Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
14 Nov 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC-I BSR
SE EDC-I HYDEL COLONY BULANDSHAHR
Under the Full Deposit Scheme item, work like construction of lines etc. for issuing connections as per the applications sent by the Provincial Block Public Works Department, Jal Jeevan Mission/other government departments.
2024_PVVNL_971051_1
T-51/EDC-I/B/2024-25
Open Tender
Electrical Works
Item Rate
30 days
BULANDSHAHR
PLZ REFER TENDER DOCUMENT
2 documents required · 2 mandatory
₹1,180
SE EDC-I
₹10,000
20 Nov 2024
6 Nov 2024
14 Nov 2024
6 Nov 2024
14 Nov 2024
6 Nov 2024
Amount
fo|qr forj.k [k.M&’k’Ve] cqyUn”kgj ds dk;Z{ks= esa fo0fo0m0[k0&izFke] vkSjxkackn@f}rh;] VkaM+k] cqyUn”kgj ds vUrxZr iw.kZ tek ;kstuk en esa izkUrh; [k.M yksd fuekZ.k foHkkx] ty thou fe”ku@vU; ljdkjh foHkkxksa }kjk izsf’kr vkosnukuqlkj la;kstu fuxZr djus gsrq ykbZu fuekZ.k vkfn dk;ZA
Carriage of fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms.
PCC Pole 8.5 mtr Long.
S.T Pole 11/13 Mtr. Long
Carriage of All line Material from store center BSR to at site ACSR Weasel conductor, ABC 4 condictor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc.
Erection of Single pole support including complete IT fittings with channelas per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of 11/13Mtr. STP Double pole/Scation Pole support including complete IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of 8.5 Mtr. Pcc Double pole/Scation Pole support including complete IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Single support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8=30x3030 cms. including the cost of cement, sand, birck hallast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Double pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8=30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Cutting/drilling/fabrication of channel and angleWelding of MS Angle iron for making guarding angle size 65x65x6/50x50x6 mm including the work of fixing the bracket on PCC/ST pole for construction of the line.
Carriage and mounting of 10/25/63 KVA T/F fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, requried for proper completion of work, distance about to 60 Kms.
Instalation of10/25/63/100 KVA T/F.
fixing of 11 Kv Stay rod with Stay wire in proper way with Nozelling.
Grouting of 11 Kv Stay rods.
fixing of 33 Kv Stay rod with Stay wire in proper way with Nozelling.
Grouting of 33 Kv Stay rods.
Carriage of 11 kv CT/PT metering pole mounted unit various ratio
Carriage and installation 11 kv pilferresistant metering cubicle with out cable termination kit.
Mounting of 11 kv CT/PT metering pole mounted unit various ratio
Laying, sagging. Stringing and binding and jumpering of ACSR Weisal, rabbit, dog newly erected pole as per RESPO manual and as per direction of supervising engineer. It
Fixing of Earthing Complete
ACSR weasel/ rabbit conductor
Laying of ABC cable size 3x50 sq. mm
Laying of ABC cable size 3x95/3x120 sq. mm
Laying of LT cable size 1x16/1x40 sq. mm
Fixing of 11 Kv DP Fues Set
Fixing of Droper Channel/Top Chennal/T-off chennel.
Fixing of 11 Kv Pin Insulator with pin and nut
Fixing of 11 Kv Disc Insulator with fitting
Fixing of TF Base Angle/bracing
Fixing of Distribution Box Three/Singal Phase
Complete Guarding
Fixing of 11 Kv Cross Arm
Laying of 11 kv XLPE cable of various size via Cutt-open method.
Fixing of 33 Kv Cross Arm
Laying of 33 kv XLPE cable by cutt-open method.
Filling and Instalation of 11/33 Kv Cable Jointing kit Varies Size.
Painting of STP Pole with primer & paint
Dismenteling of line work
Receive back of old material from site to store bsr
The folloing material is required to be Providing & Fixing by contractor
Danger Board with clamps
Holding/DP clamp.
F-Bracket with clamps
Barbed Wire
MS nut & Bolt off size.
J Hook
PG Clamp
LT Insulator
Suspension Clamp
LT Clamp
Paint & Primer
M S Enterprises (BID ID -4717876)
M/S RAGHAV and BROTHERS (BID ID -4717912)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .