Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹29.1 L
EMD Value
₹58,260
Closing Date
2 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE AF OJHAR
GE AF OJHAR AIR FORCE STN OJHAR DIST NASHIK 422221
PROVISION FOR ELECTRIC MOTORS FOR ENTRY / EXIT GATES AT 11 BRD
2026_MES_798246_1
8478/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF OJHAR
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹58,260
Yes
11 Nov 2026
11 Nov 2026
4 Dec 2026
11 Nov 2026
2 Dec 2026
26 Nov 2026
11 Nov 2026 - 25 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth for laying of of UG Cable etc and getting out in hard / dense soil complete all as specified and directed. | 116.64 | Cubic Metre | - | - |
| 2 | Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each. | 2.17 | Cubic Metre | - | - |
| 3 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point. | 114.47 | Cubic Metre | - | - |
| 4 | Supply and fix VPPL and MCCB box with busbars 64A, 440v capacity, in security cabin, near Technical Gate making necessary electrical connectios complete all as directed. | 1 | Each Set | - | - |
| 5 | M&L for Boring of holes under roads, pavements and hard standings by trenchless technology, at a depth of 0.60 metre below the existing top surface, including all necessary excavation/pit formation, setting up and operation of boring equipment, alignment, boring and disposal of surplus material out side MD land as ordered including supply, laying and fixing of 80 mm dia HDPE pipe, suitable for a working pressure of 0.40 MPa, including all necessary jointing, fittings, accessories, testing and making good the surface, complete to the satisfaction of Engineer-in-Charge. | 6 | Running Metre | - | - |
| 6 | Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts,16 Sqmm , 4 Core , 1100 volts grade XLPE insulated , armoured, electric power cables (heavy duty) with aluminium conductor , including dismantling old one. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs ,Cremping ,Glanding wherever required. | 442 | Running Metre | - | - |
| 7 | Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc complete all as directed Make :- Dura- line/Gemini/Rex. of size 38 mm inner dia | 432 | Running Metre | - | - |
| 8 | M&L for earthing including taking out GI plate with pipes earthing lead fasteners etc and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to galvanised iron strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & CI cover 10 mm thick of size (300mmx300mm CI) having locking arrengment hinged to CI frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. | 2 | Each Set | - | - |
| 9 | Taking down existing Main Technical Gate of size 5.34 Mts wide x 2.2 Mts height & repair of the gate stage wise are as under :- (a) Dismantle the existing gate from its position.
(b) Recondition the gate wheels- dia. 75 mm by replacement of anti-friction pre-lubricated 6201zz bearings for dia.12mm, axles and circlips.
(c) Recondition the bottom rail dia.- 16 mm; excavation bi-sides 75mm, straight and align the rail by steel fabrication, for smooth operation. Also fix stopper size 100mmH x 75mmW at back end of rail, to stop the gate mechanically including embedding 02 Nos MS holdfast / anchors 10 mm dia , 150 mm long to end stopper in PCC 1:1½ : 3 A1 concrete after necessary excavation & earth work ..
(d) Replace the guide rollers 4 Nos of 40 mm dia , 60 mm long along with with fittings and suitable size of fastners of holdpost.
(e) Install additional holdpost and guide rollers dia.40mm x 60mm- 2no. at the rear position of gate.
(f) Clean the gate, holdposts and M.S. accessories by means of grinding and finishing.
& apply one coat of yellow metal PU primer and two coat of epoxy enamel paint ( asian make ) confirming minimum 80 micron layer.
(g) Install the gate at it's position by means of hydraullic crane.
(h) Check alignment, perpendicularity and parallelism of rail, gate and rollers; tolerance to be < 3 mm.
(i) Install galvanised steel rack min.12mm face width, on the gate.
(j) Install sliding gate operator of capacity 600 kg on FFL foundation near existing holdpost.
Install infrared photocell of capacity min. 10m and buzzer lamp at the top of roller holdpost for safety purpose.
(k) Install limit switches 2 no. to define front and rear end limits of the gate.
Install manual switch board in security cabin having- Emergency stop, forward & reverse push buttons. Supply Remote units – 2 No.
(l) All the components must be suitable for outdoor application. | 1 | Each Job | - | - |
| 9.1 | (m) Electric copper cable 2.5mmx 4core to be connected for input supply from security cabin to gate operator, through 25 mm flexible conduit pipe.
(n) Curing of the operator concrete foundation & surrounding concrete for a min. 7 days.
(o) Make all electrical connections. After 7 days of curing, take the trial and set technical parameters, 6-12m/min. speed and set end limits.
(p) Noise level must not be greater than 60 dB.
(q) Operation must be smooth and sound.
(r) Testing for Sensor to ensure it stops the moving gate when anyone passes through its beam.
(s) Limit switches must stop the gate, when it reaches to front and rear end limits.
(t) Provide caution sheet and train minimum 3 gateman astleat for a period of 10 days until they get converesant to operate the gate. (Note : Quoted rate is deemed to be inclusive of above stages wise operation including tranning of Gate man ). | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_895486.xls
BOQ • 2.70 MB
TENDER8478.pdf
Tender Documents • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .