Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC HOUSE NO 11 BYE LANE 1 EAST PUB SARANI SANKAR DEB PATH CHANDMARI DIST KAMRUP METRO ASSAM 781003 | GUWAHATI | KAMRUP METRO | ASSAM | 781003 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹51.7 L+₹2.4 L (4.93%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹52.3 L+₹2.9 L (5.96%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹54.6 L+₹5.3 L (10.7%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 |
| Sl No | Description | Qty | Unit | AFTAB ENTERPRISES L4 | boruah construction L3 | M L TREATMENTS L1 | VISHWAKARMA ELECTRICAL L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. | 583 | Cum | 430 ₹2,50,690 | 408 ₹2,37,864 | 370 ₹2,15,710 Lowest | 389 ₹2,26,787 |
| 2.00 | Excavating in trenches n exc 1.5m wide and exc 1.5m but n exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. | 1 | Cum | 454 ₹454 | 430 ₹430 | 380 ₹380 Lowest | 399 ₹399 |
| 3.00 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. | 280 | Cum | 48 ₹13,440 | 48 ₹13,440 | 30 ₹8,400 Lowest | 32 ₹8,960 |
| 4.00 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. | 304 | Cum | 66 ₹20,064 | 64 ₹19,456 | 40 ₹12,160 Lowest | 42 ₹12,768 |
| 5.00 | M&L for clear sand cushioning with dry clean sand for protection of cable, 15cm below the cable and 8cm above the cable, complete all as specified and as directed.
Note : Punned thickness shall be measured for payments. | 233 | Cum | 1,241 ₹2,89,153 | 1,174 ₹2,73,542 | 1,090 ₹2,53,970 Lowest | 1,145 ₹2,66,785 |
| 6.00 | Supply and laying unreinforced precast concrete cable cover class LV, type 1, flat size 250 x 150 x 40 mm for cable protection, complete all as specified and as directed. | 24,050 | Each | 23 ₹5,53,150 Lowest | 24 ₹5,77,200 | 25 ₹6,01,250 | 26 ₹6,25,300 |
| 7.00 | Boring of holes horizontal for laying not less than 80/50/40/32mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed.
Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate. | 20 | RM | 1,366 ₹27,320 | 1,292 ₹25,840 | 1,200 ₹24,000 Lowest | 1,260 ₹25,200 |
| 8.00 | S&F RCC cable route indicator with embrossing mark as LT cable, of size 75 cm x 15cm x 7.5cm complete all as specified and directed. | 25 | Each | 772 ₹19,300 | 731 ₹18,275 | 550 ₹13,750 Lowest | 578 ₹14,450 |
| 9.00 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 150 sq.mm 3.5 Core, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.
Note : (1) Pipes shall be measured and paid separately under relevant items.
(2) Excavation and earth work shall be measured and paid separately. complate all as specified and directed. | 125 | RM | 1,491 ₹1,86,375 | 1,410 ₹1,76,250 | 1,230 ₹1,53,750 Lowest | 1,292 ₹1,61,500 |
| 10.00 | All as per Sch 'A' item No 9 here in above but of size 95 sq mm 3.5 Core. | 800 | RM | 989 ₹7,91,200 | 936 ₹7,48,800 | 790 ₹6,32,000 Lowest | 830 ₹6,64,000 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
1 Sept 2025, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM PIN-786183
SPL REPAIR/REPLACEMENT OF LT PANELS BOARD AND COVERSION OF LT OVERHEAD LINE TO UG CABLE AND CONNECTED WORK FOR 1861 UNIT, PROVN OF GEYSER AGAINST DEFI IN BLDG NO T-23, T-24A AND PROVN OF UPS FOR OT AND ICU AT 162 MH UNDER GE DINJAN
2025_MES_709672_3
C/8848/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹97,000
Yes
10 Sept 2025
13 Aug 2025
6 Sept 2025
13 Aug 2025
1 Sept 2025
20 Aug 2025
Amount
Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and exc 1.5m but n exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
M&L for clear sand cushioning with dry clean sand for protection of cable, 15cm below the cable and 8cm above the cable, complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
Supply and laying unreinforced precast concrete cable cover class LV, type 1, flat size 250 x 150 x 40 mm for cable protection, complete all as specified and as directed.
Boring of holes horizontal for laying not less than 80/50/40/32mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed. Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate.
S&F RCC cable route indicator with embrossing mark as LT cable, of size 75 cm x 15cm x 7.5cm complete all as specified and directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 150 sq.mm 3.5 Core, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately. complate all as specified and directed.
All as per Sch 'A' item No 9 here in above but of size 95 sq mm 3.5 Core.
All as per Sch 'A' item No 9 here in above but of size 70 sq mm 3.5 Core.
All as per Sch 'A' item No 9 here in above but of size 35 sq mm 3.5 Core.
All as per Sch 'A' item No 9 here in above but of size 25 sq mm 3.5 Core.
All as per Sch 'A' item No 9 here in above but of size 25 sq mm 2 Core.
All as per Sch 'A' item No 9 here in above but of size 16 sq mm 4 Core.
All as per Sch 'A' item No 9 here in above but of size 16 sq mm 2 Core.
All as per Sch 'A' item No 9 here in above but of size 10 sq mm 4 Core.
All as per Sch 'A' item No 9 here in above but of size 10 sq mm 2 Core.
M&L for GI pipe light grade with all fittings complete grouted in ground all as specified for 32mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable including taking down old unserviceable complete all as specified and directed.
M&L for GI pipe light grade with all fittings complete grouted in ground all as specified for 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable including taking down old unserviceable complete all as specified and directed.
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size any type from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and as directed
Dismantling cross-arms of M.S. channel or angle sections etc. complete and stacking aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work complete all as specified and as directed.
M&L in repair, dismantling the all cable from panel, poles, MCB Main DBs taking out the cable loop stretching out the cable, carrying out end termination with new lugs, proper thimbling, fixing the joint kits connecting back to the new/existing panel board by means of nuts, bolt & washers of any size any type complete all as specified and as directed. Note : (i) The work includes necessary excavation to take out the loop and laying the cable, putting proper cable protection bricks using the old retrieved bricks and refill the area properly and spreading any surplus soil. (ii) The cost of AI lugs, joint kit shall be measured and paid separately under relevant items of schedule.
Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, hot shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 70 Sqmm to 150 Sqmm 3.5/4 Core complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately.
Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, heat shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 25 Sqmm to 50 Sqmm 2/3.5/4 Core complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately.
Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 6 Sqmm to 16 Sqmm 2/3.5/4 Core complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately.
S&F new PVC cable Junction Box IP66 "halogen free and weather proof" for out door installation size not less than 200 x 150 x 100 mm suitable for street light incoming and outgoing cables up to 10 to 25 sqmm 4 core (with terminal) & inclusive of MCB SP 10 Amp, 60A 04 strip aluminium Bus Bar, including nuts,bolts,cable glands & MS clamps fixed to pole all as directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire unarmoured, electric control cables (Heavy duty) with stranded Aluminium conductor of size 1.5 sq mm ,2 core, 1100 Volts grade passed throuh PVC conduit medium grade of size Min 20mm complete all as specified and directed.
M&L Earthing complete with Galvanised steel earth plate 60cmx60cmx6mm thick electrode, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 m below ground level , connected to GI earth strip 25 X 4mm up to test point by means of bolts ,nuts , check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm dia GI pipe medium grade, watering pipe and 20 mm bore GI pipe, light grade for protection of earth strip, MS angle iron frame 40x40x3mm, 10mm thick RCC 1:2:4 type B-1 cover reinforced with 6mm dia MS bars @ 75mm C/C both ways and with MS handle made out of 12mm dia bars, PGI Funnel, wire mesh etc complete all as shown in electrical Plate No 03 of SSR Part-I and connected to earthing test point all as specified or indicated including testing on completion complete and including taking down old u/s.
Supply, install, testing and commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m , factory made totally enclosed dust and vermin proof , double steel shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated, latest IP 65 and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable enty/exit point in both front and rear door painted with powder coated paint and Aluminium bus bar 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type (mix ratio 1:3:6) painted with white/red colour all around the panel board complete with the following items:- (FP-1& FP-3) Note : Foundation to be included in the quoted price Incoming :-(a) MCCB, 4 Pole,200A, 415 V, 25 kA. (I/C). Fixed Thermal Magnetic release. (b) 3 Phase LED Voltmeter Cl-1 (c) Phase indicator lamps (RYB) - set of 3 (d) Aluminium bus bar 4 strip - 400 amps (Length should not be less than 0.7m) (e) Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc Outgoing :- (a) MCCB, 4 Pole, 100 A, 415 V 25 kA - 01 nos (b) MCB,TPN, 32A, 240 V, 16 kA - 05 Nos. (c) MCB,TPN, 63A, 240 V, 16 kA - 02 Nos. (For street light and 01 extra)
Supply, install, testing and commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m , factory made totally enclosed dust and vermin proof , double steel shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated, latest IP 65 and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable enty/exit point in both front and rear door painted with powder coated paint and Aluminium bus bar 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type (mix ratio 1:3:6) painted with white/red colour all around the panel board complete with the following items:- (FP-2) . Note : Foundation to be included in the quoted price Incoming :-(a) MCCB, 4 Pole, 250 Amp, 415 V, 50 kA.(I/C). - 01 No.(fixed Thermal Magnetic release). (b) 3 Phase LED Voltmeter Cl - 1 Nos. (c) Phase indicator lamps (RYB) -set of 3 (d) Aluminium bus bar 4 strip - 400 amps (length should not be less than 0.7m) (e) Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc Outgoing :- (a) MCCB, 4 Pole, 100Amp, 415 V, 25 KA - 01 No (b) MCB, TPN, 32A, 240 V, 16 kA - 05 Nos. (b) MCB, TPN, 63A, 240 V, 16 kA - 02 Nos. (For street light , cook house and 01 extra)
Supply, install, testing and commissioning outdoor type LT panel of size 1m x 1m x 0.5m , factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated, latest IP 65 and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable enty/exit point in both ront and rear door painted with powder coated paint and Aluminium bus bar 200 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type (mix ratio 1:3:6) painted with white/red colour all around the panel board complete with the following items:- (FP -4). Note : Foundation to be included in the quoted price Incoming :- (a) MCCB, 4 Pole, 160A, 415 V, 36 kA. (I/C). (b) Phase indicator lamps (RYB) -set of 3 (c) Aluminium bus bar 4 strip -200 amps (length should not be less than 0.7m) (d) Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc Outgoing :- (a) MCCB, 4 Pole, 100 Amp, 415 V, 36 kA - 01 No (b) MCB, TPN, 63 A, 240 V, 16 kA - 05 No.
Supply, install, testing and commissioning outdoor type LT panel of size .6m x 0.6m x 0.5m , factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated, latest IP 65 and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable enty/exit point in both front and rear door painted with powder coated paint and Aluminium bus bar 200 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type (mix ratio 1:3:6) painted with white/red colour all around the panel board complete with the following items:- (Bus Bar Panel). (a) Aluminium bus bar 4 strip of 200 Amps having hole drilled on Bus Bar for fixing of cables. Note : Foundation to be included in the quoted price
M&L for plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations of stay assembly, poles, strut etc complete all as specified and as directed.
Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and as directed.
Dismantling of GI earth wire 4.0mm or any size complete all as specified and as directed.
M&L for sub main wiring with four run of 6 sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC conduit of suitable size, surface/concealed etc including provision of 2x4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) Extra length of cables/wire required for connectionto MCBs/DBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly. (b) For concealed wiring cutting chases, chipping and plastering shall be measured and paid separately under relevant items.
S&F 15 KVA UPS for 01 hours back up, three phase AC input with 300 to 450 Volts and out put three phase AC out put Voltage 230 V ± 1% of capacity with 12 Volts 65 Amps battery 20 Nos including battery rack of makes exide complete all as specified and as directed.
S&F 10 KVA UPS for 01 hours back up, three phase AC input with 12 Volts 65 Amps battery 14 Nos of makes exide including battery rack complete all as specified and as directed.
S&F sheet metal enclosure box with five faces without back sheet made out of CRCA sheet of 2mm thick double door fixed on wall with grouting nuts and bolts firmly complete of size 900mm x 600mm x 300mm for covering of MCB DBs and MCCBs installed on wall complete all as specified and as directed.
Supply, install, commissioning and testing of commercial Air curtain unit of DOOR OPENING SIZE 58" x 84" for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS CRCA 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening as specified.
S&F of water storage heater (Geyser) of 25 Ltrs capacity, BEE 5Star rated , Copper Heating Element , Magnesium Anode Rod, Vertical type with vitreous Enamel Glass line on steel inner tank , 240 Volts, AC, 50 Hz, High Grade thermostat and Thermal cut out, Temperature Adjustment Knob, indicating Lamp, power consumption max 2Kw , Rated Water Pressure : 8bar, hot and cold water connection Pipe of same brand, fixing arrangement on wall with fasteners, Make-USHA/Havells/Crompton/Recold.
VISHWAKARMA ELECTRICAL (BID ID -3405214)
boruah construction (BID ID -3412420)
AFTAB ENTERPRISES (BID ID -3412660)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .