Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor (5) For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Electrical arrangements for : Tambaram(NSG 1)-Provision of 9 No's of Passengers Lifts at new Steel type FOB of 8M gangway width ,connecting skywalk and all platforms on MSB end & circulating area on east & west side of TBM Railway station
ME-29-II-1077-2025~SR
ME-29-II-1077-2025
Open
Works - General
60 Days
Chennai, Tamil Nadu
₹0
₹45,000
14 Jan 2026
23 Dec 2025
31 Dec 2025
35 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 22,50,049 | ||
| — | — | — | Above/ 12150.00 Below/P | ||
| a)Excavation of Cable trench in all kinds of soils duly removing all obstructions in the way of cable trench, dumping at embankment site within railway land complete as per specification enclosed and in a manner as directed by the Section Engineer in charge at site. NOTE: The Section Engineer, in charge at site, will indicate the route of cable trench. b)Re-filling of trench with excavated earth, ramming, consolidation and bringing back the surface to original condition complete in a manner as directed by the Section Engineer in charge at site. | — | 50.00 | — | — | |
| — | — | — | Above/ 10600.00 Below/P | ||
| Demolishing plain cement concrete in platform or elsewhere, disposal of material within railway land complete in a manner as directed by the Section Engineer in charge at site. | — | 20.00 | — | — | |
| — | — | — | Above/ 125720.00 Below/P | ||
| Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm blue metal complete in a manner as directed by the Section Engineer in charge at site. NOTE: Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest. | — | 20.00 | — | — | |
| — | — | — | Above/ 26100.00 Below/P | ||
| Laying/leading of 4 core 35 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx35 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 900.00 | — | — | |
| — | — | — | Above/ 31500.00 Below/P | ||
| Laying/leading of 4 core 70 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx70 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 900.00 | — | — | |
| — | — | — | Above/ 21000.00 Below/P | ||
| Laying/leading of 4 core 95 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx95 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 51000.00 Below/P | ||
| Laying/leading of 4 core 120 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx120 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 1000.00 | — | — | |
| — | — | — | Above/ 7250.00 Below/P | ||
| Laying of 63 mm dia ISI Marked High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 63mm dia HDPE pipe alone will be supplied departmentally. | — | 250.00 | — | — | |
| — | — | — | Above/ 11250.00 Below/P | ||
| Laying of 110 mm dia ISI Marked High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 110mm dia HDPE pipe alone will be supplied departmentally. | — | 250.00 | — | — | |
| — | — | — | Above/ 285660.00 Below/P | ||
| Supply, Installation, Testing and Commissioning of the LT Earthing arrangements duly by excavating/ auguring of earth pit in all kinds of soil/concrete surface or elsewhere, construction of masonry earth pit enclosure, provision of cover etc, complete including supply / leading / laying / burying and concealing of GI strip 25 X 3 mm from earth electrode to proposed MDB / SDB or elsewhere and in a manner as directed by Senior Section Engineer in charge at site.Note: 1) Masonry earth pit enclosure and cover shall be as per drawing number EL/P/TYPE/1022. | — | 45.00 | — | — | |
| — | — | — | Above/ 11200.00 Below/P | ||
| Supply and Concealing of 20mm dia rigid PVC conduits [IVORY colour] along with all accessories like junction boxes,bends and other items required as per site conditions and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] | — | 400.00 | — | — | |
| — | — | — | Above/ 30900.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Medium point i.e. length between 3 to 6 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi-stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 11 above complete with provision of 6 A flush type switch conforming to IS: 3854/1997 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in charge at site. | — | 100.00 | — | — | |
| — | — | — | Above/ 68600.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Long point i.e. length between 6 to 9 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi- stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 11 above complete with provision of 6 A flush type switch conforming to IS: 3854/1997 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in charge at site. | — | 200.00 | — | — | |
| — | — | — | Above/ 675000.00 Below/P | ||
| Supply of perforated cable trays of 300mm width X 50mm height made of 2.00mm thick hot dip galvanized Sheet steel complete with all accessories including coupler plate, supports fabricated using 40x40x6 mm MS angles for the longitudinal members and 40 x 6mm MS flats for the cross members and erection, testing and commissioning of the same duly supported from walls/ ceiling/roof purloins/structural steel works or elsewhere using intermediate supports by 40x6 mm MS flats complete in a manner as directed by Section Engineer-in-charge at site. Note:-The cable tray supports shall be applied with two coats of red oxide primer and painted with two coats of bright aluminium paint. | — | 750.00 | — | — | |
| — | — | — | Above/ 32700.00 Below/P | ||
| Installation, Testing and commissioning of 4 feet 20W LED light fitting Batten type suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site.Note: 4 feet LED 20W light fitting Batten Type with lamp alone will be supplied Departmentally | — | 300.00 | — | — | |
| — | — | — | Above/ 219300.00 Below/P | ||
| Supply,Installation,Testing and commissioning of SMC box assembly similar to Sintex Catalogue reference No.GSJB-1414 along with strip connector block,Neutral link,fuse bases and carriers onto lamp posts or elsewhere suing suitable MS clamping arrangements including all cabling and termination works complete as per site conditions and in a manner as directed by Section Engineer incharge at site | — | 300.00 | — | — | |
| — | — | — | Above/ 630119.00 Below/P | ||
| Supply of vertical, double door, 8 way MCCB distribution board conforming to IS: 8623 (latest), made out of powder coat finished CRCA sheet steel, having short time withstand current 50 kA per second and complete with electrolyte copper bus bar / earth link / brass neutral bar / DIN rail / cable adopter Boxes etc. 1 No. of 250A, FP, 36kA, MCCB (confirming to IS: 13947 (part II)) or latest with suitable mechanical and electrical interlocking and adjustable thermal settings, fixed magnetic settings, Earth Fault, Shunt Release etc as incomer and (2 No's 100A+2 No's 63A+2 No's 32A), 25kA,FP MCCB's (confirming to IS: 13947 (part II) or latest) with adjustable thermal settings, fixed magnetic settings as feeder control and 1 No. of multifunction meter as per the specification enclosed and with RS 485 port and suitable rated burden CT required complete and erection, testing and commissioning of the same onto wall or elsewhere including all internal wiring connections and terminations using suitable Angle iron frame work and other accessories and works required as per site conditions complete in a manner as directed by Section Engineer in charge at site. | — | 7.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .