :-(I) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & capping of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers
All as per item No. 2.50 here-in-before but for one light point controlled by two way switch.
All as per item No 2.50 here-in-before but Point wiring for 5 pin socket ,6 Amps on same board complete all as specified and directed.
All as per item No 2.50 here-in-before but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board complete all as specified and directed..
Material and labour for point wiring for one Power point controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FRLSH,1100 volts grade in and including concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with phenol bonded polycarbonate top sheet of for housing of switchs, sockets, regulators etc including all accessories and earth continuity conductor using 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. NOTE :-(I) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & capping of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers
M&L for switch flush type, single pole, one way 5 Amps 240 volts, ISI marked white ivory finish complete all as specified and directed.
M&L for switch flush type, single pole, two way 5 Amps 240 volts, ISI marked white ivory finish complete all as specified and directed.
M&L for socket outlet 2 in 1, 5 pin 6 Amps flush type, ISI marked white ivory finish complete all as specified and directed.
M&L for switch/socket combination outlet 2 in 1.5 pin, 5 Amp flush type, 240 volts, ISI marked white ivory finish complete all as specified and directed.
M&L for switch/socket combination 2 in 1, 3 pin 5 & 16 Amps flush type ISI marked universal complete all as specified and directed.
S&F ceiling rose, surface bakelite 18 mm X 50 mm AC, 230 V polycarbonate isolated body, two or three terminals complete all as specified and directed.
S&F lamp holder PVC/Polycarbonate type with cord grip cap/back plate suitable for batten/angle /pendent fitting complete all as specified and directed.
S&F exhaust fan, steel body AC single phase 230 V of size 450mm sweep heavy duty with blade, frame and louvers complete all as specified and directed.
Supply and fixing step type electronic fan regulator single phase, 230 volt, 100/120 watt complete all as specified and directed.
S&F in repair decorative slim linear LED tube light fitting batten Type 01x20 watt light with co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with all accessories and connecting the same to ceiling rose with using copper conductor 24/0.20 flexible PVC sheathed and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified & directed by Engineer in-charge.
Supply and fixing in repair Street/Security light fittings 1X35W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia of 40mm (Max) with complete (40 mm GI pipe light grade ), clamp, nut-bolt and washers with impact and corrosion resistant including thermal management in multiple optics complete all as specified & directed by Engineer in-charge.
Supply and fixing of sheet metal enclosure Double door for DBs 8 way, 240 volts with 200 Amps rated bus bar IP-43 complete fixed properly in concealed position including internal incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed.
Supply and fixing of sheet metal enclosure Double door for DBs 12 way, 240 volts with 200 Amps rated bus bar IP-43 complete fixed properly in concealed position including internal incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed.
Supply and fixing of sheet metal enclosure Double door, TPN MCB DB, 4 way, 415 volts with 200 Amps rated bus bar, IP-43 TPN supply complete fixed properly in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed.
Supply and fixing of sheet metal enclosure Double door, VTPN MCB DB, 4 way, 415 volts with 200 Amps rated bus bar, IP-43 TPN supply complete fixed properly in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed.
Supply and fixing of sheet metal enclosure Double door, VTPN MCB DB, 6 way, 415 volts with 200 Amps rated bus bar, IP-43 TPN supply complete fixed properly in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed.
S&F MCB SP 6 to 32 Amps ('B' Series) having current rating 10 kA, 240 V complete all as specified and as directed.
S&F MCB SPN 40 to 63 Amps ('B' Series) having current rating 10 kA, 240 V complete all as specified and as directed.
S&F MCB TP 6 to 32 Amps ('B' Series) having current rating 10 kA, 415 V complete all as specified and as directed.
S&F MCB Four pole 6 to 32 Amps, 'B' Series having current rating 10 kA, 415 V complete all as specified and directed.
S&F MCB Four pole 40 to 63 Amps, 'B' Series having current rating 10 kA, 415 V complete all as specified and directed.
M&L for surface/concealed submain wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 2.5 Sqmm 1100 Volts and one run of copper stranded conductor of size 2.5 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :- (i) Two single core cable and one run of earth copper conductor including conduit will be measured and paid as one unit length. (ii)The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for conceling the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface.
M&L for surface/concealed submain wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 4 Sqmm 1100 Volts and one run of copper stranded conductor of size 4 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :- (i) Two single core cable and one run of earth copper conductor including conduit will be measured and paid as one unit length. (ii)The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for conceling the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface.
M&L for surface/concealed sub main wiring as required with Four single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 4 Sqmm 1100 Volts and one run of copper stranded conductor of size 4 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 25 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :- (i) Four single core cable and one run of earth copper conductor including conduit will be measured and paid as one unit length. (ii).The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for conceling the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface.
M&L for surface/concealed submain wiring as required with four single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 6 Sqmm 1100 Volts and one run of copper stranded conductor of size 6 Sqmm for continuous earthing drawn in and including rigid non metallic PVC conduit pipe ISI marked of size not less than 25 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :- (i) Four single core cable and one run of earth copper conductor including conduit will be measured and paid as one unit length. (ii).The quoted rate shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for conceling the conduits to required depth and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface.
Dismantling & Taking out MCB DBs VTPN any size, any type and capacity complete all as specified and directed.
Dismantling & Taking out MCBs/Isolator & metal clad box any size, any type and capacity complete all as specified and directed.
Disconnecting & taking up or down u/s submain wiring of aluminium/copper conductor with two run/four run of single core earth cable of any description, any size & in any position including taking out existing conduits of any description and making good the disturbed surface to existing surfaces complete all as specified and directed. Note:- Two run/ four run of single core PVC cable with one run of earth conductor shall be measured as one unit)
Taking down carefully ceiling fan/ Exhaust fan from existing place and removing to MES store yard Scraping, cleaning & painting with two coats of super enamelled paints (as approved by GE) greasing/oiling and refixing at site complete including electric connection with three core flexible wire 1.5 sqmm complete all as specified and directed.
Taking down carefully from existing place for re-use of geyser by disconnecting electric /water supply connection and refixing the same after civil work including all electric /water supply connection connecting with suitable wire all as specified and directed by Engineer-in-Charge.
M&L for Earthing using GI Electrode rod having outer dia 40mm and inner pipe dia 20mm, 2 to 3mm thick, 3 Mtr length and terminal strip 40x6mm for ground earthing subject to hot dip galvanization : 70-100 micron on the outer electrode 200-250 microns inside the electrodes .The empty space inside the electrode fully filled with a specially developed Crystalline ,Hygroscopic ,Conductive Mixture sealed. Augur /Drill/Bore a hole of 3 to 5 or 6 to 10 inches in diameter to a suitable depth of 3 meter. Mix backfill compound with dugout soil & put the mixture in to pit. Place the electrode at centre of the pit. Start refilling empty space around electrode with backfill compound in small quantities. Pour some water and push up the pit along with wooden rod. Allow trapped air to escape, in this manner gradually continue refilling process till electrode is fixed in the pit up to the patch painted on the top portion of electrode. Pour a few buckets of water around the pit per day for 3 days so the system can be set. Supply and fixed GI earth lead wire 4mm dia and 15mm dia GI protection pipe medium grade from earth terminal to test point up to 7.5 mtr length and connected to earth test point including testing complete all specified & directed by Engineer –in-charge. Note:- The use of backfill Earthing compound/ anti corrosion /Moisture retaining mixture @ 50Kg per earthing for reducing ground resistance is deemed to be included in quoted rate.
Supply, laying , jointing & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with stranded aluminium conductor , 1100 Volts grade of cross sectional area 35 Sq mm 3.5 core including taking out of cable any type and capacity from trenches, pole, road etc. including necessary joints & bricks & removing form site complete all as specified and directed. Note : Excavation, earth work, sand cushioning for cable and cable protection cover shall be measured & paid under respective item.
Supply, laying , jointing & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 25 Sq mm 4core including taking out of cable any type and capacity from trenches, pole, road, etc. including necessary joints & bricks & removing form site complete all as specified and directed. Note : Excavation, earth work, sand cushioning for cable and cable protection cover shall be measured & paid under respective item.
S&F Tube medium grade galvanised Tube of dia 40 mm for road crossing of cable and on pole and DB cable as in cable protection complete all as specified and directed.
M&L for sand filling with clean, dry and sieved fine natural river sand in two portion, including gently punning around cables after the cables are laid, in trenches for cable protection complete all as specified and directed. NOTE: Only punned thickness shall be measured for payment).
Supply & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Supply and install, testing and commissioning of solar water heating system (Flat Plate collector) based on direct transfer of heat of capacity of 500 LPD ltr capacity including electric back-up complete all as specified and directed.
Supply and install, testing and commissioning of solar water heating system (Flat Plate collector) based on direct transfer of heat of capacity of 300 LPD ltr capacity including electric back up complete all as specified and directed.
S&F GI Medium Grade Hot water Pipe duly insulated with and including glass wool and aluminium cladding 20mm bore complete including all fitting & fixtures all as specified and directed.
S&F GI Medium Grade Hot water Pipe duly insulated with and including glass wool and aluminium cladding 15mm bore complete including all fitting & fixtures complete all as specified and directed..
S&F GI Medium Grade Hot water Pipe duly insulated with and including glass wool and aluminium cladding 25mm bore complete including all fitting & fixtures complete all as specified and directed..
S&F Stop valves/Gate valves 20 mm dia cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed.
S&F in repairs bib cock, cast copper alloy , CP fancy type with long body shank, screwed down with high pressure screwed for iron pipe & fixed 15mm bore, complete all as specified and directed.
Supply and fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top ) hoisted and fixed in position incl taking down of water storage tanks any type and capacity of 1000 Ltrs & PCC (1:2:4) /CM(1:3) for fixing of water storage tanks complete civil work all complete all as specified and directed.
Supply, Installation ,commissioning of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 40/80 Ltrs complete all as specified and directed.
S&F 25 mm bore GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors or trenches complete all as specified and directed.
M/s Himgiri construction
PRAGMATIC INFRASTRUCTURE LIMITED
jayanti associates
Deepesh Electricals
JEE JEE BUILDERS
M/s Kohli Builders
Vee kay construction
M/s Bijender Singh
POONAM ELECTRIC INDUSTRY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .