Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC HOUSE NO 54 PUBERUN PATH HATIGAON GUWAHATI 781038 KAMRUP M ASSAM | KAMRUP METRO | ASSAM | 781038 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹40.9 L+₹1.3 L (3.15%)Rejected-Finance C O BALAJI GLASS HOUSE OPP SBI MATHGHARIA NARENGI TINIALI GUWAHATI KAMRUP M ASSAM 781026 | KAMRUP METRO | ASSAM | 781026 | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹42.0 L+₹2.3 L (5.86%)Rejected-Finance 5C H M APARTMENT SATI JAYMATI ROAD ATHGAON KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-Finance Other than L1 bidder | |
| 4 | L4₹48.5 L+₹8.8 L (22.2%)Rejected-Finance JYOTINAGAR WEST NEAR HOLLY CHILD SCHOOL GUWAHATI 7810212 ASSAM | KAMRUP METRO | ASSAM | 781021 | L4 | Rejected-Finance Other than L1 bidder |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
9 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
PROVN OF WASHING POINT FOR SPL VEHS NEAR BLDG NO. P-7 UNDER GE NARANGI
2023_MES_632246_1
8670/NAR/E8
Open Tender
Civil Works
Item Rate
270 days
Narangi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Narangi
₹86,000
Yes
6 Nov 2024
12 Dec 2023
11 Jan 2024
12 Dec 2023
9 Jan 2024
26 Dec 2023
Amount
Surface excavation not exceeding 30 cm deep and getting out in soft/lose soil complete all as specified and directed.
Excavation over areas, not exceeding 1.5 m deep and getting out in soft loose soil complete all as specified and directed.
Excavating over areas exceeding 1.50m but not exceeding 3.00m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable or foundation of pole etc. not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated materials not exceeding 50mm and depositing where directed at a level not exceeding 1.5 above the starting point complete as specified and directed
Supply only approved Earth in soft/loose soil from outside MOD land not exceeding 1.5 mtr deep, distance exceeding 10 Km but not exceeding 15 Km and getting out and removing to site of work and depositing/spreading and compaction complete all as specified and directed. Note: The soil will be approved by GE before bringing to the requisite site.
M&L for PCC 1:4:8, Type D-2 (using 40mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for RCC M25 (design mix) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M25 (design mix) as in walls, retaining walls, basement walls, ballast walls and the like any thickness above top of footings including attached pilasters and buttresses complete all as specified and directed.
M&L for RCC M25 (design mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Formwork (fair finished surface and flat) to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
M&L for Formwork (rough finished surface and flat) to faces of walls, retaining walls, abutments, parapets and staircase, railings and similar work including attached pillasters, buttresses etc. vertical or to batter complete all as specified and directed.
M&L for 50mm thick PCC 1:2:4 type B-1, (using 20mm graded stone aggregates), finished even and rough without using extra cement as in hardstanding complete all as specified and directed.
M&L for Hardcore (broken stones or boulders) of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregates) finished even and rough without using extra cement as in hardstanding/sub base complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type B2 (using 40mm graded stone aggregates) finished even and rough without using extra cement as in hardstanding complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in parapets and railings upto 60cm in height, copings, kneelers, apex stones and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar 1:4 on bricks or concrete surfaces, finished fair and even without using extra cement complete as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on bricks or concrete surfaces, finished fair and even without using extra cement complete as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending, spirally for stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F of PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed.
Supply & laying of Polythene film black 50 micron laid below RCC floor for RCC slab complete as specified and directed.
Cutting of existing steel tubing 50/40mm dia for alterations or additions (each cut measured) complete all as specified and directed
Supply & laying in trenches Gl tubing 25mm bore medium grade ISI marked including complete fittings all as specified and directed
Supply & laying in trenches Gl tubing 20mm bore medium grade ISI marked including complete fittings all as specified and directed
S&F of Gun metal, globe or gate valves 25mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete as specified and directed
S&F of ball brass valves 20mm, high pressure with polythylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete as specified and directed
Supply, fixing, testing and commissioning of special vehicle washing system 3 phase, 50Hz, operating voltage 415 v with flow rate of 400-700 Itrs/hr having 4.3 kW capacity (6HP) with triple plunger washer for high pressure washing, direct driven and positive suction including necessary PCC foundation, suitable size nuts & bolts washer and foot valve strainer including 30m hose pipe OEM recommended size, high pressure nozzle of size 20mm and electrical connection including DOL starter, panels etc complete all as specified and directed. Note: Special Vehicle Washing system shall be of Model No. 1.353-913.0 of Make Karcher or equivalent as approved by GE.
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead strip of 25x4mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40 mm dia GI pipe connected to main control board and GI pipe medium grade 20 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover shall be 1:1.5:3 flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded stone aggregates) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre and testing after completion all as specified and shown on plate No 3 of SSR Part-1 2009.
Supply, laying, connecting, testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Material and labour for sand cushioning to underground cable for protection with fine river sand over, UG cable laid in trenches and gently punned to cushioning to cable complete all as specified and directed. (Note: Thickness of sand cushion shall be 150 mm thick below cable, 80 mm above the cable and punned down to a thickness of 180 mm which shall be measured and paid.)
M&L for Sub class 'B' old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and directed.
M&L for GI pipe light grade 40mm bore dia with all fittings to be laid in trenches or in floors complete all as specified and directed.
S&F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated bus bar 4 way Double door (Vertical DB with MCB as incomer) Conforming to IS including fixing the DB box flush in wall of any type and making good the disturbed surface to match with the existing complete all as specified and directed.
S&F of MCB FP 16 to 32 Amps, 10 KA 'C' Curve, including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F of MCB TP 16 to 32 Amps, 10 KA ‘C' curves connection complete with connection complete all as specified and directed.
M/S Abhishek Enterprise
M/s JK Jangid and Company
Rana Kr Phookan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .