Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC Tender is being accepted |
Tender Value
₹5.8 L
Closing Date
15 Dec 2021, 3:00 pmClosed
Executive Engineer (E), BSNL Bhubaneswar
Room no.317, 3rd Floor, Door Sanchar Bhawan, Unit-IX, Bbhubaneswar-751022
Repairing and Maintenance of MV Electrical Installations
2021_BSNL_97174_1
NIT No-79/BSNL/BSR/2021-22
Open Tender
Electrical Works
Item Rate
180 days
BSNL Bhubaneswar BA
3 documents required · 3 mandatory
₹0
Exempted
9 Mar 2022
6 Dec 2021
16 Dec 2021
6 Dec 2021
15 Dec 2021
6 Dec 2021
6 Dec 2021 - 11 Dec 2021
Amount
Checking, testing and attending minor faults of the fans, fittings, switches, MCBDBs, meter boxes and Service connection cable etc. of the newly allotted staff Quarters and switching on the power supply to the staff quarters etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group-A
Group-B
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
6 x 1.5 sq. mm
2 x 4 sq. mm
3 x 4 sq. mm
2 x 6 sq. mm
3 x 6 sq. mm
1 x 10 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100 mmX75 mm)
4 Module (125 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6 /10 Amps 1-way modular type switch
16/20 Amps 1-way modular type switch
6 /10 Amps 1-way piano type switch
20 Amps 1-way piano type switch
6 /10 Amps 3pin modular type socket
16/5 Amps 6 pin modular type socket
6 Amps 3 pin piano type socket
16 Amps 3 pin piano type socket
Bell push Modular type
Supplying and fixing one module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Dismantling of ceiling fan and painting the same with one coat of primer and two coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins refixing the same as required.
Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required.
Overhauling of Ceiling Fan i/c dismantling, heat varnishing of windings, greasing of bearings, refitting, testing etc. as required.
Replacement of the faulty/damaged components/spare parts for the electrical wirings, fittings, fans etc. by new ones of the following types and ratings i/c connection, testing etc. as required.
Calling Bell Musical type suitable for operation on 230 volts AC supply
Ceiling rose
Batten/Angle holder
Fan Capacitor 2.25mfd,440V
36/40-watt 240V Electronic Ballast (Phillips/Havells/Crompton)
9-watt 240V LED lamp BC type
Ceiling Fan Bearing
18-watt 6500K LED Ceiling Circular (Surface type), round white, polycarbonate housing. (Make: Bajaj/Havells / Phillips/Crompton/WIPRO/Surya)
20-watt surface / wall mounted LED Batten, 1.15CM having anti corrosion and rust proof polycarbonate housing and integrated electronic driver (Make: 20WRV5 of Havells or Equivalent of Phillips/Crompton/ Bajaj)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: Legrand/L&T/Siemens/SS)
8-way, Double door
12-way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/L&T/Siemens/SS)
Single pole
Double pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/L&T/Siemens/SS)
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/L&T/Siemens/SS)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply and fixing of Polycarbonate Bulk head fitting with 6.5-watt 6000K LED (Havells/Phillips/Crompton/Bajaj)
Supply and fixing of 32 Amps 240 volts SPN main switch on existing angle frame/surface of wall/board i/c connection etc. as required.
Providing 1200 Ceiling Fans for the Officers’ Quarters i/c installation, connection and testing etc. as required. (Havells-Velocity HS Or Equivalent of Usha/Bajaj/Crompton)
Providing 200 polycarbonate Exhaust Fans for the Officers’ Quarters i/c installation, connection and testing etc. as required. (Havells/Usha/Bajaj/Crompton)
Supplying and fixing of factory tested, direct connected type 1 phase 2 wire Digital energy meter of rating 10-60 amp, accuracy class-1.0, suitable for operation on 230/240V (P-N), 50 Hz+5% AC supply, operating temperature range from +55 deg C to -10 Deg C, protection class of IP-51 compliance to IS-13779, IEC-62052-11 and IEC-62053-21 with engineering plastic enclosure and provision for sealing of mains and terminal covers, etc.as reqd. (Make & Model: SECURE- I-Credit-350/equivalent model of L&T)
Replacement of faulty Service connection cables by new one of 2 core X4sqmm PVC insulated and PVC sheathed Aluminum conductor weather proof cable etc. as required.
Dismantling the old and damaged wirings and cleaning the rooms i/c removal of surplus materials etc. complete as required.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .