Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹15.7 L+₹1.2 L (8.21%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹16.8 L+₹2.3 L (15.9%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹16.9 L+₹2.4 L (16.4%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹17.9 L+₹3.4 L (23.5%)Rejected-Finance | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jun 2024, 6:00 pmClosed
GE (AF) ADM AREA
GE (AF) ADM AREA GWALIOR-474020
REPAIR/MAINTENANCE OF CEILLING FANS, EXHAUST FANS, GEYSERS AND CONNECTED WORKS IN CHETAK, CHAMBAL, BHIND COMPLEX, RESIDENCY AND OTHER ADJOINING AREA AT AF STATION GWALIOR
2024_MES_655443_1
8420/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE (AF) ADM AREA GWALIOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) ADM AREA
₹60,000
Yes
3 Sept 2024
22 May 2024
26 Jun 2024
22 May 2024
19 Jun 2024
5 Jun 2024
Amount
Taking down carefully condensor, down rod, canopy ,fan blade, nut, bolts and washers, rubber real, condensor cap, Exhaust fan clamp,Exhaust fan frame from existing surface for repair complete all as specified and directed. Note:- (a) Adequate Nos Electricians & helpers shall be present at office of AGE E/M (AF) AA Maharajpur, Engineer-ln-Charge at 9 AM every day for taking instructions regarding repair work to be carried out on the day on priority.T&P required inclusive safety equipment & transport required to carry out regular repair work in domestic area or any area of airforce station Gwalior. (b) Alternative electrician shall be deployed in place of regular electrician to attend work on sunday/holiday for attending defects / complaints, if electrician fails to report or found absent or fails to rectify the defects / complaints then recovery @ Rs. 500/- per day shall be made from contractor's any due payment (c) The repair work on any single day may be ordered by Engineer-In Charge to be carry out in number of places/building in one day i.e in one building quantity of any of BOQ items to be carried may be one or more number of BOQ items to be executed on any single day may also be one or more. (d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & cost of labour deployed above is deemed to be included in quoted rates by the tenderer for all items of BOQ of this tender.
Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn) for repairs / servicing / overhauling / painting / numbering etc dismantling and opening of the fans for checking serviceablity of parts, overhauling, Hanging / fixing the fans in position after repairs. Overhauling shall include necessary cleaning, oiling & greasing, removing & replacement of defective/ unserviceable parts,with new parts, reassembling the fans, making necessary adjustment , proper alignment of blades, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’/BOQ and fixing charges for new items are deemed to be included under this item. (ii) Rewindings of fan motor shall be measured and paid for separately under appropriate item of Sch ‘A’/BOQ. (iii) The rates for above items are deemed to include for transportation of fan to and fro workshop if required and as directed by the Engineer-in-charge for necessary repairs. (iv) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’/BOQ.
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal)as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:-
Rewinding of motor of ceiling fans 1200/1400 mm sweep.
Rewinding of motor of exhaust fans of 225/230 mm sweep.
Rewinding of motor of exhaust fans of 300/375 mm sweep.
Rewinding of motor of exhaust fans of 450 mm sweep.
Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep:-
Supply only ball bearing No 6200
Supply only ball bearing No 6201
Supply only ball bearing No 6202
Supply only ball bearing No 6203
Supply only gun metal bushes of any description and size to suit existing motor shaft including grinding & polishing of fan motor shaft to required shape/size.
Supply only capacitor of capacity 2.5 mfd (PVC body)
Supply only capacitor of capacity 3.15 mfd (PVC body)
Supply only capacitor of capacity 4 mfd (PVC body)
Supplying only complete hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods.
Supply only PVC canopy of any description and suitable for any type & any make of fan.
Supply only PVC fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 230 mm sweep. Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.
Supply only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 300 mm sweep. Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.
Supply only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 450 mm sweep. Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.
Supply only PVC insulated and sheathed, round flexible cable, three core of size 23/0.0076 with copper conductor in pieces for connecting fans.
Supply only MS nuts & bolts with one hole washer & lock pin of suitable size for hanging assembly complete.
Supply only rubber real of suitable size of hanging assembly complete.
Supply only condensor cap PVC body
Supply only 300mm long down rod 20mm dia, MS tube, light grade, duly finished with powder coating of white colour, including necessary holes and threading etc
Supply only 600mm long down rod 20mm dia, MS tube, light grade, duly finished with powder coating of white colour, including necessary holes and threading etc
Supply only 1200mm long down rod 20mm dia, MS tube, light grade, duly finished with powder coating of white colour, including necessary holes and threading etc
Supply only 1800mm long down rod 20mm dia, MS tube, light grade, duly finished with powder coating of white colour, including necessary holes and threading etc
Supply only mild steel fan blade of size 1200 to 1400 mm and of standard thickness (Factory Made) duly balanced and painted of required colour at site
Supply only Exhaust fan clamp (leg) for 225/300mm exhaust fan as per sample (set of 3/4) including rubber packing and clamp bolt complete all as specified and directed
Supply only Exhaust fan clamp (leg) for 450 mm exhaust fan as per sample (set of 3/4) including rubber packing and clamp bolt complete all as specified and directed
Supply only Exhaust fan frame for 225/300mm exhaust fan as per sample complete all as specified and directed
Supply only Exhaust fan frame for 450 mm exhaust fan as per sample complete all as specified and directed
Supply only Exhaust fan motor for AC 220V, 50 Hz for 225/250mm exhaust fan as per sample complete all as specified and directed
Supply only Exhaust fan motor for AC 220V, 50 Hz for 300 mm exhaust fan as per sample complete all as specified and directed
M&L for taking down carefully serviceable ceiling fan/exhaust fan/cabin fan (any make any size) from any building and opening the same cleaning each part, oiling and greasing including replacement of worn out parts i.e nut, bolt, screw, split pin, rubber real and re-fixing in the same position after repair complete all as specified and directed.
Disconnecting & removing unserviceable capacitor from existing ceiling fan, exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep fixed in position at any locations (i.e. Md Accn/ OTM Accn / hangers) for replacement with new capacitor of following capacity complete all as specified and directed.:-
Capacitor of capacity 2.5 mfd (PVC body)
Capacitor of capacity 4 mfd (PVC body)
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gauge thick suitable for exhaust fan of 230/300mm sweep all as specified & directed by Engineer-in-Charge. Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two of synthetic enamel paint over a coat of red oxide primer
All as per item No.7.00 as here-in-before but suitable for exhaust fan of 450 mm sweep
Disconnecting & taking out old existing unserviceable fan regulator of any description & in any position / location complete all as specified and directed.
Supplying and fixing of fan regulator (Electronic step type) all as specified & directed by Engineer-in-Charge
Supplying and fixing fan hook made of of flat iron of suitable size and length, fixed with and including nut, bolts of suitable size including drilling holes for grouting nut, bolt etc complete all as specified & directed.
S&F MS clamps for fixing of fan hook as per sample made out of 5 mm thick MS flat including necessary cutting, drilling, welding and provision of necessary nut and bolts etc complete all as specified and directed.
M&L for repair to ceiling fan/ exhaust fan /wall mounted fan shaft by means of remetalling, grinding & polishing to make with the original size and shape and suitable for fixing of bearing of bush and repairing of bearing housing as required complete all as specified and directed.
M & L for painting of existing fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans including engraving MES No. of fan in capital letters of height not less than 20 mm on fan body all as specified and directed.
S&F in replacement of Armature with shaft for ceiling fas 1200/1400 mm sweep as per sample complete all as specified and directed.
S&F in replacement of top & bottom cover of armature suitable for ceiling fas 1200/1400 mm sweep as per sample complete all as specified and directed.
Supply and fixing exhaust fan, steel body, AC, single phase 230 V of size 230mm sweep with blade, frame and louvers including dismantling and taking down existing unserviceable fan complete all as specifed and directed.
S&F in exhaust fan made of sturdy engineering plastic complete with louvers shutter, 230V, 50Hz, 1200 RPM copper winding of sweep 300mm including dismantling and taking out existing exhaust fan complete all as specified and directed.
S&F in exhaust fan made of sturdy engineering plastic complete with louvers shutter, 230V, 50Hz, 900 RPM copper winding of sweep 225/250mm including dismantling and taking out existing exhaust fan complete all as specified and directed.
S&F in repair MCB single pole 6 to 32 Amps, "B" series, 10KA, 240 Volts complete all as specified
S&F in repair MCB single pole and neutral 40 to 63 Amps, "C" series, 10KA, 240 Volts complete all as specified
S&F in repair MCB TPN/FP 40 to 100 Amps, "B" series, 10KA, 240 Volts complete all as specified
Disconnecting & taking down the existing geyser of any description and any capacity (25/35/50 Ltrs) any make and in any position from the existing location for necessary repairs & maintenance/replacement/painting etc complete all as specified and directed
Dismantling, opening of the geyser of 25 ltrs capacity and of any description, material and labour for cleaning and de-scaling the inner tank and other parts/accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution (ORISCALE BLASTER) mixed with water in suitable proportion till the complete deposits/scale is removed upto the entire satisfaction of the Engineer-in-Charge, brazing for stopping the leakage of copper inner tank/ gas welding for stopping the leakage of inner steel tanks , fixing the serviceable parts in position, replacing the unserviceable parts, setting insulation properly as required, reassembling the geyser after cleaning, repairing and painting. Re-fixing & installation of the geyser in existing position and its testing to the entire satisfaction of Engineer-in-Charge. Note:- (i) Quoted rate of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new parts shall be measured and paid under respective item of BOQ as supply only. (ii) Painting of Geysers shall be on requirement basis and shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ. (iii) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool. Additional quantity of glass wool for insulation, if any required, other than the quantity of glass wool retrieved from dismantling of geyser shall be measured and paid for separately as supply only.
All as per item No 24.00 here-in-before but for Geysers of 50 Ltrs capacity
Supply only the following new parts suitable for Geysers of capacity under BOQ item No 24.00 & 25.00 here-in-before:- Note:-(i) The new parts should be compatible with the existing geysers (ii) Fixing element of these items is deemed to be included under the rates quoted by the contractor for respective BOQ item No 24.00 & 25.00 here-in-before.
(a) Inner steel tank for 25 Ltrs capacity having wall thickness not less than 1mm
(b) Inner steel tank for 50 Ltrs capacity having wall thickness not less than 1mm
(c) MS outer cover of any size and shape, for geyser of cap 25 Ltr not less than 1 mm thick all as specified
(d) MS outer cover of any size and shape, for geyser of cap 50 Ltr not less than 1 mm thick all as specified
(e) `U’ assembly for 25/50 Ltrs capacity geyser with rubber gasket
(f) Geyser elements of 1500 watts, 230 volts capacity
(g) Geyser elements of 2000 watts,230 volts capacity
(h) Thermostat with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply
(j) Indication lamp of size/shape as approved for geyser
(k) Fusible plug /safety valve as per sample(s) kept in GE office.
(l) Glass wool for insulation Geysers all as approved.
Disconnecting & taking up or down existing unserviceable PVC connections of any description from geysers installed at site and supplying and fixing new PVC connections with nylon braided, 15 mm bore 450 mm long having brass nuts and washers on both ends suitable for hot / cold water complete all as specified & directed.
Disconnecting & taking up or down existing unserviceable PVC connections of any description from geysers installed at site and supplying and fixing new HD PVC connections, 15 mm bore 450 mm long high pressure nylone braided having brass nuts and washers on both ends suitable for hot / cold water complete all as specified & directed.
M & L for painting of existing Geysers of any description and in any position 25/50 ltrs capacity, with applying one coat of Ducco paint (White) by spray machine including preparation of existing decorated surfaces of geysers including writing MES No. of geysers in capital letters of height not less than 20 mm on geysers body in the pattern and style all as specified and directed.
S & F in repair MS bottom cover of any size and shape, for geyser of cap 25/ 50 Ltr made out of MS sheet not less than 1 mm thick and as per existing size and shape complete all as specified.
Disconnecting, dismantling & taking up or down existing unserviceable `U’ assembly of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new `U’ assembly to match with the existing system complete all as specified & directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt, 230 volts to match with the existing system complete all as specified & directed by Engineer-in-Charge.
Description all as per item No 32.00 here-in-before but geyser element of 2000 watt.
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new thermostat with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply complete all as specified & directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser indication lamp of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new indication lamp complete all as specified & directed.
Disconnecting & taking up or down existing unserviceable fusible plug/safety valve of any description from geysers installed at site and supplying and fixing new fusible plug / safety valve of shape and size to match with the existing system all as specified & directed.
Disconnecting & taking up or down existing unserviceable copper conductor flexible cable of any size & any description and supplying, fixing, connecting & testing new 3 core copper conductor flexible cable of 50/.025 mm size, PVC insulated and PVC sheathed suitable for 1100 volts grade complete all as specified & directed.
Disconnecting and taking out existing defective/ unserviceable complete industrial type socket with top in sheet metal box, of any description & in any position and Supplying and fixing new industrial type socket, 2 pole + earth 20 Amps, with and including plug top and MCB, 20 Amps, ‘C’ series, single pole in sheet metal enclosure all as specified and directed.
M&L for cutting out holes in existing cement concrete / brick walls built in cement mortar and removing unserviceable/loose/ broken geyser’s mounting bolts including supplying, fixing & grouting new mild steel bolts with end screwed 8 mm dia & 100 mm long along with one washers and one hexagonal nut at screwed end for mounting the geyser on wall using cement mortar 1:3 and making good the disturbed surfaces to match with the existing surface & finishes complete all as directed.
Disconnecting & taking up or down existing unserviceable submain wiring of any description, any size from existing conduit complete all as directed. NOTE:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
M & L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in existing conduit with & including one run of PVC (green colour) insulated , unsheathed, stranded copper conductor cable FR of size 4 Sqmm as earth continuity conductor all as specified and directed. NOTE:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
Disconnecting & taking up or down existing unserviceable submain wiring of any description, any size from concealed conduit includig taking out existing conduit complete all as specified and directed. NOTE:- Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4 Sqmm of voltage rating upto and including 1100 Volts in and including PVC rigid concealed conduit of dia not less than 20mm with and including one run of PVC (green colour) insulated, unsheathed, stranded copper conductor cable FR of size 4 Sqmm as earth continuity conductor all as specified and directed. NOTE:(i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface.
Disconnecting & taking up or down existing unserviceable submain wiring of any description, any size from PVC conduit includig taking out existing conduit complete all as directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring in surface conduit using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4 Sqmm of voltage rating upto and including 1100 Volts in and including PVC rigid conduit of dia not less than 20mm with and including one run of PVC (green colour) insulated, unsheathed, stranded copper conductor FR of size 4 Sqmm as earth continuity conductor all as specified and directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from 50 Ltrs capacity geyser installed at site and supply and fixing new geyser element of 2000 Watt square flanged type, 230 volts to match with the existing system complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from 50 Ltrs capacity geyser installed at site and supply and fixing new thermostat two in one with cut off facilities and 11” long in size, 230 volts to match with the existing system.. Complete all as specified and directed.
S&F in repair switch socket combination multi purpose, 5 Pin 6/16 amps, flush type With Indicator complete all as specified and directed.
M & L for Plug Top 16 Amps, 240 Volts three pin complete all as specified and directed.
Disconnecting old unserviceable GI Pipe of any description and supply and fixing/laying pipe GI medium grade 15mm bore including fittings fix on wall or laid under floor complete with all accessories ISI Marked complete all as specified and directed.
Disconnecting and taking up or down existing unserviceable MCB of any description and in any position complete all as directed.
Dismantling, Disconnecting & taking up or down unserviceable geyser capacity 25 Ltrs of any Make of any description and in any position, taking out old unserviceable MS inner tank and supply and fixing new MS Inner tank having thickness not less than 1mm thick capacity 25 Ltrs of any make complete all as specified and directed.
All as per item No 52.00 here-in-before but Inner tank capacity 50 Ltrs -
Dismantling, disconnecting & taking up or down unserviceable geyser capacity 25 Ltrs of any Make fixed in any position, taking out old u/s plastic front cover CVRER-25 (V) and supply and fixing new plastic front cover CVRER-25 (V) capacity 25 Ltrs having thickness not less than 1mm thick of any make complete all as specified and directed.
All as per item No 54.00 here-in-before but Plastic front cover CVR-50 capacity 50 Ltrs complete all as directed.
Dismantling, disconnecting & taking up or down unserviceable geyser capacity 25 Ltrs of any Make fixed in any position, taking out old u/s plastic outer AL2 WH-25 (V) and supply and fixing new plastic front CVRER-25 (V) capacity 25 Ltrs of any make complete all as specified and directed.
All as per item No 56.00 here-in-before but Plastic outer AL-50 (V) capacity 50 Ltrs
Supplying & fixing MCB single pole (`C’ series ) 6 to 32 Amps capacity suitable for 240 volts having current rating 10 KA complete all as specified and directed.
Disconnecting old unserviceable metal clad plug top & supply and fix metal clad plug top AP-20 2 pin+earth complete all as specified and directed.
Disconnecting old unserviceable metal clad plug socket and supply and fix metal clad plug socket top AP 20 2 pin+earth complete all as specified and directed.
Disconnecting old unserviceable Heating elements and supply and fix Heating element for instant geysrs of any type and description capacity 3 KW complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt 230 volts to match with the existing system complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt /2000 watt of 9 Hole 230 volts to match with the existing system complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt /2000 watt of 6 Hole 230 volts to match with the existing system complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new thermostat with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply complete all as specified & directed by Engineer-in-Charge.
Disconnecting, dismantling & taking up or down existing unserviceable geyser Auto Switch of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new Auto Switch with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply complete all as specified & directed.
m/s varsha traders
M/s Anupam Construction Co.
Achal Construction
BABA DEVELOPERS
M/s KKPARASHAR
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .